BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,71,600Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_657411_1Bid Award Id
ViewTender No
84062/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying, Installation, Commissioning & Testing Sluicing Machine, Minimum 15 KG Capacity Per Charge, Steam heated, Front Loading, Soft Mount, High Spin, including Electrical Control Panel with Automatic Dosing to Wash the Infected and Soiled Clothes received from Wards, ICU's and OT's, complete all as specified and as directed.
1
-
-
Supplying, Installation, Commissioning & Testing Auto Clave Machine, Minimum 30 KG Capacity with Automatic Control feature including Electrical Control Panel and Providing all Electrical Connections, complete all as specified and as directed.
1
-
-
Suppling, Installation, Commissioning & Testing Diesel Fired Boiler 400 KG Capacity, Coil type, HSD Fired Steam Boiler with 990 Litre Diesel Tank, 1000 Litre Water Tank & 20 Feet Chimney including Electrical Control Panel and Providing all Electrical Connections, complete all as specified and as directed.
2
-
-
Suppling, Installation, Commissioning & Testing Air Compressor 5.0 HP AC-5, 2 Stage 2 Cylinder having Piston Displacement 18 cfm with 220 Litre Tank, Automatic Pressure Switch, Belt Guard, V-Belts, NRV, Safety Valve, Ball Valve, Pressure Gauge, Drain Plug, Motor Pulley, Flywheel, Air Filter suitable for 5.0 HP Electric Motor, complete all as specified and as directed.
1
-
-
S&F Flat Bed Drying Press Machine of Size 1500x750mm, Steam heated of Head Bed with Steam heated Pneumatically Operated Powerful Suction Blower Attached including Silicon Padding Head Teflon Cloth Lined for Fine Pressing, Automatic Digital Temperature Control, complete all as specified and as directed.
2
-
-
S&F Flat Work Ironer Machine Single Roller, Steam heated Roller Heated, Minimum Size of the Roller 530mm (Dia) x 3000mm (Length), Roll Heated. Front Feed, Front Return, Steam heated Pneumatically Operated Ironing Chest. Adjustable Ironing Pressure. Variable Frequency Inverter Drive. Perforated Roller with Centrifugal Moisture, complete all as specified and as directed.
2
-
-
S&F Dry Linen Trolley (Cage Type) 50 KG Capacity Formed out of Stainless Steel Tubes & Bars, Electro treated, Foldable Front, Fitted with 4 No. Swiveling type Ball Bearing Wheels, complete all as specified and as directed.
3
-
-
S&F Mobile Trolley 50 KG Capacity Formed out of Stainless Steel Tubes & Bars, Electro treated, Foldable Front, Fitted with 4 No. Swiveling type Ball Bearing Wheels, complete all as specified and as directed.
2
-
-
S&F Wet Linen Trolley (Box Type) 50 KG Capacity, Formed out of Stainless Steel Tubes & Bars, Electro treated, Fitted with 4 No. Swiveling type Ball Bearing Wheels, complete all as specified and as directed.
3
-
-
S&F Water Softener Plant suitable for 300 PPM Hardness & 500 PPM TDS, 160 Litre, Compact & Flexible Softening Systems, complete all as specified and as directed.
1
-
-
S&F/ Providing following Items for Installation of all Items from Sl No. 2 to 13 :-
(a) Soft Water Service Tank, Main Storage Tank, Transfer Pump, etc.
(b) MS Chimney with Bend and Duct between Boiler & Chimney
(c) Diesel Tank 990 Litre with Heavy duty MS Plate.
(d) Steam Water Fuel Water and Drain Piping up to Terminal Point.
(e) All Electrical Works in Boiler House
(f) ‘C’ Class Fitting and Steam Pipe Fitting for suitable Arrangement from Boiler to all Machinery.
(g) Installation all Steam Pipe Line and Top Cover Cladding with Aluminum Sheet.
NOTE :-
(a) The Unit Rate is inclusive of all Labours, Tools and Tackles Utilities and Consumables required for Assembling, Erecting and Commissioning the Boiler.
(b) Fuel, Water Instruments and Accessories required for Commissioning, Operation and for Performance Testing of Boiler.
1
-
-
Demolition Cement Concrete (Un-reinforced) of any description and in any Situations not otherwise Provided for, not exc. 150mm thickness (above or below Ground Level) and Removing Debris, etc. to a Distance exc. 50.00 Metre and not exc. 100.00 Metre, complete all as specified and as directed.
10
-
-
Demolition Brick Masonry Work, built in Cement Mortar including all Quoins, Arches and Pillars, etc. and Removing Debris, etc. to a Distance exc. 50.00 Metre and not exc. 100.00 Metre, complete all as specified and as directed.
10
-
-
Taking up or down Steel Tubing 40mm bore (dia) and Fittings/ Connections of any description from any Situations, complete all as specified and as directed.
80
-
-
Taking down Carefully Copper/Aluminium Point Wiring (Light, Socket or Power) complete from in any Position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Sockets (but excluding Light Fittings of any description), complete all as specified and as directed
45
-
-
Taking down/out Unserviceable Sub-main Wiring in Surface PVC Casing Capping/ Concealed Conduit from any Situations of any description, complete all as specified and as directed.
200
-
-
M&L Cement Concrete 1:2:4 (40mm graded stone aggregates) in Foundations, Filling and Mass Concrete, etc. including Use & Waste of necessary Formwork as required/ ordered, complete all as specified and as directed.
NOTE : Cost of Formwork will deem to be include in the Quoted Unit Rate.
5
-
-
M&L Cement Concrete 1:2:4 (20mm graded stone aggregates) in Lintels upto 1.50 Metre Clear Span, Cills, Steps; Seismic and other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings upto 600mm in Height, Apex Stones, Bed Plates, Copings, Kneelers and the Like including Weathering, Slightly Rounded or Chamfered Angles and Throating, Finishing all Exposed Faces of Concrete including Use & Waste of Formwork as required/ ordered, complete all as specified and as directed.
NOTE : Cost of Formwork will deem to be include in the Quoted Unit Rate.
5
-
-
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed.
10
-
-
M&L Rendering 15mm thick on Bricks or Concrete Surfaces in Cement Mortar 1:6, Finished Plastered Surfaces Even and Smooth Without Using Extra Cement, complete all as specified and as directed.
50
-
-
M&L Preparing New Plastered Surfaces on Walls and Applying Three Coats of White Wash, complete all as specified and as directed.
50
-
-
S&F Galvanised Steel Tubing 40mm bore (dia), Medium grade, conform to IS-1239 with all Fittings, fixed to Walls, Ceiling or laid in Floors, complete, complete all as specified and as directed.
80
-
-
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable as Earth Continuity Wire, drawn through and including suitable Size Non-metallic Rigid PVC Conduit, Medium duty, ISI Marked with all Conduit Accessories, Concealed in Walls/ Ceiling/ Fixed to Roof, etc., Fabricated Steel Sunken Terminal Box duly painted, made out of 1.6mm thick MS Sheet, Concealed in Walls, etc. with 3.0mm thick Bakelite/ PVC Sheet, ISI Marked Top Cover, Fixing with Brass Chromium Plated Screws and Cup Washers for Housing Switches, Socket Outlets, Fan Regulators, etc. for One Light Controlled by One 1-Way Switch, complete all as specified and as directed.
NOTE : Cost of Cutting into Chases to Walls required for Concealed Conduit and Making Good to damaged Surfaces will be Measured and Paid separately under appropriate Item.
20
-
-
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable as Earth Continuity Wire, drawn through and including suitable Size Non-metallic Rigid PVC Conduit, Medium duty, ISI Marked with all Conduit Accessories, Concealed in Walls/ Ceiling/ Fixed to Roof, etc., Fabricated Steel Sunken Terminal Box duly painted, made out of 1.6mm thick MS Sheet, Concealed in Walls, etc. with 3.0mm thick Bakelite/ PVC Sheet, ISI Marked Top Cover, Fixing with Brass Chromium Plated Screws and Cup Washers for Housing Switches, Socket Outlets, etc. for ONE 6 AMP SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and as directed.
NOTE : Cost of Cutting into Chases to Walls required for Concealed Conduit and Making Good to damaged Surfaces will be Measured and Paid separately under appropriate Item.
10
-
-
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable as Earth Continuity Wire, drawn through and including suitable Size Non-metallic Rigid PVC Conduit, Medium duty, ISI Marked with all Conduit Accessories, Concealed in Walls/ Ceiling/ Fixed to Roof, etc., Fabricated Steel Sunken Terminal Box duly painted, made out of 1.6mm thick MS Sheet, Concealed in Walls, etc. with 3.0mm thick Bakelite/ PVC Sheet, ISI Marked Top Cover, Fixing with Brass Chromium Plated Screws and Cup Washers for Housing Switches, Socket Outlets, etc. for ONE 16 AMP SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and as directed.
