Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 43,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_240060_1Bid Award Id
ViewTender No
C/8830/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
143
-
-
... More
Returning, filling in, including spreading, levelling, as in soft/loose soil complete all as specified and directed.
89
-
-
... More
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
54
-
-
... More
M & L for Hardcore of broken/crushed stones of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
49
-
-
... More
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and directed.
12.35
-
-
... More
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and directed.
37.5
-
-
... More
M&L for Brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
19
-
-
... More
M & L for Plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in surface channel, drains etc complete all as specified and directed.
13
-
-
... More
Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed. (Inner girth only be measured)
43
-
-
... More
All as per item No 12 above but add or deduct for each 25mm girth or part thereof over or under 30cm
36
-
-
... More
M&L for Brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
18
-
-
... More
M & L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
18
-
-
... More
M & L for Reinforced Cement Concrete 1:2:4, type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and directed.
1.75
-
-
... More
M & L for Reinforced Cement Concrete 1:2:4, type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc complete all as specified and directed.
1.75
-
-
... More
M & L for Reinforced Cement Concrete 1:2:4, type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and directed.
1.75
-
-
... More
M & L for Reinforced Cement Concrete 1:2:4, type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pliiars, post and struts etc complete all as specified and directed.
1.5
-
-
... More
M & L for use & waste Form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and directed.
5
-
-
... More
M & L for use & waste Form work to soffits and sides of roof slabs for flat rough finished surfaces of concrete complete all as specified and directed.
15
-
-
... More
M & L for use & waste Form work to soffits and sides lintel beam for flat rough finished surfaces of concrete complete all as specified and directed.
10
-
-
... More
M & L for use & waste Form work to sides of columns, flat rough finished surfaces of concrete complete all as specified and directed.
12
-
-
... More
S & F TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
350
-
-
... More
S & F TMT steel bars 6 to 8mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
75
-
-
... More
M & L for Hardcore of broken bricks aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
5
-
-
... More
M & L for Sand filling under floor with clean dry sand complete all as specified and directed.
(Note: Thickness after punning down shall be measured for payment)
4
-
-
... More
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
12
-
-
... More
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
15
-
-
... More
M & L for glazed ceramic, coloured tiles 7 to 8 mm thick, area of each tiles not less than 0.06 Sqm as in vertical surfaces, skirting/dado including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
45
-
-
... More
M & L for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
40
-
-
... More
M & L for rendering 15 mm thick in two layer (10mm + 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with water proofing compound at top 5mm thick layer by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
30
-
-
... More
M & L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
16
-
-
... More
"Supply only" liquid water proofing compound complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
2
-
-
... More
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
60
-
-
... More
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
16
-
-
... More
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in floors fair and even without using extra cement to receive top layers complete all as specified and directed.
16
-
-
... More
S & F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
1.25
-
-
... More
S & F 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
1
-
-
... More
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
15
-
-
... More
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
4.5
-
-
... More
S & F 100 mm size, butt hinges, stainless steel including cadmium coated screws complete all as specified and directed.
9
-
-
... More
S & F 100 mm size, Aluminium handles, cast type, anodised complete all as specified and directed.
6
-
-
... More
S & F 100 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
6
-
-
... More
M & L Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick plastering in cement mortar 1:4 finished even & smooth. (c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming to IS-3384 (f) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (g) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
16
-
-
... More
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and directed.
206
-
-
... More
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and directed.
10
-
-
... More
S & F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) (bearing ISI marked), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
1
-
-
... More
S & F 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
1
-
-
... More
S & F vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed.
1
-
-
... More
S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
1
-
-
... More
S & F vitreous China wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed. (Make : Parryware, Cat No C0406 or equivelant of make as specified in list of manufacturer)
1
-
-
... More
S & F Vitreous China urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. (Make: Parryware Cat No. C0575 or equivelant of make Hindware/Cera)
1
-
-
... More
S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
1
-
-
... More
S & F 15 mm bore, Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with capastan head, screwed both ends for iron pipe or for unions complete all as specified and directed.
59
-
-
... More
S & F 15 mm bore, bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
4
-
-
... More
S & F 600mm long towel rail of PTMT fixed with and including chromium plated brass screws into wooden rawl plug/PVC sleeves etc complete as directed. ( Minimum wt. 190gms)
2
-
-
... More
S & F swival shower of PTMT 15mm bore (minimum weight 40 gms) including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and directed.
2
-
-
... More
S & F 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints fixed to wall using MS holder bat for rain water, etc complete all as specified and directed.
23
-
-
... More
S & F 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints fixed to wall using MS holder bat for rain water, etc complete all as specified and directed.
10
-
-
... More
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
8
-
-
... More
S & F 110 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and directed.
2
-
-
... More
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
2
-
-
... More
S & F 110 mm bore, PVC (SWR) vent cowl fixed with solvent cement complete all as specified and directed.
2
-
-
... More
S & F 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
3
-
-
... More
M&L for 15 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipe or for union including taking down old unserviceable valve complete all as specified and directed.
4
-
-
... More
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
60
-
-
... More
S & F Pre-Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and directed. (Colour of ridge shall be same colour as that of sheet used for roof)
2
-
-
... More
S & F mild steel work in tubular trusses, post fixed independently, purlins using ERW or butt welded tubes conforming to IS 1161-1998, grade YSt-240, including cutting, welding complete all as specified and directed.
