Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_638755_1Bid Award Id
ViewTender No
8758/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
All as per Item No. 03 here-in-above, but for 25mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
298
-
-
All as per Item No. 03 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
308
-
-
All as per Item No. 03 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
348
-
-
All as per Item No. 03 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
428
-
-
All as per Item No. 03 here-in-above, but for 63mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
410
-
-
All as per Item No. 03 here-in-above, but for 90mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
390
-
-
All as per Item No. 03 here-in-above, but for 110mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
220
-
-
Labour only for laying/fixing of serviceable GI/PP-R pipe of any type of 20mm dia for hot & cold water supply with all fittings laid in trenches/ fixed to wall including taking down the existing CI/GI/PP-R pipe, cleaning the same for re-use and testing, complete all as specified and as directed by Engineer-in-charge.
40
-
-
All as per Item No. 11 here-in-above, but for 25mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
50
-
-
All as per Item No. 11 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
60
-
-
All as per Item No. 11 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
80
-
-
All as per Item No. 11 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
90
-
-
All as per Item No. 11 here-in-above, but for 80mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
50
-
-
All as per Item No. 11 here-in-above, but for 100mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
40
-
-
S&F in-repair of 25mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
26
-
-
S&F in-repair of 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
23
-
-
S&F in-repair of 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F in-repair of 63mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
6
-
-
S&F in-repair of PP-R male threaded socket with and including necessary jointing material for 16mm dia (outer dia) pipe line, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F in-repair of PP-R male threaded socket with and including necessary jointing material for 25mm dia (outer dia) pipe line, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F in-repair of PP-R male threaded socket with and including necessary jointing material for 32mm dia (outer dia) pipe line, complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F in-repair of brass tank connector of 25mm dia, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F in-repair of brass tank connector of 32mm dia, complete all as specified and as directed by Engineer-in-charge.
12
-
-
S&F in repair fully automatic star delta starter for upto 37.3Kw motor in sheet metal encloser type MN with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and diredted by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
3
-
-
S&F in repair fully automatic star delta starter for upto 22.5Kw motor in sheet metal encloser type MN with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and diredted by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
3
-
-
S&F of 25 mm bore (dia), gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 and including taking out old unserviceable gate valves complete all as specified and as directed by Engineer-in-charge.
10
-
-
All as per Item No. 29 here-in-above, but for 40mm dia gun metal gate valves, complete all as specified and as directed by Engineer-in-charge.
4
-
-
All as per Item No. 29 here-in-above, but for 50mm dia gun metal gate valves, complete all as specified and as directed by Engineer-in-charge.
4
-
-
M&L for repairing of sluice valve of 100mm dia by replaceng GI Spindle, CI gate mechanical sealing, complete all as specified and as directed by Engineer-in-charge.
4
-
-
M&L for repairing of sluice valve of 150mm dia by replaceng GI Spindle, CI gate mechanical sealing, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F in-repair of hand wheel of sluice valve of 80-100mm dia, complete all as specified and as directed by Engineer-in-charge.
5
-
-
Supply & Fixing, jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 80 mm bore (Internal Dia) confirming to IS 14846-2000, flanged ends drilled having brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves, complete all as specified and as directed by Engineer-in-charge.
4
-
-
All as per Item No. 35 here-in-above, but for 100mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
6
-
-
All as per Item No. 35 here-in-above, but for 150mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
4
-
-
Supply & Fixing, jointing and testing of cast iron Non Return Valve (NRV) ISI mark (PN-1.6) of size 80 mm bore, without bypass arrangement, swing type, conforming to IS-5312, complete with nuts, bolts, washers and gaskets including taking out old unserviceable NRV, complete all as directed by Engineer-in-charge.
2
-
-
All as per Item No. 38 here-in-above, but for 100mm dia cast iron Non Return Valve (NRV) ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
3
-
-
Supply and Fix CI butterfly valve 80 mm dia without lugs, lever operated CI disc, EPDM rubber lining including taking out old unserviceable one, complete all as directed by Engineer-in-charge.
2
-
-
Supply and Fix CI butterfly valve 100 mm dia without lugs, lever operated CI disc, EPDM rubber lining including taking out old unserviceable one, complete all as directed by Engineer-in-charge.
2
-
-
M&L for Making connection of PP-R distribution branch with PP-R main of 16-40mm dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed by Engineer-in-charge.
6
-
-
M&L for Making connection of PP-R distribution branch with PP-R main of 50-75mm dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed by Engineer-in-charge.
6
-
-
M&L for Cutting and Screwing existing 80-100mm dia steel tubing for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F in-repair of CI Venturi of 100mm dia having arrangement for dosing of bleaching powder/ Altoch GP solution, complete all as specified and as directed by Engineer-in-charge.
