BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689476_1Tender No
C/8772/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down chowkhats or frame with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as directed.
5
-
-
... More
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed.
200
-
-
... More
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed.
820
-
-
... More
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed.
100
-
-
... More
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed
1
-
-
... More
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and directed
120
-
-
... More
Taking down cement plaster or cement lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed
97
-
-
... More
M&L for surface dressing not exceeding 15 cm deep in soft/loose soil and rubishes to a distance not exceeding 50m including spraying pesticides (roundup or equivalent) to control the grass growth complete all as specified and as directed.
20
-
-
... More
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
51.72
-
-
... More
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
25.08
-
-
... More
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
3047.5
-
-
... More
M&L for Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface with Broken stone or boulders complete all as specified and as directed.
5.7
-
-
... More
M&L for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
0.7
-
-
... More
M&L for PCC (1:3:6), type C2 (using 40mm graded stone aggregates) as in surfaces channels and drains incl necessary formwork complete all as specified and directed.
1
-
-
... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed.
20
-
-
... More
M&L for PCC (1:2:4), type B0 ( using 12.5 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
1.3
-
-
... More
M&L for plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in back filling of pressed steel frame, cills, hold fast, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60cm in height, copings, kneelers, apex stones, bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
0.2
-
-
... More
M&L for providing precast cement concrete Type B0 (1:2:4) (using 12.50 mm graded aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar (1:4) complete all as specified and directed.
7
-
-
... More
M&L for RCC (nominal mix) Type B1 (1:2:4) (20 mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
(Note: Reinforcement shall be measured & paid separately) .
0.6
-
-
... More
M&L for RCC with type B1 (1:2:4) (using 20 mm graded stone aggregate ) in Slabs supported on walls , beams and columns in floors , roofs ., landings, balconies , canopies, deck slabs and in shelves and the like complete all as specified and as directed.
(Note: Steel reinforcement shall be measured & paid separately)
1.5
-
-
... More
M&L for RCC (1:2:4) (nominal mix) type B1 (20 mm graded aggregate) in Beams, cantilevers, bressummer, lintels over 1.5 span complete all as specified and directed.
2
-
-
... More
M&L for RCC (1:2:4) (nominal mix) Type B1 (20 mm graded agg) in column, pillars, piers, post and struts complete all as specified and as directed.
1.2
-
-
... More
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed.
19
-
-
... More
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
162
-
-
... More
M&L for continuous brick edging with burnt clay bricks of sub class B with width equal to the width of the brick; laid dry on end vertically complete all as specified and as directed.
20
-
-
... More
Use and waste of form work to sides of concrete foundations, footings bases of columns below GL and similar work, rough finished surfaces of concrete complete all as specified and directed.
6
-
-
... More
Use and waste of form work to soffits of suspended slabs such as roof slab landings and similar works not exceeding 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and as directed.
12
-
-
... More
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surface of concrete complete all as specified and as directed.
29
-
-
... More
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and as directed.
18
-
-
... More
S&F 35mm thick second class class hard wood glazed and skelton shutter, open rebated and prepared to receive glass gauze etc, divided into squares (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass exc., size of members of shutter as specified in SSR part-I, sec 8 clause 8.24(a), supplied and fitted to chowkats, complete all as specified and directed.
4
-
-
... More
S&F factory made 35 mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
4
-
-
... More
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
5
-
-
... More
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed.
1.5
-
-
... More
S&F for 150 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and as directed.
8
-
-
... More
S&F for 100 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and as directed.
4
-
-
... More
S&F aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
3
-
-
... More
S&F Mild steel butt hinges, Medium grade, 75 mm size , complete all as specified and directed.
4
-
-
... More
S&F Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed.
18
-
-
... More
S&F for aluminium (extruded section body) door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and as directed.
1
-
-
... More
S&F extruded aluminium alloy handles, fabricated type, anodized, 150 mm size , complete all as specified and directed.
12
-
-
... More
S&F extruded aluminium alloy handles, fabricated type, anodized, 100 mm size , complete all as specified and directed.
2
-
-
... More
S&F 150 mm Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed to door complete all as specified and as directed.
5
-
-
... More
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
4
-
-
... More
M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
440
-
-
... More
M&L for TMT bars 6 to 8 mm dia , as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
75
-
-
... More
M&L for TMT bars 6 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
190
-
-
... More
S&F 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hings, lock strike plate etc complete all as specified.
10
-
-
... More
S&F Anodised aluminum section powder coated in partition / frame for door, shutters, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco).
Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper will be measured and paid separately under respective items.
