Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,32,300Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677923_1Tender No
84077/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 160 KVA of Make : __________, Engine Model No. : ____________, Alternator No. : _____________, Type : __________ Cooled & Year of Manufacturing : ______ and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
1
-
-
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 160 KVA of Make : __________, Engine Model No. : ____________, Alternator No. : _____________, Type : __________ Cooled & Year of Manufacturing : ______ and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
1
-
-
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 180 KVA of Make : __________, Engine Model No. : ____________, Alternator No. : _____________, Type : __________ Cooled & Year of Manufacturing : ______ and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
1
-
-
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 200 KVA of Make : __________, Engine Model No. : ____________, Alternator No. : _____________, Type : __________ Cooled & Year of Manufacturing : ______ and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
1
-
-
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 250 KVA of Make : __________, Engine Model No. : ____________, Alternator No. : _____________, Type : __________ Cooled & Year of Manufacturing : ______ and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
1
-
-
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 320 KVA of Make : __________, Engine Model No. : ____________, Alternator No. : _____________, Type : __________ Cooled & Year of Manufacturing : ______ and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
1
-
-
TECHNICAL SPECIFICATIONS : FOR ITEM No. 1 TO 9
(a) Type of Emission Device (Working Principle of PM Reduction Active Element) : Electrostatic Precipitation (ESP), Catalytic Conversion or Wet Scrubber
(b) Emission Limits as per CPCB-II Norms : PM 2.5≤0.2 G/KW-Hr, Smoke Limit (Light Absorption Co-efficient ≤0.7m-1
(c) Particulate Matter Capturing Efficiency : Greater than 70%
(d) Back Pressure on Engine : There should be no Back Pressure from RECD to Engine Exhaust System
(e) Material of Construction : SS202 for Inlet Chamber, Outer Body coated MS
(f) Emission Monitoring from Stack shall be Tested from any NABL approved Lab
(g) RECD's Power Requirement : Less than 1% of Capacity used for Operation
(h) Cleaning Mechanism : As per OEM
(j) Noise Emission : No Increase in Noise Level after Installation of Retrofit Device.
-
-
-
NOTES : FOR ITEM No. 1 TO 9
(a) Output Result of the RECD should be as per CPCB-II Norms as applicable and the OEM/ Manufacture should have Valid type CPCB Approval Certificate.
(b) The Quoted Unit Rate is inclusive of T&P Items such as Crane/ Hydra, etc. as required at Site of Work.
(c) The Scope of Work includes Emission Control System with PRV, Inlet and Outlet Pipe and Electric Panel and all Accessories as required at Site of Work.
(d) The Device should not have any Bye-Pass Arrangement.
(e) DG Set shall be Tested on All Load Pattern as Available at Site during Post RECD Installation.
(f) WARRANTY : The OEM shall provide Warranty of all respect for One Year Post Completion of Work/ Installation.
(g) Contractor shall Furnish Manufacture's Written Instructions and Requirement about the Use and Maintenance of RECD System, its Operation and Maintenance Schedule.
-
-
-
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable and 1-Run of 4.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn in and including Surface/ Recess PVC Casing Capping/ PVC Conduit (ISI Marked) of suitable Size (approx. 25/32mm Width/ Dia) alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed.
NOTE :-
(a) Cost of 3-Runs of Cable & 1-Run of PVC Casing Capping/ PVC Conduit will deem to be include in the Quoted Unit Rate and the same will be Measured as ONE UNIT.
(b) Sub-main Wiring will be measured PVC Casing Capping/ PVC Conduit only. Wires required for Looping, etc. will deem to be include in the Quoted Unit Rate.
35
-
-
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable and 1-Run of 6.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn in and including Surface/ Recess PVC Casing Capping/ PVC Conduit (ISI Marked) of suitable Size (approx. 25/32mm Width/ Dia) alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed.
NOTE :-
(a) Cost of 3-Runs of Cable & 1-Run of PVC Casing Capping/ PVC Conduit will deem to be include in the Quoted Unit Rate and the same will be Measured as ONE UNIT.
(b) Sub-main Wiring will be measured PVC Casing Capping/ PVC Conduit only. Wires required for Looping, etc. will deem to be include in the Quoted Unit Rate.
35
-
-
Excavating in Trenches, not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth; for Foundation, etc. or for Shafts, Wells, Cesspits, Manholes, Pier Holes, etc. not exc. 10 Sq m on Plan and not exc. 1.50 Metre in Depth and getting out in Soft/ Loose Soil, complete all as specified and as directed.
18
-
-
Removing Excavated Materials not exc. 50 Metre and Depositing where directed at a Level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
18
-
-
M&L Cement Concrete 1:3:6 (40mm graded stone aggregates) in Foundation, Filling and Mass Concrete, etc. including Use & Waste of Formwork as required/ ordered, complete all as specified and as directed.
NOTE : Cost of Formwork will deem to be include in Quoted Unit Rate.
42
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%