Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679508_1Bid Award Id
ViewTender No
634/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Motor upto 7.5 HP
4
-
-
Motor upto 10 HP
4
-
-
Motor upto 15 HP
2
-
-
M&L Repair reconditioning of monoblock pump/centrifugal pump Connection will be disconnected and pump will be degutted from foundation and transported to the civil shop. Pump will be dismantled completely and inspection will be carried out. After complete inspection of the pump any machining jobs will be carried out. Mechanical seals,gland packing, o-rings and other consumbles will be renewed major over hauling of the pump will be carried out and boxed back test bed trails will be carried out our work shop at 1.5 times the working pressure pumps will be transported back to Chabua and regutting be done pump shifted to site and reinstalled at its original position including allignment with pump/motor with electrical connections and testing for best performance complete all as directed of the following capacities :-
-
-
-
Pump up to 5 HP
4
-
-
Pump upto 7.5HP
3
-
-
Pump upto 10 HP
2
-
-
Pump upto 15 HP
4
-
-
Taking down unserviceable coupling Condenser /chiller motor to be boxed back and supply and fixing new coupling and alignment, any machining jobs will be carried out all as specified and as directed .
2
-
-
M&L for taking down defective unserviceable pressure gauge supply and fix new pressure gauge 0-150 PSI chiller/condenser water line and all as specified and as directed.
10
-
-
M& L for taking down defective unserviceable Thermometer supply and fixing new thermometer of Range 0 to 50°F for condenser/ Chiller inlet/ outlet pipe complete all as specified and as directed.
10
-
-
M& L for taking down defective unserviceable single phase preventer Supply and fixing new Single Phase Preventor, 415 Volts, Type VSP-2 complete all as specified and as directed Make Minilec.
4
-
-
M& L for taking down defective unserviceable single phase preventer Supply and fixing new Single Phase Preventor, 415 Volts, Type VSP-3 complete all as specified and as directed Make Minilec.
6
-
-
M& L for taking down defective unserviceable V-type belt Supply and fixing V-Type Belt suitable for Existing Model V belt complete all as specified and as directed.
20
-
-
Disconnection of chilled water line taking down Y type Strainer servicing fillter replacing net/nut volt clenning Y type strainer 100 mm dia including all accessories, packing, nuts and bolts refixing at existing position complete all as specified and as directed .
4
-
-
Disconnection of chilled water line taking down Y type Strainer servicing fillter replacing net/nut volt clenning Y type strainer 80 mm dia including all accessories, packing, nuts and bolts refixing at existing position complete all as specified and as directed .
1
-
-
Disconnection of chilled water lineMaterial and Labour for dismantling unserviceable Butterfly valves any type 50 mm dia and supply and fix new valve 50 mm dia , butterfly type , including replacement of bolts , nuts , washers and rubber gaskets all as directed.
2
-
-
Material and Labour for dismantling unserviceable Butterfly valves any type 80 mm dia and supply and fix new valve 80 mm dia , butterfly type , including replacement of bolts , nuts , washers and rubber gaskets all as directed.
1
-
-
Material and Labour for dismantling unserviceable Butterfly valves any type 100 mm dia and supply and fix new valve 100 mm dia , butterfly type , including replacement of bolts , nuts , washers and rubber gaskets all as directed.
2
-
-
Material and Labour for dismantling unserviceable Butterfly valves any type 125 mm dia and supply and fix new valve 125 mm dia , butterfly type , including replacement of bolts , nuts , washers and rubber gaskets all as directed.
2
-
-
Taking down existing defectiive panel board indication lamp (R/Y/B/G) colour from the panel and replacing with new LED indicator lamp complete all as specified and as directed.
5
-
-
Material & Labour for taking down the defective unserviceable power contactor of and burned out copper wire, lugs, and S&F of new power contactor 3TF46 3 pole, 220-240 coil volt, including the copper wire & copper lugs and testing Sutaible for existing model complete all as directed. Make :- Siemens/L&T.
2
-
-
Material & Labour for taking down the defective unserviceable power contactor of and burned out copper wire, lugs, and S&F of new power contactor 3TS47 3 pole, 220-240 coil volt, including the copper wire & copper lugs and testing Sutaible for existing model complete all as directed. Make :- Siemens/L&T.
2
-
-
S&F MPD Power supplier of capacity 4-61Amps auxilary supply,11 V,AC to 13 VAC,230V,50Hz,AC in repairs , incl taking down old u/s complete all as directed.
2
-
-
M&L for complete rectification testing overhauling and modification of electrical Main compressor panel will be opened cleaned and check for loose connection an will be tightened accordingly, all the relays ,fuse, connectors,lugs ,other related equipment in the system will be checked and damaged equipment will be replaced with new spares,wiring of the pannel carried out, all other protection will be checked and will make them in operation, includes replacement of burnt out lugs,busbar unserviceable contactors, cleaning of panel, checking of serviceable and operational condation, ensure of panel door closing, incl same colour existing painting complete all as manufacturees instruction all as specified and directed by Engineer- in - charge. Note :i) The rate quoted shall be deemed to included for lugs ,busbar modification, T&P,MS nuts,bolts,pannel painting , ii) S&F spare parts shall be measured and paid seperately agains respective item .
2
-
-
Supply and fixing in repair MCCB 250 Amps FP 36 KA 415 Volt existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair contactor 3 pole MNX 32 existing model and make complete all as specified and directed.
6
-
-
Supply and fixing in repair power contactor 3 pole MNX 18 existing model and make complete all as specified and directed.
6
-
-
Supply and fixing in repair power contactor 3 pole MNX 12 existing model and make complete all as specified and directed.
6
-
-
Supply and fixing in repair power contactor 3 pole MNX 9 existing model and make complete all as specified and directed.
6
-
-
Supply and fixing auxiallry contactor MNX-A1existing model and make complete all as specified and directed.
6
-
-
Supply and fixing auxiallry contactor MNX-A2 existing model and make complete all as specified and directed.
6
-
-
Supply and fixing in repair contactor 3 pole MNX 70 existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair contactor 4 pole MCX 41, 2NO+ 2 NC existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair thermal over load relay range 4.5-7.5 amps existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair thermal over load relay range 6-10 amps existing model and make complete all as specified and directed.
2
-
-
Supply and fixing in repair thermal over load relay range 9-15 amps existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair thermal over load relay range 14-23 amps existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair electronic timer 240/415 V,50 HZ for 3-30 Sec existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair HRC cylindrical fuse link electronic timer 240/415 V,50 HZ for 3-30 Sec existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair Energy KWH LED meter squre type existing model and make complete all as specified and directed.
1
-
-
Supply and fixing in repair single function meter 1 ph LED ammeter squre type existing model and make complete all as specified and directed.
2
-
-
Supply and fixing in repair single function meter 1 ph LED voltmeter squre type existing model and make complete all as specified and directed.
2
-
-
Supply and fixing in repair ammeter,3 phase existing model and make complete all as specified and directed.
4
-
-
Supply and fixing in repair Voltmeter 3 phase . existing model and make complete all as specified and directed.
4
-
-
Supply and fixing in repair flush push button spring return existing model and make complete all as specified and directed.
4
-
-
Supply and fixing in repair low pressure switch existing model and make, incl taking down old u/s complete all as specified and directed.
4
-
-
Supply and fixing in repair high pressure switch existing model and make , incl taking down old u/s complete all as specified and directed.
4
-
-
Supply and fixing in repair thermostate switch existing model and make , incl taking down old u/s complete all as specified and directed.
4
-
-
Supply and fixing in repair of dryer 5/8 all as existing model and make , incl taking down old u/s complete all as specified and directed.
4
-
-
Supply and fixing in repair of dryer 1/2 all as existing model and make , incl taking down old u/s complete all as specified and directed.
4
-
-
Supply and fixing MCB upto 40 amps 3 pole existing model and make complete all as specified and directed.
3
-
-
supply and fixing current transformer secondary current 5 amp and primary current 60 amp including taking down old current transformer complete all as specified and as directed.
3
-
-
supply and fixing power contactor assembly complete 32 Amps as per existing incl repair complete all as specified and as directed.
2
-
-
Disconnecting wiring carefully and removing defective auxillary power contactor assembly complete and replacing by new one of same make and model reconnecting wiring and testing on completion 400/415 V as per existing incl repair complete all as specified and as directed.
3
-
-
M&L for taking down the defective Induction Motor bearing of any make / model shifted to work shop for dismantling motor , replacing bearing with new ball bearing of the following sizes complete all as directed. Make :-NBC/SKF
-
-
-
Ball bearing 6204
3
-
-
Ball bearing 6205
3
-
-
Ball bearing 6206
4
-
-
Ball bearing 6207
4
-
-
M&L for removing pillow block bearing at site and replacing the pillow ball bearing with new pillow bearing size upto shaft dia 63.5 incl any machining ,alignment of shaft,impeller jobs will be carried out complete all as directed. Make :-NBC/SKF
2
-
-
Removing unserviceable,corroded MS ERW pipe of 100 mm dia and S&F upto 100 mm dia MS Pipe (heavy grade) with necessary fittings like Elbow, flanges, bolts, nut and valve strainers, including supports complete as in water pipe lines including testing and commissioning complete all as directed. Make :- Jindal/Tata/Prakash
10
-
-
M&L for complete rectification testing overhauling of Hot water generator Capacity 170 KW Make: KECL damaged spare parts to running condition replacement unserviceable parts digital step controller display ,relay ,heater assembly ,contactors, checking of serviceable and operational condation of hot water generator , complete all as manufacturees instruction all as specified and directed by Engineer- in - charge. as per existing OEM. Note :i) The rate quoted shall be deemed to included for labour, T&P,MS nuts,bolts, painting , ii) supply only spare parts shall be measured and paid seperately agains respective item and the unit rate quoted shall deemed to included the cost of labour for fixing the spares .
2
-
-
Supply only Digital step controller display complete set for hot water genertaor 170 KW complete all as specified and directed.
1
-
-
Supply only Controle Module card with relay complete set for hot water genertaor 6.70 KW complete all as specified and directed.
2
-
-
Supply only immersion type water heater assembly of capacity 8.34 KW suitable for Emrald make hot water generator complete all as per existing model and make complete all as specified and directed.
6
-
-
Supply only immersion type water heater assembly of capacity 6.70 KW suitable for Emrald make hot water generator complete all as per existing model and make complete all as specified and directed.
2
-
-
Supply only Limit Switch suitable for hot water generator complete all as per existing model and make complete all as specified and directed.
2
-
-
Supply only Water Thermostat suitable for hot water generator complete all as per existing model and make complete all as specified and directed.
2
-
-
Supply only Air Release Valve suitable for hot water generator complete all as per existing model and make complete all as specified and directed.
2
-
-
Supply only Rubber Gasket suitable for hot water generator complete all as per existing model and make complete all as specified and directed.
4
-
-
Supply & fixing Hot water flow switch of hot water generator including taking down old and fixing new along with wiring complete all as specified and directed by Engr-in-Charge
2
-
-
Supply and fixing in repair MCCB 100 Amps TPN 30 KA 415 Volt existing model and make complete all as specified and directed.
2
-
-
Supply and fixing in repair MCCB 63 Amps TPN 30 KA 415 Volt existing model and make complete all as specified and directed.
2
-
-
Supply and fixing in repair MCB 6 to 32 Amps 10 KA 230 Volt existing model and make complete all as specified and directed.
4
-
-
Supply and fixing in repair MNX25 ,3 phase 415 Volt existing model and make complete all as specified and directed.
10
-
-
Dismantling/taking down the old damaged /corroded part of the fondation of motor and pumps renewed repair foundation of motor and pump incl MS support channel ,hard standing painted in existing colour and proper alignment of motor,pump complete all as specified and as directed by the Engineer-in-Charge.
2
-
-
Material and labour for sub main wiring with 4x 6 sq mm single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2x4 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with including cutting chases pinning and making good disturbed surface complete all as specified and as directed.
40
-
-
Supply and fixing copper cable PVC insulated sheathed 1100 volts grade multi core copper conductor round 3 core 6 Sq.mm,incl taking down old u/s ,all as specified and directed.
