Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_201136_1Bid Award Id
ViewTender No
NIT No 8001/104/01/E8 2018-2019Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Split type AC of capacity upto 2.0 TR all as specified and directed.
10
-
-
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Refrigerator of capacity upto 340 Litres all as specified and directed.
1
-
-
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Water Cooler of Capacity 40 Litres to 150 Litres all as specified and directed.
5
-
-
Taking out defective blower motor from Window type AC of capacity 1.0/1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
10
-
-
Taking out defective blower motor from Split type AC of capacity 1.0/1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
6
-
-
Taking out defective blower motor from Water Cooler of capacity upto 150 Litres and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
4
-
-
Labour only for collecting the complaints of various wards/departments etc pertaining to Split/window type ACs of any capacity/make from concerned JE E/M of AGE E/M, attendending these at site to asses the actual fault after opening of ACs and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE E/M all as directed. Note :- Spare parts shall be measured and paid separately under appropriate Items Nos. 10.01 to 10.19 here-in- after.
80
-
-
Supply only running capacitor of capacity 36 Mfd in plastic container complete all as directed.
18
-
-
Supply only running capacitor of capacity 4 Mfd in plastic container complete all as directed.
18
-
-
Supply only Capillary Tube (Copper) of size same as existing complete all as directed.
20
-
-
Supply only Filter Strainer complete all as directed.
5
-
-
Supply only starting relay for 1.00/1.5/2.00 TR compressor all as directed.
5
-
-
Supply only Selector Switch for Window/Split type AC complete all as specified.
6
-
-
Supply only Air filter made out Plastic frame and Nylon net suitable for any capacity split AC of any Make and model all as directed.
6
-
-
Supply only Thermostat Switch complete all as directed.
8
-
-
Supply only Contactor Relay suitable for any capacity split AC of any Make and model all as directed.
6
-
-
Supply only running capacitor of capacity 45/50 Mfd + 6 Mfd in plastic container complete all as directed.
40
-
-
Supply only Blower Motor for Window type AC upto 2 Ton Capacity complete all as directed.
6
-
-
Supply only Blower Motor for Split type AC upto 2 Ton Capacity complete all as directed.
6
-
-
Supply only front grill for window type AC of 1.0/1.5/ 2.0 TR complete all as directed.
4
-
-
Supply only PCB Board for Split type AC complete all as directed.
12
-
-
Supply only Rubber bushing for blower motor for Window/Split type AC of any capacity complete all as directed.
6
-
-
Supply only Swing motor for split type AC of capacity 1.0 TR/1.5TR/2.0TR complete all as directed.
4
-
-
Supply only Display assembly for spilit type AC of any capacity complete all as directed.
4
-
-
Supply only Starting capacitor of capacity 100/120 mfd in plastic/metal container complete all as specified and directed.
18
-
-
Supply only Sensor for Indoor unit of Window/Split type AC any capacity complete all as directed.
5
-
-
Supply and fixing in repair Sealed unit Compressor reciprocating type for Window/Split type AC of 1.5 Ton capacity complete all as directed.
2
-
-
Supply and fixing in repair Sealed unit Compressor reciprocating type for Window/Split type AC of 2 Ton capacity complete all as directed.
2
-
-
Supply and fixing in repair Sealed unit Compressor rotary type for Window/Split type AC of 1.5 Ton capacity complete all as directed.
2
-
-
Supply and fixing in repair Sealed unit Compressor rotary type for Window/Split type AC of 2.0 Ton capacity complete all as directed.
3
-
-
Supply and fixing in repair Refrigerator compressor for Refrigerator of capacity upto 260 Ltrs complete all as directed.
2
-
-
Supply and fixing in repair Water cooler compressor for Water Cooler of capacity above 40 litres and up to 150 ltrs complete all as directed.
4
-
-
Supply and fixing in repair Refrigerator compressor for Refrigerator of capacity above 260 litres and upto 440 Ltrs complete all as directed.
1
-
-
Supply and fixing in repair flexible drain pipe including provision of necessary accessories for fixing of drain pipe and testing complete for proper functioning for split type AC all as specified and directed.
30
-
-
Labour only for collecting the complaints of various wards/departments etc pertaining to Refrigerators of any capacity/make from concern JE E/M of AGE E/M, attendending these at site to asses the actual fault after opening of refrigerator and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE E/M all as directed. Note :- Spare parts shall be measured and paid separately under appropriate Item Nos. 19.01 to 19.14 here-in-after.
6
-
-
Supply only Condenser coil.
2
-
-
Supply only Pin/Thread type lamp holder.
2
-
-
Supply only Bulb 15 watt (Pin/Thread type).
2
-
-
Supply only Ice tray.
2
-
-
Supply only Open type relay with overload protector.
2
-
-
Supply only Thermostat auto defrost.
2
-
-
Supply only Capillary tube (copper) as per existing.
2
-
-
Supply only Chill tray.
2
-
-
Supply only Ice Chamber for Refrigerator of capacity up to 340 Ltr.
2
-
-
Supply only Vegetable box.
2
-
-
Supply only Bimetal Relay.
2
-
-
Supply only Heating Element.
2
-
-
Supply only Frost free fan motor.
2
-
-
Supply only Timer.
2
-
-
Labour only for collecting the complaints of various wards/departments etc pertaining to Water Coolers of any capacity/make from concern JE E/M of AGE E/M, attendending these at site to asses the actual fault after opening of water coolers and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE E/M all as directed. Note :- Spare parts shall be measured and paid separately under appropriate Item Nos. 20.01 to 20.11 here-in- after.
12
-
-
Supply only Push type tap copper alloy chromium plated 15 mm bore.
5
-
-
Supply only Rubber lining for top cover gasket (3 metre approx each cooler).
5
-
-
Supply only Starting relay suitable for 5/8 HP motor.
5
-
-
Supply only Starting capacitor 80/100 mfd.
5
-
-
Supply only Thermostat.
5
-
-
Supply only Float valve Brass with fly nut screwed as per existing.
5
-
-
Supply only Over load protector.
5
-
-
Supply only Capilary tube as per existing size (Copper).
5
-
-
Supply only Blower motor as per existing.
5
-
-
Supply only CP Basin tray.
5
-
-
Supply only Running capacitor 15 mfd.
5
-
-
Supply and charging refrigeration gas F-22 for Split/window AC/water cooler all as specified and directed.
65
-
-
Dismantling, shifting and refixing of split type AC of capacity 1.5 to 2.0 TR including proper arrangement to keep outer unit (Angle iron with nut bolt) and excluding gas charging as required type of refrigerant in the unit complete all as specified and directed.
5
-
-
Supply and fixing in repair sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt complete all as specified and directed.
6
-
-
Taking down out door unit of Split type AC 1.5TR/2.0 TR capacity removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket in repair (including two coats of paint over a red oxide primer) fixing to the wall by foundation bolts refixing the out door unit connecting the suction and discharge line complete inluding testing for efficient running complete all as directed.
8
-
-
Taking out Voltage Stablizer of capacity upto 2 KVA, transporting it to workshop, dismantling transformer unit, auto transformer barrier, electric circuit board etc with all cable connections carrying out repair/replacement of push on switch, transistor, capacitor, relay transistor, diode, condensor, voltmeter, PVC connector, indicator lamp, cut out, MCB etc , testing and commisioning to make it fully functionable complete all as directed.
5
-
-
Taking out Voltage Stablizer of capacity upto 3 KVA to 5 KVA, transporting it to workshop, dismantling transformer unit, auto transformer barrier, electric circuit board etc with all cable connections carrying out repair/replacement of push on switch, transistor, capacitor, relay transistor, diode, condensor, voltmeter, PVC connector, indicator lamp, cut out, MCB etc , testing and commisioning to make it fully functionable complete all as directed.
18
-
-
Taking down geyser of 50/35/25 ltrs capacity from its position after disconnecting water connections, opening of geyser to take out inner tank, examining the points of leakage and soldering the points to stop leakage, scraping and brushing down old paint with emery paper, applying two coats of white paint using spray machine spray painting and writing of MES No by black paint, complete all as specified and as directed.
45
-
-
Dismantling of existing unserviceable apparatus plate from Geyser of 50 litres capacity and Supply and fixing in repair new copper apparatus plate of same thickness so as to match the existing one with rubber gasket complete all as specified and as directed.
5
-
-
All as per Item No. 28.00 above but for Geyser of 25/35 litres capacity.
5
-
-
Supply and fixing in repair glass wool suitable for geyser of any capacity complete all as specified and as directed.
5
-
-
Dismantling of existing unserviceable heating element from geyser and Supply and fixing in repair new heating element of 1.5 kw 230 volt, testing for its functionality and refixing all electrical and water connections complete all as specified and directed.
30
-
-
All as per item No 31.00 above but of 2.0 kw 230 volt element.
35
-
-
Dismantling of existing old unserviceable thermostat of Geyser of any capacity and Supply and fixing in repair new thermostat with specifications to match with the existing one, including refixing all connections, testing for functionality etc. complete all as specified and as directed.
40
-
-
Dismantling of existing unserviceable plug top and Supply anf fixing in repair 15 Amp plug top with all connections and acessories complete all as specified and as directed.
30
-
-
Supply and fixing in repair PVC Connection pipe 15 mm dia 60 cm long heavy duty with two Nos brass chromium plated union complete all as specified and directed.
40
-
-
Material and labour for painting of Refrigerator/Water cooler with two coats of DUCO paint (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed.
5
-
-
Taking down unserviceable stop valve and supply and fixing new stop valve CP of 15 mm bore complete all as directed.
5
-
-
Supply and Charging R-134 gas for Refrigerator all as directed.
7
-
-
Taking down indicator lamp of Geyser of any capacity and supply and fixing new indicator lamp of red, green colour complete all as directed.
15
-
-
Taking down old rusted clamps, nuts, bolts, washers etc in complete set and supply and fixing new clamp, nut, bolt, washer in complete set for hanging gyser all as directed.
10
-
-
Taking down carefully unserviceable indoor electronic type PCB from Split type AC of capacity 1.5 to 2.0 Ton repairing and refixing complete all as specified.
5
-
-
Supply only outdoor fins type aluminium/copper condensor for Split type AC of capacity 2.0 Ton complete all as specified.
3
-
-
Evaluation Notes How It Works ?