Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688562_1Tender No
8932Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as in Item No - 01, but for 3.5/4 core 70 to 120 Sqmm
15
-
-
... More
All as in Item No - 01, but for 3.5/4 core 25 to 50 Sqmm
10
-
-
... More
All as in Item No - 01, but for 3.5/4 core 6 to 16 sqmm
4
-
-
... More
Supply and fixing in replacement of LT cable Straight through jointing kit ,1100 volt grade (earthed) 3.5/4 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location.Complete all as specified and as directed.
1
-
-
... More
All as in Item No - 07, but for 3.5 core 240 to 300 Sqmm
1
-
-
... More
All as in Item No - 07, but for 3.5/4 core 150 to 185 Sqmm
1
-
-
... More
All as in Item No - 07, but for 3.5/4 core 70 to 120 Sqmm
1
-
-
... More
All as in Item No - 07, but for 3.5/4 core 25 to 50 Sqmm
1
-
-
... More
All as in Item No - 07, but for 3.5/4 core 6 to 16 sqmm
1
-
-
... More
Supply and fixing of MCCB 400 amps, 4 pole,415 Volts microprocessor based type with breaking capacity 36 KA, and 100 % Icu including spreader terminals and Suitable for Isolation Adjustable Over Load setting ,Adjustable Short Circuit setting, ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-charge.
5
-
-
... More
All as in Item No-13, But for 250 Amps.
8
-
-
... More
All as in Item No-13, But for 200 Amps.
6
-
-
... More
All as in Item No-13, But for 160 Amps.
10
-
-
... More
Supply and fixing of MCCB 100 amps, 4 pole,415 Volts Adjustable type with breaking capacity 36 KA, and 100 % Icu including spreader terminals and connected acessories complete as specified and directed.
10
-
-
... More
All as in Item No-17, But for 63 Amps.
9
-
-
... More
Supply, fixing and connecting in replacement of Manual On Load change over switch with sheet steel enclosure rating 63 Amps 4 pole, 440 volts grade in surface of wall on wooden board with making all coonection, gland etc all as site and directed.
2
-
-
... More
All as in Item No- 19, But for 100 Amps.
3
-
-
... More
All as in Item No- 19, But for 200 Amps.
2
-
-
... More
All as in Item No- 19, But for 400 Amps.
3
-
-
... More
Supply, fixing and connecting in replacement of Manual On Load change over switch with open Execution rating 100 Amps 4 pole, 440 volts grade fixing in panel with making all coonection, gland etc all as site and directed.
2
-
-
... More
All as in Item No- 23, But for 200 Amps.
4
-
-
... More
All as in Item No- 23, But for 400 Amps.
5
-
-
... More
Supply, install, testing & commissioning of LT busbar chamber of size (0.60x0.60x0.60)m, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick of length 0.6 m from PCC, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) including rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS:
MCCB 200 amps, 4 pole,415 Volt Adjustable type with breaking capacity 36 KA, and 100 % Icu fitted with bus-bars shall be made up of 04 Nos Aluminium 400 A rated not less than 40 mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves - 01 No. PROVISION FOR CABLE ENTRY :
The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.
INSTRUMENTATION SYSTEM :
(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.
(b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos.
NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions including its all accessories are to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
5
-
-
... More
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 300 Sqmm x 3.5 core. Complete all as specified and as directed.
50
-
-
... More
All as in Item No-27 but for 240 Sqmm x 3.5 core
50
-
-
... More
All as in Item No-27 but for 150 Sqmm x 3.5 core
250
-
-
... More
All as in Item No-27 but for 120 Sqmm x 3.5 core
100
-
-
... More
All as in Item No-27 but for 95 Sqmm x 3.5 core
140
-
-
... More
All as in Item No-27 but for 50 Sqmm x 3.5 core
100
-
-
... More
All as in Item No-27 but for 25 Sqmm x 4 core
100
-
-
... More
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
45
-
-
... More
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
26
-
-
... More
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
19
-
-
... More
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230 mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and as directed. Note : punned thickness will only be measured for payment purpose.
