Public Health Engineering Department Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Public Health Engineering Department - PHED Tender
Eprocure
Opening Date17 Feb 2021
Closing Date3 Mar 2021
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Fixation Of Rates Of Items Of New Pwss For Dima Hasao Under Jjm Assam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PHED_21286_1Bid Award Id
ViewTender No
PHE_41_JJM_20_21_T_31481_87Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phe.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
c) Cost for drilling in Rocky Strata in DTH
1
-
-
... More
Construction of RCC Intake Weir for various PWSS
1
-
-
... More
Supplying, fitting, fixing, testing and commissioning of Raw Water Gravity Main (GI pipes) of different diameter a) 150 mm
1
-
-
... More
b) 100 mm
1
-
-
... More
c) 80 mm
1
-
-
... More
d) 65 mm
1
-
-
... More
e) 50 mm
1
-
-
... More
f) 40 mm
1
-
-
... More
Supplying, fitting, fixing, testing and commissioning of Raw Water Pumping Main (GI pipe) of different diameter a) 150 mm
1
-
-
... More
b) 100 mm
1
-
-
... More
c) 80 mm
1
-
-
... More
d) 65 mm
1
-
-
... More
e) 50 mm
1
-
-
... More
f) 40 mm
1
-
-
... More
Construction of RCC Slow sand filter of 4.00 sqm size for various PWSS
1
-
-
... More
Construction of RCC Slow sand filter of 6.25 sqm size for various PWSS
1
-
-
... More
For Rapid sand filter (4 sqm) with Internal Connection between T.P and U.G.R
1
-
-
... More
For Rapid sand filter (6 sqm) with Internal Connection between T.P and U.G.R
1
-
-
... More
Construction of Overground RCC Clear Water reservoir of different capacities a) 15000 L
1
-
-
... More
b) 20000 L
1
-
-
... More
c) 50000 L
1
-
-
... More
d) 60000 L
1
-
-
... More
e) 80000 L
1
-
-
... More
f) 100000 L
1
-
-
... More
Construction of Underground RCC reservoir of different capacities a) 70,000 Lit. (5.00m x 4.80m X 3.5m)
1
-
-
... More
b) 70,000 Lit. (6.00m x 4.00m X 3.5m)
1
-
-
... More
c) 60,000 Lit. (5.00m x 4.00m X 3.5m)
1
-
-
... More
d) 60,000 Lit. (5.30m x 3.75m X 3.5m)
1
-
-
... More
e) 50,000 Lit. (5.00m x 4.00m X 3.0m)
1
-
-
... More
f) 50,000 Lit. (4.50m x 4.50m X 3.0m)
1
-
-
... More
g) 40,000 Lit. (5.00m x 3.20m X 3.0m)
1
-
-
... More
h) 40,000 Lit. (4.00m x 4.00m X 3.0m)
1
-
-
... More
i) 30,000 Lit. (4.00m x 3.00m X 3.0m)
1
-
-
... More
j) 20,000 Lit. (3.20m x 3.20m X 2.45m)
1
-
-
... More
k) 15,000 Lit. (3.20m x 2.50m X 2.45m)
1
-
-
... More
Supply, fitting, fixing of Submersible Pump with Accessories a) 1 HP Single Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
b) 1 HP Single Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
c) 1 HP Single Phase (Head loss 55 m, Depth of column pipe=100 m)
1
-
-
... More
d) 2 HP Single Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
e) 2 HP Single Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
f) 2 HP Single Phase (Head loss 55 m, Depth of column pipe=100 m)
1
-
-
... More
g) 2 HP Single Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
h) 3 HP 3-Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
i) 3 HP 3-Phase (Head loss 55 m,Depth of column pipe=100 m)
1
-
-
... More
g) 3 HP 3-Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
h) 5 HP 3-Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
i) 5 HP 3-Phase (Head loss 55 m, Depth of column pipe=100 m)
1
-
-
... More
j) 3 HP 3-Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
k) 5 HP 3-Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
l) 5 HP 3-Phase (Head loss 55 m, Depth of column pipe=100 m)
1
-
-
... More
