Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 14,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Compressor Sealed Unit 12.5 TR Capacity suitable for R407C/ R22 Refrigerant, 3 Phase 415 Volt, Flushing Old Gas and Charging/ Filling with appropriate Quantity of R407C/ R22 Refrigerant Gas, Providing all Electrical Connections including Taking down Defective Compressor after disconnecting Electrical Connections, complete all as specified and as directed. MAKE : DANFOSS or equivalent as approved by GE

2

-

-

... More
S&F Fin Type Strip Heater (as per existing or as approved by GE) suitable Rating for use in 10400 CFM AHU, Providing Connection including Taking down/ out Unserviceable Strip Heater of any description, complete all as specified and as directed.

10

-

-

... More
S&F Fine Filter of Size 610x610x305mm with Dust Arrestance at 80 to 90% @ 0.3 micron including Taking down/ out Unserviceable One, complete all as specified and as directed. MAKE : THERMADYNE or equivalent as approved by GE

12

-

-

... More
S&F PVC Cooling Tower Fills of Size 600x300x150mm, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed.

180

-

-

... More
S&F Pre-filter of Size 610x610x50mm with Dust Arrestance at 90% @ 10 micron including Taking down/ out Unserviceable One, complete all as specified and as directed. MAKE : THERMADYNE or equivalent as approved by GE

12

-

-

... More
S&F Pressure Gauge with Gauge Pressure Reading Range between 0 Kg/Sq Cm to 14 Kg/Sq Cm, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed. MAKE : H GURU or equivalent as approved by GE

10

-

-

... More
S&F Single Phase Preventer Working on 3 Phase 440 Supply including Taking down/ out Unserviceable One, complete all as specified and as directed. MAKE : BCH/GE/ L&T/ SIEMENS

3

-

-

... More
S&F Temperature Gauge with Temperature Reading Range between 0 ºC to 50 °C, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed. MAKE : JASPIN or equivalent as approved by GE

6

-

-

... More
S&F Temperature and Humidity Meter suitable for Reading for Temperature and Humidity including Taking down Unserviceable One, complete all as specified and as directed. MAKE : HTC or equivalent as approved by GE

3

-

-

... More
M&L for Disconnecting Mechanical Connection, Taking out Carefully from Chiller Centrifugal Pumps of Power Consuming Capacity 2.2 KW, Repairing by Replacing Unserviceable Ball Bearings at DE & NDE Ends, Star Coupling and Sealing Non Drive Ends with Gland, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed.

2

-

-

... More
M&L for Disconnecting Mechanical Connection, Taking out Carefully from Condensor Centrifugal Pumps of Power Consuming Capacity 5.5 KW, Repairing by Replacing Unserviceable Ball Bearings at DE & NDE Ends, Star Coupling and Sealing Non Drive Ends with Gland, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed.

2

-

-

... More
M&L for Disconnecting Mechanical Connection, Taking out Carefully from Cooling Tower Fan of Power Consuming Capacity 5.5 KW, Repairing by Replacing Unserviceable Ball Bearings at DE & NDE Ends, Star Coupling and Sealing Non Drive Ends with Gland, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed.

1

-

-

... More
M&L for Disconnecting Mechanical Connection, Taking out Carefully from Cooling Tower Fan of Power Consuming Capacity 7.5 KW, Repairing by Replacing Unserviceable Ball Bearings at DE & NDE Ends, Star Coupling and Sealing Non Drive Ends with Gland, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed.

2

-

-

... More
M&L for Taking down Carefully Burnt out Electric Driven Chiller Water Pump Motor 3.0 HP Capacity from Foundation Channel after Disconnecting Main Electric Supply from the Motor Starter Panel, Dismantling Motor Carefully and Display all the Parts/Components in Presence of BOO (To be ordered by GE) to ascertain the Serviceability of existing Parts and Repairs/ Replacement of Unserviceable/ Defective Parts, Removing to nearest Workshop for Repairing, Taking out Burnt Coils from the Slots of Stator, Other Accessories such as Ball Bearing, Rotor, Cleaning the Stator Slots and Rewinding the Same with New Supper Enameled Copper Winding Wire of Make : Devidayal (or as approved by GE) with appropriate Gauge and Quantity, Heating, Varnishing with Doctor Beck's insulated Varnish, Re-assembling the Same after Greasing the Ball Bearing Motor, Refixing to Original Position after Repairing from Workshop, Re-installation on existing Channel & Re-connecting to Electric Supply, Commissioning and Testing, complete all as specified and as directed.

2

-

-

... More
M&L for Taking down Carefully Burnt out Electric Driven Condensor Pump Motor/ Cooling Tower Pump Motor 7.5 HP Capacity from Foundation Channel after Disconnecting Main Electric Supply from the Motor Starter Panel, Dismantling Motor Carefully and Display all the Parts/Components in Presence of BOO (To be ordered by GE) to ascertain the Serviceability of existing Parts and Repairs/ Replacement of Unserviceable/ Defective Parts, Removing to nearest Workshop for Repairing, Taking out Burnt Coils from the Slots of Stator, Other Accessories such as Ball Bearing, Rotor, Cleaning the Stator Slots and Rewinding the Same with New Supper Enameled Copper Winding Wire of Make : Devidayal (or as approved by GE) with appropriate Gauge and Quantity, Heating, Varnishing with Doctor Beck's insulated Varnish, Re-assembling the Same after Greasing the Ball Bearing Motor, Refixing to Original Position after Repairing from Workshop, Re-installation on existing Channel & Re-connecting to Electric Supply, Commissioning and Testing, complete all as specified and as directed.

3

-

-

... More
M&L for Taking down Carefully Burnt out Electric Driven Blower Motor 10 HP Capacity from Foundation Channel after Disconnecting Main Electric Supply from the Motor Starter Panel, Dismantling Motor Carefully and Display all the Parts/Components in Presence of BOO (To be ordered by GE) to ascertain the Serviceability of existing Parts and Repairs/ Replacement of Unserviceable/ Defective Parts, Removing to nearest Workshop for Repairing, Taking out Burnt Coils from the Slots of Stator, Other Accessories such as Ball Bearing, Rotor, Cleaning the Stator Slots and Rewinding the Same with New Supper Enameled Copper Winding Wire of Make : Devidayal (or as approved by GE) with appropriate Gauge and Quantity, Heating, Varnishing with Doctor Beck's insulated Varnish, Re-assembling the Same after Greasing the Ball Bearing Motor, Refixing to Original Position after Repairing from Workshop, Re-installation on existing Channel & Re-connecting to Electric Supply, Commissioning and Testing, complete all as specified and as directed.

2

-

-

... More
M&L Mild Steel Frame Work/Brackets of Angles or Tees with Web and Flanges, Cut to Shape, Drilled and Countersunk for Screw including Bending and Welding Angles as necessary, Gusset Plates, Riveting, etc., Conforming to Fe-290, Gde-E-165 including Dismantling Unserviceable Framed Work of any description, complete all as specified and as directed.

50

-

-

... More
Supply, Assembly & Erection of GI Sheet 22 Gauge thick with TDF Flange Rectangular/ Square Duct (as per existing Size & Shape) made out of 'L' shaped Hollow Profile, Duly factory Boxed including all Accessories such as Cornet, Cleat, Carriage Bolt, Gasket and Appropriate Sealant on Longitudinal Joints, etc. including Dismantling Unserviceable GI Sheet with TDF Flange Work of any description, complete all as specified and as directed

30

-

-

... More
M&L Duct Insulation 25mm thick with Resin Bonded Fiber Glass Wool Roll of Density 24 Kg/ Cum, with Factory Laminated Aluminium Vapor Barrier, Comprising with the following:- (a) Cleaning the Duct Surface (to be insulated) by Scrapping Carefully with Wire Brush, etc. to make the Surface Completely Free of Mill Scale, Dirt’s, Dust, Grease and Other Foreign Materials, Taking Special Care so that all Duct Joints are Sealed against any Leakage. (b) Applying Rubber Based Adhesive CPRX Compound. (c) Sealing of all Longitudinal Joints and Circular Overlaps with and including Aluminium Foil Tape 50mm Wide to make the Insulation Leak Proof. (d) Securing the Insulation with and including Mechanically Fastened Nylon/ Steel Straps of Size 12mm/50mm at Maximum Intervals of 1.20 Metre.

30

-

-

... More
S&F MS ERW Pipe 100mm bore (dia), laid in Floor or fixed to Wall and Ceiling with all necessary Connecting Items, etc. including Taking Down Old Unservice-able Pipe with Connecting Items, etc., complete all as specified and as directed.

18

-

-

... More
S&F Cable Tray made out of GI Metal Sheets 2.0mm thick having 50mm in Breadth and 38mm in Height including Fixing Brackets, Riser, etc. after Taking down/ out Unserviceable Cable Tray of any description, complete all as specified and as directed.

60

-

-

... More
M&L Preparing External Surfaces of MS ERW Pipe and Applying Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.

50

-

-

... More
S&F Ball Brass Valve 25mm bore (dia), ISI marked, High Pressure with Polythene Float and Fly-nuts, Screwed for Iron Pipe or Brass Ferrule and fixed including Taking down Old Unserviceable Ball Valve of any description, complete all as specified and as directed.

3

-

-

... More
S&F Gun Metal Gate Valve 25mm bore (dia), ISI marked, with Iron Wheel Head, Screwed for Iron Pipe with Union and fixed including Taking down Old Unserviceable Gate Valve of any description, complete all as specified and as directed.

3

-

-

... More
S&F Cast Iron Butterfly Valve 65mm Nominal Bore ISI marked including Rubber/ Fiber Board Gasket, Nuts, Washers, etc. including Taking down Old Unserviceable Butterfly Valve, complete all as specified and as directed.

3

-

-

... More
S&F Cast Iron Butterfly Valve 100mm Nominal Bore ISI marked including Rubber/ Fiber Board Gasket, Nuts, Washers, etc. including Taking down Old Unserviceable Butterfly Valve, complete all as specified and as directed.

3

-

-

... More
REPAIRS/ MAINT TO PANELS

-

-

-

... More
M&L for Repairing LT Panel (for AC Plant) by Replacing New Internal Wiring, Wire Lugs, Copper Bus-bars, etc. with Existing/ Appropriate Size and All Unserviceable Parts after Disconnecting All Electric Supply Connections including Applying One Coat of Synethetic Enamel Paint with Spray Machine, Writing MES No./ any description in distinctly if any required, Providing All Electric Supply Connections after Repaired and Painting, Testing on Completion, complete all as specified and as directed.

1

-

-

... More
S&F Contactor with AC3 Rating 25 Amp & AC1 Rating 45 Amp, Providing Connection including Taking down/ out Old Unserviceable One, complete all as specified and as directed. MAKE : BCH/GE/ L&T/ SIEMENS

4

-

-

... More
S&F Electronic Timer Working on 240 Volt AC, 50 Hz with Timing Range 3 Sec to 120 Sec including Taking down/ out Unserviceable One, complete all as specified and as directed.

3

-

-

... More
S&F MCCB 25 Amp to 100 Amp, 3 Pole, 415 Volt, 16 kA Breaking Capacity, 50 Hz suitable for fixing in LT Panel of Central and Package AC Plant and Providing Connection including Taking down Unserviceable One, complete all as specified and as directed.

2

-

-

... More
S&F MCCB 160 Amp, 4 Pole, 36 kA, 415Volt, 50Hz Capacity suitable for LT Panel of Central & Package type AC Plant including Taking down Old Unserviceable MCCB, complete all as specified and as directed.

2

-

-

... More
S&F MCCB 200 Amp, 4 Pole, 415 Volt, 36 kA Breaking Capacity, 50Hz suitable for fixing in LT Panel of Central and Package AC Plant and Providing Connection including Taking down Unserviceable One, complete all as specified and as directed.

1

-

-

... More
S&F Thermal Overload Relay suitable for fixing with Contactor with Relay Range between 1.4 to 2.3 Ampere, Providing Connection including Taking down/ out Old Unserviceable Relay of any description, complete all as specified and as directed. MAKE : BCH/GE/ L&T/ SIEMENS

1

-

-

... More
S&F Thermal Overload Relay suitable for fixing with Contactor with Relay Range between 4.7 to 7.5 Ampere, Providing Connection including Taking down/ out Old Unserviceable Relay of any description, complete all as specified and as directed. MAKE : BCH/GE/ L&T/ SIEMENS

2

-

-

... More
S&F Thermal Overload Relay suitable for fixing with Contactor with Relay Range between 6.0 to 10 Ampere, Providing Connection including Taking down/ out Old Unserviceable Relay of any description, complete all as specified and as directed. MAKE : BCH/GE/ L&T/ SIEMENS

1

-

-

... More
Supply & Fixing or Laying or Passing through Pipe XLPE Insulated, Armoured, Heavy Duty Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-Sectional Area 25 Sqmm, 3 Core, Providing Connection including Taking down/ Out Old Unserviceable Cable from any Situation, complete all as specified and as directed.

120

-

-

... More
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of Size 25x4.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI Protection Pipe 40mm bore (dia) 'Light grade', Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 450x450x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), Reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, Mild Steel Round Bar 10mm dia Handle (01 No.), GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) 'Medium grade' including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of Surplus Spoil upto a distance of 50 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Unserviceable GI Earth Strip Wire Earthing, complete all as specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.

4

-

-

... More
DEDUCT/ LESS AGAINST SCHEDULE OF CREDIT

-

-

-

... More
Bidders shall Quote the EQUAL AMOUNT (as mentioned in SCHEDULE OF CREDIT of TENDER DOCUMENTS) under Column 'UNIT RATE' (M) against Row No. 55.

1

-

-20200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.