30
-
-
Supply and fixing copper cable PVC insulated sheathed 1100 volts grade multi core copper conductor round 3 core 4 Sq.mm,incl taking down old u/s ,all as specified and directed.
30
-
-
Material and labour for taking down the burnout / defective scroll type compressor Capacity upto 12.5 TR unit and repair the factory through OEM replacement of unserviceable worn out parts in the compressor , cleaning the system, compressor winding ,compressor oil ,terminal block refixing the same in its original position and re connecting all disconnected lines welding /copper brazing etc, in serviceable and operational condation complete all as manufactureres instruction and as directed by Eng-in- charge.including testing and commissioning Carried out through OEM . complete all as specified and directed.
Note :- (i) Leak test , Vacuuming and Refrigerant gas shall be measured separately under relevant items. (ii) Compressor shall have warranty of six months and the contractor is responsible for the maintenance of Compressor during that period.
2
-
-
Material & Labour for carrying out the leak test for the chiller any type system by extracting the existing available gas from the system to seperate cylinder storing and pressurizeing the complete system with dry nitrogen and check the leak rectification of leaks by brazzing /welding at the leak points /replacing by damaged valve gland package /gasket etc,and after rectification of all leak pressure testing & holding the pressure for 24 Hours,complete system after releasing the dry nitrogen and charging the refrigerent gas,desire pressure to system testing and comissioning the plant checking all control complete all as directed by Engr-in-charge. Note:- i) once the gas charged in it ,it should hold in the system to minimum six month and in case of any leakage from the system the contractor has to charge the gas upto required level on free of cost and no exra cost on this accont shall be claimed .ii )refrigerent gas shall be measured and paid seprately under relevent item as supply only.
-
-
-
3 TR Capacity
8
-
-
12 TR Capacity
1
-
-
25 TR Capacity
2
-
-
80 TR Capacity
1
-
-
Supply and chargeing refrigerent Gas R 22 all as specified and as directed Make Floron/Mafron.
80
-
-
Supply and chargeing refrigerent Gas R 407 all as specified and as directed Make Floron/Mafron.
110
-
-
Supply andpouring in topup compressor oil . all as specified and as directed.
30
-
-
Attending to break down of central type AC plant of any capacity by only auth OEM rep/team for fault finding incl attending repairs as and when required such as no start condition of AC plant and repairing,starting, the operating parameter of the chillers checking any vibration,functioning microprocessor,flow swich calibration ,HP/LP cut out swich ,oil pump and oil heater checking the AC plant till smooth running and setting up the a required parameter of all minor parts such as compressor microprocessor based central AC plant ,general repair smooth and trouble free operation of plant to the entire satisfaction of user /dep. attending break down inspection service report duly mentioning the date of inspection signature of service engineer, engineer -in- charge shall be submitted for claming payment ,as required in ground as ordered by Engr-in-charge.
9
-
-
Material & Labour for carrying out the descaling of the shell & Tube condensers by isolation of each condenser by providing of dummy plate for inlet & outlet connection and separation of condenser from water circulation without disturbing the operation of the AC plant, carrying out the descaling by circulation of the diluted scale removing agent organic compound type chemical of RA III / chemtex Brand at the appropriate ratio depend upon as recommended by manufacturer and the scale deposit inside copper tube by forced circulation and opening the end covers, mechanical brushing the copper tubes with nylon brushes of various size to remove complete scale, de-greasing with caustic soda solution and flushing out with fresh water, refixing all disconnected pipes lines, end covers with new rubber gasket and opening water line valves and checking of water leakages, apply grease to all M.S. Bolts & Nuts and put the condensers of the following capacities in operational complete all as directed.
-
-
-
3x13 TR Capacity
3
-
-
3x 25 TR Capacity
3
-
-
Material & Labour for carrying out the chemical servicing of the Air cooled condensers & cooling coils by applying the non-aciditic scale removing agent to the fins area of the cooling coil, copper tubes, remove the complete scale deposit across the coil, flushing through and complete blowing out the dirt, cleaning the fan impellers, filter section, fan section, and complete cleaning filters, tightening of all bolts & nuts, renew the rusted bolts & nuts checking the alignment of the drive set and testing & commissioning the Air cooled condenser of split AC up to 3 TR complete all as directed.
9
-
-
Material & Labour for carrying out the chemical servicing of the Air cooled condensers & cooling coils by applying the non-aciditic scale removing agent to the fins area of the cooling coil, copper tubes, remove the complete scale deposit across the coil, flushing through and complete blowing out the dirt, cleaning the fan impellers, filter section, fan section, and complete cleaning filters, tightening of all bolts & nuts, renew the rusted bolts & nuts checking the alignment of the drive set and testing & commissioning the Air cooled condenser of AC Plant up to 80 TR complete all as directed.
4
-
-
Material & Labour for carrying out the chemical servicing /checking/inspection of the Air Handling units & cooling coils by applying the non-aciditic scale removing agent to the fins area of the cooling coil, copper tubes, remove the complete scale deposit across the coil, flushing through and complete blowing out the dirt, cleaning the fan impellers, filter section, fan section and complete cleaning of filters, tightening of all bolts & nuts, renew the rusted bolts & nuts checking the alignment of the drive set ,greasing of blower motor ,checking of electrical connection,cleaning of air filter,replacement of un serviceable bearing renewal of rusted sheet metal screws ,applying synthetic enamel paint over a coat of primer on the rused portion and testing & commissioning the Air Handling units of AC Plant complete all as directed by Eng-in-charge.
-
-
-
25 TR Capacity
4
-
-
50 TR Capacity
2
-
-
80 TR Capacity
3
-
-
Material & Labour for taking down the defective AHU shaft by dismantling the drive set, dismantling the AHU fan section, filter section, impellers etc and taking out the shaft, transporting to work shop and carrying out the repair by filling the metal on the worn out portion, both end, machining to the standard size of the bearing, removing the bend and checking the balancing fixing back to position, assembling dismantled sheet metal parts and testing commissioning the AHU of various capacity AC plants including necessary alignment of drive set complete all as directed.
2
-
-
M&L for disconnecting electical/ mechanical connections defective unserviceable Motor from cooling tower , taking down the defective Induction Motor of any make / model shifted to work shop for dismantling motor , remove burnt out winding from stator and rewinding the stator with same gauge super enamelled copper conductor with necessary insulation materials , varnishing backing re-assembling motor including replacement of both end bearings complete after complete the job motor shifted to site and reinstalled at its original position including allignment with with electrical connections and testing for best performance complete all as directed of the fo capacities:-
-
-
-
a) upto 05 HP.
1
-
-
Cleaning of PVC tank with bleaching powder and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 1000 ltr but n.exc 2000 ltr and painting the date of cleaning.
5
-
-
Shifting /Transporting repairable out door 03 phase 50 HZ split /ductile AC 3TR from various location (Chabua) to contractor’s workshop for repair, jointing by brazing leakage cheacking vacuum, servicing, overhauling including cleaning of air filter checking of wiring and rectification of any nature of defects, replacing only of spares as condenser PCB repair, contactor repair, complete refrigerant charge required and refixing at the site of removal complete machine and testing complete.
14
-
-
Supply, commissioning & testing scaled type Reciprocating compressor unit of capacity 03 TR. R-22. specified and as directed by Engr-in-Charge. Note :- R-22 gas shall be measured and paid separately.
4
-
-
Supply and fixing in repair Indoor door pvc fan blower 03 TR unit, incl taking down old u/s complete all as specified and directed by Engr-in-Charge. (As per existing OEM)
4
-
-
Dismantling and taking down carefully u/s indoor electronic type power circuit board at existing location repair by artisan & refixing testing of split type AC of capacity 03 TR complete unit all as specified and directed by Engineer-in-Charge
6
-
-
Dismantling and taking down carefully u/s outdoor electronic type power circuit board at existing location repair by artisan & refixing testing of split type AC of capacity 03 TR complete unit all as specified and directed by Engineer-in-Charge
6
-
-
Supply and fixing in repair power circuit board(Mother Board) indoor/outdoor type for 3 TR split AC, 3-phase incl taking down old u/s complete all as specified and as directed by Engr-in-Charge. (As per existing OEM)
5
-
-
M&L for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 3TR capacity and supply & fixing new fan motor suitable for split type ACs complete all as specified and as directed by the Engineer-in-Charge.
