BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date20 Apr 2020
Closing Date5 May 2020
Tender Amount₹ 9,54,586 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 1.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.

100

-

-

... More
Supply and fix socket outlet 6 pin,16 Amps ISI marked complete all as directed

40

-

-

... More
Supply and fix Modular switch outlet 6 pin,16 Amps ISI marked complete all as directed

200

-

-

... More
S&F in replacement of plug top 3 pin 16 amps ISI marked complete all as directed

20

-

-

... More
S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series all as specified and directed.

82

-

-

... More
M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.

40

-

-

... More
S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.

6

-

-

... More
S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.

8

-

-

... More
S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed.

12

-

-

... More
S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.

2

-

-

... More
S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler all as specified and directed.

10

-

-

... More
S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity all as specified and directed.

4

-

-

... More
S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC all as specified and directed.

8

-

-

... More
S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.

40

-

-

... More
Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.

2

-

-

... More
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.

21

-

-

... More
M&L for servicing only in situ of Split type air conditioner 1.5/2.0 Ton capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of GE.

30

-

-

... More
S&F in replacement indoor wall mounting unit of split type air conditioners electrically driven single phase of capacity 1.5/2.0 TR (make as required on site) including connection of pipe lines and charging refrigrant, testing complete all as specified and directed.

6

-

-

... More
M&L for dismantilling Split type/Window Type air conditioner 1.5/2.0 ton capacity after removing indoor outdoor copper tube connection, electric wire connection and transporting to authorised workshop for reapir, including cleaning of Cooling coil, condenser coil, fan motor, filling of refrigerant R-22 etc. and re-installing the same after complete repair and testing complete all as specified and directed . Note:- R-22 Gas will be measured and paid separately as supply only under relevant item.

12

-

-

... More
S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.

4

-

-

... More
S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.

20

-

-

... More
S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.

20

-

-

... More
S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.

20

-

-

... More
S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.

2

-

-

... More
S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.

6

-

-

... More
S&F in replacement of capacitor of cap 3.15 MFD complete all as specified and directed.

40

-

-

... More
S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton capacity complete all as specified and directed.

8

-

-

... More
S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.

12

-

-

... More
S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC all per directed.

30

-

-

... More
S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC all per directed.

30

-

-

... More
S&F in replacement of insulation cover of size 5/8" for insulating copper tube of split type AC all per directed.

40

-

-

... More
S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC all per directed.

20

-

-

... More
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.

100

-

-

... More
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-22/R-32 as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed.

16

-

-

... More
M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as directed.

4

-

-

... More
S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.

4

-

-

... More
S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed.

8

-

-

... More
S & F in replcement of MCB SPN 240 Volts, 6-32 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed

60

-

-

... More
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA all as specified and directed.

9

-

-

... More
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA all as specified and directed.

11

-

-

... More
Supply only refrigerant R-22 gas in air conditioner of any type make capacity complete all as speciifed and directed.

30

-

-

... More
S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.

20

-

-

... More
S&F in replacemet of heating element of capacity 3000W (Round or Triangular Head as required at site) suitable for solar water heater including rubber washer (ISI marked) etc complete all as directed

8

-

-

... More
S&F in replacemet of Solar water heating Flat plate collector of size & Aperture Area respectively 2025 mm L X 1025 mm W X 96 mm & 2 m2 complete all as specified and directed.

1

-

-

... More
Taking down and Refixing at site ceiling fans 1200/1400 mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of ball bearing etc and re-assembling the same including necessary transportation etc complete including taking down all as specified and directed.

120

-

-

... More
S&F in replacement of of rubber real insulator of suitable size complete all as specified and directed.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.