Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Sep 2024
Closing Date31 Oct 2024
Tender Amount₹ 1,32,00,000 
Notes
Download

Costs

Summary

Special Repair/replacement Of Old Two Pole/four Pole

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Note: item no (1 to 3) (i) Load Break Switch module consisting of following accessories : 11kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 21kA/3-sec, Making Capacity - 52kAp Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 No.for Incoming LBS Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future. Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live-condition, Right angle boots (push on type) Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243

-

-

-

... More
(ii) Breaker module consisting of following accessories : 11kV, 630A fixed-type Vaccum Circuit Breaker module for making and breaking of fault current alongwith disconnector+Earth Switch of full making capacity Short time current - 21KA/ 3 sec, Making Capacity - 52kAp Auxiliary contacts - 1NO + 1NC Stored Enegry mechanism with manual spring-charging, associated closing/tripping coils, integrated non-removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism Interlocked Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3X). Safety interlocked to prevent access to cable termination in live-condition. Right angle boots (push on type) Numerical based self-powered OC+EF Protection Relay, providing OverCurrent (min. setting 20%), Earth-Fault (min. setting: 10%) 03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc.Cl.5P10), installed away from bushings to prevent saturation of core. Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged (iii)Capacitive voltage indication fixed type VPIS 9-15 kV (iv)Necessay interclocking arrangement for safety and operations (v)One No. Operationg Handle for Manual Operation and one no. manometer (vi)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (vii)Above switchgear shall confirm to all relevant IEC/IS Standards. (viii) Vacuum interrupter should be of same make as RMU (ix)Cable bushing should be replacable at site. (x) Minimum 5 module should accommodate in one tank to avoid multiple coupling at site.

-

-

-

... More
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure etc complete all as specified and directed.

59

-

-

... More
Supply,Laying testing in replacement of cable XLPE insulated, screened, PVC bended,galvanized steel strip or wire armoured, electric power cables (heavy duty) with standed aluminium conductor, 11000 volts grade, of size 3 core 95 Sq mm Note: Old Ht cbles maney placess comes under the building/sewage pipe lines/roads so that the total credit ht cble not carted into credit schedule .

944

-

-

... More
Slupply and fix in replacement of cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete wioth jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 120 to 185 Sq mm

22

-

-

... More
Slupply and fix in replacement of cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete wioth jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 50 to 95 Sq mm

20

-

-

... More
Slupply and fix in replacement of cable jointing kit for 11 KV grade cable for out door termination, heat shrink type, joint complete wioth jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 50 to 95 Sq mm

7

-

-

... More
Slupply and fix in replacement of cable jointing kit for 11 KV grade cable for out door termination, heat shrink type, joint complete wioth jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 120 to 185 Sq mm

6

-

-

... More
Slupply and fix in replacement of cable jointing kit for 11 KV grade cable for straight throughj cold shrink type, joint complete wioth jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 50 to 95 Sq mm

6

-

-

... More
Slupply and fix in replacement of cable jointing kit for 11 KV grade cable for straight throughj cold shrink type, joint complete wioth jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 120 to 185 Sq mm

6

-

-

... More
Supply and laying in replacement of GI tubing 100 mm dia light grade laid in trenches/floor/fixing on pole / wall / in tarmac including necessary fittings etc.complete& all as specified and directed.

91

-

-

... More
Excavation in trenches, for foundation of poles, stays or for laying of cables, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out as in soft / loose soil complete all as specified & directed.

305

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil completer all as specified and directed.

211

-

-

... More
Removing excavated material(soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed

94

-

-

... More
M & L of Supplying and laying reinforced precast concrete cable cover, class HV, type 1 , flat, size 300mm x 180mm x 40 mm and flat across the axis of cable,complete all as specified & as directed by Engineer-in-Charge.

4152

-

-

... More
M&L for sand cushioning to underground cable in trenches with clean dry river sand for protection of cable complete all as specified and directed.( punned thickness will be measured).

61

-

-

... More
Material and labour in replacement of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : Earth result after installation completely should be less than 3 ohm.

22

-

-

... More
Supply and fix in repair mild steel galvanised earth strip of size 32 x 6 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal including taking down old strip all as directed by Engr-in-charge.

60

-

-

... More
Taking down old u/s two pole four pole structure and connected items complete removing at site and deposited at mes stores all as specified and directed by Engineer-in-Charge.

11

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.