16
-
-
... More
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed by Engineer-in-charge.
1.7
-
-
... More
Labour for horizontal boring of Road/path for cable passing through complete all as specified
18
-
-
... More
Supply/ laid/ fixing in replacement of galvanised steel water tube, light grade bore of dia 80 mm with all fittings all as site and directed.
24
-
-
... More
Supply/ laid/ fixing in replacement of galvanised steel water tube, light grade bore of dia 50 mm with all fittings all as site and directed.
12
-
-
... More
M&L for jointing/ cutting/ welding/ replacing hinges etc all as site required to LT panel made out MS sheet and angle for making smoth opening and closing complete with re-painting as same macthing with exsiting surrface all as directed.
8
-
-
... More
Decarbonising/ cleaning of Existing LT panel cubical type of various size consists of bus bar and circuit chamber, metering chambers CTs and relays chambers, checking the bus bar joints, bus bar and circuit spouts, cleaning and applying Busbar Insulation Tape to the bus bars , checking the current transformer, applying Monoplast compound at the bus bar joints after tightening of joints ,replaced new suiable size of lugs /suitable copper control cable and reassembling , if any rusted sheet replaced with new sheet as per existing size complete all as directed by Engineer-in-Charge. Note:- Cost of lubricant/ cleaning agents (CRC & rust remover) / hardware like springs/ bolts/ nuts/ washers,lugs/ suitable copper cables cost of labour, T&P required for replacement shall be etc. shall be deemed to be included in the rate quoted.
23
-
-
... More
Material and labour for painting to LT panel of any size by scrapping and removing oil paint and applying 01 coats of synthetic enamel paint of approved colour by taking due complete all as specified and directed by Engineer-in-charge .
15
-
-
... More
Supply and fix 3 phase LED digital Ammeter square shape,Accuracy CL-0.5, with CT site selectable 1/5A, inbuilt selecteor switch suitable for for panel including taking down Ammeter meter , all as specified and directed by Engineer-in-charge.
8
-
-
... More
Supply and fix 3 phase LED digital Voltmeter for LT measurement square shape, Accuracy Type-0.5, inbuilt selecteor switch suitable for for panel including taking down Volt meter , all as specified and directed by Engineer-in-charge.
8
-
-
... More
S & F LED indicating Lamps for R, Y, B phases complete including taking down ols U/S lamps all as specified and directed.
8
-
-
... More
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.5 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.
Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate.
25
-
-
... More
Supply and fixing in replacement of Test point terminal block made of gun metal or phosphorus bronze in size 75x75x25 mm drilled and screwed including 03 nos ,8 mm dai 25 mm long hex head screw complete all as specified and directed.
6
-
-
... More
Supply and lying in repair of Chequred Electrical rubber mat of size 1m x 2m , 6 mm thick complete all as specified and directed by Engr-in-charge
18
-
-
... More
Supply & Fix in repair capacitor duty contactors ranging from of 3 KVAr, 440V site selectable with built-in Auxilliary contact complete all as specified and directed.
3
-
-
... More
All as in Item No- 51 above but for capacity 5 KVAR.
6
-
-
... More
All as in Item No- 51 above but for capacity 10 KVAR.
5
-
-
... More
All as in Item No- 51 above but for capacity 20 KVAR.
3
-
-
... More
Supply & Fix in repair capacitor gas filled heavy duty cylindrical of 1-4 KVAR, 440V complete all as specified and directed.
4
-
-
... More
All as in Item No- 55 above but for capacity 5-15 KVAR.
4
-
-
... More
All as in Item No- 55 above but for capacity 20-30 KVAR.
2
-
-
... More
S & F in repair APFC controller site selectable with 8 steps with single CT input , input voltage 440 V with auto programming feature complete all as specified and directed.
2
-
-
... More
All as in Item No- 58 above but for 12 steps. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor's firm name while carrying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%