BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 Nov 2024
Closing Date25 Nov 2024
Tender Amount₹ 38,75,000
Costs
EMD
₹ 77,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682559_1Tender No
8014/B/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down cement plaster/cement mud plaster on brick walls etc, incl racking out joints, hacking for key, scrubbing down with water etc.
500
-
-
Material and labour for 15 mm thick rendering in CM 1:6 on brick/ concrete surfaces and finishing the surfaces even and smooth without using extra cement etc omplete all as specified and directed.
300
-
-
Material and labour for 15 mm thick rendering in CM 1:4 on brick/concrete external surfaces and finishing the surfaces even and smooth without using extra cement etc complete all as specified and directed.
200
-
-
Material and labour for preparation of old distempered surface of wall including cornices etc. by washing, rubbing down,scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and stopping of distempered surfaces and applying one coat of acrylic distemper of approved shade on surface of wall complete all as specified and directed.
400
-
-
Material and labour for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coats of cement based paint over a coat of primer etc complete all as specified and directed.
200
-
-
Material and labour for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of white cement putty 3 mm thick, sanding the surfaces till smooth finish is obtained and finally applying two coats of acrylic distemper etc complete all as specified and directed.
300
-
-
Material and labour for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of white wash on old surface of wall complete all as specified and directed.
200
-
-
Material and labour for preparing of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
80
-
-
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer etc complete all as specified and directed.
200
-
-
Material and labour for preparation of new steel surfaces exc 10 cm width/girth and applying two coats of synthethic enamel paint over a coat of primer etc complete all as specified and directed.
100
-
-
Material and labour for preparation of old painted steel surfaces exc 10 cm width/girth and applying one coats of synthethic enamel paint complete all as specified and directed.
200
-
-
Dismantling wrought iron or mild steel work of any description and in any position not otherwise provided for complete all as specified and as directed.
10
-
-
Supply and fix plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections for use in sliding Iron doors usingFe 410 -W (GdeE- 250) qualityA complete all as specified and directed.
100
-
-
Supply and fix mild steel Framed work such as grills, gratings, angle iron, mild steel sheets, mild steel round bar, MS flat iron etc.. for chowkhats or doors shutters or windows etc with ends of bars shouldered and/or riveted, wlded or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
150
-
-
Supply and fix framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
1000
-
-
Material and labour for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St.-240 complete all as specified and as directed.
900
-
-
Supply and fix suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 32 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 3mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid incl dismantling complete all as specified and as directed.
60
-
-
Dismantling of AC sheet corrugated/semi corrugted sheets in wall cladding or in roof covering complete all as specified and directed.
1570
-
-
Demolition of plain cement in any description and in any position not otherwise specifically provided for for complete all as specified and as directed.
50
-
-
Supply and fix Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
1570
-
-
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
40
-
-
Material and labour for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or more complete all as specified and as directed.
50
-
-
Material and labour for 100mm thick PCC 1:2:4 type B2, (using40 mm graded stone aggregate) as in flooring finished even and fair without using extra complete all as specified and as directed.
40
-
-
Material and labour for cement concrete 1:2:4 type B-2, (using 40 mm graded stone aggregate) as in surface channels and drain with and including neceaary formwork.complete all as specified and as directed.
4
-
-
Dismantling of stone slabs and tiles of andy description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar .
8
-
-
Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness,M-40
Grade as approved and laid over on sand cushion and joints filling with sand complete all as specified and directed.(Sand cushion measured and paid seperately)
80
-
-
Material and labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
2
-
-
Material and labour for forming 12mm thick expansion joints and 100mm thickness of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' complete all as specified and directed.
3
-
-
Material and labour for forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound, Grade 'A' complete all as specified and directed.
10
-
-
Supply and fix polythene film, black, 150micron laid in floors complete all as specified and directed.
40
-
-
Material and labour for forming Construction joint 30mm deep x 10mm wide filled with sealing compound , Grade 'A' complete all as specified and directed.
2
-
-
Material and labour for 75mm thick PCC 1:3:6 (20mm graded stone aggregate) type C-1, as in plinth protection, providing 10mm groves at every 3 mtr interval and filled with bituminious filler finish even and smooth without using extra cement complete all as specified and directed.
