Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 95 Sq mm, 3 ½ core, with and including relaying old serviceable UG cable of any size/ type on trenches/ wall/ roof etc. after necessary repair/ rerouting works complete all as specified and directed by Engr-in-charge. Note :- i) In relaying of cable old serviceable bricks, GI pipes obtained during taking out existing cable shall be reused. If required new bricks, sand, GI pipe shall also be use. New brick and sand to be measured and paid under relavant item seperately.

150

-

-

... More
Taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 70 Sq mm, 3 ½ core, with and including relaying old serviceable UG cable of any size/ type on trenches/ wall/ roof etc. after necessary repair/ rerouting works complete all as specified and directed by Engr-in-charge. Note :- i) In relaying of cable old serviceable bricks, GI pipes obtained during taking out existing cable shall be reused. If required new bricks, sand, GI pipe shall also be use. New brick and sand to be measured and paid under relavant item seperately.

100

-

-

... More
Taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 50 Sq mm, 3 ½ core, with and including relaying old serviceable UG cable of any size/ type on trenches/ wall/ roof etc. after necessary repair/ rerouting works complete all as specified and directed by Engr-in-charge. Note :- i) In relaying of cable old serviceable bricks, GI pipes obtained during taking out existing cable shall be reused. If required new bricks, sand, GI pipe shall also be use. New brick and sand to be measured and paid under relavant item seperately.

100

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final.

354

-

-

... More
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in any kind of soil complete all as specified and as directed.

193.75

-

-

... More
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.

160.25

-

-

... More
Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed.

60

-

-

... More
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).

127.44

-

-

... More
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.

6.5

-

-

... More
Re-laying only old Brick in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. here-in-before), complete all as directed.

7.5

-

-

... More
M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site.

40

-

-

... More
Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and as directed.

80

-

-

... More
S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc. with and including all connected fittings , complete all as specified and as directed.

30

-

-

... More
S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc. with and including all connected fittings , complete all as specified and as directed.

30

-

-

... More
S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc.,with and including all connected fittings , complete all as specified and as directed.

20

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 300 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. with and including taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, , complete all as directed.complete all as specified and as directed.

100

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor185 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. with and including taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, , complete all as directed.complete all as specified and as directed.

200

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. with and including taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, , complete all as directed.complete all as specified and as directed.

150

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. with and including taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, , complete all as directed.complete all as specified and as directed.

350

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. with and including taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, , complete all as directed.complete all as specified and as directed.

300

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with and including taking out existing, PVC/XLPE insulated, PVC sheathed, armoured U/G cables, , complete all as directed.complete all as specified and as directed.

200

-

-

... More
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts of over all Miniumum size 1200 mm (W) x 1000 mm (H) x 500 mm (D) outdoor type, CPRI type tested having certification of IEC-61439 , factory made free standing, floor mounting, dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar made of copper ETP grade suitable for 500 Amp (size of copper strip should not be less than 30x5 mm for each phase and neutral) pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:5:10, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories

1

-

-

... More
BUS BAR (i) Copper ETP grade suitable for 300 Amp bus bar, , supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos. INDICATING DEVICES:- (i) Digital Voltmeter (96mmx96mm) 0-500 Volt with selector switch of 10Amps -1No. (ii) Indoor tape insulated,ring type,BPL (Bar Primary Low Tension) Current Transformers,Ratio 200/5A,Accuracy Class 1.0,Rated Burden 10 VA,Make AE/BCH/ L&T - 03 (Three) Nos. (iii) LED Indicator 16 mm with power consumption 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC (RYB) all as per Model No SIL of Make “L&T” or equivalent Model of Make BCH/ AE - 01 Set (Set of Three) (V) Digital Ammeter 0 to 400 Amps, square type (96mmx96mm) - 01 Nos.(vi) Voltmeter Selector switch (6A) 3 position with 'OFF' - 01 No. (vii) Ammeter Selector switch (6A) 3 position with 'OFF' - 01 Nos INCOMING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 250 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable short-circuit settings: 6 - 10 x In Make “L&T”/Siemens/ Legrand / ABB.] - 01 (One) Nos.