m) 5 HP 3-Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
n) 5 HP 3-Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
o) 7.5 HP 3-Phase (Head loss 55 m, Depth of column pipe=100 m)
1
-
-
... More
p) 5 HP 3-Phase (Head loss 32 m, Depth of column pipe=80 m)
1
-
-
... More
k) 5 HP 3-Phase (Head loss 32 m, Depth of column pipe=300 m)
1
-
-
... More
r) 7.5 HP 3-Phase (Head loss 43 m, Depth of column pipe=90 m)
1
-
-
... More
s) 7.5 HP 3-Phase (Head loss 55 m, Depth of column pipe=100 m)
1
-
-
... More
t) 7.5 HP 3-Phase (Head loss 55 m, Depth of column pipe=300 m)
1
-
-
... More
Supply, fitting, fixing of Electric driven Clear Water Centrifugal Pump Set a) 1 HP Single Phase (Head loss 30 m)
1
-
-
... More
b) 2 HP Single Phase (Head loss 30 m)
1
-
-
... More
c) 2 HP Single Phase (Head loss 30 m)
1
-
-
... More
d) 3 HP 3-Phase (Head loss 30 m)
1
-
-
... More
e) 3 HP 3-Phase (Head loss 30 m)
1
-
-
... More
f) 5 HP 3-Phase (Head loss 30 m)
1
-
-
... More
g) 5 HP 3-Phase (Head loss 30 m)
1
-
-
... More
h) 7.5 HP 3-Phase (Head loss 30 m)
1
-
-
... More
i) 10 HP 3-Phase (Head loss 30 m)
1
-
-
... More
j) 12.5 HP 3-Phase (Head loss 30 m)
1
-
-
... More
Construction of Pump House of size 3.00m x 4.00m X 3.30m
1
-
-
... More
Supplying, fitting, fixing, testing and commissioning of Clear Water Pumping Main (GI pipe) of different diameter a) 150 mm
1
-
-
... More
b) 100 mm
1
-
-
... More
c) 80 mm
1
-
-
... More
d) 65 mm
1
-
-
... More
e) 50 mm
1
-
-
... More
f) 40 mm
1
-
-
... More
Supplying, fitting, fixing, testing & commissioning of Distribution Network with HDPE pipe of different diameter a) 160 mm
1
-
-
... More
b) 140 mm
1
-
-
... More
c) 125 mm
1
-
-
... More
d) 110 mm
1
-
-
... More
e) 90 mm
1
-
-
... More
f) 75 mm
1
-
-
... More
g) 63 mm
1
-
-
... More
h) 50 mm
1
-
-
... More
Construction of RCC supporting pillar for distribution network, Raw Water Gravity Main, Raw Water Pumping Main of different heights from ground level a) 0.5 m
1
-
-
... More
b) 0.8 m
1
-
-
... More
c) 1.0 m
1
-
-
... More
d) 1.2 m
1
-
-
... More
Providing, fitting, fixing 10,000 Litres (i.e. 5000x2) HDPE tank for upto 30 nos. FHTC
1
-
-
... More
Installation of Solar Pumping System of a) 5 HP
1
-
-
... More
b) 7.5 HP
1
-
-
... More
Installation of Solar Pumping System of a) 10 HP
1
-
-
... More
b) 15 HP
1
-
-
... More
c) 20 HP
1
-
-
... More
Supplying, installation, testing and commissioning of DG sets of different capacities a) 5 KVA
1
-
-
... More
b) 7.5 KVA
1
-
-
... More
c) 10 KVA
1
-
-
... More
d) 12.5 KVA
1
-
-
... More
e) 15 KVA
1
-
-
... More
f) 20 KVA
1
-
-
... More
Providing FHTC from the Distribution Network
1
-
-
... More
Construction of Valve Chamber including sluice valve for HDPE Pipe a) 80 mm dia S/V
1
-
-
... More
b) 100 mm dia S/V
1
-
-
... More
c) 125 mm dia S/V
1
-
-
... More
d) 150 mm dia S/V
1
-
-
... More
Supplying, installation, testing of electrically operated chemical dosing pump
1
-
-
... More
Construction of Boundary Wall for Treatment Plant
1
-
-
... More
Supplying, fitting, fixing of Bulk Flow Meter of a) BFM 80
1
-
-
... More
b) BFM 100
1
-
-
... More
c) BFM 125
1
-
-
... More
d) BFM 150
1
-
-
... More
e) BFM 200
1
-
-
... More
Conducting Survey work for laying Raw Water Gravity/Pumping Main and Distribution system under different water supply schemes
1
-
-
... More
Providing Mechanical Tool Box
1
-
-
... More
Providing Electrical Tool Box
1
-
-
... More
Restoration of Paver Block Road of the distribution network
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements