Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date8 Oct 2024
Closing Date2 Nov 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Comprehensive maintenance of 05 Ton capacity EOT crane installed at different buildings/ locatios,restoring the cranes in serviceable condition through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved, complete all as specified and directed with and including opeartions for maintenance specified as under:- (A) LONG TRAVERSE MOTION/CROSS TRAVERSE MOTION/HOIST MOTION- (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all LT motion of three phase electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (B) ELECTRICALS (a) Checking and tightening all electric connections (b) Checking the contactors/ relays etc for overheating or flashinng. (c) Clening off all connection and control cables. (d) Bunching the loose control cable properly . (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth working. (C) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/over heated connections, general cleaning and checking all the functions of the LT/CT/Hoist motion push buttons and lights/VVVF switch including reassembling the unit complete

1

-

-

... More
LOAD TESTING:- Load testing complete for LT/CT/Hoist motion of the 5 Ton EOT cranes ( Installed at different locations with in TA complex) for 125% capacity using any type of dead weight complete and as directed. Notes:- 1. Necessary weights will be arranged by the MES. 2. Shifting of load at site and shifting to different buidings/ locations with in the complex using truck/mobile crane etc of suitable capacity shall be arranged by the contractor. 3. Tools, tackles ,chains and sling etc of suitable capacity required for load testing shall be arranged by the contractor. 4. Unit rate quoted shall be inclusive of adjustment of brakes, motors, gear boxes,electrical system, load hook, steel wire ropes, limit switches and all related items. 5. OEMs for EOT Cranes: Ramc Crane/ Safex Industries Ltd./Microtech 6.) Contractor shall produced serviceability certificate after servicing /repairing ,duly signe by user and deposit the same to the Dept for payment purpose .7.)Works shall be executed through specialist firm who was sufficient experienced on the scope of work. Before commencement of work, approval shall be obtained from the GE 8.) Service Engineer shall visit minimum once in a month and take serviceability certificate duly signed by the user. 9.. Each maintenance job shall be covered period of 06 Months

-

-

-

... More
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of six months of 10 Ton capacity EOT crane installed at different buildings/ locatios,restoring the cranes in serviceable condition through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved, complete all as specified and directed with and including opeartions for maintenance specified as under:- (A) LONG TRAVERSE MOTION/CROSS TRAVERSE MOTION/HOIST MOTION- (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all LT motion of three phase electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (B) ELECTRICALS (a) Checking and tightening all electric connections (b) Checking the contactors/ relays etc for overheating or flashinng. (c) Clening off all connection and control cables. (d) Bunching the loose control cable properly . (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth working. (C) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/over heated connections, general cleaning and checking all the functions of the LT/CT/Hoist motion push buttons and lights/VVVF switch including reassembling the unit complete

1

-

-

... More
LOAD TESTING:- Load testing complete for LT/CT/Hoist motion of the 10 Ton EOT cranes ( Installed at different locations with in TA complex) for 125% capacity using any type of dead weight complete and as directed. Notes:- 1. Necessary weights will be arranged by the MES. 2. Shifting of load at site and shifting to different buidings/ locations with in the complex using truck/mobile crane etc of suitable capacity shall be arranged by the contractor. 3. Tools, tackles ,chains and sling etc of suitable capacity required for load testing shall be arranged by the contractor. 4. Unit rate quoted shall be inclusive of adjustment of brakes, motors, gear boxes, electrical system, load hook, steel wire ropes, limit switches and all related items. 5. OEMs for EOT Cranes: Ramc Crane/ Safex Industries Ltd./Microtech 6.) Contractor shall produced serviceability certificate after servicing /repairing ,duly signe by user and deposit the same to the Dept for payment purpose .7.)Works shall be executed through specialist firm who was sufficient experienced on the scope of work. Before commencement of work, approval shall be obtained from the GE 8.) Service Engineer shall visit minimum once in a month and take serviceability certificate duly signed by the user. 9.. Each maintenance job shall be covered period of 06 Months

-

-

-

... More
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of six months of 10 Ton capacity flame proof EOT crane installed at different buildings/ locatios,restoring the cranes in serviceable condition through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved, complete all as specified and directed with and including opeartions for maintenance specified as under:- (A) LONG TRAVERSE MOTION/CROSS TRAVERSE MOTION/HOIST MOTION- (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in FLP thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all LT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (B) ELECTRICALS (a) Checking and tightening all electric connections (b) Checking the contactors/ relays etc for overheating or flashinng. (c) Clening off all connection and control cables. (d) Bunching the loose control cable properly . (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth working. (C) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/over heated connections, general cleaning and checking all the functions of the LT/CT/Hoist motion push buttons and lights/VVVF switch including reassembling the unit complete

