Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665639_1Bid Award Id
ViewTender No
GE(N)/TEZ/2024-2025/8960Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
110
-
-
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges.
10816
-
-
Taking out the existing ACSR Conductor /PVC/XLPE, 1100 volts grade, LT UG electric cable of any size and any type in trenches/ walls/ overhead lione (or) passing through pipes/in floor complete all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items:-
1690
-
-
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 25 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
50
-
-
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 35 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
65
-
-
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 50 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
45
-
-
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 70 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
35
-
-
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
25
-
-
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
350
-
-
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 35 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
320
-
-
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 50 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
285
-
-
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 70 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
265
-
-
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
250
-
-
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for 25 to 50 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
6
-
-
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
8
-
-
Supplying & laying in repair 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
60
-
-
Supplying & laying 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
50
-
-
Supplying & laying in trenches 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
40
-
-
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
20
-
-
M&L for painting of erected steel tubular swaged poles of LT over head line (Except embedded protion), 9 M long complete including all MS mounted/fixed with pole, earth protection & water pipe (if exists) with one coat of aluminium paint and providing 07 Nos bands/ straps with synthetic enamel paint (black and yellow 30 cm wide each) from top of plinth block and numbering of poles with black synthetic enamel paint on circular yellow background of complete all specified.
165
-
-
Taking out the existing LT pole of any size and any type complete all as specified and directed by the Engr-in- charge
6
-
-
Supply & erecting steel tubular swaged pole type 410-SP-55 (11.0 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surafaces of steel tubular poles with two coats of Aluminium paint over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.complete all as specified and as directed.(Exixting Connection two pole structure to four pole structure at Thakurbari Subs staion 1 &2 ,Phulbari ss)
6
-
-
Re Fixing for Steel tubular swaged poles any type and any size after taking dwon with proper shut dwon without damage for pole any location within 100 mts complete including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surafaces of steel tubular poles with two coats of Aluminium paint over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.complete all as specified and as directed.
12
-
-
M&L danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colo dismantling unserviceable one, complete all as specified and as directed .
60
-
-
Road cutting for passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core. Complete all as specified and directed
3
-
-
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
4
-
-
M&L for Cleaning of electric substation by uprooting unwanted grass, bushes and trimming of branches, surface dressing not exc.15cms deep in loose/soft soil to cut the grass,throne busehs and other any type of grass upto root level surrounding the installation and depositing the same at nearby garbage pit, refreshing and re-spreading aggregates inside the premises of sub station if any including cleaning of road/path/fencing etc, maintenance of transformer platform all as specified and directed.
600
-
-
Trimming of tree branches touching to LT / HT OH lines not exceeding 30 cm girth, shrub, vegetaion, bush and saplings at least upto 5.0 M from outer edge of ACRS including cleaning of road/path/fencing etc. complete all as specified and directed.
4000
-
-
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chromium and two coats of synthetic enamel paint all as specified.
6
-
-
Dismantling insulators any type, any size including setting aside serviceable and removal of rubbish material complete all as specified and directed.
135
-
-
S&F (in repair) Insulator Pin type, povrcelain, vitreous, white, brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washres and one glavanised iron nut, 100 mm height, 65 mm die. For 1100 volts grade complete all as specified.
60
-
-
S&F (in repairs) insulator shackle type, Porcelain vitreous, white, brown, white or green including, galvanised mild steel straps washers, insulator bolts, washers and nuts, 100 volts working pressure, 75mm height, 90 mm Maximum dia with 31x3 mm galvanised steel straps and dia of bolt 12 mm complete all as specified.
75
-
-
Dismantling stay assembly complete all as specified and as directed.
10
-
-
M&L (in repairs) for Stay Assembly comprising of 7/2.24mm galvanised MS stranded wire of rquired length fixed to pole with and including flat iron clamps fabricated out of 50x6mm flat iron and nuts,bolts & washers of suitable size, 40cms long 14mm dia galvanised MS stay bow, 215cms long 20mm dia stay rod with threaded end including bolts & washers, MS stay plate galvanised 230x230x6mm, two thimbles,loop type insulator of size 65x90mm with clearance dia of hole 20mm including necessary excavation, earth work and PCC 1:4:8 type D2 using 40mm stone aggregate complete all as specified and directed.
10
-
-
M & L in repais Loop type insulator, small size, with overall dimensions 90 mm X 65 mm, cable hole dia 16 mm, creepage distance 41 mm, minimum failing load 44000 N, vitreous porcelain, white, brown or green, Designation A as per IS 5300: 1969 complete all as specified and as directed.
6
-
-
Dismantling of ACSR conductors of any description and to be replaced by XLPE UG cable. XLPE cable shall be paid under relevant items in this BOQ all as specified and directed by Engineer- in- charge.
25
-
-
Supplying, straining and stretching of Over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and coloured sleeved jumpers with jumper connections with PG clamps complete all as specified.
25
-
-
Restreching only existing LT OH/ HT OH lines consisting 2 conductor to 8 conductor of ACSR lines 1 line of GI wire, any size and tightening with aluminium binding wire of suitable size complete all as specified and directed.
7500
-
-
Dismantling earth wire or copper conductor, service feeder or distributor span removing to store or taken on schedule of credit complete all as specified and as directed.
2
-
-
S&F (in repairs) guarding Cradles, hexagonal/ rectangular,fabricated with galvanised steel wire 4 mm dia on LT pole including binding with 14SWG MS wire complete all as specified and directed.
2
-
-
S&F (in repairs) earth wire LT poles including clip and other accessories with fabricated with galvanised steel wire 4 mm dia 14SWG MS wire complete all as specified.
2
-
-
Taking down for service connection any type and any size complete all as specified and as directed.
1000
-
-
Supply and fixing or connecting service cable 2 core 16 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
200
-
-
Supply and fixing or connecting service cable 2 core 10 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
400
-
-
Supply and fixing or connecting service cable 2 core 6 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
400
-
-
Taking down for line separator any type and any size complete all as specified and directed.
150
-
-
M&L for line separator 4 way PVC type with clamp including fixing with overhead lines of multi conductor of ACSR as and where directed to prevent short circuiting of phase/neutral conductors mutually complete all as specified and directed.
85
-
-
M&L for line separator 2 way PVC type with clamp including fixing with overhead lines of multi conductor of ACSR as and where directed to prevent short circuiting of phase/neutral conductors mutually complete all as specified and directed.
65
-
-
M & L for writing letters and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel/RCC surfaces of electric poles.
25
-
-
S& F for GI earthing strip 25x4 mm with nut and bolts comoplete including taking down old one all as specified and directed by Engr- in- Charge
215
-
-
S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,buried in ground including excavation complete all as specified and directed by Engr-in-Charge.
185
-
-
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion.
Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
7
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.