1
-
-
M&L for boring holes horizontally under road without damaging the road surface for passing 40-150mm dia pipeline, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately.
36
-
-
M&L for construction of Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 150mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally upto full depth and externally upto 150mm below GL, providing 3mm thick MS black Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as directed by Engineer-in-charge.
2
-
-
All as per Item No. 47 here-in-above, but for 600mm X 600mm X 600mm (Internal dimension) valve pit, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F in-repair of rubber packing sheet of 6mm thick, complete all as specified and as directed by Engineer-in-charge.
20
-
-
Taking out old unserviceable/corroded MS cover of valve pit of any size and replace same with new valve pit cover made of 3mm thick MS black sheet welded to 40 x 6mm equal angle at sides and diagonals including 40 x 6mm equal angle for making resting base frame, both resting frame and cover should be hinged at two points along one side, including applying two coats of Synthetic enamel paint over a coat of red oxide primer on all around of MS Sheet and angle iron with providing necessary locking arrangement and handle, all as directed by Engr-in-charge.
150
-
-
M&L for disconnecting of defective Air compressor from the Pump house including motor of 3 phase and Compressor alongwith PVC pipe including disconnection electric connection as required and dismantling spare parts of Air Compressor of any size and motor overhauling and rewinding, greasing, testing and separating the unserviceable parts cleaning the serviceable parts, re-metalling machinery polishing and re-assembling including replacement of old parts and necessary painting apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer complete all as specified. Note:- The following spare items are measured and paid separately.
1
-
-
Supply only piston for pump set of any type
1
-
-
Supply only piston oil ring for pump set of any type
1
-
-
Supply only liner for pump set of any type
1
-
-
Supply only bearing for pump set of any type
1
-
-
Supply only gear oil for pump set of any type
1
-
-
Supply only compressor air meter for pump set of any type
1
-
-
Supply only nozzle (air) for pump set of any type
1
-
-
Supply only 15mm dia Gun metal gate valve for pump set of any type
1
-
-
Supply only PVC nylon heavy duty pipe for pump set of any type
12
-
-
Supply only fan blade for pump set of any type
1
-
-
M&L for lifting of submersible mortor pump set (upto 20 Hp) from existing borewell of depth upto 30 Mt with the help of chain pully carefully including MS/GI pipe and submersible cable and lowering the submersible pumps set into the existing borewell upto a depth of 30 Mt including submersible cable and GI tubing/ MS tubing including repair/ overhauling of submersible pump by replacing the bush impeller, thrust bearing, nuts and bolts, washers, bowl, neck ring, SS Shaft key and winding the same with existing gauge etc and repair to pump set by re-mettaling, grinding, polishing on lathe machine, greasing and reassembling the pump set with complete testing including painting with 2 coat of enamel paint over a coats of redoxide primer. Note: Cost of small parts such as,nuts,bolts, are deemed to be included in quoted rate.
1
-
-
Dismantling of electrical connection, Taking down 5 to 10HP capacity induction motor by decoupling from pumping set and unscrewing of foundation nut/bolts (Transporting to worhshop and back to site after repair) rewinding of motor with suitable size of super enamelled copper wire including necessary insulating material, insulating varnish etc replacement of U/S parts (measured separately) re-assempling the motor and fixed in original position, reconnection to electrical mains and testing complete all as specified and directed.
3
-
-
Dismantling of electrical connection, Taking down 40HP capacity induction motor by decoupling from pumping set and unscrewing of foundation nut/bolts (Transporting to worhshop and back to site after repair) rewinding of motor with suitable size of super enamelled copper wire including necessary insulating material, insulating varnish etc replacement of U/S parts (measured separately) re-assempling the motor and fixed in original position, reconnection to electrical mains and testing complete all as specified and directed.
2
-
-
S&F in-repair of motor ball bearing for motor up to 50 HP matching to the existing one complete all as specified and directed.
4
-
-
S&F in-repair of pump ball bearing for pump up to 50 HP matching to the existing one complete all as specified and directed.
4
-
-
Supply and lowering of 10 Sq mm size submersible PVC copper conductor cable 3 core flat of 1100 Volt grade heavy duty compete all as specified and as directed by engr-in-charge MAKE- KEI/ Havells/ Polycab/ Finolex/ RR Kabel
200
-
-
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed.
2
-
-
S&F in-repair of MCCB 4 Pole, 415 Volts, 160 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 36 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
1
-
-
All as per Item No. 37 here-in-above, but for 100 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
1
-
-
M & L for Writing letters not exceeding 30 cm height on pumps body/ water pipe line etc complete all as specified and as directed.
8
-
-
M & L for Writing Arrow marking upto 40 cm long of suitable width on pumps body/ water pipe line/ surfaces of tanks etc complete all as specified and as directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements