Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 94,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660864_1Bid Award Id
ViewTender No
8808/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
22
-
-
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge.
38.4
-
-
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
3
-
-
Taking up or down 20-32mm dia CPVC/ GI/ PP-R tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed by Engineer-in-charge.
57
-
-
Taking down Bib tap, Pillar tap, Stop cock, Shower rose, Health faucet, mixer of any description, complete all as specified and as directed by Engineer-in-charge.
12
-
-
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
15
-
-
Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
356
-
-
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
13
-
-
M&L for Excavation in post holes (or similar holes) each n.exc 0.5cum in soft/loose soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing of surplus soil to a distance n.exc 50 meters and making good surface, complete all as per specified and as directed by Engineer-in-charge.
12
-
-
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
2.1
-
-
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
14
-
-
M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
6.6
-
-
M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
65
-
-
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
61
-
-
M&L for Providing precast cement concrete louvres and jallies, 40mm thick (measured solid), including all mouldings but excluding frame of Type B-0, 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4, complete all as specified and as directed by Engineer-in-charge.
3
-
-
M&L for Reinforced Cement Concrete, (Nominal Mix) 1:1½:3, type A-1 (20mm graded stone aggregate) in footing, foundation, plinth Beams, etc., complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
4
-
-
M&L for Reinforced Cement Concrete, (Nominal Mix) 1:1½:3, type A-1 (20mm graded stone aggregate) in Beams, cantilevers, lintels over 1.5m span, Chajjas including demolition of existing old damaged RCC structure, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
3
-
-
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
41
-
-
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of sides and soffits of floor or roof beams, lintels, Chajjas, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
25
-
-
S&F of TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
602
-
-
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
196
-
-
S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
3400
-
-
All as per Item No. 25 here-in-above, but for erection & febrication only, complete all as per specified and as directed by Engineer-in-charge.
700
-
-
S&F of mild steel flat iron or other steel section as in hold-fast, wall tie, wind ties for roof including drilling, securing bolts and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed by Engineer-in-charge.
34
-
-
S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
80
-
-
S&F of Pressed steel frames for double shutter doors of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, and filling in frame with Cement Concrete 1:2:4, type B-0 (12.5mm graded aggregate) including necessary Formwork as required at Site(s), complete all as specified and as directed by Engineer-in-charge.
52
-
-
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
24
-
-
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
24
-
-
S&F of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engineer-in-charge.
15
-
-
S&F of 30mm thick factory made second class hard wood Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and both faces are covered with decorative face veneer with lipping/frame to match; complete all as specified and as directed by Engineer-in-charge.
20
-
-
S&F of 30mm thick factory made second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters and provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b); complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F of 200 mm long Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F of 200 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F of 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
15
-
-
S&F of Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
29
-
-
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius built and set in cement mortar 1:6,complete all as per specified and as directed by Engineer-in-charge.
26
-
-
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
272
-
-
M&L for Rendering 10mm thick in cement morter 1:6 on other than fair faces of brick work or concrete surfaces/ other side of lathing, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
367
-
-
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 on fair faces Brick Walls/Concrete Surfaces/ one side of lathing, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge.
269
-
-
M&L for providing 38mm wide glass dividing strips, 3mm thick, inserted in position, conform to design, complete all as specified and as directed by Engineer-in-charge.
180
-
-
M&L for providing 75 mm thick Cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
316
-
-
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
72
-
-
M&L for providing 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
686
-
-
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
30
-
-
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in vertical surface (like skirting, dado, etc.), over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
49
-
-
M&L for providing Vitrified Ceramic light shade tiles 8 to 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
125
-
-
M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
70
-
-
M&L for Machine cut kota stone slab flooring 14-16mm thick over 20mm thick cement screed base 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge.
90
-
-
M&L for 14-16mm thick Granite work (of any type, table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as per specified and as directed by Engineer-in-charge.
4
-
-
M&L for providing Machine pressed precast concrete interlocking paver block any shape and size onfirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, with grey cement and pigment, complete all as per specified and as directed by Engineer-in-charge.
120
-
-
M&L for providing glossy finished PU coated Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, complete all as per specified and as directed by Engineer-in-charge.
30
-
-
S&F in-repair of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including supplying & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
185
-
-
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated/ semi-corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
580
-
-
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
50
-
-
S&F 100mm wide high intensity radium reflective tape/ sticker of red and yellow colour, placed alternately, complete all as specified and as directed by Engineer-in-charge.
1
-
-
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
275
-
-
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge.
230
-
-
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 2.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
130
-
-
M&L for preparation of new or previously un-treated wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
34
-
-
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
187
-
-
M&L for constuction of masonary (Brick work with sub class 'B' bricks in full brick wall in CM 1:6) two stagging walls with double stable of standard size of height upto 3.0m above GL as per drawing no RNG/ TD/ 37 sheet 1/1 for PVC Tank as per specification of SSR Part-I(2009), complete all as specified and as directed by Engineer-in-charge.
1
-
-
S&F of 20mm dia (Outer) CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 fittings fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
45
-
-
All as per Item No. 66 here-in-above, but for 25mm dia GI tubing, complete all as specified and as directed by Engineer-in-charge.
25
-
-
All as per Item No. 66 here-in-above, but for 32mm dia GI tubing, complete all as specified and as directed by Engineer-in-charge.
32
-
-
S&F of Rotational Moulded Polyethylene Water Storage Tank 1000 Litre capacity (Cylindrical Vertical with Closed Top), 3 layered, hoisted and fixed in position, all as specified in MES Schedule Part-I with and including providing 20 mm dia float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210gm), complete all as specified and as directed by Engineer-in-charge.
1
-
-
S&F of 25 mm bore (dia), gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778, complete all as specified and as directed by Engineer-in-charge.
1
-
-
S&F of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F of 15 mm dia fancy type chromium plated Pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
7
-
-
S&F of Vitreous China wash basin, white, with brackets, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F in-repair of sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and as directed by Engineer-in-charge.
5
-
-
S&F of 110mm dia PVC (SWR) pipes including necessary fittings of any type, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
15
-
-
S&F of fully self operated environment friendly stainless steel turbo roof ventilator of 600mm dia (Dia of bottom ring) with 0.5mm thick vanes and permanently lubricated & sealed bearing, complete all as specified and as directed by Engineer-in-charge. (ISI Approved make)
2
-
-
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets, tube light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
64
-
-
Taking down carefully old unserviceable main switch and DB's with and including MCB's and wooden board, etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
2
-
-
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl concealed (on wall only) PVC conduit (medium grade) with fittings of adequate dia and length with all accessories and fittings like bends, elbow, crosses, etc. with and including cutting chases and modular terminal boxes for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge.
45
-
-
All as per Item No. 82 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
5
-
-
All as per Item No. 82 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
10
-
-
All as per Item No. 82 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
10
-
-
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge.
10
-
-
All as per Item No. 86 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
2
-
-
All as per Item No. 86 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
2
-
-
All as per Item No. 86 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F Modular Switch, One Module, 1-Way, 10 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
60
-
-
S&F Modular Switch, One Module, 1-Way, 20 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
10
-
-
S&F Modular Socket, 2/3 Pin, combined, Two Module, 10 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
15
-
-
S&F Modular Socket, 2/3 Pin, combined, Two Module, 20 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
10
-
-
S&F of Modular stepped type electronic fan regulator, Two module, 240V, AC, complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F of modular cover plate (white) with frame, 2-module, complete all as specified and as directed by Engineer-in-charge.
3
-
-
S&F of modular cover plate (white) with frame, 3-module, complete all as specified and as directed by Engineer-in-charge.
20
-
-
S&F of modular cover plate (white) with frame, 4-module, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of modular cover plate (white) with frame, 6-module, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F of modular cover plate (white) with frame, 8-module, complete all as specified and as directed by Engineer-in-charge.
7
-
-
S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
12
-
-
S&F of Socket outlet 3 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of Switch socket combination 2 in 1, 3/5Pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of Switch socket combination 2 in 1, 5/6 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
33
-
-
S&F of Sheet Metal Enclosure MCB DB TPN, 4 way 415 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
1
-
-
S&F of Sheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
3
-
-
S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
1
-
-
S&F of MCB Triple Pole & Neutral (TPN), 'C' Curve, 40-100 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
1
-
-
S&F of MCB Single Pole & Neutral (SPN), 'C' Curve, 40 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
9
-
-
S&F of MCB Single Pole & Neutral (SPN), 'C' Curve, 63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
11
-
-
S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including PVC conduit (medium grade) ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed.
NOTE :- (a) Cost of PVC conduit (medium grade) with all Fittings/Accessories will deem to be included in the quoted UNIT RATE.
(b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC conduit with all Fittings/Accessories will be measured and paid as ONE UNIT.
(c) Sub-main Wiring will be measured as length of PVC conduit only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
40
-
-
S&F of exhaust fan, metal body, heavy duty, AC single Phase, 230V, 50 Hz, RPM 1200, Copper winding of size 300m sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F of surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
26
-
-
S&F of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
12
-
-
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with and including necessary mounting arrangements of bracket made out of 1.2m long 32mm dia light grade GI pipe bend to required shape with necessary fixing clamps (MS flat iron clamp 25x4mm) nut-bolts and applying two coats of aluminium paints on the MS surfaces, complete all as specified and as directed by Engineer-in-charge.
3
-
-
All as per Item No. 117 here-in-above, but in-repair, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 Sqmm section, complete all as specified and as directed by engineer-in-charge.
126
-
-
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) Item rates includes the cost of 7.5 mtr earth lead GI earth wire.
2
-
-
All as per Item No. 119 here-in-above, but including taking down existing old damaged earthing, complete all as specified and as directed by Engineer-in-charge.
2
-
-