-

-

-

... More
OUTGOING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 125 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In.Make “L&T” / Siemens/ Legrand / ABB.] - 02 (Two) Nos. (ii) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In. Make “L&T” / Siemens/ Legrand / ABB.] - 02 (Two) Nos. Note:- (i) All MCCB/MCB should be of Make : L&T/ Legrand /Schnider/Seimens. Note:- (i) All MCCB/MCB should be of Make : L&T/ Legrand /Schnider/Seimens/ABB. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel.(iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel.(iv) Rotary handle to be provided for all MCCB for control and operation of MCCB.(vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s

-

-

-

... More
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts of over all Miniumum size 1000 mm (W) x 800 mm (H) x 500 mm (D) outdoor type, CPRI type tested having certification of IEC-61439 , factory made free standing, floor mounting, dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar made of copper ETP grade suitable for 300 Amp (size of copper strip should not be less than 30x5 mm for each phase and neutral) pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:5:10, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories

1

-

-

... More
BUS BAR (i) Copper ETP grade suitable for 300 Amp bus bar, , supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos. INDICATING DEVICES:- (i) Digital Voltmeter (96mmx96mm) 0-500 Volt with selector switch of 10Amps -1No. (ii) Indoor tape insulated,ring type,BPL (Bar Primary Low Tension) Current Transformers,Ratio 200/5A,Accuracy Class 1.0,Rated Burden 10 VA,Make AE/BCH/ L&T - 03 (Three) Nos. (iii) LED Indicator 16 mm with power consumption 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC (RYB) all as per Model No SIL of Make “L&T” or equivalent Model of Make BCH/ AE - 01 Set (Set of Three) (iv) Miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA,C-curve,6 Amps [Cat No. BB10060C of Make L&T or equivalent Model of Make Legrand/ Hager/Seimens /GE/Schneider/ABB] - 03 (Three) Nos (V) Digital Ammeter 0 to 400 Amps, square type (96mmx96mm) - 01 Nos.(vi) Voltmeter Selector switch (6A) 3 position with 'OFF' - 01 No. (vii) Ammeter Selector switch (6A) 3 position with 'OFF' - 01 Nos INCOMING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable short-circuit settings: 6 - 10 x In Make “L&T”/Siemens/ Legrand / ABB.] - 01 (One) Nos.

-

-

-

... More
OUTGOING:- (i) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In.Make “L&T” / Siemens/ Legrand / ABB.] - 03 (Three) Nos. (ii) Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In.Make “L&T” / Siemens/ Legrand / ABB.] - 01 (One) Nos. .Note:- (i) All MCCB/MCB should be of Make : L&T/ Legrand /Schnider/Seimens/ABB. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel.(iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel.(iv) Rotary handle to be provided for all MCCB for control and operation of MCCB.(vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s

-

-

-

... More
Disconnecting incoming and outgoing connections of existing indoor Type LT Feeder Pillar Box, AC 415 V, 50 Hz, 3 Phase,demolition of existing damaged PCC foundation block,shifting of the Feeder Pillar Box to a new location exc.15 M but not exc. 30 M, excavation of post holes in any type of soil for foundation block including providing PCC (1:2:4) Type B1 foundation block in legs of feeder pillar box,painting old painted steel surfaces both internally and externally by applying two coats of synthetic enamel paint (ordinary tint) by spray painting process after preparation of surface, reconnection of all incoming and outgoing electrical connections after re-installation in new position,testing and commissioning,complete all as specified and directed.

3

-

-

... More
Disconnecting incoming and outgoing connections of existing LT Feeder Pillar Box, AC 415 V, 50 Hz, 3 Phase,checking serviceability of each components viz. MCB's, MCCB's, indicator lights, display meters, etc.,replacement of burnt out internal wirings with with suitable size FRLSH PVC insulated multistranded copper conductor wires,replacement of defective lugs,thimbles etc.,replacement of non hygroscopic fibres and brass screws for mounting of busbars,repairs/welding/replacement of minor damaged portion of frame,canopy,compartments,shutters,back covers,legs etc.,repairs/ easining the locking arrangements along with door hinges, through cleaning of feeder pillar box both internally and externally, providing PCC (1:2:4) Type B1 foundation block in legs of feeder pillar box after demolition of existing damaged PCC foundation block, painting old painted steel surfaces both internally and externally by applying two coats of synthetic enamel paint (ordinary tint) by spray painting process after preparation of surface, re-interconnection of parts,including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning,complete all as specified and directed. Notes:- (i), MCB(s),MCCB(s),voltmeter,Display Meter(s),Indicator(s) etc for replacement will be measured and paid seperately under relevant items in this BOQ as supply and fix. (ii) New steel surfaces shall be applied a coat of red oxide zinc chrome primer.

20

-

-

... More
Supply and fixing 3 phase digital voltmeter flush mounting 96 X 96 mm of input voltage measurement range 50-520 VAC(P-P) , 5A,accuracy class 0.5 for LT panel board, with proper caliberation complete all as specified and directed by Engr-in-Charge including taking down unserviceable complete all as specified & directed.

