Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Dec 2024
Closing Date9 Jan 2025
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling ACSR Conductor of any Size including Line Spacers of OH Electric Lines from Electric Poles, complete all as specified and as directed.

1

-

-

... More
Dismantling Unserviceable/ Rusted GI Earth Wire, Cradles Guards of any Size from Electric Poles of any Size and capacity, complete all as specified and as directed.

0.2

-

-

... More
Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be Dismantled at Ground Level and Disturbed Ground will Made Good as directed for which Earth Work, Demolition Cement Concrete, etc. will not be Measured separately for Payment.

2

-

-

... More
Dismantling Switch Air Break Gang and Steel Frame of any description, complete all as specified and as directed.

2

-

-

... More
Dismantling HT Lightening Arrester complete with all Fittings of any description, complete all as specified and as directed.

2

-

-

... More
Dismantling Danger Notice Plate of any description, complete all as specified and as directed.

18

-

-

... More
Disconnecting & Taking down/ out Unserviceable LT Cable of Size 10/ 16 Sqmm, 2/3½/4 Core and any description from Trenches, Floors, Walls, GI Pipes, etc. including Serviceable (if any) Cables, Cable Joints, Bricks/ Cable Protection Cover, etc. Keep in Safe Custody for Re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.

330

-

-

... More
Disconnecting & Taking down/ out Unserviceable LT Cable of Size 25/ 35/ 50 Sqmm, 3½/4 Core and any description from Trenches, Floors, Walls, GI Pipes, etc. including Serviceable (if any) Cables, Cable Joints, Bricks/ Cable Protection Cover, etc. Keep in Safe Custody for Re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.

130

-

-

... More
Disconnecting & Taking down/ out Unserviceable LT Cable of Size 70/ 95 Sqmm, 3½/4 Core and any description from Trenches, Floors, Walls, GI Pipes, etc. including Serviceable (if any) Cables, Cable Joints, Bricks/ Cable Protection Cover, etc. Keep in Safe Custody for Re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.

50

-

-

... More
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Mains, Cables, Electric Poles, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.

130.68

-

-

... More
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Poles, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.

0.16

-

-

... More
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in layers not exc. 25 Cm, Providing Heaps along the Route of the Water Mains, Cable Lines, etc. with surplus Soil in Soft/Loose Soil, complete all as specified and as directed.

73.1

-

-

... More
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.

57.74

-

-

... More
M&L Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. (Maximum 10.00 Metre in Width) by Manually or by any other means suitable for Passing GI Tubing upto 100mm bore (dia), complete all as specified and as directed.

20

-

-

... More
M&L Cutting on Existing Road not exc. 1.00 Metre in Depth and not exc. 0.50 Metre in Width including Making Good the Same with Cement Concrete 1:3:6 (40mm graded stone aggregates) not exc. 150mm thick on Top Layer after necessary Returning, Filling in, Well Ramming and Levelling in Layers to match the Existing Surface Levels after Filling of Cement Concrete, complete all as specified and as directed. NOTE : Cement Concrete will be Measured & Paid for separately under appropriate Item.

5

-

-

... More
M&L Cement Concrete 1:4:8 (40mm graded stone aggregates) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deem to be included in the Quoted Unit Rate.

0.25

-

-

... More
M&L Cement Concrete 1:3:6 (40mm graded stone aggregates) in Foundation of Stay Assembly, Filling to Electric Poles, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deem to be included in the Quoted Unit Rate.

2.16

-

-

... More
M&LCement Concrete 1:2:4 (20mm graded stone aggregates) in Copping of Electric Poles, etc., Weathering Slightly Rounded or Chamfered Angle and Throating, Finishing all Exposed Faces of Concrete including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deem to be included in the Quoted Unit Rate.

0.42

-

-

... More
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, Providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and Numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Works & Concrete Works will be Measured and Paid separately under relevant Items.

2

-

-

... More
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, Fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., Welding, Bending Cold or Hot, Drilling Holes for Bolts, in any Shape or Size as indicated or directed and Applying Two Coats of Aluminium Paint over a Coat of Aluminium Oxide Primer after Preparation of Surfaces, complete all as specified and as directed.

1

-

-

... More
S&F Insulator Pin type, 100mm Height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, White, Brown or Green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.

30

-

-

... More
S&F Insulator Shackle type, Porcelain, Vitreous, White, Brown or Green of Size 75mm Height & 90mm dia including Galvanised Mild Steel Straps of Section 31x3.0mm, 12mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade, complete all as specified and as directed.

