Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date8 Jan 2025
Closing Soon29 Jan 2025
Tender Amount₹ 43,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SPECIAL REPAIR TO BLDG NO OWT-640, OWT-641, OWT-642, OWT-643 PROVN OF PATIENTS WAITING ROOM FOR OFFRS, JCOS/ORS AT MH AND PROVN OF 02 X SEPTIC TANK WITH 02 X SOAKAGE WELLS FOR 25 USERS WITH CONNECTED ALLIED WORKS AT LIKABALI MIL STN UNDER GE 872 EWS
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for Vitrified, designed, light shade coloured (light shade), tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.

400

-

-

... More
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.

78.5

-

-

... More
M & L for 75 mm thick, Plain cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in footpath/hardstanding, etc and finished the surface even and fair without using extra cement complete all as specified and directed.

130

-

-

... More
M & L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc, including 20 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed with grey cement and pigments to match with the shade of tiles complete all as specified and directed.

130

-

-

... More
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.

10.5

-

-

... More
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed.

325.5

-

-

... More
S & F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed.

1050

-

-

... More
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.

465

-

-

... More
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.

31.5

-

-

... More
Demolition of brick work or stone / boulder masonry/ precast concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish complete all as directed by the Engr-in-Charge.

1.5

-

-

... More
M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.

26.8

-

-

... More
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed

60

-

-

... More
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.

20

-

-

... More
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).

185

-

-

... More
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.

15

-

-

... More
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.

20

-

-

... More
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.

50

-

-

... More
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid/frame work etc complete all as specified and directed.

190

-

-

... More
S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestor E-board, HSPC, designer, pre-primed, self exposed, textured, water resistant, termite resistant, fire resistant for insulation board fixed to frame complete all as specified and directed by the Engr-in-Charge.

190

-

-

... More
S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.

40.2

-

-

... More
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.

100.5

-

-

... More
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.

20

-

-

... More
Taking down shutters of any description exc 2 Sqm each complete all as specified and directed.

16

-

-

... More
S & F 35 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.

16.8

-

-

... More
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.

16

-

-

... More
S & F Powder coated aluminium sections (minimum 50 micron) of approved colour as in door, window, ventilator frames, partitions with one or more rebates and door, windows shutters sliding/openable type/ventilator shutter including provision of necessary jointing cleats, glazing clips, neoprene rubber packing, powder coated aluminium snap beading, screws inclding provision of suitable size of powder coated aluminium fittings such as locking arangements, handles, stainless steel fiction hinges and tower bolts etc including fixing only glass panels/particle board panels/wire gauge/aluminium grill etc complete all as specified and directed. (Note : (i) The size of aluminium sections shall be all as specified in relevant IS Code and MES Schedule Part-I (ii) Glass panels/ Partricle Board panels/ Wire gauge etc shall be measured paid seperately as supply only rates under respective items here-in-below).

200

-

-

... More
Supply only 5.5 mm thick, sheet glass, ordinary quality and glazing with beading for door/window etc in square exceeding 0.5 Sqm in each pane complete all as specified and directed. (Note: The cost of fixing and glazing beads included with the unti quoted rate of respective shutter)

17.6

-

-

... More
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.

24

-

-

... More
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.

16

-

-

... More
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.

16

-

-

... More
S & F 300 mm Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt complete all as specified and directed.

8

-

-

... More
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.

40

-

-

... More
M & L for Preparation of old treated asbestos building board surfaces of walls etc of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.

600

-

-

... More
S & F in repairs 24 mm outer dia, stainless steel, curtain rail/rod, heavy duty, minimum 1mm wall thick including brackets, side holder and rings etc fixed to /wall etc complete all as specified and directed. (Note: (i) Stainless steel decorative finials and stainless steel brackets shall be provided for each leangth of curtain rail/rod and cost of the same shall deemed to be included in the unit quoated rate. (ii) Length of of curtain rail/rod shall only be measured for payments)

34

-

-

... More
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.

150

-

-

... More
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed.