5

-

-

... More
LOAD TESTING:- Load testing complete for LT/CT/Hoist motion of the 10 Ton EOT cranes ( Installed at different locations with in TA complex) for 125% capacity using any type of dead weight complete and as directed. Notes:- 1. Necessary weights will be arranged by the MES. 2. Shifting of load at site and shifting to different buidings/ locations with in the complex using truck/mobile crane etc of suitable capacity shall be arranged by the contractor. 3. Tools, tackles ,chains and sling etc of suitable capacity required for load testing shall be arranged by the contractor. 4. Unit rate quoted shall be inclusive of adjustment of brakes, motors,gear boxes,electrical system, load hook, steel wire ropes,limit switches and all related items. 5. OEMs for EOT Cranes: Ramc Crane/ Safex Industries Ltd./Microtech 6.) Contractor shall produced serviceability certificate after servicing /repairing ,duly signe by user and deposit the same to the Dept for payment purpose .7.)Works shall be executed through specialist firm who was sufficient experienced on the scope of work. Before commencement of work, approval shall be obtained from the GE 8.) Service Engineer shall visit minimum once in a month and take serviceability certificate duly signed by the user. 9.. Each maintenance job shall be covered period of 06 Months

-

-

-

... More
Supply,installation,testing and commissioning of weight operated limit switch,aluminium body, current rating 40 Amps,440 Volts,Degree of Protection IP-55,Confirming to IS-13947 (Part)-1993 for control of power circuit of reversing drives of 10 Ton capacity EOT Cranes to limit their rotation/position within a predetermined position all as per OEM's specifications,including taking down existing unserviceable limit switch,complete all as specified and as directed.

5

-

-

... More
Supply,installation,testing and commissioning of weight operated Flame Proof limit switch,aluminium body,current rating 40 Amps,440 Volts,Degree of Protection IP-55,Confirming to IS-13947 (Part)-1993 for control of power circuit of reversing drives of 10 Ton capacity Flame Proof EOT Cranes to limit their rotation/position within a predetermined position all as per OEM's specifications, including taking down existing unserviceable limit switch,complete all as specified and as directed.

4

-

-

... More
Supply,installation,testing and commissioning of Flame Proof,Cast Iron Body, Electro Hydraulic Thruster,Capacity 18 Kg with 3 Phase electric motor, 415 Volts,50 Hz,centrifugal impeller,piston etc. suitable for Flame Proof EOT Cranes to exert a constant force during operation all as per OEM's specifications,including taking down existing unserviceable thrustor unit,complete all as specified and as directed.

4

-

-

... More
Supply Only,Industrial Gear Oil, ISO Viscocity Grade 680,all as specified. (Make: Castrol/Bosch/Servo/Gulf) Notes:- (i) Gear Oil shall be supplied in sealed HDPE containers of 5 Litres/20 Litres. (ii) For filling in as required under BOQ Serial Item No 1 to 5

80

-

-

... More
Supply and Fix in repairs,Brake Liner (Friction Pad Lining for Brake Shoes) set suitable for 100 mm dia brake drum for LT/CT motion of 10 Ton capacity EOT crane all as per OEM's specifications, complete all as specified and directed.

4

-

-

... More
Supply and Fix in repairs,Brake Liner (Friction Pad Lining for Brake Shoes) set suitable for 160 mm dia brake drum for LT/CT motion of 10 Ton capacity EOT crane all as per OEM's specifications, complete all as specified and directed.

4

-

-

... More
Supply and Fix in repairs,Brake Liner (Friction Pad Lining for Brake Shoes) set suitable for 150 mm dia brake drum for hoist motion of 10 Ton capacity EOT crane all as per OEM's specifications, complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Brake Liner (Friction Pad Lining for Brake Shoes) set suitable for 200 mm dia brake drum for hoist motion of 10 Ton capacity EOT crane all as per OEM's specifications, complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Torque Spring suitable for electro hydraulic brake assembly with 100 mm dia. Brake Drum and and breaking torque 6 Kg-m suitable for drum brakes of LT/CT motion of EOT Cranes all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Torque Spring suitable for electro hydraulic brake assembly with 160 mm dia. Brake Drum and and breaking torque 9 Kg-m suitable for drum brakes of LT/CT motion of EOT Cranes all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Torque Spring suitable for electro hydraulic brake assembly with 200 mm dia. Brake Drum and and breaking torque 20 Kg-m suitable for drum brakes of LT/CT motion of EOT Cranes all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Power Contactors for 3 Pole AC Control,conforming to IEC 60947-4-1,Rated Operational Current AC1 rating 25 Amps and AC3 rating 12 Amps,coil voltage 110 Volts AC with auxillary contacts 1NO/1NC,complete all as specified and directed. [Cat No. LC1E1201 F7/LC1E1210 F7 of Make Schneider or equivalent Model of Make ABB/Seimens/L&T]

6

-

-

... More
Supply and Fix in repairs,Power Contactors for 3 Pole AC Control,conforming to IEC 60947-4-1,Rated Operational Current AC1 rating 50 Amps and AC3 rating 32 Amps,coil voltage 110 Volts AC with auxillary contacts 1NO/1NC,complete all as specified and directed. [Cat No. LC1E3201 F7/LC1E3210 F7 of Make Schneider or equivalent Model of Make ABB/Seimens/L&T]

2

-

-

... More
Supply and Fix in repairs, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MO 12, AC-3 rating 32 Amps and AC-1 rating 12 Amps with auxillary contacts 1 NO + 1 NC,complete all as specified and directed. [Cat No.CS94834 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

2

-

-

... More
Supply and Fix in repairs, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MO 25, AC-3 rating 45 Amps and AC-1 rating 25 Amps with front mounting add on auxillary contacts 1NO + 1NC,Type MO 9-110 /MO0,complete all as specified and directed. [Cat No.CS94567 (For Contactor) CS94592 (For Auxillary Contact) of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

2

-

-

... More
Supply and Fix in repairs, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MO 32, AC-3 rating 50 Amps and AC-1 rating 32 Amps with front mounting add on auxillary contacts 1NO + 1NC,Type MO 9-110 /MO0,complete all as specified and directed. [Cat No.CS94568 (For Contactor) CS94592 (For Auxillary Contact) of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

2

-

-

... More
Supply and Fix in repairs, MS coupling 25 mm dia with nuts ,bolts and bushes suitable for LT/CT motors of EOT Cranes all as per OEM's specifications,complete all as specified and directed.

3

-

-

... More
Supply and Fix in repairs, MS coupling 50 mm dia with nuts ,bolts and bushes suitable for drive shafts of gear box in EOT Cranes all as per OEM's specifications,complete all as specified directed

2

-

-

... More
Dismantaling of hoisting motor,3 Phase,3 HP capacity,from EOT Cranes,removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor with super enamelled copper wires of existing size/gauge including provision of all insulating materials,lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling,including testing and commissioning, complete all as specified and directed.

1

-

-

... More
Dismantaling of hoisting motor,3 Phase, 5 HP capacity,from EOT Cranes,removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor with super enamelled copper wires of existing size/gauge including provision of all insulating materials,lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling,including testing and commissioning, complete all as specified and directed.

1

-

-

... More
Comprehensive Maintenance of voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type of capacity 30 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved,by disconnecting of all incomming and out going electrical connections and earthing lead connections,opening of top cover carefully,cleaning of servo motor,service connection,gear penion and replacement of minor spares such as fuse,diode,carbon brushs,holder,internal electrical wiring and electronic accessories and insulated properly by varnishing,greasing,CRC spraying,internal electrical connections,draining and filtration of transformer oil including refilling the same after through cleaning of oil tank,replacing spares such as gaskets,rubber oil seals,etc all as per OEMs reccommendations,re-assembling and re-connection of electrical system,including testing and commissioning,complete all as specified and directed. [OEMs:- Volina/Hindustan/Servocon]

3

-

-

... More
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of six months of voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type of capacity 75 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved,by disconnecting of all incomming and out going electrical connections and earthing lead connections,opening of top cover carefully, cleaning of servo motor,service connection,gear penion and replacement of minor spares such as fuse,diode,carbon brushs,holder,internal electrical wiring and electronic accessories and insulated properly by varnishing,greasing,CRC spraying,internal electrical connections,draining and filtration of transformer oil including refilling the same after through cleaning of oil tank, replacing spares such as gaskets,rubber oil seals,etc all as per OEMs reccommendations,re-assembling and re-connection of electrical system,including testing and commissioning,complete all as specified and directed. [OEMs:- Volina/Hindustan/Servocon] 6.) Contractor shall produced serviceability certificate after servicing /repairing ,duly signe by user and deposit the same to the Dept for payment purpose .7.)Works shall be executed through specialist firm who was sufficient experienced on the scope of work. Before commencement of work, approval shall be obtained from the GE 8.) Service Engineer shall visit minimum once in a month and take serviceability certificate duly signed by the user. 9.. Each maintenance job shall be covered period of 06 Months

2

-

-

... More
Comprehensive Maintenance of voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type of capacity 200/250 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved,by disconnecting of all incomming and out going electrical connections and earthing lead connections,opening of top cover carefully, cleaning of servo motor,service connection,gear penion and replacement of minor spares such as fuse,diode,carbon brushs,holder,internal electrical wiring and electronic accessories and insulated properly by varnishing,greasing,CRC spraying,internal electrical connections,draining and filtration of transformer oil including refilling the same after through cleaning of oil tank, replacing spares such as gaskets,rubber oil seals,etc all as per OEMs reccommendations,re-assembling and re-connection of electrical system,including testing and commissioning,complete all as specified and directed. [OEMs:- Volina/Hindustan/Servocon]

1

-

-

... More
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of six months of voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type of capacity 500/630 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved,by disconnecting of all incomming and out going electrical connections and earthing lead connections,opening of top cover carefully, cleaning of servo motor,service connection,gear penion and replacement of minor spares such as fuse,diode,carbon brushs,holder,internal electrical wiring and electronic accessories and insulated properly by varnishing,greasing,CRC spraying,internal electrical connections,draining and filtration of transformer oil including refilling the same after through cleaning of oil tank, replacing spares such as gaskets,rubber oil seals,etc all as per OEMs reccommendations,re-assembling and re-connection of electrical system,including testing and commissioning,complete all as specified and directed. [OEMs:- Volina/Hindustan/Servocon] Notes:-(Applicable for BOQ Serial Item No 26 to 29) (i) Spares for replacement except the minor spares mentioned in the description of the item (s) will be measured and paid separately under relevent items of this BOQ. (ii) Testing of servo voltage stabilizer as per OEMs specifications shall be done in presence of Engr-in-Charge and test report(s) duly signed by Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies shall be furnished by the Contractor. (iii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately under relevant items of this BOQ. (iv) Topping up of oil tank with new transformer oil if required will be measured and paid separately under relevant item of this BOQ.However the quoted rate is deemed to be inclusive of the rate for filteration and dehydration of the existing transformer oil.

1

-

-

... More
Supply Only,Digital Potentiometer,Resistance (Ω) 0-10K,Interface Type I2C,Digital Operating Voltage 3.3V to 5V,Analog Operating Voltage 4.5V to 15.5V suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/AE]

1

-

-

... More
Supply Only, 3 Phase LED Ammeter, Accuracy Class 1.0, Aux supply 80-300 VAC, CT secondary site selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch all as specified. [Cat No. WL131010OOOO of Make “L&T” or equivalent Model of Make HPL/ AE ]

1

-

-

... More
Supply Only, 3 Phase LED Voltmeter, Accuracy Class 1.0, Input voltage measurement range 50-550 VAC (P-P), Aux supply 80-300 VAC, CT secondary site selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch all as specified. [Cat No. WL132010OOOO of Make “L&T” or equivalent Model of Make HPL/ AE]

1

-

-

... More
Supply Only,P C B Holder suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

5

-

-

... More
Supply Only,Single Phase,100-280 Volt AC, 2 Pole,Foot Mounted Servo Synchronous Motor,60 RPM,Torque 3 Kg, efficiency 98%,suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

4

-

-

... More
Supply Only,Single Phase,100-280 Volt AC, 2 Pole,Foot Mounted Servo Synchronous Motor,60 RPM,Torque 10 Kg, efficiency 98%,suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

2

-

-

... More
Supply Only,Single Phase,100-280 Volt AC, 2 Pole,Foot Mounted Servo Synchronous Motor,60 RPM,Torque 20 Kg, efficiency 98%,suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

1

-

-

... More
Supply Only,Carbon Brush (20 Amps to 200 Amps) suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

6

-

-

... More
Supply Only,Carbon Holder & Spring suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

3

-

-

... More
Supply Only, Servo motor gear pinion suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

5

-

-

... More
Supply Only, R C Net work for 10 Kg Motor suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

3

-

-

... More
Supply Only,R C Net work for 20 Kg Motor suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

2

-

-

... More
Supply Only, Drive assembly 75 Kva per phase suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

4

-

-

... More
Supply Only, Drive assembly 200/250 KVA per phase suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

2

-

-

... More
Supply Only, Digital Control Panel with Circuit board for high / low Voltage cut per phase suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type of capacity upto 75/200/250/500/ 630KVA all as per OEM's specifications,complete all as specified. [OEMs:-Volina/Hindustan/Servocon].

9

-

-

... More
Supply Only,front control with wiring kit suitable for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type all as per OEM's specifications, complete all as specified. [OEMs:-Volina/Hindustan/Servocon]

2

-

-

... More
Materials and labour for,rewinding of Variac Dimmer Starter (Barrier) for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type, rating 30 KVA with super enameled /paper coated copper wire/strip of existing gauge/size and provision of all associated insulating materials such as separator,sleeves etc,varnishing all as per OEM's specifications,complete all as specified and as directed. [OEMs:-Volina/Hindustan/Servocon]

2

-

-

... More
Materials and labour for,rewinding of Variac Dimmer Starter (Barrier) for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type, rating 75 KVA with super enameled /paper coated copper wire/strip of existing gauge/size and provision of all associated insulating materials such as separator,sleeves etc,varnishing all as per OEM's specifications,complete all as specified and as directed. [OEMs:-Volina/Hindustan/Servocon]

1

-

-

... More
Materials and labour for,rewinding of Variac Dimmer Starter (Barrier) for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type, rating 200/250 KVA with super enameled /paper coated copper wire/strip of existing gauge/size and provision of all associated insulating materials such as separator,sleeves etc,varnishing all as per OEM's specifications,complete all as specified and as directed. [OEMs:-Volina/Hindustan/Servocon]

1

-

-

... More
Materials and labour for,rewinding of Variac Dimmer Starter (Barrier) for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type, rating 500/630 KVA with super enameled /paper coated copper wire/strip of existing gauge/size and provision of all associated insulating materials such as separator,sleeves etc,varnishing all as per OEM's specifications,complete all as specified and as directed. [OEMs:-Volina/Hindustan/Servocon]

