Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666255_1Bid Award Id
ViewTender No
8837/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per Item No. 03 here-in-above, but for 25mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
90
-
-
All as per Item No. 03 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
110
-
-
All as per Item No. 03 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
160
-
-
All as per Item No. 03 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
116
-
-
All as per Item No. 03 here-in-above, but for 63mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
110
-
-
All as per Item No. 03 here-in-above, but for 90mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
110
-
-
All as per Item No. 03 here-in-above, but for 110mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
130
-
-
Labour only for laying/fixing of serviceable GI/PP-R pipe of any type of 20mm dia for hot & cold water supply with all fittings laid in trenches/ fixed to wall including taking down the existing CI/GI/PP-R pipe, cleaning the same for re-use and testing, complete all as specified and as directed by Engineer-in-charge.
40
-
-
All as per Item No. 11 here-in-above, but for 25mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
90
-
-
All as per Item No. 11 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
60
-
-
All as per Item No. 11 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
80
-
-
All as per Item No. 11 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
90
-
-
All as per Item No. 11 here-in-above, but for 80mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
70
-
-
All as per Item No. 11 here-in-above, but for 100mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
60
-
-
S&F in-repair of 25mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
12
-
-
S&F in-repair of 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F in-repair of 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F in-repair of 63mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
6
-
-
S&F of 25 mm bore (dia), gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 and including taking out old unserviceable gate valves complete all as specified and as directed by Engineer-in-charge.
10
-
-
All as per Item No. 22 here-in-above, but for 40mm dia gun metal gate valves, complete all as specified and as directed by Engineer-in-charge.
4
-
-
All as per Item No. 22 here-in-above, but for 50mm dia gun metal gate valves, complete all as specified and as directed by Engineer-in-charge.
4
-
-
M&L for repairing of sluice valve of 100mm dia by replaceng GI Spindle, CI gate mechanical sealing, complete all as specified and as directed by Engineer-in-charge.
2
-
-
M&L for repairing of sluice valve of 150mm dia by replaceng GI Spindle, CI gate mechanical sealing, complete all as specified and as directed by Engineer-in-charge.
2
-
-
Supply & Fixing, jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 80 mm bore (Internal Dia) confirming to IS 14846-2000, flanged ends drilled having brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves, complete all as specified and as directed by Engineer-in-charge.
4
-
-
All as per Item No. 27 here-in-above, but for 100mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
6
-
-
All as per Item No. 27 here-in-above, but for 150mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
2
-
-
Supply & Fixing, jointing and testing of cast iron Non Return Valve (NRV) ISI mark (PN-1.6) of size 80 mm bore, without bypass arrangement, swing type, conforming to IS-5312, complete with nuts, bolts, washers and gaskets including taking out old unserviceable NRV, complete all as directed by Engineer-in-charge.
1
-
-
All as per Item No. 30 here-in-above, but for 100mm dia cast iron Non Return Valve (NRV) ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
1
-
-
M&L for Making connection of PP-R distribution branch with PP-R main of 16-40mm dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed by Engineer-in-charge.
6
-
-
M&L for Making connection of PP-R distribution branch with PP-R main of 50-75mm dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed by Engineer-in-charge.
6
-
-
M&L for Cutting and Screwing existing 80-100mm dia steel tubing for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and as directed by Engineer-in-charge.
4
-
-
M&L for construction of Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 150mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally upto full depth and externally upto 150mm below GL, providing 3mm thick MS black Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as directed by Engineer-in-charge.
4
-
-
All as per Item No. 35 here-in-above, but for 600mm X 600mm X 600mm (Internal dimension) valve pit, complete all as specified and as directed by Engineer-in-charge.
3
-
-
S&F in-repair of rubber packing sheet of 6mm thick, complete all as specified and as directed by Engineer-in-charge.
12
-
-
M&L for Overhauling of centrifugal/monoblock pump set of capacity 15HP to 30 HP after removing from base plate disconnecting from pipe line and dismantling pump set, replacing US gland packing, gun metal bush, bearing and water seal and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts and new gasket including dismantling the motor, cleaning the rotor, starter, varnishing, backing etc and reassembling the motor and painting motor and pump sets including suction and discharge pipe line with one coat of paint with spray painting also connecting the existing cable etc. including testing the pump set for full satisfaction of in-charge complete all as specified and directed .Note: 1. Defective major components/spares if required to be replaced shall be measured as supply only under respective item here-in-after and labour element included in item No 38 for replacement of major spares/components.
2
-
-
Supply only Ball bearings any type suitable for pump set of capacity 15HP to 30 HP
1
-
-
Supply only CI Impeller any type suitable for pump set of capacity 15HP to 30 HP
2
-
-
Supply only Shaft stainless steel along with key and check nut of any type suitable for pump set of capacity 15HP to 30 HP
1
-
-
Supply only Oval flange bearing unit of any type suitable for pump set of capacity 15HP to 30 HP
4
-
-
Supply only Rubber coupling of any type suitable for pump set of capacity 15HP to 30 HP
4
-
-
S&F in-repair of motor ball bearing as per existing suitable for motor upto 50 HP, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F in-repair of pump ball bearing as per existing suitable for motor upto 50 HP, complete all as specified and as directed by Engineer-in-charge.
4
-
-
M&L for overhauling and repair of decrine dosing pump and replacement of the unserviceable components of decrine dosing pumps if required of existing make, complete all as specified and as directed by Engineer-in-charge.
Notes:- Spare Parts shall be measured and paid separately.
2
-
-
Supply only Ball ceramic (Part No 21449) of dosing pump.
2
-
-
Supply only Ring seal viton (Part No 013166) of dosing pump.
2
-
-
Supply only Spring (Part No 48452) of dosing pump.
3
-
-
Supply only Suction valve seat (Part no 013678) of dosing pump.
3
-
-
Supply only Anti syphon valve.
3
-
-
Supply only Special function valve (Part No 280803).
3
-
-
Supply only Low level switch (Part No. 270803).
2
-
-
Supply only Diaphrgam (Part No 41027).
2
-
-
Supply only discharge valve housing (Part No 41027).
2
-
-
Supply only foot valve assembly (Part No 17078).
2
-
-
Supply only Head (Part No 011779).
2
-
-
Supply only discharge pipe 8 mm dia
30
-
-
M & L for cleaning of PS/RCC OHT of any capacity through 6 stage (Mechanized Dewatering, Sludge Removal, High Pressure Cleaning, Vaccum cleaning, Antibacterial spray, UV radiation through govt authroized farm for cleaning overhead tank and sumps) cleaning process by involving the following six stages of cleaning processes and all as directed by the Engineer-in-Charge.
(i) Suitably blocking the incoming and outgoing and wash out pipes for avoiding mud and foreign materials deposited in the reservoir getting in to pipes and chocking it prior to starting the cleaning.
(ii) De-watering by high pressure German submersible pump all as complete
(iii) Total removal of sludges by German suction pumps all as complete
(iv) Cleaning of walls, ceiling & floor by high pressure German jet of 80 - 180 bar pressure all as complete
(v) Removal of all dirt particals and sludge by vacuum pump specially designed all as complete
(vi) Disinfect the tank with FOA/WHO specified chemical and make the tank totally bacteria free.
(vii) Sterilization of tank completely atmosphere by industrial ultra-violet radiation leaving the tank completely sterilized all as complete
(viii) Remove the blockage from inlet/outlet/over flow pipes, refill the tank with water and supply water at supply timings ensure satisfactory distribution
750
-
-
All as per serial item No 59 here-in-above but for Semi-underground sump of any capacity, complete all as specified and as directed by Engineer-in-charge.
500
-
-
M&L for preparation of external surfaces of pressed steel sheets including angle iron Staging, tie bars, stair, rising, delivery, over flow and wash out pipe line complete of PS Over head tank of 45000 Ltr capacity and applying one coat of synthetic enamel paint same as existing colour, complete all as specified and as directed by Engineer-in-Charge.
8
-
-
S&F in-repair of PVC insulated three core sheathed submersible flat cable of size 10 Sqmm for submersible pumps with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
90
-
-
Supply and lowering of MS column pipe of 10 feet long both side flange, duly welded flange heavy duty 'C' grade of size 80 mm dia including nuts, bolts, washer and gasket etc complete all as specified and diredted. Make: TATA/Bansal/Jindal
4
-
-
M&L for mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
0.65
-
-
M&L for overhauling and repair of 3 Phase, submersible pump set of any make and of capacity 10 HP to 20 HP by disconnecting electrical/ mechanical connections and taking out pump from existing bore well with all accessories such as column pipe etc and transporting to authorized workshop to carry out repair work including replacement of minor unserviceable components/spares like nuts, bolts, washer & the like and reassemble all the parts/portions and refix at same position, including re-lowering in same bore well with all accessories, reconnecting and making connection with starter including re-commissioning and testing to ensure efficient and smooth functioning to obtain required discharge, etc complete all as specified and directed.
Note: 1. Defective major components/spares if required to be replaced shall be measured as supply only under respective item here-in-after and labour element included in item No 04 for replacement of major spares/components.
2
-
-
Supply only stainless steel shaft for submersible pump of capacity 10 to 20 HP as per sample.
2
-
-
Supply only gun metal impeller suitable for submersible pump of capacity 10 to 20 HP as per sample.
2
-
-
Supply only stainless shaft sleeves for submersible pump of capacity 10 to 20 HP as per sample.
2
-
-
Supply only CI intermediate/suction/discharge case suitable for submersible pump 10 to 20 HP capacity and as per sample.
2
-
-
Supply only Stainless Cable guard forsubmersible pump 10 to 20 HP capacity and as per sample.
2
-
-
Supply only Stainless Suction strainer for submersible pump 10 to 20 HP capacity and as per sample.
2
-
-
Dismantling the submersible pump motor of 10 to 20 HP for re-winding the electric motor with super enamelled copper winding wire of same gauge including impregnated paper, sleevs, lathorised fibre glass, varnish and tape, etc incl transporting to authorized workshop to carry out repair work complete all as specified and directed. (Note :- Major spares if required will be paid under respective items mentioned below as supply only)
2
-
-
Supply only Key for motor coupling
2
-
-
Supply only CI clip thrust bearing locking part
2
-
-
Supply only Pin for motor base part
2
-
-
Supply only Pin for thrust bearing
3
-
-
Supply only Cable clip for motor
3
-
-
Supply only Cable seal rubber
2
-
-
Supply only Gasket
2
-
-
Supply only Stud for upper flange stainless steel
2
-
-
Supply only Stud for lower flange
2
-
-
S&F in replacement, ball bearing as per existing No/size 6201/6202/6203 complete all as specified and directed.
50
-
-
S&F in replacement rubber real insulator of suitable size complete all as specified and directed.
60
-
-
S&F in replacement capacitor of cap 3.15 MFD complete all as specified and directed.
200
-
-
M&L for Taking down and refixing at site ceiling fans 1200mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying , replacement of condenser, ball bearing etc and re-assembling the same including necessary transportation etc complete all as specified and directed.
125
-
-
M&L for Taking down and refixing at site Exhaust fan of 380/450mm sweep including opening of fans and cutting down burnt winding, and re-winding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of condenser, ball bearing etc and re-assembling the same including necessary transportation etc complete for all as specified and directed.
10
-
-
M&L for Taking down and refixing at site Exhaust fan of 230/250mm sweep including opening of fans and cutting down burnt winding, and re-winding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of condenser, ball bearing etc and re-assembling the same including necessary transportation etc complete for all as specified and directed.
10
-
-
Taking out/down water heater of any type and capacity at different units and servicing of the same incl cleaning heating element, water pipe, checking of electrical connections, and checking of NRV , safety valve/air release valve etc and refixing of the same after servicing , connecting with inlet and out let water connection and electrical connection and testing complete all as specified and directed.
20
-
-
S&F in replacement of flexi connection pipe accessory 450 mm for water heater any type/capacity complete all as specified and directed
20
-
-
S&F in replacement of heating element of Tricone type of capacity 1500W in any type of electric water heater complete all as specified and directed.
10
-
-
S&F in replacement of heating element of Cup type of capacity 1500W in any type of electric water heater complete all as specified and directed.
8
-
-
M&L for taking down by opening all electric & water supply connections of solar water heater of any type and of capacity upto 100 LPD for servicing/replacing to u/s spares/ carrying out neccessary repairing works by cleacning internal tubes, removing sludge, and refixing back by connecting all connections complete all as directed.
2
-
-
M&L for taking down by opening all electric & water supply connections of solar water heater of any type and of capacity above 100 LPD to 300 LPD for servicing/replacing to u/s spares/ carrying out neccessary repairing works by cleacning internal tubes, removing sludge, and refixing back by connecting all connections complete all as directed.
3
-
-
S&F in replacement of heating element of capacity 3000W in Hexagonal thread type suitable of solar water heater complete all as specified and directed.
8
-
-
S&F in replacement of thermostate in replacement suitable for water heater of any type/size complete all as specified and directed.
30
-
-
M&L for taking out u/s air conditioner window/ split type in cappacity 1.5 and 2.0 Ton for replacing to u/s spares /servicing/ carrying out neccessary repairing works/gas re-filling etc in any type/ cap/ make /model including removing all connections safely and refixing after repairing work complete all as directed.
24
-
-
S&F in repair/replacement of thermatically sealed new compressor for air conditioner of 1.5/2.0 TR including connection of all pipe line & changing of refrigerant and testing complete all as specified and directed by Engr-in-charge.
8
-
-
Supply & charging only of refrigerant R-22 to Air conditioner of any type, make and capacity complete all as specified and as directed.
18
-
-
Supply & fixing PCB card suitable for AC any type or size in replacement complete all as specified and directed.
8
-
-
S&F in-repair of Electric fan motor, AC 230 volt, single phase with recommended RPM etc suitable for AC complete all as specified and directed.
6
-
-
S&F in-repair of starting capacitor 100-120 MFD for AC any type of capacity 1.5/2.0 TR complete all as specified and directed.
16
-
-
S&F in-repair of running capacitor 45 MFD for AC any type of capacity 1.5/2.0 TR complete all as specified and directed.
12
-
-
S&F in-repair of relay for AC of capacity 1.5/2.0 TR complete all as specified and directed.
10
-
-
S&F in-repair of over load protector for AC of capacity 1.5/2.0 TR complete all as specified and directed.
12
-
-
S&F in Repair/Replacement of condensor for AC of capacity 1.5/2.0 TR complete all as specified and directed.
4
-
-
S&F in Repair/Replacement of capillary tube set for AC of of capacity 1.5/2.0 TR complete all as specified and directed.
5
-
-
S&F in Repair/Replacement of cooling coil for AC of capacity 1.5/2.0 TR complete all as specified and directed.
4
-
-
S&F in Repair/Replacement of selecter switch for AC of capacity 1.5/2.0 TR complete all as specified and directed.
6
-
-
S&F in Repair/Replacement of thermostat for AC of capacity 1.5/2.0 TR complete all as specified and directed.
10
-
-
S&F in-repair of indoor wall mounting unit of split type air conditioners electric driven single Phase of capacity of 1.5 TR with minimum 3 star rating EER 3.2, noise Level 39 DB complete all as specified and directed. Make- Voltas/LG/ Sumsang
3
-
-
S&F in repair/replacement of thermatically sealed new compressor for water cooler of 40/80 ltr/hr cooling capacity including connection of all pipe line and testing complete all as specified and directed.
6
-
-
Supply and charging only of suitable refrigerant gas to water cooler of any type, make and capacity complete all as specified and directed.
12
-
-
S&F in repair/replacement of starting capacitor 80/100 MFD for water cooler 40/80 ltr cooling capacity complete all as specified and directed.
12
-
-
S&F in repair/replacement of running capacitor 10 MFD for water cooler 40/80 ltr cooling capacity complete all as specified and directed.
12
-
-
S&F in-repair of thermostate for water cooler of any type & capacity complete all as specified and directed.
10
-
-
S&F in-repair of float valve set for water cooler of any type & capacity complete all as specified and directed.
6
-
-
Repair and Replacement of fan motor for water cooler of 40/80 cooling capacity complete all as specified and directed.
4
-
-
S&F in repair/replacement of thermatically sealed new compressor for refrigerator of capacity 320 ltr including connection of all pipe line and testing complete all as specified and directed by Engr-in-charge.
4
-
-
Supply and charging only of suitable refrigerant gas to refrigerator of any type, make and capacity complete all as specified and directed.
10
-
-
S&F in-repair of fan motor for refrigerator 320 ltr cooling capacity complete all as specified and directed.
4
-
-
S&F in-repair of relay set for Refrigerator of any capacity upto 320 ltrs complete all as specified and directed.
6
-
-
S&F in-repair of chiller tray for Refrigerator any type any capacity complete all as specified and directed.
6
-
-
S&F in-repair of vegitable tray for Refrigerator any type any capacity complete all as specified and directed.
6
-
-
S&F in-repair of evaporator for Refrigerator any type any capacity complete all as specified and directed.
3
-
-
S&F in repair and Replacement of copper tubing 3/16" for AC any type any capacity complete all as specified and directed.
16
-
-
S&F in repair and Replacement of copper tubing 1/4" for AC any type any capacity complete all as specified and directed.
20
-
-