8

-

-

... More
Supply and Fix in repairs, 3 Phase LED digital ammeter, Accuracy Class 0.5, Aux supply 80-300 VAC, CT secondary site selectable 1A / 5A, flush mounting 96 x 96 mm, with inbuilt selector switch, complete all as specified and directed.

8

-

-

... More
M&L lettering made of radium reflective sheet (encapsulated lens type), height exc. 50mm but not exc. 100mm, cut to size and pasted on mild steel plate with adhesive as per manufacturer's instruction complete all as specified and as directed.

80

-

-

... More
M&L Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on Insulators and Steel Frame Single Break Insulator suitable for Out door Vertical Mounted complete with Manual Operating Mechanism made and operation from GL including 25mm bore GI pipe heavy duty and handle Arching Horns and Terminal Connectors for ACSR Conductors conforming to IS-1818/72 and 9921/85 with 3 Isolator Per Pole of Capacity 200 Amp, 11 KV Operation including necessary Adjustment and making Holes on Mild Steel Angle and Testing complete all as specified and as directed. Make : JAIPURIA / ATLAS.

3

-

-

... More
M&L Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on Insulators and Steel Frame Single Break Insulator suitable for Out door Vertical Mounted complete with Manual Operating Mechanism made and operation from GL including 25mm bore GI pipe heavy duty and handle Arching Horns and Terminal Connectors for ACSR Conductors conforming to IS-1818/72 and 9921/85 with 3 Isolator Per Pole of Capacity 400 Amp, 11 KV Operation including necessary Adjustment and making Holes on Mild Steel Angle and Testing complete all as specified and as directed. Make : JAIPURIA / ATLAS.

3

-

-

... More
M & L for PCC M-10 (Nominal mix) using 40mm graded stone aggregate as in foundation, filling and mass concrete for foundation concrete in poles/stays.with and including demolition of cement concrete in any description complete all as specified and directed

0.5

-

-

... More
M & L for PCC M-15 (Nominal mix) using 20mm graded stone aggregate for coping as in benching incl weathering slightly rounded, chamfered angles and finishing exposed surfaces even and smooth incl necessary formwork with and including demolition of cement concrete in any description complete all as specified and directed

2

-

-

... More
M&L Drop out fuse, Triple Pole, mounted on Insulators and Steel Frame suitable for Out door Vertical Mounted complete and Terminal Connectors for ACSR Conductors conforming to IS-1818/72 and 9921/85 with 2 Isolator Per Pole of Capacity 200 Amp, 11 KV Operation including necessary Adjustment and making Holes on Mild Steel Angle and Testing complete all as specified and as directed. Make : JAIPURIA / ATLAS.

3

-

-

... More
Materials and Labour for provision of concrete earthing pit as shown on electrical plate No 3 of SSR Part –I (2009), in PCC (1:3:6) Type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, including demolition of existing damaged earthing pit and including necessary earthwork in any type of soil, complete all as specified and directed.

20

-

-

... More
Supply and Fix in repair,aluminium lugs,long barrel suitable for 1100 Volts grade cables with stranded conductor of size 400 Sq mm,complete all as specified and directed.

25

-

-

... More
All as per above item no-42 but here in before for cable size 300 sqmm all as specified and directed.

25

-

-

... More
All as per above item no-42 but here in before for cable size 240 sqmm all as specified and directed.

25

-

-

... More
All as per above item no-42 but here in before for cable size 185 sqmm all as specified and directed.

50

-

-

... More
All as per above item no-42 but here in before for cable size 150 sqmm all as specified and directed.

50

-

-

... More
All as per above item no-42 but here in before for cable size 120 sqmm all as specified and directed.

50

-

-

... More
All as per above item no-42 but here in before for cable size 95 sqmm all as specified and directed.

50

-

-

... More
All as per above item no-42 but here in before for cable size 70 sqmm all as specified and directed.

80

-

-

... More
All as per above item no-42 but here in before for cable size 50 sqmm all as specified and directed.

80

-

-

... More
All as per above item no-42 but here in before for cable size 35 sqmm all as specified and directed.

80

-

-

... More
All as per above item no-42 but here in before for cable size 25 sqmm all as specified and directed.

80

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 25 Sq mm, 4core, complete all as specified and directed.

25

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 35 Sq mm, 3 ½ core, complete all as specified and directed.

25

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 50 Sq mm, 3 ½ core, complete all as specified and directed.

25

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 70 Sq mm, 3 ½ core, complete all as specified and directed.

25

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 95 Sq mm, 3 ½ core, complete all as specified and directed.

25

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 120 Sq mm, 3 ½ core, complete all as specified and directed.

25

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 150 Sq mm, 3 ½ core, complete all as specified and directed.

15

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 240 Sq mm, 3 ½ core, complete all as specified and directed.

15

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 300 Sq mm, 3 ½ core, complete all as specified and directed.

10

-

-

... More
Supply and Fix in repair,single compression,brass cable glands suitable for 1100 Volts grade cables with stranded conductor of size 400 Sq mm, 3 ½ core, complete all as specified and directed. [Make for Serial Item No. 68 to 87:- Dowell's/Dollars/UML/Cembre]

10

-

-

... More
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-22/ SP-31 (8.5/9.00 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.

250

-

-

... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 25 sq. mm to 50 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0130 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]

10

-

-

... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 70 sq. mm to 120 sq. mm, complete all as specified and directed. Make M-Seal / Birla - 3M / Raychem/ Cabseal / Denson

10

-

-

... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 150 sq. mm to 185 sq. mm, complete all as specified and directed. Make M-Seal / Birla - 3M / Raychem/ Cabseal / Denson

10

-

-

... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 240 sq. mm to 300 sq. mm, complete all as specified and directed. Make M-Seal / Birla - 3M / Raychem/ Cabseal / Denson

5

-

-

... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 300sq. mm to 400 sq. mm, complete all as specified and directed. Make M-Seal / Birla - 3M / Raychem/ Cabseal / Denson

1

-

-

... More
Materials and Labour for cable connector of length 0.5 m, made out of 50sqmm multistranded copper conductr single core. PVC inner sheathed unarmoured cable including copper lugs, copper nut bolts etc., complete all as specified and directed.

30

-

-

... More
S&F 4 way Cable connector,with and including connected fittings complete all as specified and directed.

50

-

-

... More
Supply and Fix in repairs, On Load Change Over Switch in sheet steel enclosure, Four Pole, Current Rating 400 Amps, Four pole ,415 Volts conforming to IS 13947 (Part 3)-1993; IEC: 60947-3, complete all as specified and directed. Make Siemens/ Legrand / ABB.]

2

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 400 Amps and 50 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 400 Amps and 50 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 250 Amps and 50 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 250 Amps and 50 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 200 Amps and 50 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 200 Amps and 50 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 125 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 125 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

2

-

-

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

2

-

-

... More
S&F for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil/stone ,disposal of soil , providing alternate layers of charcoal and common salt, refilling of pit with agriculture soil, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion,including taking out old u/s complete all as specified and directed. (Note: (i) Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) (ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit.

4

-

-

... More
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction of inspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately (Note : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with 4 x Bags of bentonite clay of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986. (vii) The cost of Copper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.

4

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 32 X 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.

5

-

-

... More
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies for period of six month for DG SYNCHRONIZATION load sharing panel with ACB and ATS panel complete with checking and repairing all as per OEM's recommendations and including replacement of unserviceable parts as required and including installing to its existing foundation, commissioning, connecting up and testing complete as specified and directed and with and including the fault as following (A) FAULT FINDING DG SYNCHRONIZATION LOAD SHARING PANEL. 1. Metering and Test Instruments including PLC input output module. 2. All Generators. 3. Self-Excited Generators. Automatic Voltage Regulator is powered from the Generator Output. 4. Separately Excited Generators Automatic Voltage Regulator is powered from the Permanent Magnet Generator. 5. Parallel Operation for All Generators DG-1,DG-2 6. All aux. Contactor and relay. 7. Phase angle and power-factor transducer 8. Reverse current relay for each DG. 9. ACB.(with shunt close charging motor with Under-voltage relay) 10.Motorized POT for the master DG running in Manual Parallel and Auto Parallel modes. 11.PLC 12.Synchroscope for Parallel mode. 13.Up/Down joystick for frequency Up/Down in manual parallel and Auto Parallel Modes. Under voltage relay for stabilizing the voltage below set voltage. To be kept along with the DG output each (B) SERVICING OF AIR CIRCUIT BREAKER 1. After the initial inspection, cleaning of ACB component. 2. Main contact that control current flow require meticulous Cleaning to remove any built up dirt moisture using specialized silver cleaner materials with cloth. Proper lubrication . The opening mechanism made up of the device and chassis component thoroughly cleaned and proper lubrication of the ACB. NOTE- Panel Switcgear and any control component shall be measured & paid separately under respective items of this schedule However any spare part which is technically required for full fucntional of panels the same deemed to be inclusive in quoted rates. Bidders are advised to visit the site before quoting the same.

3

-

-

... More
Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.