1

-

-

... More
Materials and labour for,rewinding of Transformer Assembly for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type, rating 75 KVA with super enameled /paper coated copper wire/strip of existing gauge/size and provision of all associated insulating materials such as separator,sleeves etc,varnishing all as per OEM's specifications,complete all as specified and as directed. [OEMs:-Volina/Hindustan/Servocon]

1

-

-

... More
Materials and labour for,rewinding of Transformer Assembly for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type, rating 200/250 KVA with super enameled /paper coated copper wire/strip of existing gauge/size and provision of all associated insulating materials such as separator,sleeves etc,varnishing all as per OEM's specifications,complete all as specified and as directed. [OEMs:-Volina/Hindustan/Servocon]

1

-

-

... More
Dehydration,filtration, de-sludge of transformer oil in situ for voltage stabilizer for automatic operation (Servo Controlled), three phase,naturally oil cooled indoor type of any rating,by means of centrifugal filtration plant to achieve dielectric strength not less than 40 KV (rms) with gap of 2.5 mm, complete all as specified and directed. (NOTE: Transformer oil used for topping up will be measured and paid separately)

630

-

-

... More
Supply,filling in, dehydration and filtration of new transformer oil,having dielectric strength not less than 40 KV (rms) with gap of 2.5 mm, conforming to IS: 335-1993, for topping up /replacement of transformer oil complete all as specified and directed. (Make: Shell/Gulf/Power Oil/Servo)

980

-

-

... More
Comprehensive Maintenance of Fire Fighting System through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, comprising of Diesel Engine Operated Pump Set,Electric Motor Pump Set,Jockey Pump Set of different capacities by Checking,Periodic Inspection,Periodic Maintenance/Servicing as per OEM's reccommendations including cleaning,Oiling,Greasing, topping up, calibration, repairs to diesel engine and replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, minor calibration of fuel injection pump in situ,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including repair/replacement off toggle switch etc & connected accessoriesreplacement of unserviceable parts of the Diesel Engine Operated Pump Set,replacement/topping up of Engine Oil,Coolent, tightening/adjustment of V-Belt/Fan belt,replacement of fuel filter,lubricant filter,air filter etc. Attending emergency breakdown in system i.e Engine,Radiator, Self Starter, FIP etc for efficient functioning including provision of all consumables items like cotton, waste cloth, kerosine oil etc., cleaning of equipments in the installations alongwith valves including cleaning of inside and outside areas of the respective Fire Fighting Equipment Station, maintenance of wash out of inlet & outlet pipe line,repairing of NRV for leakage,replacement of gland packing, tightening/adjustment of pump motor couplings maintenance of suction and delivery pipe lines,primary fill up of priming tanks at different locations including all testing(s),complete all as specified and as directed. [MPR,PTT,Transmitter and ATC Loctions:- Diesel Engine Driven Pump Set 28/38 KW/HP,30 Metre Head,2280 LPM-01(One) No.in each location, Electric Motor Pump Set 30 HP,30 Metre Head,2280 LPM-01(One) No.in each location and Jockey Pump Set 5 HP,30 Metre Head,200 LPM-01(One) No.in each location; Brahmos Loction:- Diesel Engine Driven Pump Set 28/38 KW/HP,70 Metre Head,2280 LPM-01(One) No., Electric Motor Pump Set 30 HP,70 Metre Head,2280 LPM-01(One) No. and Jockey Pump Set 5 HP,70 Metre Head,300 LPM-01(One) No.; Contd/-

9

-

-

... More
Tech Flight,115HU,106SQN and 2SQN Loctions:- Diesel Engine Driven Pump Set 105 HP,88 Metre Head,2850 LPM-01(One) No.in each location, Electric Motor Pump Set 100 HP,88 Metre Head,2850 LPM-01(One) No.in each location and Jockey Pump Set 15 HP,88 Metre Head,180 LPM-01(One) No.in each location] Notes:- (i) Engine Oil,Coolant,Distilled Water required for Replacement/Topping up will be measured and paid seprately under respective Items of this BOQ. However the cost of all kinds of Filters (Lubricant Filter/Fuel Filter/Air Filter) are deemed to be included in the quoted rate. (ii) Overhauling of Self Starter and calibration of fuel injector system in the fuel injection system of diesel engine and Hose Pipe Set for replacement will be measured and paid seprately under respective Items of this BOQ.

-

-

-

... More
Supply Only distilled water,all as specified. . Note:- Distilled Water shall be supplied in sealed PET bottles of 1 Litres/2 Litres.

200

-

-

... More
Supply Only,glycol based antifreeze radiator coolant,all as specified. (Make: Castrol/Bosch/Valvoline) Note:- Coolant shall be supplied in sealed HDPE containers of 1 Litres/2 Litres/5 Litres.

50

-

-

... More
Supply Only,engine oil, viscosity Grade 20W-40,all as specified. (Make: Castrol/Bosch/Servo/Gulf) Note:- Engine Oil shall be supplied in sealed HDPE containers of 5 Litres/20 Litres.

254

-

-

... More
Calibrating fuel injector system to simulate closely the function of fuel injectors in the fuel injection system of diesel (compression-ignition) engine of 2 HP capacity Diesel Engine coupled Pump Set in order to comply with the higher injection pressures,including replacement of minor spares,repair and servicing of injector nozzles,complete all as specified and directed.

2

-

-

... More
Supply Only,hose pipe set for Diesel Engine Coupled Pump Set all as per OEM's specifications, complete all as specified.

4

-

-

... More
Overhauling of Self Starter 12 Volts of DG Set/Diesel Engine Pump Set by opening up,cleaning of parts, lubrication and replacement of defective parts including re-assembling all as required for smooth functioning of self starter including refixing in original position,testing and commissioning, complete all as specified and directed. Notes:- (i) Cost of minor spares such nuts,bolts,screws,washers, insulation sleeves, lugs,lubricants etc. required for maintenance shall be deemed to be included in the unit rate quoted. (ii) Spares required to be replaced shall be measured and paid separately under relevant items of this BOQ. (iii) Spares replaced shall be guaranteed for two years. (iv) Self starter shall be tested in presence of Engineer in Charge and the cost of testing shall be deemed to be included in the quoted rate.

4

-

-

... More
Supply Only,Clutch Assembly suitable for Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

2

-

-

... More
Supply Only,Bendix Pinion suitable for Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

2

-

-

... More
Supply Only,Solonoid Switch suitable for Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

2

-

-

... More
Supply Only,Carbon Brush suitable for Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

2

-

-

... More
Supply Only,Armature Field Coil suitable for Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

2

-

-

... More
Supply Only,GM Bush suitable for main shaft of Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

3

-

-

... More
Supply Only,Armature Coil suitable for main shaft of Self Starter 12 Volts of DG Set as per OEM's specifications,all as specified. [Make: LUCAS/TVS/VALEO]

3

-

-

... More
Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 100 Ah,suitable for DG Set including provision of brass terminal clamps for connection,complete all as specified and directed. [Model : Xpress (XP1000) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']

3

-

-

... More
Supply and Fix in repairs,maintenance free lead acid battery,12 Volts,capacity 150 Ah,suitable for DG Set including provision of brass terminal clamps for connection,complete all as specified and directed. [Model : Xpress (XP1500) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']

3

-

-

... More
Disconnection of existing Star Delta Starter of any capacity form all incoming and outgoing electrical connections,checking serviceability of each components viz. contactors,overload relay,single phase preventer,indicator lamps etc.,replacement of internal wirings with FRLSH PVC insulated multistranded copper conductor 6.00 Sqmm size and defective lugs,thimbles etc.,replacement of defective parts,through cleaning of Star Delta Starter both internally and externally, reassembling of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning, complete all as specified and directed. Note:- Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.

5

-

-

... More
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 12, AC-3 rating 12 Amps and AC-1 rating 30 Amps,auxillary contacts 1 NO/ 1 NC, complete all as specified. [Cat No.CS94108/CS94109 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

3

-

-

... More
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 25, AC-3 rating 25 Amps and AC-1 rating 45 Amps,complete all as specified. [Cat No.CS94110 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

3

-

-

... More
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 32, AC-3 rating 32 Amps and AC-1 rating 55 Amps,complete all as specified. [Cat No.CS94111 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

3

-

-

... More
Supply Only,Thermal Overload Relays,Type MN 2,suitable for MNX Contactor,relay range 24 - 40 Amps,complete all as specified. [Cat No.SS94145OOFO of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

3

-

-

... More
Supply Only,Electronic Timers Type ST 100,240 / 360 / 415V, 50Hz for 3 - 30 seconds, complete all as specified. [Cat No.ST80328OOOO of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

3

-

-

... More
Supply Only,single phase preventer,SPPR type SDz5, 380V (For MU-G30/40/50/75), with settable Time 'ON' Delay 30 Seconds-5 Minutes,complete all as specified. [Cat No.XM81807OOOO of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]

3

-

-

... More
Excavation of trenches of suitable size,dewatering of trenches,returning filling in after repair work,removing surplus soil including repair to break down of 100mm/150mm dia of CI/DI/MS water pipe line bursting,cracks,joint leakage etc. including cleaning/removal of damaged pipe pieces by gas cutting / manual cutting as per site requirement,inserting necessary specials such as short pieces of pipes (Not exceeding 300 mm in length) as per existing specifications, collars, mechanical joints,lead joints,flanged joints,push on rubber ring joints etc as required,including testing for leakages of joints,complete all as specified and directed. Note: - The quoted rate shall be deemed to inclusive of the following: (i) Earthwork and cutting of existing PCC Path/Hard Standing.However PCC for making good distrubed surface of PCC Path/Hard Standing will be measured and paid seperately. (ii) Pumping arrangement for dewatering of trenches during attending break down. (iii) Qualified tradesmen for attending break downs. (iv) All T&P, Materials and Labour as required. (v) Levelling and alignment of the pipeline. (vi) Restore the damaged portion of pipeline leakage free.