4
-
-
M&L for taking down the defective unserviceable sealed motor of outdoor unit of any make split unit of 3TR capacity and supply & fixing new fan motor suitable for split type ACs complete all as specified and as directed by the Engineer-in-Charge.
4
-
-
Supply & Fix in repair fan blade (indoor door) 24" suitable for 3 TR split AC incl taking down old u/s all as specifed and directed by Engr-in-Charge.
4
-
-
Supply & Fix in repair commissioning & testing sealed type scroll compressor unit of capacity 5.5 TR. R-407, 03 phase 50HZ Make Model ZR81 incl taking down old u/s. complete all as specified and as directed.
2
-
-
S & F in repairs, Keniform of best quality for split type AC to insulation copper pipe complete all as specified and as directed by Engr-in-Charge.
51
-
-
Supply & Fix in repair copper pipe 5"/8" suitable for 3 TR split AC incl taking down old u/s all as specifed and directed by Engr-in-Charge.
20
-
-
Supply & Fix in repair copper pipe 3"/8" suitable for 3 TR split AC incl taking down old u/s all as specifed and directed by Engr-in-Charge.
20
-
-
S&F in repair of Condensor Safety valve Size 3/8” inc taking down old u/s all as specified and as directed.
3
-
-
S&F in repair nozzles of cooling tower capacity 50TR , incl taking down old u/s complete all as specified and directed by Engr-in-Charge.
22
-
-
S & F in repair expensation valve for 5.5 TR, Sutaible for existing make /model AC Plant as per OEM incl taking down old u/s all as specified and as directed.
2
-
-
Supply & Fix in repair MCB TPN of 10-32 A incl taking down old u/s all as specified and directed by Engr-in-Charge.
6
-
-
Supply & Fix in repair MCB TPN of 63 A incl taking down old u/s all as specified and directed by Engr-in-Charge.
2
-
-
Supply and fixing in repair sensors suitable for 2x12 TR AC Plant as per OEM, incl taking down old u/s all as specified and as directed.
1
-
-
Supply and fixing in repair sensors suitable for 3x80 TR AC Plant as per OEM incl taking down old u/s all as specified and as directed.
1
-
-
Supply and fixing in repair sensors suitable for 3x24 TR AC Plant as per OEM incl taking down old u/s all as specified and as directed.
1
-
-
M&L for taking down the damaged drain pipe and supply & fixing of new insulated drain pipe suitable for split type ACs complete all as specified and as directed by the Engineer-in-Charge.
20
-
-
M&L in repairs for suction and liquid line insulation thermo foam, pipe section type, suitable for 1.5/2/3 TR capacity split type ACs complete all as specified and as directed by the Engineer-in-Charge.
4
-
-
M&L for complete scraping out of the rusted painting surfaces of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty/metal paste, prepare the surface, apply two coats of synthetic enamel paint over one coat of red oxide primer for 1.5/2/3 TR capacity split type ACs complete all as specified and as directed by the Engineer-in-Charge.
Make of Paint: Asian/Berger/Nerolac/Jenson & Nicholson
Note: All the ACs shall be got lettering MES NO., GE (AF) Chabua of appropriate size not less than 1.5 cm.
3
-
-
M&L for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2/3 TR capacity split and window type AC units complete all as specified and as directed by the Engineer-in-Charge.
Make: Siemens/Blue Star/Carrier/LG or any make as approved by the GE.
6
-
-
M&L for taking down the rusted outdoor unit stand and supply & fixing the new stand with anchor fastner, nut & bolts and rubber bushes for 1.5/2 TR split units complete all as specified and as directed by the Engineer-in-Charge.
4
-
-
S&F in repairs, single pole and neutral sheet metal enclosures with a two pin and earth plug and socket 240 V, 50 HZ complete with one single pole MCB 20 A suitable for split/window type ACs complete all as specified and as directed by the Engineer-in-Charge
2
-
-
M&L for complete repair of out door unit of split type AC unit 2TR/3 TR capacity of any make, including taking down all the components, tinkering of the rusted portions, renewal of complete rusted sheet metal parts with the same thickness of MS sheet as per the existing size & shape including cutting, bending, welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning & prepare the surface thoroughly, applying two coats of synthetic enamel paint over a coat of red oxide primer and fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing complete all as specified and as directed by the Engineer-in-Charge.
2
-
-
Material and labour for taking down the burnout / defective scroll type compressor Capacity 20 TR makeunit and repair the factory through OEM replacement of unserviceable worn out parts in the compressor , cleaning the system, compressor winding ,compressor oil ,terminal block,crank case Heater refixing the same in its original position and re connecting all disconnected lines welding /copper brazing etc, in serviceable and operational condation complete all as manufactureres instruction and as directed by Eng-in- charge.including testing and commissioning Carried out through OEM . complete all as specified and directed.
Note :- (i) Leak test , Vacuuming and Refrigerant gas shall be measured separately under relevant items. (ii) Compressor shall have warranty of six months and the contractor is responsible for the maintenance of Compressor during that period.
2
-
-
Supply and fixing controller of hot water generator panel including taking down old and fixing new along with wiring complete all as specified and directed by engr-in-charge(as per existing OEM).
3
-
-
Disconnection ,taking down and dismantling including necessary servicing & testing of dehumidifier of 3 KVA capacity all as specified and directed by engr-in-charge.Note: Necessary parts require for repair shall be measured and paid separetely.
4
-
-
Supply only heating element sutaible for 3 KVA capacity dehumidifer, incl taking down old u/s all as specified and directed by Engr -in-charge.
2
-
-
Supply only thermostate sutaible for 3 KVA capacity dehumidifier , incl taking down old u/s all as specified and directed by engr -in-charge .
3
-
-
Taking down Flood Light fittings of any wattage / any height of pole/ walls/ Garden/Runway any location for repairs or replacement of burnt out the accessories and rectifying the fault of old unserviceable spare with new spares, re-assembling and re fixing in exsting position and connecting with exsting light point all as specified and as directed by the engineer-in-charge.
Note: - LED Drivers, cable ,shall be measured separately under relevant items of this schedule
39
-
-
Supply only Drivers for LED Flood Light Fittings of up to 100W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.
6
-
-
Supply only Drivers for LED Flood Light Fittings of upto 150W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.
8
-
-
Supply only Drivers for LED Flood Light Fittings of upto 250W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.
5
-
-
S&F as in repairs LED flood light fitting, 150 watt with pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires ,sutaible for existing Model dispersal light fitting , including clamp, nut, bolt and other accessories for fixing including cable for connection,incl taking down old u/s complete all as specified and as directed.
8
-
-
S&F as in repairs LED flood light fitting, 200 watt energy saving innovative die aluminium IP 66 in order to ensure better performance of the luminaires sutaible for existing flood light Model, including clamp, nut, bolt and other accessories for fixing including cable for connection incl taking down old u/s complete all as specified and as directed.
6
-
-
S&F as in repairs LED flood light fitting, 250 watt energy saving innovative die aluminium IP 66 in order to ensure better performance of the luminaires sutaible for existing flood light Model, including clamp, nut, bolt and other accessories for fixing including cable for connection incl taking down old u/s complete all as specified and as directed.
6
-
-
M&L for taking down high pressure SV/ MV/ MH /FTL/LED street light fitting and Flood Light fittings of any wattage / any height of pole/ walls/ any location for repairs or replacement of burnt out the accessories and rectifying the fault complete all as specified and directed by Engineer-in-Charge.
Note: - LED Drivers, Surge protection and cable shall be measured separately under relevant items of this schedule
115
-
-
Supply only Drivers for LED Street Light Fittings of 25W / 35W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.
10
-
-
Supply only Drivers for LED Street Light Fittings of 45W / 60W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.
20
-
-
Supply only Drivers for LED Street Light Fittings of 90W / 110W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.
25
-
-
Supply and fixing in repairs LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 45 Watt complete, incl taking down old u/s all as specified and directed by Engineer-in-Charge .
10
-
-
Supply and fixing in repairs LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 60 Watt complete incl taking down old u/s all as specified and directed by Engineer-in-Charge .
10
-
-
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position incl taking down old u/s all as specified and as directed.
4
-
-
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacity incl taking down old u/s all as specified and as directed.
6
-
-
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position incl taking down old u/s all as specified and as directed.
20
-
-
supply and fixing GI bracket fixing in repairs suitable for street light fitting made out of 40mm dia GI tubing of light grade bent to shape of 1.5m length complete including taking out old one complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium Stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core 6 Sqmm cable flat or circular incl taking down old u/s all as specified and as directed .
189
-
-
Disconnecting/taking down unserviceable post top light /Run way light repair/checking and identifying of faulty spares wirings, cleaning of fittings, cover, etc. and re-assembling the same after repairing, testing and refixing in original position and reconnecting with electrical line complete all as specified and as directed. Note : (Spares required will measured and paid under separate item 82 to 88 here in after).labour cost for replacing spare parts to be inclusive in the quoted rate .
25
-
-
Supply only upto 20 W LED Power Driver for post top light all as specified and as directed .
5
-
-
Supply only Upto 40 W LED Power Driver for Post top all as specified and as directed .
8
-
-
Supply only outdoor integral decorative post top lantern luminaire 70 w LED ,IP 65 protection,with aluminium enclosure,powered with high power LEDs as light source and die casted heat with symmetrical light distribution and excellent heat dissipation for long life , sutaible for existing pole dia and three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed.Make : Havells Cat No - JUPITERMAXIPT70WLED757PSYMTOPC or equivalent of CG /Bajaj.
2
-
-
Supply only outdoor integral decorative post top lantern luminaire 40 /45w LED ,ip 65 protection and three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed.
2
-
-
Supply only outdoor integral decorative post top lantern luminaire 20/25 w LED ,ip 65 protection and three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed.
4
-
-
Supply, fixing in Repair and cable junction boxes of size 155mm x 210mm x 92mm IP 66 for cable entry, comprising of SPN aluminium bus bar of capacity 16 Amp 230 Volt fixed , making holes on strips for connecting cables and fixed to garden light pole with and including MS clamp of size 25mmx5mm incl nut ,bolt, washer and and including prvn of MCB SP 6 A, C curve 10kA breaking capacity with mounting rail all as specified and as directed.
4
-
-
Dismantling electrical connection ,Taking down junction box , checking the serviceability including loose contact and condition of cable terminations of all the existing Junction Box ,MCBs Garden Light at any pole, post top lantern, any place once in three months and opening a junction Box / DBs serviceability register and recording location wise complete all as specified and as directed.
Note:- The checking shall be carried out in presence of user/user rep. One time checking including entering in the register is considered as one job.
20
-
-
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trench /poles/on wall, incl taking down old u/s all as specified and as directed
200
-
-
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of FRLS cable etc and getting out in Soft/loose soil complete all as specified and as directed.
50.22
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed
35
-
-
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed
15.22
-
-
Material and labour for sand cushioning for protection of underground FRLS cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid)
15
-
-
M& L for well burnt bricks, sub class B of size 230X113X75 best quality locally available laid flat, dry in trencheches for Cable protection, complete all as directed by Engr-in- charge.
1488
-
-
Drilling of hole horizontaly 80/40 mm dia bellow the road for/Hardstanding providing casing pipe of cable protection by using mechanical/hand drill
8
-
-
Material and labour for galvanized iron tubing 40 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. (Make TATA, JINDAL,Prakash) Note:Excavation ,earth work shall be measured and paid separately
6
-
-
S&F as in repairs for LED aviation obstructing lights IP 40 , 230 V 50 HZ , complete all as specified and as directed.
2
-
-
S&F as in repairs for twin dome LED aviation obstructing lights, IP 40,230 V,50 HZ complete all as specified and as directed.
2
-
-
M&L for taking out burnt winding of 3 phase power tool electric motor of high mast fittings from any position, re-winding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning on reinstating complete all as specified and as directed.
Note : Quoted rate shall be deemed to be inclusive of any minor spares/parts.
2
-
-
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?