Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Pipe Line Project
Electrical Works
Eprocure
Opening Date23 Jul 2024
Closing Date6 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 35 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

200

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 50 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

200

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 70 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

200

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 95 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

100

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 120 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

100

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 150 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

100

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 185 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

100

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 240 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

100

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 300 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

20

-

-

... More
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty with aluminium conductor, 1100 volts LT grade of cross-sectional area 400 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid including commissioning and testing complete all as specified and as directed. Note: :- (a) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (b) The cost of taking down of UG cable is included in the quoted rate.

20

-

-

... More
Supplying and fixing in repair,1100 volts grade heavy duty cable PVC insulated aluminium stranded 10Sqmm conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.

200

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.

405

-

-

... More
Excavation in trenches not exceeding 1.5m wide and excedding 1.5m and not exceeding 3.00m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.

0.54

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.

262

-

-

... More
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.

143

-

-

... More
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned/Compacted thickness of Sand Cushioning only shall be measured and paid.

121.5

-

-

... More
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.

12000

-

-

... More
S&F in repair, Cable jointing kit for LV/LT 1100 V cable for straight through, heat shrinkable type joint kit complete with jointing material and accessories suitable for 35 Sqmm to 50 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.

6

-

-

... More
S&F in repair, Cable jointing kit for LV/LT 1100 V cable for straight through, heat shrinkable type joint kit complete with jointing material and accessories suitable for 70 Sqmm to 95 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.

6

-

-

... More
S&F in repair, Cable jointing kit for LV/LT 1100 V cable for straight through, heat shrinkable type joint kit complete with jointing material and accessories suitable for 120 Sqmm to 185 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.

4

-

-

... More
S&F in repair, Cable jointing kit for LV/LT 1100 V cable for indoor/outdoor end terminal joint, heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.

3

-

-

... More
S&F in repair, Cable jointing kit for LV/LT 1100 V cable for indoor/outdoor end terminal joint, heat shrinkable type joint kit complete with jointing material and accessories suitable for 70 Sqmm to 150 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.

2

-

-

... More
S&F in repair, Cable jointing kit for LV/LT 1100 V cable for indoor/outdoor end terminal joint, heat shrinkable type joint kit complete with jointing material and accessories suitable for 185 Sqmm to 400 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.

3

-

-

... More
M&L boring holes horizontally under Road without damaging the surface of road ( minimum 1.0 Mtr below the road surface with the help of GI tubing of any dia not exceeding 80 mm bore for passing of UG cable all as specified and as directed. Note:- GI pipe laid shall be measured and paid seperately.

50

-

-

... More
S&F in repair, GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, including necessary preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified

50

-

-

... More
S&F in repair, GI pipe light grade 50 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, including necessary preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified

40

-

-

... More
S&F in repair, GI pipe light grade 80 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, including necessary preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified

40

-

-

... More
M&L servicing of LT panel of any type and size by checking connection of busbar with switchgear, internal wiring system of metering devices, proper fixing of switch gear, replacing of burned/damaged insulators,connecting copper lead with held of copper lugs ,nut bolts, replacing of unserviceable copper bus bars, complete all as specified and directed. Note: Cost of copper lead wire and copper bus bar, MCCB as required shall be measured under other appropriate items and paid seperately.

10

-

-

... More
S&F 16 sqmm single core PVC insulated, multistranded, copper conductor for fixing in LT panel from bus bar to switch gear as connector lead complete all as specified and directed.

100

-

-

... More
S&F insulated copper bus bar of any size in replacement in existing LT panel complete all as specified and directed

2

-

-

... More
S&F aluminium lugs 25 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

100

-

-

... More
S&F aluminium lugs 35 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

100

-

-

... More
S&F aluminium lugs 50 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

50

-

-

... More
S&F aluminium lugs 70 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

40

-

-

... More
S&F aluminium lugs 95 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

30

-

-

... More
S&F aluminium lugs 120 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

30

-

-

... More
S&F aluminium lugs 150 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

30

-

-

... More
S&F aluminium lugs 185 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

20

-

-

... More
S&F aluminium lugs 300 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

20

-

-

... More
S&F aluminium lugs 400 sqmm in existing panel or LV side of distribution transformer compelete all as directed.

20

-

-

... More
M&L earthing complete with GI Earth Plate Electrode 600mm x 600mm x 6mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to GI earth strip 25x4 mm drawn through and including Galvanised Iron protection Pipe 32 mm bore (dia) Light grade up to height of the transformer foundation where transformer is situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.

5

-

-

... More
S&F and testing MCCB 4 pole 63 Amps of breaking capacity 25 KA suitable for 415 volts, 50 Hz, with extended terminal in existing LT Panel including removal of existing unserviceable one complete all as specified and directed.

10

-

-

... More
S&F and testing MCCB 4 pole 100 Amps of breaking capacity 25 KA suitable for 415 volts, 50 Hz, with extended terminal in existing LT Panel including removal of existing unserviceable one complete all as specified and directed.

9

-

-

... More
S&F and testing MCCB 4 pole 160 Amps of breaking capacity 25 KA suitable for 415 volts, 50 Hz, with extended terminal in existing LT Panel including removal of existing unserviceable one complete all as specified and directed.

9

-

-

... More
S&F and testing MCCB 4 pole 200 Amps of breaking capacity 36 KA suitable for 415 volts, 50 Hz, with extended terminal in existing LT Panel including removal of existing unserviceable one complete all as specified and directed.

8

-

-

... More
S&F and testing MCCB 4 pole 250 Amps of breaking capacity 36 KA suitable for 415 volts, 50 Hz, with extended terminal in existing LT Panel including removal of existing unserviceable one complete all as specified and directed.

8

-

-

... More
S&F and testing MCCB 4 pole 400 Amps of breaking capacity 36 KA suitable for 415 volts, 50 Hz, with extended terminal in existing LT Panel including removal of existing unserviceable one complete all as specified and directed.

4

-

-

... More
Supply, installing out door type Feeder Pillar Box of size 600 x 450 x 300mm, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement and painted with powder coating paint and mounted on PCC Platform all round the Feeder Pillar Box complete including copper bus bar TPN 415 Volts, 50 Hz of rating 400 Amp duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and rating as per site requirment and good insulation resistance with removal of old unseviceable pedestal type Feeder Pillar Box, complete all as specified and as directed. Note :- Rate Quoted is deemed to inclusive of PCC (1:3:6) type C-2( using 40mm graded crushed stone aggregate)

5

-

-

... More
S&F and testing thermal magnectic ACB in existing LT Panel of capacity 630 Amps breaking capcity 50 KA suitable for 415 volts, 50 Hz, with extended terminals type, interlocked to prevent opening when the Switch is in ON Position, confirming to IS /IEC 60947-2, high mechanical and electrical operating life protection through thermal magnectic DN-1 and connecting and testing complete including removal of exsting unsv all as specified and directed.

1

-

-

... More
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation of pole, mass concrete including necessary formwork ad required complete all as specified and as directed.

0.42

-

-

... More
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of pole, including necessary formwork ad required complete all as specified and as directed.

4.2

-

-

... More
M&L PCC (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in Copping of pole, including necessary formwork ad required complete all as specified and as directed.

0.96

-

-

... More
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 METRE long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally) above copping shall be painted with in alternate band/strip of black and yellow colour starting with black colour upto height of 1.5 from top of copping, writing MES Pole No. with synthetic Enamel Paint (First Grade/quality)including Dismantling unserviceable Steel Tubular Poles including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. NOTE: (i) Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. (ii) Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed and cost of Earthwork, demolition of Cement Concrete, etc. is deemed to be inclusive in Unit Rate Quoted

10

-

-

... More
M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 16mm, size of Plate 230x230x6mm including 7/3.15 mm Galvanised Stay Strand,Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x65mm, clearance of hole 16mm dia, MS clamp made out of 50mm x 6mm with nuts bolts wahers as required including Dismantling Stay Assembly complete all as specified and as directed. NOTE:(i) Earthwork, Cement Concrete, will be measured and paid under approprite Items. (ii) Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. is deemed to inclusive in the Unit Rate Quoted

10

-

-

... More
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, complete all as specified and directed.

2

-

-

... More
S&F Galvanised steel wire 3.15 or 4mm dia., as in earth continuity conductor and fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., including Dismantling Galvanised steel wire Conductors complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

1

-

-

... More
S&F Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia and binding to Insulators with Aluminium Binding Wire including stringing, tightening, etc., including Dismantling Cradles, complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

1

-

-

... More
S&F Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia and binding to Insulators with Aluminium Binding Wire including stringing, tightening, etc., including Dismantling Cradles, complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

1

-

-

... More
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade including Dismantling Insulators like from existing Street/ Security Light Pole complete all as specified and as directed.

75

-

-

... More
Fixing only serviceable Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade including Dismantling Insulators like from existing Street/ Security Light Pole complete all as specified and as directed.

60

-

-

... More
S&F Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 90mm height 75mm dia including Galvanised Mild Steel 31x3mm Strap, 12mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, including Dismantling Insulators like from existing Street/ Security Light Pole complete all as specified and as directed.

50

-

-

... More
Fixing only serviceable Insulator Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 90mm height 75mm dia including Galvanised Mild Steel 31x3mm Strap, 12mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, including Dismantling Insulators like from existing Street/ Security Light Pole complete all as specified and as directed.

40

-

-

... More
M&L Loop type insulator, vitreous porcelain, white, brown or green, Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and as directed.