2

-

-

... More
Materials and Labour for,100mm bore MS ERW pipe, heavy grade, with all fittings,laid in trenches including wrapping of pipe with 4 mm thick corrosion resistant tape conforming to IS: 10221 specifications after preparation and priming surface with resin based synthetic primer,complete all as specified and directed. [Make:- For Pipe: TATA/Jindal/Surya/Prakash ; For CR Tape with primer :IWL 'Pypkote AW 4mm Tape' or equivalent of Make STP/Dr Fixit]

6

-

-

... More
Materials and Labour for,150mm bore MS ERW pipe, heavy grade, with all fittings,laid in trenches including wrapping of pipe with 4 mm thick corrosion resistant tape conforming to IS: 10221 specifications after preparation and priming surface with resin based synthetic primer,complete all as specified and directed. [Make:- For Pipe: TATA/Jindal/Surya/Prakash ; For CR Tape with primer :IWL 'Pypkote AW 4mm Tape' or equivalent of Make STP/Dr Fixit]

6

-

-

... More
Materials and Labour for,plain cement concrete (1:3:6) Type C1(using 20 mm graded aggregate) for making good cutting chase for pass through pipe ,etc.in existing plain cement concrete pavement/ hardstanding/aprons etc.,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,resilient seated, cast iron,flanged butterfly valve,size 65 mm, PN 1.0, Class 125, with stainless steel shaft, lever operated, ISI Marked (IS-13095:1991, Reaffirmed 2003),including provision of carbon steel nuts, bolts & washers, rubber gaskets etc., fixed to water mains, complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,resilient seated, cast iron,flanged butterfly valve,size 150 mm, PN 1.0, Class 125, with stainless steel shaft, lever operated, ISI Marked (IS-13095:1991, Reaffirmed 2003),including provision of carbon steel nuts, bolts & washers, rubber gaskets etc., fixed to water mains, complete all as specified and directed.

2

-

-

... More
Supply and Fix,63mm reinforced rubber lined (RRL) hose,15 Metres with SS Coupling & GI binding,Type - A, ISI Marked (IS:636),complete all as specified and directed.

8

-

-

... More
Supply and Fix,branch pipe gun metal 63mm,instantaneous inlet,male threaded outlet,15mm bore nozzle short,ISI Marked (IS:903),complete all as specified and directed

8

-

-

... More
Supply and Fix in repairs,hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard,complete all as specified and directed.

8

-

-

... More
Supply and Fix in repairs,150 mm size gun metal lift type foot valve,Type-1,ISI Marked (IS:4038),complete all as specified and directed.

4

-

-

... More
Supply,installation,testing and commissioning of,fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules including taking down existing control panel and removing from site,complete all as specified and directed. [Cat No. BFB6-X1F-C-S of Make L&T Electrical & Automation/Cat No FPA-1200 of Make Bosch Security Systems or equivalent Model of Make Honeywell]

1

-

-

... More
Supply and Fix in repairs,detectors complying with and type certified to EN - 45 addressable type multisensor detector with heat and smoke combination Photoelectric/Optical with base with self built intelligence as per IS: 11360, complete all as specified and directed. [Cat No. BFMTD-533X-S + BFUSB-501-6-S of Make L&T Electrical & Automation/Cat No FAP-OT-420 of Make Bosch Security Systems or equivalent Model of Make Honeywell]

35

-

-

... More
Supply and Fix in repairs,indoor type detectors complying with and type certified to EN-45 Addressable Type flame detector with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module), complete all as specified and directed. [Cat No.MTD 533X of Make L&T Electrical & Automation/Cat No FAH‑T 420 (KKW) of Make Bosch Security Systems or equivalent Model of Make Honeywell]

4

-

-

... More
Supply and Fix in repairs,addressable manual call point resettable type,complete all as specified and directed. [Cat No. BFMCP545X-2R-S of Make L&T Electrical & Automation/Cat No FMC-210-DM-G-R of Make Bosch Security Systems or equivalent Model of Make Honeywell]

20

-

-

... More
Supply and Fix in repairs,Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB,1500 mtrs range,complete all as specified and directed. [Cat No. BX-SOL of Make L&T Electrical & Automation/Cat No FNM-420-A of Make Bosch Security Systems or equivalent Model of Make Honeywell]