20

-

-

... More
M&L Vice type Connector consisting of Two Brass Plates, Two Steel Bolts and Nuts for 2 Conductors of Equal or Unequal Sizes for Non-Tension Connections 'including Treatment of Connector and ACSR Conductor with Conducting Jelly including Taking down Old Unserviceable Connectors, complete all as specified and as directed.

2

-

-

... More
M&L ACSR Conductor of any Size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement/ as directed.

1

-

-

... More
M&L Re-stressing/ Re-straining, Tightening & Re-fixing ACSR Conductor of any Size on Electric Poles including necessary Aluminium Binding Wire including Re-fixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.

2

-

-

... More
M&L Galvanised Iron Wire 3.15mm or 4.0mm dia as Continuous Earth Wire, Guards and Cradles (Hexagonal/ Rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.

0.2

-

-

... More
M&L Re-stressing/ Re-straining, Tightening & Re-fixing Cradles, Hexagonal/ Rectangular, Fabricated with Galvanised Steel Wire 3.15mm or 4.0mm dia from Electric Poles including GI Binding Wire 1.6mm dia, complete all as specified and as directed.

0.3

-

-

... More
S&F PVC Fiber Line Separator 2 Wire System, suitable for LT Line 1100 Volt Over Head Conductor for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.

30

-

-

... More
S&F PVC Fiber Line Separator 4 Wire System, suitable for LT Line 1100 Volt Over Head Conductor for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.

30

-

-

... More
M&L Stay Assembly Complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (White, Brown or Green) Overall Dimensions 90x140mm and Clear-ance of Hole 25.5mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised Steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of Size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Necessary Earth Works and Cement Concrete Works will be Measured and Paid separately under appropriate Items.

2

-

-

... More
S&F Anti-Climbing Device, Spikes type, Fabricated out of Mild Steel Bars (Round, Square and Flat) including Bolts, Nuts, Washers and Welding in Two Halves, made to Shape to suit the Cross Section of the Pole, complete all as specified and as directed.

0.1

-

-

... More
S&F Danger Notice Plate of Size 20x15 Cm for LT, made of 1.6 mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Clamps, Bolts & Nuts of approved Size, complete all as specified and as directed.

10

-

-

... More
S&F Danger Notice Plate of Size 25x20 Cm for LT, made of 1.6 mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Clamps, Bolts & Nuts of approved Size, complete all as specified and as directed.

8

-

-

... More
M&L Switch Air Break, Gang Operated of Current Rating upto 200 Amp, 11000 Volt, Triple Pole, Mechanically Operated mounted on Insulator and Steel Frame, with Operating Mechanism Worked from Ground Level, complete all as specified and as directed.

2

-

-

... More
M&L HT Lightening Arrester of Discharging Capacity 65 kA, 11000 Volts grade, Expulsion type and complete with all Fittings, complete all as specified and as directed. MAKE : ALSTOM/ CROMPTON GREAVES/ JAIPURIYA/ OBLUM

2

-

-

... More
M&L Painting to Erected HT Steel Tubular Pole (11 Metre long) except Embedded Portion but including all Mild Steel Works viz Cross Arms, Channels, Flat Iron Clamps, etc. with Two Coats of Aluminium Paints, Providing 07 No. Bands/ Straps with Synthetic Enamel Paint (any tint 30 Cm Wide/ Height Each) from Top of Plinth/ Concrete Block and Writing Letters/ Pole Number not less than 50mm with different Tint in Black Ground, complete all as specified and as directed. NOTE : Cost of any Arrangements/ Scaffolding required for Painting to Erected HT Steel Tubular Pole will deem to be included in the Quoted Unit Rate.

8

-

-

... More
M&L Tree Trimming, Cut away Dead or Excess Branches from Trees or Shrubs to Maintain Clearance along with Over Head Power Lines using Climbing Equipment and Collecting the Debris for Disposal and Removing Broken Limbs from Electric Wires by Using Hooked Extension Poles, complete all as specified and as directed. NOTE :- (a) Span will be taken as Distance between Two Adjacent Poles for Payment. (b) Cost of any Arrangements/ Scaffolding required for Tree Trimming will deem to be included in the Quoted Unit Rate.

