Numaligarh Refinery Limited Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply Of Public Address System
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NRL_812899_1Bid Award Id
ViewTender No
TP/082176C/NRL/PQ/136Tender Authority
Numaligarh Refinery Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Part_II_Technical_Bid_Documents
PART_I_COMMERCIAL_BID_DOCUMENTS
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
ATC_BID_DOCUMENT_ANNEXURES
BOQ Items
... More
Supply of PA system for Building SRR‐4 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 1-11 to 1-18
1
-
-
... More
Supply of PA system for Building SS‐15 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 1-19 to 1-25
1
-
-
... More
Supply of PA System for DHT Unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 2-01 to 2-05
1
-
-
... More
Supply of PA System for Building SRR-3 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 2-06 to 2-14
1
-
-
... More
Supply of PA System for Building SS-11 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 2-15 to 2-21
1
-
-
... More
Supply of PA System for SRB Unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 3-01 to 3-05
1
-
-
... More
Supply of PA System for Building SRR 2 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 3-06 to 3-13
1
-
-
... More
Supply of PA System for Building SS-19 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 3-14 to 3-20
1
-
-
... More
Supply of PA System for RPTU Unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 4-01 to 4-06
1
-
-
... More
Supply of PA System for Building SRR‐5 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 4-07 to 4-13
1
-
-
... More
Supply of PA System for Building SS-16 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 4-14 to 4-20
1
-
-
... More
Supply of PA System for PFCC Unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 5-01 to 5-05
1
-
-
... More
Supply of PA System for GDS Unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 5-06 to 5-11
1
-
-
... More
Supply of PA System for EDG as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 5-12 to 5-17
1
-
-
... More
Supply of PA System for Building SRR‐7 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 5-18 to 5-24
1
-
-
... More
Supply of PA System for MS block as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 6-01 to 6-05
1
-
-
... More
Supply of PA System for Building SRR‐6 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 6-06 to 6-12
1
-
-
... More
Supply of PA System for Utility boiler and HRSG unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 7-01 to 7-05
1
-
-
... More
Supply of PA System for Building SRR 8 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 7-06 to 7-12
1
-
-
... More
Supply of PA System for Building SS‐10 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 7-13 to 7-20
1
-
-
... More
Supply of PA System for Offsites-1 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 8-01 to 8-05
1
-
-
... More
Supply of PA System for Building SRR-9 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 8-06 to 8-13
1
-
-
... More
Supply of PA System for Building SS‐17 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 8-14 to 8-20
1
-
-
... More
Supply of PA System for Offsites 2 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 9-01 to 9-05
1
-
-
... More
Supply of PA System for Building SRR‐10 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 9-06 to 9-13
1
-
-
... More
Supply of PA System for Building SS-18 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 9-14 to 9-20
1
-
-
... More
Supply of PA System for Nitrogen Unit Field areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-01 to 10-05
1
-
-
... More
Supply of PA System for Compressed Air Unit Field areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-06 to 10-10
1
-
-
... More
Supply of PA System for DM & CPU unit field areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-11 to 10-15
1
-
-
... More
Supply of PA System for Cooling tower unit Field areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-16 to 10-20
1
-
-
... More
Supply of PA System for RW filter unit field areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-22 to 10-24
1
-
-
... More
Supply of PA System for ETP unit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-25 to 10-29
1
-
-
... More
Supply of PA System for Flare Unit Field areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-30 to 10-34
1
-
-
... More
Supply of PA System for Firewater reservoir areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-35 to 10-39
1
-
-
... More
Supply of PA System for Raw water storage areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-40 to 10-44
1
-
-
... More
Supply of PA System for Utility Control Room (CR‐2) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-45 to 10-52
1
-
-
... More
Supply of PA System for Utility Control Room (CR‐3) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-53 to 10-60
1
-
-
... More
Supply of PA System for Utility substation (SS‐13) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-61 to 10-67
1
-
-
... More
Supply of PA System for Utility substation (SS‐14) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 10-68 to 10-74
1
-
-
... More
Supply of PA System for MCR-2 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 11-01 to 11-10
1
-
-
... More
