Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 92,220Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669132_1Bid Award Id
ViewTender No
GE(N)/TEZ/2024-2025/8966Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
180
-
-
... More
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges.
17824
-
-
... More
Taking out the existing ACSR Conductor /PVC/XLPE, 1100 volts grade, LT UG electric cable of any size and any type in trenches/ walls/ overhead lione (or) passing through pipes/in floor complete all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items:-
2785
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 25 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
80
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 35 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
120
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 50 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
150
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 70 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
185
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
110
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 150 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
85
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 185 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
75
-
-
... More
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 240 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
65
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
250
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 35 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
320
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 50 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
465
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 70 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
385
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
290
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 150 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
95
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 185 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
70
-
-
... More
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 240 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
40
-
-
... More
Supply and jointing in repairs/replacement straight through heat shrink joint kit for PVC/XLPE LT UG cable for 25 to 50 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
4
-
-
... More
Supply and jointing in repairs/replacement straight through heat shrink joint kit for PVC/XLPE LT UG cable for 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
6
-
-
... More
Supply and jointing in repairs/replacement straight through heat shrink joint kit for PVC/XLPE LT UG cable for 150 to 185 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
7
-
-
... More
Supply and jointing in repairs/replacement straight through heat shrink joint kit for PVC/XLPE LT UG cable for 240 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
2
-
-
... More
Supplying & laying in repair 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
40
-
-
... More
Supplying & laying in repairs/replacement 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
30
-
-
... More
Supplying & laying in repairs/replacement 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
20
-
-
... More
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from steel tubular poles (above the planting depth and PCC copings of 11.0 Metre length Pole) and mild steel cross arms, cable protection pipe, brackets, etc. and applying one coat of red oxide zinc chrome primer, alternate yellow & black strips painting (4 Nos. each strip 200 mm wide) and remaining portion of pole and cross arms, cable protection pipe, brackets, etc. treated with two coats of Aluminium paint, complete all as specified and as directed.
115
-
-
... More
Supply & erecting steel tubular swaged pole type 410-SP-55 (11.0 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surafaces of steel tubular poles with two coats of Aluminium paint over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint including taking down the old unserviceable fitting all as specified and as directed by the Engineer-in-Charge.(Exixting Connection two pole structure to four pole structure at Thakurbari Subs staion 1 &2 ,Phulbari ss)
1
-
-
... More
Re Fixing for Steel tubular swaged poles any type and any size after taking dwon with proper shut dwon without damage for pole any location within 100 mts complete including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surafaces of steel tubular poles with two coats of Aluminium paint over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.complete all as specified and as directed.
6
-
-
... More
M&L in repairs/replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colo dismantling unserviceable one, complete all as specified and as directed .
34
-
-
... More
Road cutting for passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core. Complete all as specified and directed
2
-
-
... More
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
3
-
-
... More
S& F in repairs/replacement GI earthing strip 25x4 mm with nut and bolts comoplete including taking down old one all as specified and directed by Engr- in- Charge
110
-
-
... More
S&F in repairs/replacement GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,buried in ground including excavation complete all as specified and directed by Engr-in-Charge.
83
-
-
... More
Supply , fabrick , install, test and commssiong LT outdoor type bus bar box made out of 3.15 mm thick MS sheet with suitable size of MS angle iron/flat support including painting and epoxy powder coated grey colour, wheather proof and vermine proof with air fins for cooling with locking arragement complete of adequate size to accommodate the following accessories :- (i) TPN 415 Volts Alu bus bar ,800 Amps mounted on suitable insulation. (ii) Cable gland detachable plates for termination of incoming and outgoing cables with suitable nuts and washers etc. (iii) Earth terminal points
10
-
-
... More
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.Necessary foundation work as per manufacturer instraction including foundation and including taking down the old panel required at site and comprising following:- Incoming : (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos, (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3, (C ) S&F Ammeter and voltmeter digital multy meter Nos -01, (d ) S&F for MCCB 250 Amp 36 KA 4 pole Thermal magnatic setting complete - N0s -01, outgoing : (a ) S&F MCCB of 4 pole of capacity 63 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 03 Nos, (a ) S&F MCCB of 4 pole 160 amps, with breaking capacity of 25 KA with fixed thermal & fixed magnetic setting, - 01 Nos
5
-
-
... More
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.Necessary foundation work as per manufacturer instraction including foundation and including taking down the old panel required at site and comprising following:-Incoming : (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos, (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3, (C ) S&F Ammeter and voltmeter digital multy meter Nos -01, (d ) S&F for MCCB 250 Amp 36 KA 4 pole Thermal magnatic setting complete - N0s -01, ( e ) Change over switch 250 Amp 4 pole front loaded operated 415 volts Nos -01, outgoing : (a ) S&F MCCB of 4 pole of capacity 100 amps, with breaking capacity of 25 KA with fixed thermal & fixed magnetic setting - 03 Nos, (a ) S&F MCCB of 4 pole of capacity 63 amps, with breaking capacity of 25 KA with fixed thermal & fixed magnetic setting - 03 Nos
1
-
-
... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
18
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements