Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date31 Aug 2024
Closing Date21 Sep 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2 mm dia galvanised mild steel wire complete all as specified and as directed.

20

-

-

... More
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for LT, 200 mm X 150 mm complete all as specified and as directed.

2

-

-

... More
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type, weasel conductor in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.

0.25

-

-

... More
M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) seamless type, including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of bituminious paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed. Note- Earthwork shall be measured and paid seperately. Volume occupied by steel pole shall be deducted to derive the quantity of PCC.

6

-

-

... More
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, rated peak withstand current 63 kA for climatic conditions at the site, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.

2

-

-

... More
Supply and erection of lightning arrestor (set of 03), explusion type suitable for 11 kV continuous operating voltage (3 phase) with rated voltage 24 kV (rms) with nominal discharge capacity of 65 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed. Note- Lightning attester shall be able to withstand wind load of 196Kg/Sqm and seismic acceleration of 0.39g.

2

-

-

... More
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work in ornamental design etc. complete all as specified and directed by Engineer-in-charge.

590

-

-

... More
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.

319.14

-

-

... More
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.

1

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.

209.5

-

-

... More
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point

109.64

-

-

... More
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.

63.82

-

-

... More
Supply & laying unreinforced precast concrete cable cover class HV type 1, flat shape, dimension 300 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.

4432.5

-

-

... More
Supplying & fixing to walls and ceilings or laid in floors 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

30

-

-

... More
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI pipe of 65 mm to 100 mm nominal bore complete all as specified and as directed.

12

-

-

... More
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.

0.5

-

-

... More
M & L for cement concrete in foundation, sub base of floor filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

3

-

-

... More
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.

0.7

-

-

... More
Supply and fix for precast PCC cable route indicator duly marked and painted for HT/LT cable of size (80X25X7.5) cm with suitable size of base, embossed with lettering 'MES HT/LT cable' complete all as per specification and as directed.

40

-

-

... More
S & F in repair drop out fuse unit expulsion type for outdoor air brake gang operated switches single pole mounted and including insulator for 11 kV working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line taps and suitable for current carryout capacity 15 Amps.

2

-

-

... More
M&L for Lightning protection system based on proactive Early Streamer Emission (ESE) technology confirmg to NFC 17-102 - 2011 sept. and UNE 21186 Standards. Non electronics based device shall emit electromagnetic impulse in the form of a streamer into the air microseconds earlier than naturally. Device confirming to NFC17-102 standards. with following specification :- • Lightning Impulse Current(10/350 µs) is 100 KA. Air Terminal is be tested for an Impulse current (10/350 µs micro Sec wave form)= Ipeak = 125 kA ± 10%. • Material Metal Housing Stainless Steel 304 • Central Rod Dia 20mm Electromagnetic Shielding. • Can Be qualfied in Compliance of CPRI (Central Power Research Institute), Govt of India for the Impulse current of (8/20 µs) which is switching impulse current in 70 KA with 5 positive & 5 negative impulse. • Covering Radius Covering Radius 107 meter in level IV protection ( Standard Protection ) above 5mtr of mast complete all as specified and directed.

1

-

-

... More
Supply and Fix Lightening Air Terminal Adaptor of highly insulated polyplastic (FRP )adaptor to fix the lightning ESE air terminal with the mast. The adaptor shall have suitable metal connector/connecting point in such a way the top portion shall be electrically connected to the central finial/tip (elevated sharp tip) of the ESE air terminal and the bottom portion shall be connected to the down conductor complete all as specified and directed

1

-

-

... More
M&L for lighteningn strike counter Lightning Flash Counter working Electro mechanically without any power supply non resetable type with the minimum sensitivity of 250A to 100 kA including following specification. * Display Model :- Electromechanical display ( non- resettable ) * Display Range :- 000000 to 999999 * Detected Maximum Discharge Current :- 350 A, 10/350 microsecond wave ( measured according to NFC Standards 100 kA nominal current pulse.) * Dimension of Counter (cm) :- 16 (L) x 9 (w) x 6 (h) in (mm) :- 170 x 82 x 60 * Degree of Protection :- IP 67 ( IEC 529) * IP 67 rated enclosure suitable for external application. * Non-intrusive and fast acting proximity circuit detects lightning transient current. * Enclosure Material:-Plastic. Company-ETernity Energia Solutions, * Material :- Stainless Chrome (304)/ PVC with SS nut bolt and SS saddle plate for laying strip or cable * Total Weight :- 650 gram * Operating Temperature (˚C) :- -20 ~ +85 * Strike Count Display :- 6 Digit * Installation Location :- Lightning Protection Systems * Can be mounted at any location along the down conductor complete all as specified and directed

1

-

-

... More
Supply & Fix GI Mast for mounting the terminal & adaptor with the ESE Air Terminal in compliance with IEC 62561 -1 * GI Mast Length ( 3+3+2+2mtr= 10 mtr ) * Pipe Type - Cylindrical * Material - HDGI * Pipe Dia - 50mm approx * Standard - IS 1239 (Part 1) : 2004 * Base Plate - GI Base Plate size (300x300x6mm) Both the FRP and GI mast to be connected with the help of 4 GI Flange with 8 GI plated nut, bolt. The base plate size is (300x300x6mm) GI with requisite fitted with 4 ribs/ tikki to hold the mast complete all as specified and directed

1

-

-

... More
Supply and Fix Guy Wire Kit of Guy wire with GI Nickel coated 4 mm dia. covered with white sleeve for extra protection and avoiding rusting. Length of the guy wire is 6mtr x 3 no.=18 mtr with accessories like * Guy Wire Nickel coated with white covered waterproof sleeve-18 mtr * U Clips - 6 Nos. * Pin Type Zebra Anchor Fastner- 4 Nos. * O Hook Fastner/ Eye Bolt Fastner - 3 Nos.etc. * GI Nut Bolt - Dia 12mm x Length 40mm- 8 nos complete all as specified and directed

1

-

-

... More
Supply and Fix Test Link of non corroding weather proof, water proof and dust proof polycarbonate / polystyrene IP 65 / IP 55 (in accordance with IEC 60670-22 standard) including providing of 2 numbers of insulated supports, 25 x 3 mm thick copper strip with suitable holes prefitted SS bolt & nuts to fix the down conductor & earth wire. The dimension shall be as per below specifications:- Dia - 138 mm approx. Width - 150 mm approx. Height - 150 mm approx. complete all as per specification and as directed.

1

-

-

... More
Supply and fix Chemical Earthing system of Tripod Advance chemical gel earthing system of 01 number of any UL Listed & CPRI Tested copperbonded rod shall be 10 feet long 17 mm dia 250 micron copper bonded steel rod surrounded with 50 Kg each or more quantity of resistance lowering grounding minerals, well interconnected with suitable copper strip to form a triangle shape (distance between the rods shall be the length of the rod. The electrode will be Ground enhancing compound which shall be Eco-frendly. * Product Material- Copper bonded High Tensile low carbon steel solid Rod * Copper purity is 99.9% * Copper grade is as per IS 191 * Copperbonded Rod with outer surface 254-micron copper bonding in shank area with Arch Welded clamp Rod Arc Duly Welded with Strip Size (175x50x5)mm Copper bonding with 70-micron Copper bonded Rod. * Copperboned Rod Dia- 17 mm complete all as per specification and as directed.

11

-

-

... More
M& L for Earth Enhancement Compound- * Product-Maintenance free Chemical compound of 25 kg Bag each * Standard - As per IS - 3043 and IEEE80- 2000, * Test certificate from NABL Lab * Resistivity after compression- 0.0752 ohms per mtr. * Solubility in Water- 0.94 * Chemical composition - As per IS Standard * Retaining Moisture Capacity (Ph Value)- 7.12 * ROHS Complying IEC 62561-7.complete all as specified and directed

11

-

-

... More
M&L for Pit Chamber- Round Value Box:- Supply of Poly Plastic heavy duty U V resistant, weather proof environment friendly earth pit cover with cover of auto-locking facility with 2 knock-out openings are provided for the easy strips between the earth pits. • At Top (Dia)- 162 mm • At Bottom ( Dia )- 242 mm • Height - 230 mm • Tested from NABL Lab in 9 Ton weight carrying capacity complete all as specified and directed

11

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.