4

-

-

... More
Comprenesive maintenance,repair and upgradation of software including renewal/replacement of defective parts of all existing fire detection system complete consisting of Addressable Fire Control Panel, Remote Terminal Unit Panels,Smoke/Heat Detectors, Response Indicators, Sounders/Sirens, Manual Call Points, Amlifier, Loud Speaker, Loop Isolator, Zone Monitor Module, Modem etc. to make 100 % serviceability of the complete system including checking of Flame Detectors,Smoke Detectors,cleaning of heavy greasy deposit if any,checking the connection of back up power batteries,checking the alarm function of control panel and checking the operation of indicating equipments by triggering devices in each Zone,through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE,complete all as specified and directed. [OEM(s):- L&T Electrical & Automation/Bosch Security Systems/Godrej Security Solutions/ Honeywell] Notes:- (i) Defective components for replacement will be measured and paid for separately under relevant items of this BOQ. (ii) Contractor or his accredited representative shall visit the installations minimum once in a celender month during currency of the contract to access the serviceability of the FACP (s) alongwith its connected components,obtain serviceability certificate from the User Unit and deposit the same to the Engineer in Charge monthwise. (iii) Repair and maintenance of the Fire Alarm System shall be done through OEMs or through the authorized service provider of the OEMs or any other agency dealing with the installation and maintenance of FIRE ALARM REMOTE COMMUNICATION SYSTEMS (RTU) having requisite experience in the relevant field as approved by the Accepting Officer.

10

-

-

... More
Taking down carefully existing multisensor detectors with heat and smoke combination photoelectric,cleaning throughly,checking for faults if any and refixing in the original position through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE including testing and commissioning,complete all as specified and directed. [OEM(s):- L&T Electrical & Automation/Bosch Security Systems/Godrej Security Solutions/ Honeywell]

1200

-

-

... More
Supply Only,Sealed Maintenance Free Valve Regulated Lead Acid (VRLA) Battery,12 Volts, capacity 7 Ah,suitable for Fire Alarm Control Panels all as per OEM's specifications,complete all as specified. [Model : Chloride Safe Power (CS 7-12) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']

7

-

-

... More
Supply Only,Sealed Maintenance Free Valve Regulated Lead Acid (VRLA) Battery (Sealed Dry Battery),12 Volts,capacity 12 Ah,suitable for Fire Alarm Control Panels all as per OEM's specifications,complete all as specified. [Model : Chloride Safe Power (EP12-12) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']

6

-

-

... More
Periodical Overhauling,through cleaning, Lubrication/Greasing/Oiling of Entire Lift(s) [‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors, installed in G+2 Building and ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors,installed in G+2 ATC Building] including the Hoist Way Components, Guide Rails,Car Counters,Weights,Pulleys,Gear Box,changing of gear oil etc as required for 100% serviceability of the lifts,through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE including testing and commissioning,complete all as specefied and as directed. Notes:- (i) Spare Parts for replacement will be measured and paid separately under relevant items of this BOQ. (ii) Contractor or his accredited representative shall visit the installations minimum once in a celender month during currency of the contract to access the serviceability of the Lift (s),obtain serviceability certificate from the User Unit and deposit the same to the Engineer in Charge monthwise. (iii) Repair and maintenance of the Lift(s) shall be done through OEMs or through the authorized service provider of the OEMs or any other agency dealing with the installation and maintenance of Lifts,having requisite experience in the relevant field as approved by the Accepting Officer.

5

-

-

... More
Supply and Fix in repairs,Mother Board in elevator,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Power Supply Card,220 Volts,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Transformer 220V/9V suitable for ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors,installed in G+2 ATC Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Transformer 440V/135V,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Power Supply Card,110V suitable for ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors,installed in G+2 ATC Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,UP/DN & IL Relay Card suitable for ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors,installed in G+2 ATC Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Car Operative Button Set with all accessories (For Lift Car & Floor Button) suitable for ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors,installed in G+2 ATC Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs, Landing Push button Set,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Gate Relay Assembly Set,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Elevator Door Detector (Infrared sensor) of capacity 188/988 A-AC 220 Volt in both side of door with one No power controller of capacity DC 24 VIA or AC 120 VIA suitable for ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers,with power operated doors,installed in G+2 ATC Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Car Gate Contact Lock,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Encoder/Main drive,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,ARD Card,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,Lift Main Drive of capacity 18.5KW, 400 Volt, 3 phase. Input: AC 3 Phase 380-480 Vpolt, 50/60Hz,44A and Output: AC 3 Phase 0-480 Volt, 0-200Hz 39A,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs, Door Drive of cap 0.4 KW, 220 Volt, single phase. Input: AC 1 Phase, 200-240 Volt, 50/60 Hz, 5.8 A and Output: AC 1 Phase 0-220 Volt, 0-99 Hz, 2.2 A,suitable for ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors,installed in G+2 Building all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply & fixing in replacement of Overspeed governor Limit switch all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply & fixing in replacement of car door lock contact male all as per OEM's specifications,complete all as specified and directed.

1

-

-

... More
Supply & fixing in replacement of Limit switch complete all as per OEM's specifications,complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,Sealed Maintenance Free Valve Regulated Lead Acid (VRLA) Battery (Sealed Dry Battery),12 Volts,capacity 18 Ah,suitable for Lifts all as per OEM's specifications,complete all as specified. [Model : Power Safe Plus Dry Battery (EP-18-12) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco'] [OEMs:- ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms,with power operated doors, installed in G+2 Building and ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors,installed in G+2 ATC Building]

5

-

-

... More
Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.