700
-
-
... More
S & F Rolled mild steel framed work using Joist, channel, angle, or tee sections, for water tank stagging. Mild steel conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
323
-
-
... More
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
44
-
-
... More
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) (bearing ISI marked), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
1
-
-
... More
S & F 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
1
-
-
... More
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in sub base of floor/hardstanding in sutable gradient, finished the surfaces fair and even without using extra cement complete all as specified and directed.
490
-
-
... More
M & L for precast machine pressed interlocking paver block any shaped and size conforming to IS- 15658-2006, 60mm thick, M-35 grade concrete with grey cement and no pigment, set and jointed in dry sand including providing 60mm thick dry sand filling below paver blocks complete all as directed
400
-
-
... More
M & L for best quality coloured cement concrete chequred tiles of size 40cm x 40cm x 25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
90
-
-
... More
S & F LED garden/lawn light fittings (TULIP OF BAJAJ MAKE) 9 Watt withLED bollard with opal acrylic diffuser and IP 65 protection including fixing accessories like nuts, bolts etc for holding the light fitting, grouting bollard fitting into PCC block, providing 50mm dia PVC conduit/bend inside concrete bolck for passing cables, suitable connector for incomimg and outgoing of UG cable passing through each fitting, providing and connecting up with 2.5 Sqmm multistranded aluminium conductor cables not less than 3 metre of length etc and testing complete including taking down old light fitting carefully all as specified and directed. (Make : BAJAJ Product Code No 111284 or equivlant model of Wipro/Philips/CG/Surya Rashni as approved). Note : - PCC block shall be measured and paid separately under respective item under this schedule.
14
-
-
... More
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in PCC block, foundation, filling, coping etc, rendering external surfaces with 5mm thick in CM 1:3, finshed smooth without using extra cement including necessary form work complete all as specified and directed.
1
-
-
... More
Supply and fix time switches digital type 250 Volt single phase, contactor rating 20A/TP, MCB rating 20A/SPN fitted inside steel enclosure including connecting items complete all as directed. Make : - Havells or equivalent of L&T/Legrand/C&S as approved by GE.
2
-
-
... More
Supply and fix weather proof flat twin core multistranded aluminium cable, 2.5 sqmm
42
-
-
... More
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 2 core, nominal cross sectional area of conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands,aluminium lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. (Note: Excvation and earth work shall be measured and paid seperately)
180
-
-
... More
Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site as specified and directed. (Note : Earth work shall be measured and paid separately under relevant items of this schedule)
380
-
-
... More
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3.5 core, nominal cross sectional area of conductor 400 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands,aluminium lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. (Note: Excvation and earth work shall be measured and paid seperately)
34
-
-
... More
Laying only serviceable Under ground cable of size upto 35 Sqmm, 3.5 Core including providing new cable gland, aluminium lugs etc suit to cable size complete as directed. Note:- Old serviceable UG cable retrieved under item No 82 shall be used.
120
-
-
... More
Laying only serviceable Under ground cable of size 400 Sqmm, 3.5 Core including providing new cable gland, aluminium lugs etc suit to cable size complete as directed. Note:- Old serviceable UG cable retrieved under item No 82 shall be used.
260
-
-
... More
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
2160
-
-
... More
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.
(Note: Thickness after punning down shall be measured for payment)
21
-
-
... More
M & L for 80 mm dia, Galvanised steel tubing, light grade with all fittings for protection of cable laid on road crossing, drain crossing, laid in trenches/floor/road/wall complete all as specified and directed.
8
-
-
... More
Drilling/boring hole horizontally below the road for pipe crossing upto 80mm bore, using trenchless technology complete all as directed. (Note: Cost of accessories required for boring hole deemed to be included in the quoted rate).
8
-
-
... More
Supply, jointing and testing cold shrinkable outdoor cable joint kit suitable for XLPE/PVC insulated cable 1100 Volts grade of size 400 Sqmm 3.5 Core complete all as specified and directed.
2
-
-
... More
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
30
-
-
... More
All as per item No. 91 above but wiring with cables of size 2.5 sqmm & cables of size 1.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board complete all as specified and directed.
4
-
-
... More
S & F switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and as directed.
30
-
-
... More
S & F Switch socket combination, 2 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
4
-
-
... More
S & F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body including suitable PVC block/box complete all as specified and directed.
30
-
-
... More
Fixing only water cooler electric driven, having storage capacity 80 Ltr and nominal cooling capacity 40 Ltr per hour. Note :- Water cooler any type, make and capacity shall be issued under Sch'B' as free for fixing.
4
-
-
... More
Fixing only Voltage stabilizer 1.0 KVA capacity for automatic operation, single phase naturally air cooled indoor type and designed for output variation between 170V to 250 V with out put voltage stabilized at 230 V with accuracy of plus/minus 2.5%. Note :- Volatage Stabilizer any type, make and capacity shall be issued under Sch'B' as free for fixing.
4
-
-
... More
Cutting hole/opening through wall for providing 300mm sweep exhaust fan and making good the disturbed surfaces using cement mortar 1:4 finished the surfaces to match with existing complete all as directed.
30
-
-
... More
Fixing only exhaust fan, 300mm sweep, AC single phase 230/240 Volt. Note :- Exhaust fan with louvoure any make shall be issued under Sch'B' as free for fixing.
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements