Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Solid Waste Management
Eprocure
Opening Date10 Dec 2024
Closing Date30 Dec 2024
Tender Amount₹ 38,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning filling in soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exc. 25 cm, complete all as specified and directed.

149.2

-

-

... More
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.

158.47

-

-

... More
Material and labour for, sand filling under floors or in foundations or cushioning for interlocking tiles including watering and consolidation, complete all as specified and directed.

65.9

-

-

... More
Material and labour for, hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.

72.63

-

-

... More
Materials and labour for, plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.

28.84

-

-

... More
Material and labour for, RCC M25 (Design Mix) (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.

22.24

-

-

... More
Material and labour for, brickwork with subclass ‘B’ bricks, old size, straight or curved on plan exc. 6m mean radius built in cement mortar (1:6), complete all as specified and directed.

78.3

-

-

... More
Material and labour for,25mm thick damp proof course in cement mortar (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) to horizontal or vertical surfaces mixing with water proofing compound as per manufacturer's instruction including necessary formwork, complete all as specified and directed. (Note: Water proofing compound shall be measured and paid seperately under relevant item).

22.68

-

-

... More
Material and labour for, use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete, complete all as specified and directed.

0.95

-

-

... More
Material and labour for, use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete, complete all as specified and directed.

50.91

-

-

... More
Material and labour for, use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, complete all as specified and directed.

12.6

-

-

... More
Supply and fix for, mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5cm long and dis of bolt 5 to 10mm, complete all as specified and directed.

33.6

-

-

... More
Supply and fix for, rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde-E- 250) quality-A, complete all as specified and directed.

158.76

-

-

... More
Supply and fix for, rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including cutting, welding etc conforming to Fe 410-W (Gde-E- 250) quality-B, complete all as specified and directed.

2943.45

-

-

... More
Supply and fix for, rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.

2025.44

-

-

... More
Material and labour for, mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.

1063.3

-

-

... More
Material and labour for, mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.

443.3

-

-

... More
Supply and fix for, pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.

203.69

-

-

... More
Supply and fix for, pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.

28.8

-

-

... More
Material and labour for, 100mm thick plain cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base floor, complete all as specified and directed.

200

-

-

... More
Material and labour for, 100mm thick plain cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in floor laid in alternate panels finished even and smooth without using extra cement, complete all as specified and directed.

200

-

-

... More
Supply and fix for, 3mm thick and 28mm wide glass dividing strips as in floor inserted in position, conforming to design, complete all as specified and directed.

130

-

-

... More
Materials and labour for, rendering 10 mm thick, cement plaster, in cement mortar (1:6) on fair faces of brick work or concrete surfaces on walls and finished even and smooth without using extra cement, complete all as specified and directed.

150.45

-

-

... More
Materials and labour for, rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound @3% by weight of cement over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. (Note: Water proofing compound shall be measured and paid seperately under relevant item).

226.02

-

-

... More
Supply only integral water proofing compound complete all as specified.

4

-

-

... More
Material and labour for, 75mm thick plain cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection laid in panel, finished even and smooth without using extra cement, complete all as specified and directed.

68.36

-

-

... More
Material and labour for, forming Contraction (Dummy) joints 100mm deep x 10mm wide, filled with sealing compound grade 'A', complete all as specified and directed.

118

-

-

... More
Material and labour for, machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and directed.

213.2

-

-

... More
Material and labour for, preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat primer, complete all as specified and directed.

485.25

-

-

... More
Material and labour for, preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.

160.17

-

-

... More
Material and labour for, point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable 1100 volts grade, ISI 694 marked of size 1.5 Sqmm draw in and including PVC casing and capping (heavy duty, ISI marked) of required size with all necessary fittings such as bends, cross, elbow, tees etc. with MS pressed steel cadmium plated terminal box not less than 1.2mm thick for mounting switches, sockets, fan regulator etc. and 3mm thick laminated sheet top cover (ISI marked) including 1.5 Sqmm PVC insulated unsheathed stranded FRLS copper conductor as continuous earth wire and connected to common earth dolly for one light/ ceiling fan/ exhaust fan/ buzzer controlled by one, one way switch, complete all as specified and directed.