12

-

-

... More
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.

260.5

-

-

... More
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed.

900

-

-

... More
S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed.

12

-

-

... More
S & F Mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n.exc 30cm long complete all as specified and directed.

10

-

-

... More
M & L for plain Cement Concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in post, walls, retaining walls, ballast walls and the likes any thickness, above top of footings including attached pilasters and buttreses complete all as specified and directed.

1.5

-

-

... More
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.

23.7

-

-

... More
M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.

150

-

-

... More
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing, etc, complete all as specified and directed.

150

-

-

... More
Excavation over areas, n.exc 1.5 m in depth and getting out in soft/loose soil complete as specified and directed.

140

-

-

... More
Excavation over areas, exc 1.5 m and n.exc 3.0m in depth and getting out in soft/loose soil complete as specified and directed.

140

-

-

... More
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.

1.2

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.

74

-

-

... More
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.

5.8

-

-

... More
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.

16

-

-

... More
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.

54

-

-

... More
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.

82

-

-

... More
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.

23

-

-

... More
M & L for Reinforced Cement Concrete 1:1.5:3, type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings and mass concrete, etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)

2.9

-

-

... More
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)

2.8

-

-

... More
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, shelves etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)

8.3

-

-

... More
M & L Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)

4.8

-

-

... More
S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.

1400

-

-

... More
S & F high strength Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.

250

-

-

... More
M & L for Pre-cast cement concrete type 1:3:6 (using 16mm graded stone aggregate), block masonry with hollow blocks, as in honeycomb walling, exc. 10 cm in width and setting in mortar 1:4 complete all as specified and directed.

4

-

-

... More
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.

20

-

-

... More
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.

11

-

-

... More
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.

4

-

-

... More
S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.

2

-

-

... More
S & F 75 mm bore, PVC (SWR) vent cowl complete all as specified and directed.

2

-

-

... More
M & L for Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in landing, cover slabs, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed. (Note: Reinforcement shall be measured and paid seperately)

0.04

-

-

... More
M & L for loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage well complete all as specified and directed.

24

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.

100

-

-

... More
Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.

5

-

-

... More
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.

15

-

-

... More
M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)

52

-

-

... More
All as per item No. 74 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto

8

-

-

... More
All as per item No. 74 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto

32

-

-

... More
All as per item No. 74 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto

8

-

-

... More
S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.

60

-

-

... More
S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed.

8

-

-

... More
S & F Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.

32

-

-

... More
S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.

8

-

-

... More
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.

36

-

-

... More
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casin capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin capping shall be measured as one length)

15

-

-

... More
S & F 2ftx2ft recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)

16

-

-

... More
S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)

8

-

-

... More
S & F LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)

12

-

-

... More
S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.

12

-

-

... More
S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDNTHCDRW04 or equivalent make as per List of Manufacturer's)

1

-

-

... More
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)

4

-

-

... More
S & F Isolator, 4 pole, 100 Amps, 415 Volts complete all as specified and as directed (Make: Havell's cat part No. DHMGIFPX100 or equivalent make as per List of Manufacturer's)

1

-

-

... More
S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)

6

-

-

... More
S & F MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)

4

-

-

... More
S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)

24

-

-

... More
Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable minor parts such as spilt pins, screws, nuts and spring washers etc complete including provn of flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required and re-fixing the ceiling fan in its existing position after rewinding complete all as specified and directed. (Note : (i) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding of fan shall be measured and paid seperately and shall be carried out in contractor's workshop and fan shall be re-fixed at site withing 10 days after taking down from site. Any delay after 10 days shall be panalised @ Rs. 100.00 per day for a maximum of 10 days).

12

-

-

... More
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 94 above)

7

-

-

... More
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The ceiling fan taken down under Serial item No. 94 shall be painted and measured under this item.)

12

-

-

... More
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.

12

-

-

... More
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.

4

-

-

... More
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)

70

-

-

... More
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work shall be measured paid seperately)

80

-

-

... More
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)

9

-

-

... More
Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed.

774

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.