40

-

-

... More
S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc.,fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., including Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc.complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

8

-

-

... More
Re-stringing to OH Line ACSR Conductor on existing Lines by un-binding from the Insulator of any description, re-fixing after stretching the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, complete all as specified and as directed. NOTE :– (a)Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

20

-

-

... More
S&F PVC Line separtor for LT overhead conductor 2 Wire system for horizontal spacing, fixed with nuts, bolts washers etc complete all as specified and directed

60

-

-

... More
S&F PVC Line separtor for LT overhead conductor 4 Wire system for horizontal spacing, fixed with nuts, bolts washers etc complete all as specified and directed

60

-

-

... More
Trimming /pruning of the tree branches coming around the overhead line and making the OH Line from touching the tree branches not less the 3 mtr radius complete all as specified and as directed.

200

-

-

... More
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, complete all as specified and as directed.

300

-

-

... More
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings of 8.5/9 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, complete all as specified and as directed.

245

-

-

... More
M&L writing Letter on steel Tubular/Pre-stressed concrete pole (8 cm in heght ) with synsthetic Enamel paint (white) on base of black paint in round shape of 15 cm dia complete all as specified and as dirtected.

545

-

-

... More
Fixing Only LT UG XLPE cable of size 25 Sqmm, 3.5 Core aid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. Note: (i) LT UG cable 25 Sqmm, 3.5 Core will be issuued under Sch B (ii) Earthwork, Sand coushioning, brick protection will be measured and paid under appropriate Items.

145

-

-

... More
Fixing Only LT UG XLPE cable of size 50 Sqmm, 3.5 Core aid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. Note: (i) LT UG cable 50 Sqmm, 3.5 Core will be issuued under Sch B (ii) Earthwork, Sand coushioning, brick protection will be measured and paid under appropriate Items.

319

-

-

... More
M&L supply, fabrication, installation, connection, commissioning and testing of outdoor type LT Panel box (CPRI approved) made out of 3.15 mm thick CRCA sheet metal being MM size, double door suitable MS angle iron base frame, cubical type floor mounted 3 Ph 4 wire, 415 V front operated IP 54 protection, properly insulated aluminium bus bar 04 Nos having capacity 240 Amps on phase and neutral, dust and vermin proof both side open with locking arrangement comprising of multifunction meters with LCD display of voltage, current and frequency and power factor, suitable ratio CT's phase indicator 03 sets, selector switches, danger board plate completely painted internally and externally with powder coated having sufficient space around MCCB in MCCB compartment for carrying out repairs fixing in position by provision of platform siutable size with brick work in CM (1:6) including glands, lugs, thimbles to connect the cable etc, for all incoming and outgoing cables complete all as specified and directed. Busbar: 240 Amps rated Aluminum busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance. Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : - (a) INCOMING (i) MCCB 160 Amps, 4 pole, 415 V, 36 kA (Ics = 100% Icu) - 1 No (ii) Digital multifuctional meter showing Amp/Volt/PF/Frequency - 1 No (iii) R ,Y , B indicator Lamps 1 Set (b) OUTGOING (i) MCCB 100.Amps, 4 pole, 415 V, 25 kA (Ics = 100% Icu) - 1 No (ii) MCCB 63 Amps 4 Pole , 415 V , 25 kA (Ics = 100% Icu) - 1 No

1

-

-

... More
M&L supply, fabrication, installation, connection, commissioning and testing of outdoor type LT Panel box (CPRI approved) made out of 3.15 mm thick CRCA sheet metal being MM size, double door suitable MS angle iron base frame, cubical type floor mounted 3 Ph 4 wire, 415 V front operated IP 54 protection, properly insulated aluminium bus bar 04 Nos having capacity 240 Amps on phase and neutral, dust and vermin proof both side open with locking arrangement comprising of multifunction meters with LCD display of voltage, current and frequency and power factor, suitable ratio CT's phase indicator 03 sets, selector switches, danger board plate completely painted internally and externally with powder coated having sufficient space around MCCB in MCCB compartment for carrying out repairs fixing in position by provision of platform siutable size with brick work in CM (1:6) including glands, lugs, thimbles to connect the cable etc, for all incoming and outgoing cables complete all as specified and directed. Busbar: 240 Amps rated Aluminum busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance. Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted. : - (a) INCOMING (i) MCCB 400 Amps, 4 pole, 415 V, 36 kA (Ics = 100% Icu) - 1 No (ii) Digital multifuctional meter showing Amp/Volt/PF/Frequency - 1 No (iii) R ,Y , B indicator Lamps 1 Set (b) OUTGOING (i) MCCB 200 Amps 4 Pole , 415 V , 25 kA (Ics = 100% Icu) - 2 Nos (ii) MCCB 100 Amps 4 Pole , 415 V , 25 kA (Ics = 100% Icu) - 2 Nos (iii) MCCB 63 Amps 4 Pole , 415 V , 25 kA (Ics = 100% Icu) - 1 No

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.