4

-

-

... More
Material and labour for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 4.0 Sqmm in and including PVC rigid concealed conduit (heavy duty) of required dia with all necessary fittings including 4.0 Sqmm PVC insulated unsheathed stranded FRLS copper conductor as earth lead and connected to common earth dolly for one modular socket outlet 5 pin 15/16 Amps on independent board, complete all as specified and directed. Notes:-For industrial socket. Rates shall be measured and paid sepertely under relevant item.

2

-

-

... More
Material and labour for, earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth strip 32x6.0mm by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete earth pit in PCC (1:3:6) type C1, 50mm thick pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) cover slab (Reinforced with 8mm dia TMT bar @15cm centre to centre bothways and suitable handle made of 10mm dia), provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers of 15cm (compacted thickness), 40mm bore galvanised steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including testing on completion. (Note: GI earth wire and protection pipe upto 7.5metres shall be deemed to be included in the unit quoted rate).

2

-

-

... More
Supply and fix for, modular switch 1 way 6A, 1 module, complete all as specified and directed.

5

-

-

... More
Supply and fix for, industrial socket three phase and neutral 415 volts, complete all as specified and directed.

2

-

-

... More
Supply and fix for, VTPN DB double door, 4 way, 415 volts IP-43 protection with door earthing and mechanical impact strength IK08, complete all as specified and directed.

1

-

-

... More
Supply and fix for, MCCB 63 Amps, 415 volts, 25 KA, 4 pole, complete all as specified and directed.

1

-

-

... More
Supply and fix for, LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. Make:- Havells cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent model of make as specified in PS.

4

-

-

... More
Supply and fix for, LED flood light 120 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as per Cat No.TRP-411-120-57-HL2-GL-NSG of Crompton or equivalent model of make as specified in PS, complete all as specified and directed.

5

-

-

... More
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved), out door type, dust and vermin proof feeder pillar box made out of 3.15mm thick CRCA steel sheet of suitable size with angle iron of 40mm x 40mm x 6mm, powder coated over a coat of red oxide primer suitably grouted in PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) including aluminium bus bar of 200 Amps, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here-in-under and also suitable for operation on AC 415 volt, 3 phase, 50Hz supply system including disconnecting of electric connection both incoming and out going from existing unserviceable feeder pillar boxes/ bus bar enclosers and accessories and taking out panel from the foundation. The feeder pillar box shall comprises of following items and all as specified in SSR Part-I, clause No.19.21 and as shown on drawing. INCOMING:- (i) MCCB 63 Amps, 4 pole, 415 volts, 18 KA - 01 No. Cat No.CM90518OOHO of L&T make. (ii) Digital multifunction meter - 01 No. Cat No.WL441010OOOO of L&T make. (iii) LED phase indicator lamp (RYB) - 01 set of 3. OUTGOING:- (i) MCCB 40 Amps, 4 pole, 415 volts, 18 KA - 01 No. Cat No.CM90518OOFO of L&T make. (ii) MCB 40 Amps, TPN, 415 volts, 10 KA - 01 No. (iii) Motor protection relay - 01 No. (iv) Spare compartment - 01 No.

1

-

-

... More
Supply and fix for, sub main wiring with two runs of single core 4.0 Sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed, 1100 volts grade IS-694 marked drawn through and including PVC casing & capping medium duty (ISI marked) of required size with all accessories such as junction boxs, bends, tees etc. including one run of single core 4.0 Sqmm (nominal area) PVC insulated copper conductor FRLSH, unsheathed stranded as continuous earth wire, complete all as specified and directed. Notes: All runs of copper conductor and one run of casing & capping shall be measured as one unit length.

50

-

-

... More
Supply, laying, testing commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core, complete all as specified and directed.

180

-

-

... More
Supply and fix for,galvanised iron srtip of size 25x4mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point, complete all as specified and directed.

20

-

-

... More
Material and labour for, sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. (NOTE : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for).

12.24

-

-

... More
Material and labour for, sub class 'B' brick, well burnt, old size, flat, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.

1.36

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.