Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673597_1Bid Award Id
ViewTender No
8517/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling Insulators any type, any size complete all as specified and as directed.
400
-
-
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
945
-
-
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
541
-
-
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
404
-
-
M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
284
-
-
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
33200
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
150
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
100
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
200
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sqmm 4 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
4000
-
-
S&F three phase street light panel astronomical type with maximum load 12KW contactor rating 65 Amps three pole with MCB TPN 63 Amps, including Taking down Unserviceable street light panel switch complete all as specified and as directed.
2
-
-
S&F 2.5Sqmm PVC insulated weather proof, sheathed,3 core, multistranded copper conductor run through pole/pipe for connection from junction box to light fitting connector block complete all specified & as directed.
945
-
-
S&F Junction Box for Street Lights of size 205x255x112 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66/67 protection and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on security light pole with suitable bracket nuts, bolts including removal of exiting unserviceable all as specified and directed. Note :- Cable glands shall be fixed in inlet and out let of junction box and rate of Cable glands is deem to be included in quoted rate.
100
-
-
M&L cutting PCC/Hardstanding/Road Surfaces not exc 20cm width and depth not exc 45cm, for passing out UG cable, Returning, filling in,removing surplus soil and making good the distrubed surfaces using PCC minimum thickness 15cm using Type C1 (I:3:6) 20mm graded aggregate complete all as directed.
50
-
-
S&F in repair GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
35
-
-
S&F in repair GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
35
-
-
S&F in repair GI Tubing light grade of size 40mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
130
-
-
M&L earthing complete with copper Earth Plate Electrode 600mm x 600mm x 3.15mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to Copper earth strip 32X6 mm drawn through and including Galvanised Iron protection Pipe 40 mm bore (dia) Light grade up to height of the transformer foundation where transformer is situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.
7
-
-
Design, fabricate ,Supply, installing, testing and commisioning of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC 1:3:6 using 40mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 415Volts AC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables including taking down old unserviceable panel box
Busbar: 240 Amps rated Aluminum busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance.
Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : -
(a) INCOMING
(i) MCCB 160 Amps, 4 pole, 415 Volts (Ics=100%Icu), 36 kA - 1 No
(ii) Digital ammeter with 3 Nos CTs & selector switch - 1set (iii) Digital Voltmeter with selector switch - 1 set (iv) R ,Y , B indicator Lamps 1 Set
(b) OUTGOING
(i) MCCB 63 Amps 4 Pole , 415 Volts (Ics=100%Icu),, 25 kA - 01 Nos
2
-
-
Evaluation Notes How It Works ?