42
-
-
... More
S&F for anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleat glazing clips, rubber neoprene packing handle 2 Nos in each door, hinges, anodised aluminium snap beading screw etc. including powder coating of minimum 50 micron thickness complete all as specified and as directed.
4
-
-
... More
M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium handles 2 numbers in each shutter, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed.
11
-
-
... More
S&F aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed.
Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd.
170
-
-
... More
S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
800
-
-
... More
S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed.
20
-
-
... More
M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded aggregate) thick as in plinth protection/Hard standing , etc finishing cement concrete surface even & fair without using extra cement making joints with bitumastic filling in proportion of bitumen and sand 1:2 complete all as specified and directed.
56
-
-
... More
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed.
78
-
-
... More
M&L for coloured 450x350x7-8 mm thick glazed ceramic tiles on vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick backing coat in cement mortar (1:4) , complete all as specified and directed.
18
-
-
... More
M&L for chequered cement concrete tiles 30cm x 30 cm size, 25 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry in floor with grey cement mixed with pigments to match with the colour of tiles, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
35
-
-
... More
S&F Squash court hard plaster, Maple wooden flooring, Sound board and line marking to squash court wall and flooring, etc with the following specification complete all as per manufacturers instructions and as directed by Eng-in- charge.
(a) Squash Court hard plaster for playing areas only for double court: Supply and application of hard plaster system consisting of a base coat and finish coat of total thickness of 12 mm and coated with washable paint system due to the extremely hard nature of the plaster a slight uneven color distribution and micro porous surface checks may be seen once the plaster has dried. This does not affect the strength or the integrity of the plaster and is not to be considered as a defect. Rebound plaster base + top finish 18 mm thickness. WSF Approved (Area 105.00 sqm)
(b) Maple Wooden Flooring: - Supply, Installation and finishing of Aero Float wooden sports flooring system. Thick 20mm width 60-70mm and random length in tongue and groove shape. The edges of the boards will have groove and the Page bottom side will have air pass groove and with application on polivu lacquer dimension 70mm×45mm treated with anti-termite soluti nd will be fixed on the bottom side with a thickness air-dell cushioning pads by staple through the two wings at 350mm c/c. WSF Approved (Area = 62:00 sqm)
(c) Sound Board: Providing and fixing tin, Sound board of 16 gauges Gl, 17" with teak frame work. (Each: 1 No) (d) : Marking: Squash Court Line marking of wall & flooring (Job:1 No)
Note: All the above (a) to (d) shall be measured and paid as one Job
1
-
-
... More
M&L for 20mm thick granite slabs of any type (table rubbed and polished) on cooking platforms and like, set and jointed in net cement slurry and pointed in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including necessary moulding at edges laid over and including 20mm thick cement mortor screed bed in cement mortor (1:6) complete all as specified and directed.
0.8
-
-
... More
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
2
-
-
... More
M&L for Kota stone slab 18-20mm thick in floor laid over and including 20 mm thick screed bed or bedding layer of cement morter (1:6)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
40
-
-
... More
M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thick rendering as backing coat in cement mortar (1:4) including rubbing and polishing complete all as specified and directed.
10
-
-
... More
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base of flooring complete all as specified and directed.
154
-
-
... More
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
36
-
-
... More
M&L for rendering 5mm thick in cement morter (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
10
-
-
... More
M&L for rendering 10 mm thick wall on other than fair faces of brick work or concrete surfaces in cement mortar in (1:6) and finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
242
-
-
... More
M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar in (1:4) using water proofing compound in top layer and finished even and smooth (without using extra lime or cement) complete all as specified and directed.
Note: Water Proofing Compound measured and paid separately.
285
-
-
... More
Supply only liquid Water Proofing Compound of approved make.
11
-
-
... More
M&L for applying two coats of colour wash on new plastered surfaces of walls, complete all as specified and directed.
72
-
-
... More
M&L for applying two coats of colour wash over a coat of white primer on new plastered surfaces of walls, complete all as specified and directed.
70
-
-
... More
M&L for applying three coats of white wash on new ceiling surface including preparation of surface, complete all as specified and directed.
12
-
-
... More
M&L for applying two coat of white wash on old decorated Ceiling surface including preparation of surface, complete all as specified and directed.
12
-
-
... More
M&L for preparation of old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and greases spots and applying one coat of cement base paint (white or tinted) complete all as specified and as directed.
240
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour with roller over one coat of primer after preparation of surface complete all as specified and directed.
170
-
-
... More
M&L for preparation of plastered surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
190
-
-
... More
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment including chalk whiting on wall etc and applying two coat of distemper oil emulsion over a coat of chalk whiting primer for distemper including wall care putty (minimum 1.5mm thick) complete all as specified and as directed.
80
-
-
... More
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane complete all as specified and directed.
3
-
-
... More
S&F for 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
3
-
-
... More
M&L for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
25
-
-
... More
M&L for preparing of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of aluminium paint complete all as specified and directed.
12
-
-
... More
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings, fixed to wall/ceiling or laid in floor complete all as specified.
87
-
-
... More
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings, fixed to wall/ceiling or laid in floor complete all as specified.
11
-
-
... More
M&L for cutting existing pipe of any size for inserting of TEE for connection of PPR pipe of 32mm dia complete all as specified.
6
-
-
... More
Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and anti microbial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
30
-
-
... More
S&F PP-R gate valves of size 25 mm outer dia (brass insert) connect to PP-R pipe complete all as specified and as directed.
1
-
-
... More
S&F 15 mm bore, bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe complete all as specified and as directed.
1
-
-
... More
S&F Vitreous China wash down water closet pan (pedestal pattern), white with "P" or "S" Trap front or back inlet fixing bolts, PVC seat cover complete and making all necessary connection as specified and directed.
1
-
-
... More
S&F 10Ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
1
-
-
... More
S&F Vitreous China wash hand basin, white, flat back, size 550x400mm with coupling , waste, chain and plug and porcelain stopper, brackets, with and incl 32mm dia 90cm long PVC waste down pipe, but excluding taps complete all as specified and directed.
1
-
-
... More
S&F for 450mm long PVC connections 15mm size with PTMT nuts, complete all as specified and directed.
2
-
-
... More
S&F 15mm cromium plated Bib taps, cast copper alloy with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
7
-
-
... More
S&F cromium plated Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe, complete all as specified and directed.
1
-
-
... More
S&F 15mm dia angular stop cock cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
14
-
-
... More
S&F 110mm bore, PVC (SWR) pipes type 'B', single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
3
-
-
... More
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
2
-
-
... More
S&F PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed.
1
-
-
... More
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
8
-
-
... More
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed
5
-
-
... More
S&F for 110 mm bore, PVC (SWR) vent cowl fixed with solvent cement complete all as specified and as directed.
1
-
-
... More
S&F PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
2
-
-
... More
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
1
-
-
... More
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed.
1
-
-
... More
Supply and fixing in repair 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
1
-
-
... More
S&F 15 mm bore dia stop valves (concealed type), chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
2
-
-
... More
S&F 20 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
8
-
-
... More
S&F ball brass valves of size 20 mm bore high pressure, with polythene float and fly nut, screwed for iron pipe etc complete all as specified and directed.
1
-
-
... More
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 300 mm bore drain pipes complete all as specified and as directed.
6
-
-
... More
M&L for reinforced concrete pipes, class NP2, 300 mm bore, laid and jointed with collars complete all as specified and as directed.
7
-
-
... More
S&F 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated cup washers and screws complete all as specified and as directed.
1
-
-
... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
57
-
-
... More
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
76
-
-
... More
All as per Item No. 114 here in above but for One 2/3 pin socket outlet 5/6Amps on independent board
3
-
-
... More
All as per Item No. 114 here in above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
5
-
-
... More
All as per Item No. 114 here in above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
3
-
-
... More
M&L for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete.
NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
14
-
-
... More
All as per Item No.118 here in above but for One 2/3 pin socket outlet 5/6Amps on independent board
1
-
-
... More
All as per Item No.118 here in above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
1
-
-
... More
All as per Item No.118 here in above but for one switch socket combination 15/16 Amps on independent board with cable 4 sq mm size and earth wire 4 sqmm
1
-
-
... More
S&F Switch piano, flush type, single pole, one way switch 5 Amps ISI marked complete all as specified and as directed.
84
-
-
... More
S&F socket outlet, 2 in 1, 3 pin, 5 Amps, 240V bearing ISI marked complete all as specified and as directed.
7
-
-
... More
S&F Switch socket combination 2 in 1, 5 Amps flush type, ISI marked complete all as specified and as directed.
5
-
-
... More
S&F switch socket out let combination multipurpose 3/5 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed.
11
-
-
... More
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt ISI marked complete all as specified and as directed.
3
-
-
... More
S&F angular/batten holder PVC/Polycarbonate suitable for batten fittings including one LED Lamp of 9W of complete all as specified and directed.
11
-
-
... More
S&F Ceiling rose surface PVC, 3 terminals 65x50mm ISI marked complete all as specified and as directed.
34
-
-
... More
S&F in repair Recess mounted 2x2 ceiling light 42 Watt deep drawn CRCA housing with higher power LED Seamless front frame with flat white hight transmission acrylic cover all as specified and directed. (Make : Havells Cat No PLANO2X2PLR42WLED865S or equivalent model in make Crompton/Phillips/Bajaj)
30
-
-
... More
S&F LED fitting 1x18 watts, 220volts AC decorative box type with driver and of aluminium housing, holder LED tube light conncting up to 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
24
-
-
... More
S&F Bldg light bracket fabricated out of GI Tubing light grade 32 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron size 40X5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including taking down old corroded one all as specified and directed.
2
-
-
... More
S&F 35 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed.
5
-
-
... More
Taking down old unserviceable MCB distribution board of any description and in any position complete all as directed.
4
-
-
... More
S&F of MCB Distribution board TPN 4 Way for mounting SPN/ SP/TPN/TP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed.
1
-
-
... More
S&F of MCB Distribution board SPN 4 Way for mounting SPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed.
4
-
-
... More
S&F of MCB Distribution board SPN 8 Way for mounting SPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed.
2
-
-
... More
Supply and fixing 415volts 10KA B curve MCB of 4 pole 40A current carring capacity complete all as directed by Engr-in-charge.
1
-
-
... More
S&F miniature circuit breaker (MCB) SPN 6 to 32 Amps 'C' Series 10 KA 240 volts complete all as specified and directed.
9
-
-
... More
S&F miniature circuit breaker (MCB) SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and directed.
21
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of dia 4 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.
3
-
-
... More
Supply, fixing and connecting in repair BLDC (26W) ceiling fan 230V, 50 Hz, Copper winding of sweep 1400mm,, connecting with suitable size copper wire complete all as specified and as directed.
30
-
-
... More
S&F Tubes, 'Heavy Grade' galvanised 40mm, with all fitting laid above false ceiling in grid pattern for fan hanging by the support on the walls and fixed on it with the help of PCC complete all as specified and as directed.
66
-
-
... More
S&F mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary gusset plates; riving etc n'exc 10 Kg each brackets conforming to Fe-290 Gde-165 complete all as specified and directed.
14
-
-
... More
Supply, fixing and connecting exhaust fan metal body with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 375mm, including drilling holes in wall for fixing and connecting with suitable size copper wire complete all as specified and as directed.
2
-
-
... More
Taking down old unserviceable submain wiring of any description and in any position complete all as directed.
31
-
-
... More
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed.
Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
175
-
-
... More
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed.
Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
45
-
-
... More
S&F onload change over switch 415V in sheet metal enclosure 4 pole of capacity 63 Amps including all the equipments needed for its installation complete all as specified and as directed.
1
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 10 Sqmm, 4 core, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
41
-
-
... More
Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 10 sqmm 2 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc including taking down complete all as specified and as directed.
200
-
-
... More
Boring of holes horizontal for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.
Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
10
-
-
... More
S&F 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed.
14
-
-
... More
Supply and install 100 kVA, 3 Phase, 4 Wire Automatic Servo Controlled Oil Cooled Voltage Stabilizer 180 Amps per phase 320V to 460V, 47Hz to 63Hz, 4 Wire 400V +/- 1% Overload Cut-Off and Short Circuit Protection. Low/High Voltage (out of input range) Alarm or Cut-Off. Phase Missing / Phase Reversal Alarm or Cut-Off Natural Oil Cooled 1500V AC For 2 Minutes. Greater than 50 Mega Ohms at 500V DC. Digital Multifunction Meter and Manual Bypass & Auto Phase Correction Optional complete all as directed by Engr-in-Charge.
1
-
-
... More
Supply & Install 10KVA-8KW 3Phase UPS With Technology - Sine Wave Technology capacity - 10 KVA
a) Technology - Sine Wave Technology
b) No of battery supported - Ten Battery (12V) with battery stand.
c) Space vector modulation
d) High efficiency
e) Inbuilt galvanic isolation transformer
f) Surge protections on LT side
g) MODBUS remote monitoring.
h) input side PFC power factor corrector
j) VTHD is less than 3%
k) Static switch transfer technology
l) Manual bypass switch available for maintenance and service
m) User friendly LCD display
n) Lithium-ion battery compatibility
1
-
-
... More
Supply laying and tersting PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq 3.5 core complete all as directed by Engr-in-charge.
20
-
-
... More
M&L for clear sand cushioning for protection of cable complete all as specified and directed. (only punned down thickness to be measured)
19.94
-
-
... More
Supply and laying well burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of suitable size available in market to cover LT underground cables, laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
1427
-
-
... More
S&F for water heater storage type, electric, steel body with copper inner tank and heating element upto 2KW, capacity 25 liters, BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and as directed.
Make : Crompton Greves/Bajaj/Havells.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%