130
-
-
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
30
-
-
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over 15mm thick rendering in CM 1:4 complete all as specified and directed.
10
-
-
Taking down chowkats with shutters including builders hardware(without taking off shutters from the frame) area n.exc. 1.5 Sqm each complete all as specified and as directed.
24
-
-
Taking down chowkats or frames area exceeding 1.5 Sqm but not exceeding 4 Sqm each including shutter with builders hardware (without taking off shutters from the frame) complete all as specified and as directed.
4
-
-
Material and labour for 1.25mm thick factory made pressed steel frames of size 105x60mm with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete including PCC 1:3:6 type C-0 as in back filling of window/door frame all as specified and directed.
30
-
-
Supply and fix flush shutters 35mm thick , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed
15
-
-
Supply and fix aluminium anodised barrel tower bolts of extruded sections 200 mm size complete all as specified and directed.
12
-
-
Supply and fix 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and
6
-
-
Supply and fix 150 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
12
-
-
Material and labour for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed.
45
-
-
Supply and fix steel windows with side hung shutters glazed shutter including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or ground bar of approved design welded to steel window frame dovetailed or welded omplete all as specified and directed.
30
-
-
Supply and fix in repair sheet glass 4.8 mm thick frosted quality and glazing with oil putty in squares not exc. 0.50sqm in each pane complete all as specified and directed.
20
-
-
Taking down carefully aluminium / copper point wiring for light / fan / socket / bell or power point including taking down concealed conduit if any, all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
186
-
-
Material and labour for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC rigid conduit on walls/ceiling ( concealed), with MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulators etc. including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one 5 Amp switch one way complete all as specified and as directed.
136
-
-
All as per item serial No49 here-in-before but One 3 pin socket outlet 6 amps on the same board with other switches.
15
-
-
All as per item serial No 49 here-in-before but One socket outlet 3 pin 6 Amp on independent board.
25
-
-
All as per item serial No 49 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable for 6 pin 15 Amp socket outlet on independent board and earth continuity wire with 2.5 sqmm cable.
10
-
-
Supply and fix in repair switch flush type 5 Amp 240 Volts single one way complete all as specified and as directed.
151
-
-
Supply and fix in repair Socket outlet 2 in 1, 3 Pin 5 Amp flush type 240 volts complete all as specified and as directed.
15
-
-
Supply and fix in repair switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
25
-
-
Supply and fix in repair switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
10
-
-
Supply and fix in repair stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
35
-
-
Supply and fix ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed.
136
-
-
Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative batten with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
115
-
-
Supply and fix in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
6
-
-
Supply and fix in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
4
-
-
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
35
-
-
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep, 1400 rpm with blades, and frame and louvers including making hole in existing wall suitable for fixing of exhaust fan and making good.
3
-
-
Supply and fix in repair/replacement LED 60 W building secruity light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and directed.
4
-
-
Material and labour for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
4
-
-
Supply and fix factory made, sheet steel distribution boards, double door, protection class IP-43, SPN 4 Ways suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified and as directed.
2
-
-
Supply and fix factory made, sheet steel distribution boards, double door, protection class IP-43, SPN 8 Ways suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified and as directed.
3
-
-
Supply and fix MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs complete all as specified and as directed.
22
-
-
Supply and fix MCB SP 40 Amps, 240 V,50 HZ,B series breaking capacity 10KA complete all as specified and as directed.
10
-
-
Supply and fix in repair/replacement MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule)
5
-
-
Supply and fix in repair/replacement for factory made, sheet steel distribution boards, TPN, 4 Way, IP-43 with min 100 Amp rating copper bus bar double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-0 using 12.5 mm graded stone aggregate all as directed.
2
-
-
Supply and fix in repair/replacement MCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified.
2
-
-
Material and labour for sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.
245
-
-
Material and labour for wiring with 2 runs of 2.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.
282
-
-
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down complete all as specified and directed.
2
-
-
Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4.0 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc including taking down old , complete all as specified and as directed.
70
-
-
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
10.25
-
-
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
3.1
-
-
Material and labour for bricks sub class ‘B’ brick old size for cable protection laid in flat in trenches over the cable perpendicular to the direction of cable complete all as specified
0.52
-
-
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
7.11
-
-
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
6.05
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%