NOTE : Cost of Cutting into Chases to Walls required for Concealed Conduit and Making Good to damaged Surfaces will be Measured and Paid separately under appropriate Item.
15
-
-
M&L Sub-main Wiring with 4-Runs of 6.0 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable and 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable as Earth Continuity Conductor drawn in Surface/ Concealed including suitable Size PVC Conduit, Medium duty, ISI Marked with all Conduit Accessories, complete all as specified and as directed.
NOTE :-
(a) Cost of 6-Runs of Cable & 1-Run of Conduit will deemed to be included in the Quoted Unit Rate and the same Measured as ONE UNIT.
(b) Sub-main Wiring will be measured PVC Conduit only. Cost Wire required for Looping, etc. will deem to be include in the Quoted Unit Rate.
(c) Cutting into Chases to Walls required for Concealed PVC Conduit and Making Good to Surfaces shall be Measured and Paid separately under appropriate Item.
100
-
-
M&L Sub-main Wiring with 4-Runs of 10 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable and 2-Runs of 10 Sqmm (nominal area) 1100 Volt grade PVC Insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable as Earth Continuity Conductor drawn in Surface/ Concealed including suitable Size PVC Conduit, Medium duty, ISI Marked with all Conduit Accessories, complete all as specified and as directed.
NOTE :-
(a) Cost of 6-Runs of Cable & 1-Run of Conduit will deemed to be included in the Quoted Unit Rate and the same Measured as ONE UNIT.
(b) Sub-main Wiring will be measured PVC Conduit only. Cost Wire required for Looping, etc. will deem to be include in the Quoted Unit Rate.
(c) Cutting into Chases to Walls required for Concealed PVC Conduit and Making Good to Surfaces shall be Measured and Paid separately under appropriate Item.
100
-
-
M&L Cutting Chases for Concealed Conduit Wiring, Pinning in, Depth not exc. 50mm and Girth not exc. 10 Cm, Making Good to Disturbed Portion/Surfaces of Walls/ Floor/ Ceiling, etc. with Cement Mortar 1:3 including Applying Surface Treatment (White/ Colour Washing/ Distempering/ Painting) to match the Existing Finishes, complete all as specified and as directed.
100
-
-
S&F Switch Piano 6 Amp, Single Pole, 1-way, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
30
-
-
S&F Switch Piano 16 Amp, Single Pole, 1-way, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
15
-
-
S&F Socket Outlet 6 Amp, 5 Pin, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
10
-
-
S&F Socket Outlet 16 Amp, 6-in-1, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
15
-
-
S&F Ceiling Rose Surface Bakelite 65x50mm, 3 Terminal suitable for 230 Volt AC and Connecting up, complete all as specified and as directed.
20
-
-
S&F LED Light Fitting 1x20 Watt, 4 Feet, 230 Volt AC, Integrated, Decorative Box type with LED Light, Driver, Holder, Connecting up with and including Copper Conductor Cable of Size 0.5 Sqmm of suitable Length including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
20
-
-
S&F MCCB 200 Amp, 4 Pole, 50 Hz, 25 kA, 415 Volt, Thermal Magnetic type with Spreader Terminals and Connecting up including Taking down/out Unserviceable MCCB of any description, complete all as specified and as directed.
1
-
-
S&F Factory made Vertical Distribution Board Sheet Metal Enclosure 8-way, TPN, 415 Volt, Metal Door, IP-43 Protected with 200 Amp rated Bus-bar, having facility for MCCB Incoming up to 250 Amp and MCB Outgoing, fixed Flush with Wall inside the Niches or Outside on Wall Surface and Connecting up including Taking down/out Unserviceable Distribution Board of any description and Making Good Disturbed Surfaces of Walls with Cement Mortar 1:3 and Providing Surface Treatment (White Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
1
-
-
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 450x450x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I, Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
NOTE : All Joints should be joined by Exothermic Welding or Brazing.
2
-
-
LESS SCHEDULE OF CREDIT
Bidder shall QUOTE the EQUAL AMOUNT (as per SCHEDULE OF CREDIT of TENDER DOCUMENTS) under Column 'UNIT RATE (M)' against ROW No. 53.
1
-11345
-