Supply of PA System for LCR as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 12-01 to 12-07
1
-
-
... More
Supply of PA System for MCR‐2‐unit field areas (Parking lot) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 12-08 to 12-10
1
-
-
... More
Supply of PA System for Chemical Warehouse/Parking area as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 13-01 to 13-05
1
-
-
... More
Supply of PA System for Warehouse/MCC room as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 14-01 to 14-05
1
-
-
... More
Supply of PA System for LPG loading gantry as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 15-01 to 15-05
1
-
-
... More
Supply of PA System at Flare field area Piperack as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 16-01 to 16-05
1
-
-
... More
Supply of PA System at Fire water pump house as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 17-01 to 17-05
1
-
-
... More
Supply of PA System for around Piperack PR11,PR01, PR16 areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 18-01 to 18-05
1
-
-
... More
Supply of PA System for piperack PR02,PR03, PR4 areas as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 19-01 to 19-05
1
-
-
... More
Supply of PA System at Tankage area Piperack (1S72‐PWS01/PWS02/PWS03, 1S80‐PWS01,1S80‐PR10, 1S80‐PR05, 1S80‐PR06) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5
MR S.No: 20-01 to 20-05
1
-
-
... More
Supply of PA System at Blending Dosing package and DHT tanks pump house(including near 1S80‐PR‐12, 1S80‐PR‐19,1S75‐PR01) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 21-01 to 21-03
1
-
-
... More
Supply of PA System at new gate area as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 22-01
1
-
-
... More
Supply of PA System at NRL Fire Station / Control Room as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5
MR S.No: 23-01 to 23-09
1
-
-
... More
Supply of PA System at Existing RWTP (To be powered/ hooked up with the PA System of CR‐3) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 24-01 to 24-04
1
-
-
... More
Supply of PA System at Main Receiving Sub Station SS‐21 as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 25-01 to 25-09
1
-
-
... More
Supply of PA System for building of HGU as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 26-01 to 26-05
1
-
-
... More
Supply of PA System for Existing ETP Control Room as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 27-01 to 27-04
1
-
-
... More
Supply of PA System at LPG Receipt terminal and Dabidubi Control Room as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 28-01 to 28-14
1
-
-
... More
Supply of PA System at Existing CPP Control Room as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 29-01 to 29-09
1
-
-
... More
Supply of PA System at EIL Crude receipt Terminal and LPG Dispatch terminal as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5 MR S.No: 30-01 to 30-14
1
-
-
... More
Supply of mandatory spares as per “ANNEXURE-VI : LIST OF MANDATORY SPARES TO BE PROVIDED “ of the document TP-1ZZZA-IC-INS-0032 including spares for the servers, networking components etc
(MR S.No: 31) Note: Any other components/hardware for which mandatory spare is required but not available in ANNEXURE-VI : LIST OF MANDATORY SPARES TO BE PROVIDED “ of the document TP-1ZZZA-IC-INS-0032 shall be considered as per spare philosophy and quoted in the offer by system vendor.
1
-
-
... More
Site activities for supervision of installation and erection (atleast 3 months days at site)(with Multiple mobilization / demobilization). Bidder shall consider atleast 3 Engineers+ 6 technical Staff + sufficient assistants (as per bidder's assessment per day shall be deputed by the bidder for this activity) as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5
MR S.No: 33-01 Refer: NOTE-10 in Instruction Note to BOQ
90
-
-
... More
Site service support during unit start‐up/commissioning activity (for pre‐commissioning activities, Configuration, Trouble shooting, correction/ modification etc.) for PA system by deputing a group of system expert (expert/Engineers of OEM / OEM representative and sufficient electrician/technicians (atleast 2 Engineers + 4 Technical staff)) during unit start‐up/ unit commissioning activity(Experts of OEM/OEM’s representative shall be mandatory during unit commissioning period ) till the commissioning and stabilization of the unit operation for a total of 90 days site visit as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5
MR S.No: 33-02 Refer: NOTE-11 in Instruction Note to BOQ
90
-
-
... More
Post SAT service: Bidder shall provide Post SAT service support (Maintenance/ troubleshooting etc.) with resident staff (atleast 1 Engineer+ 2 Technical staff) at site on continuous basis for 1 year from the date of SAT as per MR Ref:TP-1ZZZA-IC-RFQ-0032_D5
MR S.No: 33-03 Refer: NOTE-12 in Instruction Note to BOQ
12
-
-
... More
Training Services for owner personnel (for 10 Engineers) for all items (PA system including bought out item as per MR) at OEM works 3 Man weeks at Vendor works MR S.No:33-05
1
-
-
... More
Training Services for owner personnel (for 15 Engineers + 15 operators) for all items (PA system including bought out item as per MR) at Site MR S.No:33-06 Operation/ maintenance: 10 working days at Site
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements