Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 72,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692485_1Tender No
GE(N)/TEZ/2024-2025/8990Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fix in repair CT for measuring AC on LT 3 phase system, 1.1 kv grade, single burden, general purpose, of CT ratio as per site requirement. complete all as specified and directed. Make : As per sample
12
-
-
... More
Supply and fix in repair LED Indicator Lamps for phases including holders and of colours red / yellow / green / blue etc. complete all as specified and directed. Make : As per sample
12
-
-
... More
Supply and fix in repair Selector Switch (cam type) suitable for Ammeter / Voltmeter complete all as specified and directed. Make : As per sample
12
-
-
... More
S& F copper bus bar duly insulated with 1100 V grade standard colour coded PVC sleeves and size of bus bar as per site requirement complete all as directed and specified by Engr-in-charge.
10
-
-
... More
S& F Aluminium bus bar duly insulated with 1100 V grade standard colour coded PVC sleeves and size of bus bar as per site requirement complete all as directed and specified by Engr-in-charge.
10
-
-
... More
S & F in replacement of MCCB 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal magnetic tripping system against over load and short circuit conditions of capacity 400 Amps complete all as specified and directed.
2
-
-
... More
S & F in replacement of MCCB 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal magnetic tripping system against over load and short circuit conditions of capacity 250 Amps complete all as specified and directed.
2
-
-
... More
S & F in replacement of MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal magnetic tripping system against over load and short circuit conditions of capacity 200 Amps complete all as specified and directed.
2
-
-
... More
S & F in replacement of MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal magnetic tripping system against over load and short circuit conditions of capacity 160 Amps complete all as specified and directed.
2
-
-
... More
S & F in replacement of MCCB 415 volt, AC 50 Hz, 4 pole, 16 KA with adjustable thermal magnetic tripping system against over load and short circuit conditions of capacity 63 Amps complete all as specified and directed.
4
-
-
... More
S & F in replacement of MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal magnetic tripping system against over load and short circuit conditions of capacity 100 Amps complete all as specified and directed.
4
-
-
... More
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified.
497
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
226
-
-
... More
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
271
-
-
... More
M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
149
-
-
... More
M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed.
14
-
-
... More
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
50
-
-
... More
Taking down old u/s LT UG Cables/ service wire of any size from trenches/poles/walls complete after disconnection all as specified and directed
2630
-
-
... More
M&L relaying serviceable LT cable of any size complete all as specified and directed by Engr-in-charge. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
400
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth strip size of 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion, complete all as specified and directed.
20
-
-
... More
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 10 Sq mm cross sectional area, 2 core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
920
-
-
... More
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 16 Sq mm cross sectional area, 4 core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
800
-
-
... More
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 25 Sq mm cross sectional area, 4 core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
100
-
-
... More
M&L for Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of 95 Sq mm cross sectional area, 3½ core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- 1.Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items.
260
-
-
... More
M&L for Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of 120 Sq mm cross sectional area, 3½ core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- 1.Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items.
150
-
-
... More
S&F in repairs Galvanised mild steel tubing, 'Light grade' of 40mm bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified (Note :- Excavation & Earth work shall be measrued and paid separately)
42
-
-
... More
S&F in repairs Galvanised mild steel tubing, 'Light grade' of 80mm bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified (Note :- Excavation & Earth work shall be measrued and paid separately)
24
-
-
... More
Material and labour junction boxes with new Thermoplastic Cable Junction Boxes IP66/67 "weather proof" , for outdoor installation with knockouts for cable entry with terminals suitable for 10-16sqmm cable off Size 155 X 210 X 92 mm incl busbar fixed in repairs and including Necessary civil works and connecting all incoming and outgoing wires with AL lugs of appropiate sizes and complete all as specified and directed by Engr-in-Charge. Make Cat No. KF1616G of Hensel or euivalent
40
-
-
... More
S&F in replacement 1100 volts grade PVC insulated weather proof sheathed copper cable 1.5 sqmm size 3 core fixed with RCC/Steel tubular pole including PVC conduit medium grade 19/20 mm dia complete all as specified and directed.
410
-
-
... More
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.2x0.6x1.2)m, angle iron of size 50X50X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 250 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS :MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete.MCCB 4 pole, 415 Volts, 200 Amps, 25 kA for out going -02 Nos MCCB 4 pole, 415 Volts, 160 Amps, 25 kA for out going -01 Nos MCCB 4 pole, 415 Volts,63 Amps, 16 kA for out going -02 Nos INSTRUMENTATION SYSTEM :(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
2
-
-
... More
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.2x0.6x1.2)m, angle iron of size 50X50X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 500 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 315 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS :MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete.MCCB 4 pole, 415 Volts, 250 Amps, 25 kA for out going -02 Nos MCCB 4 pole, 415 Volts, 200 Amps, 25 kA for out going -01 Nos MCCB 4 pole, 415 Volts,63 Amps, 16 kA for out going -01 Nos INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
1
-
-
... More
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.2x0.6x1.2)m, angle iron of size 50X50X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 250 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 200 Amps, 25 kA for out going -01 Nos MCCB 4 pole, 415 Volts, 160 Amps, 25 kA for out going -04 Nos MCCB 4 pole, 415 Volts,63 Amps, 16 kA for out going -01 Nos INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
1
-
-
... More
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.6x0.6x1.6)m, angle iron of size 40X40X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 250 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 160 Amps, 25 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 100 Amps, 16 kA for out going -02 No MCCB 4 pole, 415 Volts, 63 Amps, 16 kA for out going -01 Nos INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
1
-
-
... More
Supply, install, testing & commissioning of LT busbar chamber of size (1.0x0.60x0.60)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos Aluminium 400 A rated not less than 20mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 250 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
3
-
-
... More
Material and labour for painting of pole number using stensils of letter size 75mm height with white synthetic enamel paint over black background complete all as specified and directed.
700
-
-
... More
M&L for Cleaning of electric substation by uprooting unwanted grass, bushes and trimming of branches, surface dressing not exc.15cms deep in loose/soft soil to cut the grass,throne busehs and other any type of grass upto root level surrounding the installation and depositing the same at nearby garbage pit, refreshing and re-spreading aggregates inside the premises of sub station if any including cleaning of road/path/fencing etc, maintenance of transformer platform all as specified and directed.
500
-
-
... More
Material & Labour for complete load balancing of each transformer LT Supply by analysing data and reconnecting of load as per requirement to balance the load, the diconnection of cable from ACSR LT poles, cable etc to be done by taking proper shutdown to avoid any unwated condition complete connection in all respects as diected by engr-in-charge. The quoted rate shall include the cost of electrical and instruments/tools required during load balancing by the skilled electricians.
25
-
-
... More
M&L for shifting of LT pole from one place to another under the AOR of AGE E/M Solmara including excavation and PCC work for dismatling/erection of LT pole all as specified and directed by Engr-in-Charge. Note: Necessary T&P and transportation shall be demed to be included in the quoted rate.
6
-
-
... More
M&L for shifting of LT panel/bus bar chamber from one place to another under the AOR of AGE E/M Solmara including excavation and PCC work for dismatling/installation of LT panel/ bus bar chamber including necessary discnnection and reconnection of LT cables all as specified and directed by Engr-in-Charge. Note: Necessary T&P and transportation shall be demed to be included in the quoted rate.
6
-
-
... More
M & L for preparing and painting on steel tubular swaged pole 410 SP-31 (9.00 metre long) including cross arms, GI brackets with one coats of aluminium paint over existing painted surface on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer using single coat of synthetic enamel paint over existing painted surface complete all as specified and as directed.
400
-
-
... More
Material and labour for painting to PCC pole (8.50/9.00 metre long) surfaces with single coat of cement based paint over existing painted surface and 30 cm alternative black and yellow strips and remaining portion up to 1.20 metre height from ground level including MS frames like channel,clamps, angle, D-clamps etc with single coat of synthetic enamel paint of suitable colour complete all as specified and directed.
300
-
-
... More
Labour only for carrying out Maintenance/servicing of 100 KVA DG set of capacity of Make:- Kirloskar/Bliss/Mahindra & Mahindra/etc. Note: (I) Maintenance of DG set to be carried out as per manufacturers instructions or as requirement by qualified service engineer . (II) Materials/Spare parts/Lub oil required for above maintenance shall be measured and paid seperately under repective items as "Supply only Materials" complete all as specified and directed.
2
-
-
... More
Labour only for carrying out Maintenance/servicing of 62.5 KVA DG set of capacity of Make:- Kirloskar/Bliss/Mahindra & Mahindra/etc. Note: (I) Maintenance of DG set to be carried out as per manufacturers instructions or as requirement by qualified service engineer . (II) Materials/Spare parts/Lub oil required for above maintenance shall be measured and paid seperately under repective items as "Supply only Materials" complete all as specified and directed.
2
-
-
... More
Labour only for carrying out Maintenance/servicing of 15 KVA DG set of capacity of Make:- Kirloskar/Bliss/Mahindra & Mahindra/etc. Note: (I) Maintenance of DG set to be carried out as per manufacturers instructions or as requirement by qualified service engineer . (II) Materials/Spare parts/Lub oil required for above maintenance shall be measured and paid seperately under repective items as "Supply only Materials" complete all as specified and directed.
1
-
-
... More
Supply only of Lub Oil of specific grade (20W40 or Eqv.) for carrying maintenance. Make-Kirloskar/ Servo pride(IOC)/Castrol/Veedol or Equivalent any make / recommended by manufacturer complete all as specified and directed.
80
-
-
... More
Supply only of Premix Coolent of radiater water for carrying maintenance .Make Bharat/Greaves or Equivalent any make / recommended by manufacturer complete all as specified and directed.
20
-
-
... More
Supply only for filling of Distilled Water for Batttery complete all as specified and directed.
50
-
-
... More
Supply only of Lub Oil filter(Mobil oil) element with 'O' ring, for carrying maintenance for the DG set of 100 KVA capacities complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
Supply only of Lub Oil filter(Mobil oil) element with 'O' ring, for carrying maintenance for the DG set of 62.5 KVA capacities complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
Supply only of Lub Oil filter(Mobil oil) element with 'O' ring, for carrying maintenance for the DG set of 15 KVA capacities complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Supply only of Lub oil turbo filter element with O ring for carrying maintenance for the DG set of 100 KVA capacities complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
Supply only of Fuel filter (Diesel filter) element with 'O' ring, for carrying maintenance for the DG set of 100 KVA capacities complete all as specified and directed by Engr-in-Chrage.
4
-
-
... More
Supply only of Fuel filter (Diesel filter) element with 'O' ring, for carrying maintenance for the DG set of 62.5 KVA capacities complete all as specified and directed by Engr-in-Chrage.
4
-
-
... More
Supply only of Fuel filter (Diesel filter) element with 'O' ring, for carrying maintenance for the DG set of 15 KVA capacities complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set of 100 KVA capacities complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set of 62.5 KVA capacities complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set of 15 KVA capacities complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Taking down worn out and Replacement of Belt for fan ,dynamo and radiator for 100 KVA DG set complete all as specified and directed by Engr-in-Chrage.
4
-
-
... More
Taking down worn out and Replacement of Belt for fan ,dynamo and radiator for 62.5 KVA DG set complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
Taking down worn out and Replacement of Belt for fan ,dynamo and radiator for 15 KVA DG set complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Takingowt and repair / Maintenance of Water Pump Including replacement of complete assembly as Gasket, Bearing,Hose pipe, rubber seal & clamp etc of 100 KVA DG Sets of capacity complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Taking downt and repair / Maintenance of Water Pump Including replacement of complete assembly as Gasket, Bearing,Hose pipe, rubber seal & clamp etc of 62.50 KVA DG Sets of capacity complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Taking downt and repair / Maintenance of Water Pump Including replacement of complete assembly as Gasket, Bearing,Hose pipe, rubber seal & clamp etc of 15 KVA DG Sets of capacity complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt armature, rewinding of coils, replacement of pinion gears etc for the DG set of capacity 30 KVA. complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt armature, rewinding of coils, replacement of pinion gears etc for the DG set of capacity 62.5 KVA. complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt armature, rewinding of coils, replacement of pinion gears etc for the DG set of capacity 100 KVA. complete all as specified and directed by Engr-in-Chrage.
1
-
-
... More
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set varying from 15-100 KVA complete all as specified and directed by Engr-in-Chrage.
4
-
-
... More
M & L and servicing of turbo charger set with connecting pipe , bearing set , oil seal , ring , bushes etc for the various capacity of DG set varying from 15-100 KVA complete all as specified and directed by Engr-in-Chrage.
2
-
-
... More
M & L for opening and dismantling of cylinder head and connected accessories etc after complete of work including re-assemblying the head and tapit valve setting etc, repalcing the complete gasket set etc all as directed by Engineer-in-Charge.Note :-(i) Spare parts shall be measured and paid separately under respective item of this sch . (ii) Minor spare parts, which are essential for carrying out repair works but specifically not included in the description of item shall also deemed to be included in the unit rate. (iii) The rate quoted shall be deemed to be inclusive of cleaning using chemicals, cutting, grinding, rematling, polishing, and lathe work required if any . Supply only Following spare parts.
1
-
-
... More
Supply only Piston for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only Piston pin for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only Piston ring for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only Piston liner for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only main bearing for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only con rod bearing for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only con rod bush for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only valve internal/external for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only valve guide,seat,lock for 100 KVA DG Set complete all as specified and directed.
1
-
-
... More
Supply only head gas kit for 100 KVA DG Set complete all as specified and directed.
1
-
-
... More
Supply only injector nozzle for 100 KVA DG Set complete all as specified and directed.
6
-
-
... More
Supply only ring gear for 100 KVA DG Set complete all as specified and directed.
1
-
-
... More
Labour for cleaning ( twice during contract period in each DG set) of DG set fuel tank of capacity upto 100 KVA by draining out residual oil and removal of sludge from bottom of the tank complete all as directed.
10
-
-
... More
Supply, fix, testing and commissioning new 12 Volts, 150 AH Battery including removing existing unserviceable one complete all as directed. Make :- Exide, Amco, Nicco, Amaron or any other equivalent make as approved by GE
2
-
-
... More
Material and Lbour in repair/replacement of Chage over switch manual type of 3 phase 415 v, 200 amp all as specified and as directed
1
-
-
... More
Labour only for attending breakdowns of DG sets/ panels through skilled technician or reputed service centre technician of DG sets with necessary tool kits, checking minor fault in Engine and alternator , carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load complete all as directed. Note : 1. Necessary spares required to rectify the defects shall be measured and paid separately as supply only under relavant items. 2. The complaint shall be attended and rectifed within 24 hours from time of reporting by Engr-in-Charge or his authorised representative. 3. Any Major defects shall be reported on priority to Engr-in-Charge to avoid undue delay in fuctioning of installation.
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%