30

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 10 Sqmm, 2 Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 16 Sqmm, 4 Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 25 Sqmm, 3½ Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 35 Sqmm, 3½ Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

60

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 50 Sqmm, 3½ Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 70 Sqmm, 3½ Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 95 Sqmm, 3½ Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

170

-

-

... More
Re-laying/ Re-fixing Serviceable Cable (Cable obtained from Taking down/ out) of Size 10/ 16/ 25 Sqmm, 2/3½/4 Core and Providing Electrical Connection including Cable Glands, Lugs, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
Re-laying/ Re-fixing Serviceable Cable (Cable obtained from Taking down/ out) of Size 35/ 50 Sqmm, 3½/4 Core and Providing Electrical Connection including Cable Glands, Lugs, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

25

-

-

... More
Re-laying/ Re-fixing Serviceable Cable (Cable obtained from Taking down/ out) of Size 70/ 95 Sqmm, 3½/4 Core and Providing Electrical Connection including Cable Glands, Lugs, laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable size Mild Steel Saddle, Clips (wherever Cable laid in Ceilings/ Walls without Cable Duct), complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

50

-

-

... More
M&L Cable Jointing Kit, Straight Through, Heat Shrinkable, suitable for LT PVC/ XLPE Insulated, Armoured, Aluminium Conductor Cable of Size 10 Sqmm to 50 Sqmm, 2/3½/4 Core with Jointing Accessories including Cutting Faulty Cable, complete all as specified and as directed. NOTE :- (a) Cutting of Faulty Cable, Joint will deem to be included in the Quoted Unit Rate. (b) Damaged LT Cable and Joint will be considered under Schedule of Credit. (c) Earth Works required for Straight Through Joints will deem to be included in the Quoted Unit Rate. In the case of Excavation required more than 10.00 RM for Joint of Cable, than it will be Measured and Paid for separately under appropriate Items.

5

-

-

... More
M&L Cable Jointing Kit, Straight Through, Heat Shrinkable, suitable for LT PVC/ XLPE Insulated, Armoured, Aluminium Conductor Cable of Size 70 Sqmm to 120 Sqmm, 3½/4 Core with Jointing Accessories including Cutting Faulty Cable, complete all as specified and as directed. NOTE :- (a) Cutting of Faulty Cable, Joint will deem to be included in the Quoted Unit Rate. (b) Damaged LT Cable and Joint will be considered under Schedule of Credit. (c) Earth Works required for Straight Through Joints will deem to be included in the Quoted Unit Rate. In the case of Excavation required more than 10.00 RM for Joint of Cable, than it will be Measured and Paid for separately under appropriate Items.

2

-

-

... More
Supply, Laying & Testing UG XLPE insulated, Screened, PVC Bedded, Galvanised Steel Strip or Wire Armoured, Electric Power Cables (Heavy duty) with Aluminium Conductor, 11000 Volts Grade (Earthed), Cross sectional Area 95 Sqmm, 3 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Walls, Poles, etc. including jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.

30

-

-

... More
M&L Cable Jointing Kit for 11 KV (Earthed) Grade Cable, OUTDOOR TERMINA-TION, Heat Shrink type complete with Jointing Materials and Accessories suitable for XLPE Armoured Aluminium Conductor Cable, Cross sectional Area 50 Sqmm to 95 Sqmm, 3 Core, Providing Connection and Testing including Taking down/ out Old Unserviceable Cable Jointing Kit of any description, complete all as specified and as directed.

2

-

-

... More
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above & around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.

39.2

-

-

... More
Supply & laying Sub-class ‘B’ Bricks of Size 230x115x75 mm, Kiln burnt, for Covering to UG Cable as Mechanical Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.

42.09

-

-

... More
Relaying of Serviceable Bricks (Bricks obtained from Taking down/ out Cable), for Covering to UG Cable as Mechanical Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.

10.52

-

-

... More
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts, etc., complete all as specified and as directed.

15

-

-

... More
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 50x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.

15

-

-

... More
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts, etc., complete all as specified and as directed.

10

-

-

... More
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 50x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.

10

-

-

... More
Supply & laying or Fixing or Passing through Pipe, 1100 Volts grade, Heavy duty Cable with PVC Insulated Aluminium Stranded Conductor, Nominal Cross Section 6.0 Sqmm, Twin Core, Served with an Inner Sheathing of PVC Tape Armoured with Galvanised Steel Wire or Tape and Overall PVC Sheathed and Providing Electric Connection, complete all as specified and as directed.

100

-

-

... More
Supply & laying or Fixing or Passing through Pipe, 1100 Volts grade, Heavy duty Cable with PVC Insulated Aluminium Stranded Conductor, Nominal Cross Section 10 Sqmm, Twin Core, Served with an Inner Sheathing of PVC Tape Armoured with Galvanised Steel Wire or Tape and Overall PVC Sheathed and Providing Electric Connection, complete all as specified and as directed.

100

-

-

... More
M&L Plates (Plain or Chequered) 7.0mm thick in Duct Covering, Conform to Fe-410-W (Gde-E-250, Quality 'A'), Cut to Size and Length as required/ ordered, Channels, Square Cut or Notched (Ordinary and Counter Sunk) Forming Holes, without any Attachment including Applying a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.

0.5

-

-

... More
S&F Pre-painted Galvalume Aluminium Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Red Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with and including Aluminium Self Tapping Screws and Aluminium Washers of suitable Size, complete all as specified and as directed.

10

-

-

... More
Supply, Installation, Testing & Commissioning LT Outdoor Feeder Pillar Box, Minimum Size 1200x900x600mm, Factory Made (CPRI Certified/ Tested Manufacturer), made out of 3.15mm thick CRCA Sheet with Angle Iron Frame 50x50x5.0mm, AC 415 Volt, 50 Hz, 3 Phase, 4 Wire, Prewired with suitable Size Copper wire, Totally Enclosed, Self Supporting Structure/ Cubicle, Fully Compartmentalized Type, Weather Proof, Protection IP-54, Double Doors, with Bottom Cable Entry with suitable Cable Glands, 4 No. Angle Iron Frame/ Legs grouted to PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangement for Bus-bars Ammeter, Voltmeter, Changeover and MCCBs with Sloping Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangement including Louvers at Sides duly Powder Coated complete for accommodating with and including following Accessories:- BUS-BARS : (a) Aluminium Bus-bar 400 Amp, supported on Non-hygroscopic Fibers - 04 No. and Brass Screws with Bolts, Nuts & Washers INCOMER : (b) MCCB 250 Amp, 4 Pole, 415 Volt, 35 kA Breaking capacity, with - 01 No. Fixed Thermal & Fixed Magnetic Setting OUTGOING : (c) MCCB 125 Amp, 4 Pole, 415 Volt, 25 kA Breaking capacity, with - 01 No. Thermal Magnetic Release (d) MCCB 63 Amp, 4 Pole, 415 Volt, 16 kA Breaking capacity, with - 02 No. Thermal Magnetic Release (One Standby) (e) MCCB 40 Amp, 4 Pole, 415 Volt, 16 kA Breaking capacity, with - 02 No. Thermal Magnetic Release (One Standby) INDICATING DEVICES : (f) LED Indicating Lamps for Main Supply indicating R-Y-B - 03 No. (g) Digital Ampere Meter 0-250 Amp, 3 Phase, Class 1, with CT having - 01 No. CTR 250/5 (h) Digital Voltmeter 0-500 Volt, 3 Phase, Class 1 - 01 No.

1

-

-

... More
M&L Repair/ Maintenance LT Panel Door by Replacement Hinges, Locking Arrangements including necessary Welding and Providing Bolts, Nuts, Washers as per existing Size/ Type, complete all as specified and as directed. NOTE : One Side Door will be Measured & Paid for as EACH JOB. Cost of any Minor Addition and Alteration as per requirement, Taking down/ out MCCB, Ammeter, Voltmeter, Selector Switch, Indicating Lamps, etc. will deem to be included in Quoted Unit Rate.

2

-

-

... More
S&F MCCB 63 Amp, 4 Pole, 25 kA Breaking Capacity, 415 Volt, AC, 50 Hz, with Overload And Thermal Tripping Features complete with suitable Spreader, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed. NOTE : Cost of any Minor Addition and Alteration as per requirement, Bolts, Nuts & Washers, and Cable Lugs for Fixing of MCCB in Existing Panel will deem to be included in Quoted Unit Rate.

1

-

-

... More
S&F MCCB 100 Amp, 4 Pole, 25 kA Breaking Capacity, 415 Volt, AC, 50 Hz, with Overload And Thermal Tripping Features complete with suitable Spreader, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed. NOTE : Cost of any Minor Addition and Alteration as per requirement, Bolts, Nuts & Washers, and Cable Lugs for Fixing of MCCB in Existing Panel will deem to be included in Quoted Unit Rate.

1

-

-

... More
S&F MCCB 125 Amp, 4 Pole, 25 kA Breaking Capacity, 415 Volt, AC, 50 Hz, with Overload And Thermal Tripping Features complete with suitable Spreader, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed. NOTE : Cost of any Minor Addition and Alteration as per requirement, Bolts, Nuts & Washers, and Cable Lugs for Fixing of MCCB in Existing Panel will deem to be included in Quoted Unit Rate.

2

-

-

... More
S&F MCCB 200 Amp, 4 Pole, 36 kA Breaking Capacity, 415 Volt, AC, 50 Hz, with Overload And Thermal Tripping Features complete with suitable Spreader, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed. NOTE : Cost of any Minor Addition and Alteration as per requirement, Bolts, Nuts & Washers, and Cable Lugs for Fixing of MCCB in Existing Panel will deem to be included in Quoted Unit Rate.

1

-

-

... More
S&F MCCB 250 Amp, 4 Pole, 36 kA Breaking Capacity, 415 Volt, AC, 50 Hz, with Overload And Thermal Tripping Features complete with suitable Spreader, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed. NOTE : Cost of any Minor Addition and Alteration as per requirement, Bolts, Nuts & Washers, and Cable Lugs for Fixing of MCCB in Existing Panel will deem to be included in Quoted Unit Rate.

1

-

-

... More
S& Digital Ammeter 0-400 Amp, Flush Mounting type, 3 Phase, Class 1 with suitable CTs of Range as required, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed.

2

-

-

... More
S&F Digital Voltmeter 0-500 Volt AC, Flush Mounting type, 3 Phase, Class 1, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed.

2

-

-

... More
S&F Selector Switch, suitable for APFC/ LT Panel, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed.

2

-

-

... More
S&F LED Indicator as per Colour Scheme ( Red, Yellow, Blue, Green), suitable for APFC/ LT Panel, Fixing and Electrically Connected in Existing Panel, complete all as specified and as directed.

10

-

-

... More
M&L Broken/ Crushed Stone Aggregate 20mm graded, Spreading in layer not exc. 100mm thick Each Layer, complete all as specified and as directed.

9

-

-

... More
M&L Broken/ Crushed Stone Aggregate 40mm graded, Spreading in layer not exc. 100mm thick Each Layer around the Transformer, VCB and Panel at Sub-station, complete all as specified and as directed.

10

-

-

... More
Supply & Laying Synthetic Rubber Insulated Mat of Size 2000x1000x2.5mm thick suitable for Voltage 11 KV for Electrical Purpose as per IS:15652-2006, (superseding IS:5424) suitable for Electrical Shock Safety including Taking out/ Removing Old Unserviceable/ Torn out Mat, complete all as specified and as directed.

6

-

-

... More
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and Connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in Alternate Layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both Ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of Surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.

8

-

-

... More
M&L Earthing with Copper Earth Plate Electrode 600x600x3.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Copper Earth Strip of Size 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and Connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in Alternate Layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both Ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of Surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.

4

-

-

... More
S&F in repair Galvanised Iron Strip 32x6.0mm with Saddles and Fixing Screws for Conductors/ Earth Lead including Brazing/ Welding and Bolts, Nuts & Washers, Bolt Jointing at all Joints for Building/ Equipments, laid through Pipe/ Trench/ Surface, complete all as specified and as directed.

40

-

-

... More
S&F in repair Copper Strip 20x3.0mm with Saddles and Fixing Screws for Conductors/ Earth Lead including Brazing/ Welding and Bolts, Nuts & Washers, Bolt Jointing at all Joints for Building/ Equipments, laid through Pipe/ Trench/ Surface, complete all as specified and as directed.

24

-

-

... More
M&L Disconnecting Distribution Transformer Outdoor type from HT & LT Side, Opening Carefully at Site, Draining out Transformer Oil (Keep Safe in Barrel for Re-use) upto HT/LT Box for Rectifying the Leakage by Replacing the Unserviceable Spare Parts of Capacity upto 400 KVA, 11/0.433 KV Transformer, Refilling the Transformer Oil and Re-assembling after Repair including Testing for any Oil Leakages and Connecting the HT/LT Side and Testing on available Electric Load, complete all as specified and as directed. NOTE :- (a) Defective Parts will be Measured and Paid for separately as 'Supply only' under appropriate Items here-in-below. (b) Cost of Welding Work (if required), Taking down/ out of Unserviceable Breather Assembly with Silca Gel, Bushing, Gaskets, etc. and Fixing of New Items will deem to be included in the Quoted Unit Rate.

3

-

-

... More
Supply only Breather Assembly with Silca Gel and Vent Pipe for Indoor/ Outdoor Transformer upto 400 KVA, complete all as specified and as directed.

3

-

-

... More
Supply only Porcelain Bushing suitable for LT Side (as Approved/ as per Existing Specifications) including Brass Stems Conical Bush and Gasket, complete all as specified and as directed.

4

-

-

... More
Supply only Porcelain Bushing suitable for HT Side (as Approved/ as per Existing Specifications) including Brass Stems Conical Bush and Gasket, complete all as specified and as directed.

3

-

-

... More
Supply only Top Cover Gasket Set (as Approved/ as per Existing Specifications), complete all as specified and as directed.

3

-

-

... More
M&L ON LOAD Centrifuging and Dehydration including Filteration and Cleaning of Transformer Oil by Dehydration Machine Electrically Operated without any Shutdown of Transformer including Testing Oil Sample before and after Dehydration and Filteration Oil, complete all as specified and as directed. NOTE :- (a) Transformer Oil required for Top-up will be Measured and Paid for separately as 'Supply only' under appropriate Item here-in-below. (b) Contractor will arrange the Dehydration Machine and Testing Kit from his own Arrangement and Cost for the same will deem to be included in the Quoted Unit Rate.

710

-

-

... More
Supply & Filling/ Toping up Transformer Oil in Transformer having Dielectric Strength not less than 40 KVA at 2.5mm Gap High Voltage as per IS/ IEC Specifications of Low Viscosity, complete all as specified and as directed. NOTE : Dielectric Test will be carried out before Filling of Oil in Transformer and Cost for the same will deem to be included in the Quoted Unit Rate.

210

-

-

... More
S&F Air Breather Assembly Transparent Plastic Body with Top and Bottom Portion Pressed with Metallic Cover, Filled with New Silica Gel (Blue in Colour) suitable for Isolation Transformer, fixing on Existing Pipe of Size 15/ 20/ 25mm bore (dia) with suitable Reducer/ Connector complete as per Site requirement including Taking down/ out Unserviceable Air Breather Assembly, complete all as specified and as directed. NOTE : Cost of Modification (if required to Fix on Existing Pipe) will deem to be included in the Quoted Unit Rate.

3

-

-

... More
Supply, Fixing & Testing Externally Operated Tap Changer Switch Off Load type after Dismantling of Transformer Conservator Tank/ Top Cover and Re-assembling the same after Replacing, suitable for upto 400 KVA Transformer including Taking down/ out Unserviceable Tap Changer Switch, complete all as specified and as directed.

1

-

-

... More
S&F Temperature Gauge (as Approved/ as per Existing Make and Specifi-cations), 0°C to 120°C Range Dial Temperature including Taking down/ out Unserviceable Temperature Gauge, complete all as specified and as directed.

2

-

-

... More
S&F Transformer Oil Level Indicator Assembly upto 400 KVA Transformer (as Approved/ as per Existing Make and Specifications), complete with Iron Frame, Glass, Rubber Packing Sheet, Bolts Nuts & Washers including Taking down/ out Unserviceable Oil Level Indicator Assembly, complete all as specified and as directed.

2

-

-

... More
M&L Preparing Old Painted Steel or Iron Surfaces of Isolation Transformer upto 400 KVA Capacity Complete with all Connected Fittings & Fixtures and Other Standard Fittings & Attachments by Cleaning with Scrapers and Emery Paper to the Entire Satisfaction, Applying Two Coats of Synthetic Enameled Paint with Spray Painting Machine (including bringing Compressor of suitable Size at Site), complete all as specified and as directed. NOTE : Contractor will Apply One Layer of Grease over Specification Plate/ any Written Letter before Painting and Clean the Same after Painting and Cost for the Same will deem to be included in the Quoted Unit Rate.

3

-

-

... More
Bidder(s) is/ are required to Quote the EQUAL AMOUNT (as per SCHEDULE OF CREDIT at SERIAL PAGE No. 26 of Tender documents) under Column 5 i.e. 'UNIT RATE' (M) against Row No. 108 .

1

-

-48106



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.