BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 5,40,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Provision Of Solar Power Plants At Station, Service Buildings, Residential Buildings And Lc Gates Under Jurisdiction Of Sse/elect/dbrt & Nlp.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
LV-T-14-TSK-885-TINSUKIA DIVISION-ELECTRICAL/N F RLYTender No
LV-T-14-TSK-885Tender Authority
Northeast Frontier Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply, fitting, fixing, installation and commissioning of 350 KWp capacity of solar on grid power plant . Contents:-1. 350 KWp Monocrystalline PERC half cut P V Module & solar power conditioning unit(PCU). 2.GI module mounting structure. 3.Lightening Arrestors, Earthing etc. 4. Connecting wires, MCB's, casing pipe, accessories, etc. as required. 5-Grid connected Inverter with MPPT Charge Controller suitable for 350 KWp Solar PV Module. 6-AJB(Array Junction Box), ACDB( AC 004 Distribution Board) with Import- Export Meter,CO2 meter, Power Evacuation system, 7-Transportation Up to the destination. 8- Installation & commissioning included in this work. 9- Insurance & Five Year AMC/CAMC. Civil Works included in the Scope.The Solar Inverter should be equipped with Web based monitoring and control with RTU for real time monitoring of solar generation and other electrical parameters . Daily/monthly/yearly generation data should be available to be downloaded in MS Excel format. The system of Web based monitoring and control should be capable of Switching On and Off the plant remotely and monitor faults,Environmental conditions etc. The communication and other data charges is in the scope of work for period of 5 Years. (4th Pit Line Shed DBRG)
1
16299871
16299871
"Supply, Laying of LT Aluminium Power Cables 120 SQ MM 4 Core, Stranded aluminium conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments .For cable laying Excavation of earth depth 0.75 Mtrs. into breadth 0.58 Mtrs. 005 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024.
200
2120
424000
"Supply, Laying of LT Aluminium Power Cables 70 SQ MM 4 Core, Stranded aluminium conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.For cable laying Excavation of earth depth 0.75 Mtrs. into breadth 0.58 Mtrs. 006 below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024.
350
1391
486850
Supply of All-in One Computer, Processor: 12th Gen Intel CoreTM i5-1235U (up to 4.4 GHz with Intel Turbo Boost Technology, 12 MB L3 cache, 10 cores, 12 threads, OS: Windows 11 Home, 007 Graphics: Intel Iris Xe graphics, Memory: 8 GB RAM DDR4 3200MHz, Storage: 512 GB M.2, Pcle NVMe, SSD(Solid State Drive), Wireless Keyboard & Mouse,Display@58<46@5 cm (23.8 inch) diagonal, FHD (1920 x 1080), VA, three-sided micro-edge, anti-glare .For Use of Online Monitoring of daily solar generation data, maintenance and monitoring of faults etc.
2
64499
128998
Supply, fitting, fixing, installation and commissioning of 2 KWp capacity of solar on grid 001 power plant . Contents:-1. 2 KWp Monocrystalline PERC half cut PV Module & solar power conditioning unit(PCU). 2.GI module mounting structure. 3.Lightening Arrestors, Earthing etc. 4. Connecting wires, MCB's, casing pipe, accessories, etc. as required. 5-Grid connected Inverter with MPPT Charge Controller suitable for 2 KWp Solar PV Module. 6-AJB(Array Junction Box), ACDB( AC Distribution Board) with Import- Export Meter,CO2 meter, Power Evacuation system, 7-Transportation Up to the destination. 8- Installation & commissioning included in this work. 9- Insurance & Five Year AMC/CAMC.Civil works included in the scope. The Solar Inverter should be equipped with Web based monitoring and control with RTU for real time monitoring of solar generation and other electrical parameters . Daily/monthly/yearly generation data should be available to be downloaded in MS Excel format. The system of Web based monitoring and control should be capable of Switching On and Off the plant remotely and monitor faults,Environmental conditions etc. The communication and other data charges is in the scope of work for period of 5 Years.
485
111975
54307875
Supply , installation,testing and commissioning of 1KWP Off-Grid Solar Power Plant. Consisting Of:(1) Solar Inverter Capcity: 1100VA, Single phase, Sine wave, PWM, Charge Controller Rating: 60A, Grid Input Voltage: 90-290V AC Protection: Short circuit, Overload, Over temperature, 001 Low Battery, No Load Shutdown Display: Mains Available, Solar Charging, Grid Charging, Power Saving, System On, Low Battery, Overload (2) Battery: 150AH , 12 V ,Lead Acid Tall Tubular Solar rated capacity @C10-1 No (3) Polycrystalline PV Module , 12V, 170WP-6 Nos. The Work also includes Provision of required Connecting copper cables with PVC pipe from PV array to Solar Inverter, Switch Board with 15A Switch Socket for Grid mains Incoming, required copper cables from Inverter output to load as per direction of Engineer Incharge at Site.
22
125600
2763200
Supply , installation,testing and commissioning of 850WP Off-Grid Solar Power Plant. Consisting Of:(1) Solar Inverter Capcity: 850VA, Single phase, Sine wave, PWM, Charge Controller Rating: 40A, Grid Input Voltage: 90-290V AC Protection: Short circuit, Overload, Over temperature, 002 Low Battery, No Load Shutdown Display: Mains Available, Solar Charging, Grid Charging, Power Saving, System On, Low Battery, Overload (2) Battery: 150AH , 12 V ,Lead Acid Tall Tubular Solar rated capacity @C10-1 No (3) Polycrystalline PV Module , 12V, 170WP-5 Nos. The Work also includes Provision of required Connecting copper cables with PVC pipe from PV array to Solar Inverter, Switch Board with 15A Switch Socket for Grid mains Incoming, required copper cables from Inverter output to load as per direction of Engineer Incharge at Site.
5
108600
543000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%