Public Works Building And NH Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,23,784Document Cost
₹ 1,240Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWBNH_35758_1Bid Award Id
ViewTender No
LBCNL/2023-24/Dhemaji/D-02Tender Authority
Public Works Building And NH Department ViewPurchaser Address
-Website
http://https://pwdbnh.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Steel reinforcemnet for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
189.72
-
-
Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.2 :- cement mortar 1:4 (1 cement : 4 coarse sand)
492.44
-
-
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.2 :- 1:4 (1 cement: 4 fine sand)
984.88
-
-
62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 Graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 ( 1 cement hardener mix : 2 graded stone aggregate. 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
547.5
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
984.88
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1:- water thinnable cement primer
984.88
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade.
984.88
-
-
Providing and fixing Clorinated Polyvinyl horide (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints compplete as per direction of Engineer - in charge. External work 18.9.7 :- 65 mm nominal dia Pipes. Drain pipe from Roof slab to ground level
468
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S Sheets and galvanized with zinc coating of 120 gms/sqm ( both side inclusive) a per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre, one flange fixed to the ceiling etc 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095- (Part I) : 2011 ( Board with BIS certifications marks)
1471.85
-
-
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side / top/ centre hung, with beading and all members suck as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joits mitred and flash butt welded and sash bars tenoned and riveted, including, providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excvluding the of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1193.4
-
-
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point wiyth 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
20
-
-
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point wiyth 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
45
-
-
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point wiyth 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
30
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
241
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
390
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
280
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire
240
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 4 x 10 sq. mm + 1x 6 sq. mm earth wire
180
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 4 x 16 sq. mm + 2 x 6 sq. mm earth wire
25
-
-
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 amps switch
110
-
-
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 A switch
10
-
-
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 A socket outlet
24
-
-
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6 pin 15/ 16 A socket outlet
10
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existiong modular plate switch box including connections but excluding modular plate etc. as required
30
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as reqd.
36
-
-
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 4 Module (125mm x 75mm)
7
-
-
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 6 Module (200mm x 75mm)
10
-
-
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 8 Module (125 mm x 125mm)
9
-
-
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 12 Module (200mm x 150mm)
10
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connection etc. as required.
10
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
10
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the exisiting junction box/wooden block including connections etc. as required
110
-
-
Supplying and fixing brass batten/angle holder including connection etc as reqd.
60
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd.
25
-
-
Installation, testing and commissioning of Ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq mm.FRLS PVC insulated, copper conductor, single core cable etc. as reqd.
30
-
-
Provding and fixing following rating and breaking capacity and pole MCCB with thermo amgnetic release and terminal spreadersin existing cubicle panel board including rilling holes in cubicle panel, making connections etc as reqd. 150A, 16KA, TPMCCB
2
-
-
Provding and fixing following rating and breaking capacity and pole MCCB with thermo amgnetic release and terminal spreadersin existing cubicle panel board including rilling holes in cubicle panel, making connections etc as reqd. 100 A, 30KA, FPMCCB
2
-
-
Supplying and fixingfollwoing way, single pole and neutral, sheet steel, MCB distribution board, 240 V , on surface/recess, complete with tinned cooper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as reqd. (But without MCB/RCCB/Isolator) 8 way, Double Door
3
-
-
Supplying and fixingfollwoing way, single pole and neutral, sheet steel, MCB distribution board, 240 V , on surface/recess, complete with tinned cooper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as reqd. (But without MCB/RCCB/Isolator) 12 way, Double Door
3
-
-
Supllying and fixing 5A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commisiioning as reqd. single Pole
38
-
-
Supllying and fixing 5A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commisiioning as reqd. Double Pole
6
-
-
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as reqd. 63 A
6
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc as reqd. 40 A
6
-
-
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 v"c" curve DP MCB complete with connections, testing and commisioning etc. as reqd.
4
-
-
Earthing with copper earth plate 600 mm x 600 mmx 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal/coke and salt as reqd.
4
-
-
Providing and layiing earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I pipe from earth electrode including connection with copper thimble excavation and refitting as reqd.
60
-
-
Supplying, installation, testiung and commisioning of ceiling fan, 1200 mm sweeep Usha made, APOLLP LX/or equivalent make complete with all accessories as reqd.
15
-
-
Supplying with fitting and fixing of LED 18/20W T-5 luminaries complte with all accessories such as ballast, starter etc directly on wall/Ceiling with making necessary connection as reqd.
40
-
-
Supplying and fitting of 9/12 watt LED lamp in the existing batten holder/Angle holder/bracelet/pendent holder etc as directed.
60
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements