Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date19 Nov 2024
Closing Date24 Dec 2024
Tender Amount₹ 1,10,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 39,03,451.78 inserted by the MES in Schedule ‘A’ Part-II.

1

-

-

... More
INTERNAL WATER SUPPLY (Sch 'A' PART-III)

-

-

-

... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 52,58,866.28 inserted by the MES in Schedule ‘A’ Part-III.

1

-

-

... More
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,17,67,684.40 inserted by the MES in Schedule ‘A’ Part-IV.

1

-

-

... More
ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V)

-

-

-

... More
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,39,02,871.00 inserted by the MES in Schedule ‘A’ Part-V.

1

-

-

... More
SEWAGE DISPOSAL (Sch 'A' PART-VI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 28,27,973.03 inserted by the MES in Schedule ‘A’ Part-VI.

1

-

-

... More
AREA DRAINAGE (Sch 'A' Part-VII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 37,29,719.29 inserted by the MES in Schedule ‘A’ Part-VII.

1

-

-

... More
EXTERNAL WATER SUPPLY (Sch 'A' Part-VIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 8,27,538.00 inserted by the MES in Schedule ‘A’ Part-VIII.

1

-

-

... More
EXTERNAL ELECTRIFICATION (Sch 'A' PART-IX)

-

-

-

... More
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,00,82,750.82 inserted by the MES in Schedule ‘A’ Part-IX.

1

-

-

... More
FIRE FIGHTING (Sch 'A' Part-X)

-

-

-

... More
Lump sum price worked out by the Contractor for “(FIRE FIGHTING)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 45,98,698.13 inserted by the MES in Schedule ‘A’ Part-X.

1

-

-

... More
STP (Sch 'A' Part-XI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(STP)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 15,57,138.06 inserted by the MES in Schedule ‘A’ Part-XI.

1

-

-

... More
LIGHTNING PROTECTION & DG SET (Sch 'A' Part-XII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION AND DG SET) ” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 5,21,128.90 inserted by the MES in Schedule ‘A’ Part-XII.

1

-

-

... More
LIFT (Sch 'A' Part-XIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,50,64,975.70 inserted by the MES in Schedule ‘A’ Part-XIII.

1

-

-

... More
AVIATION OBSTRUCTION LIGHT (Sch 'A' Part-XIV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(AVIATION OBSTRUCTION LIGHT)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 44,646.95 inserted by the MES in Schedule ‘A’ Part-XIV.

1

-

-

... More
TELE/TV SOCKET (Sch 'A' Part-XV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(TELE/TV SOCKET)” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,13,408.80 inserted by the MES in Schedule ‘A’ Part-XV.

1

-

-

... More
CHAIN LINK FENCING (Sch 'A' Part-XVI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING)” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 9,28,684.57 inserted by the MES in Schedule ‘A’ Part-XVI.

1

-

-

... More
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XVII)

-

-

-

... More
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved Earth may be mixed with granules / pebbles not exceeding 40 mm size (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed. NOTE :- (a) Earth required for the item shall be supplied by contractor from outside of MOD land at any lead, at his own arrangement. (b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level. (d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page No. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk. (e) Total quantity / partial quantity of earth may not be available in Sevoke Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved.

10630

-

-

... More
INTERNAL WATER SUPPLY S & F 15 mm health faucet, chromium plated, fancy type with 1.0 m steel flexible complete suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM

348

-

-

... More
S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM

348

-

-

... More
S & F swivel shower with arm of 15 mm dia, 195 mm long with bend of 45 degrees with flange of fancy type, chromium plated, screwed down and fixed suitable for 15 mm inner dia pipe complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM

348

-

-

... More
INTERNAL ELECTRIFICATION S&F Modular type 3/5 pin socket including plug top 16 A controlled by switch 16A including sheet metal enclosure suitable for Geyser point complete all as specified and directed.

184

-

-

... More
Supply and fix 5 watt LED lamp capable to output 501 lm with lamp holder B22 type complete all as specified and directed.

913

-

-

... More
S & F TPN DB 6 way (vertical type), IP43 with acrylic door as per IEC 61439-3 sitable for flush/surface mounting with 100Amp fully insulated Copper Busbar for each phase with 2 shrouded Neutral bar, 2 Earth bar and cable ties, prefitted masking sheet, reversible Door with provision for FP MCB/RCBO as incommer and SP/SPN MCB's as outgoing without MCBs complete all as specified and directed.

5

-

-

... More
S&F SPN DB with sheet metal enclosure 240 volts 6 way, single phase, double door with copper bus bar neutral link, earth link, earthing studs without MCBs complete all as specified and directed.

10

-

-

... More
S&F Hot press molded SMC meter box of size not less than 700mm X 480mm x 210mm for accommodating 04 nos of single/three phase prepaid energy meter including cutting the wall surfaces for flush mounting of meter box and making good to match with the existing surface complete all as specified and directed.

41

-

-

... More
SEWAGE DISPOSAL Supply, laying, jointing and testing of 150mm internal diameter of double wall corrugated (DWC) high density polyethylene pipe (HDPE) and stiffness classes -8 (SN-8) with ISI marked (with CML no) and including all fitting of pipe & jointing material for sewage line and laid in trenches all as specified in IS -16098-2013 part-2 complete all as specified and directed.

776

-

-

... More
AVIATION OBSTRUCTION LIGHT Supply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed. (Make Bajaj Cat No BGAV 302 LED or equivalent Make mentioned in list of products. )

5

-

-

... More
Supply and fix MCB SPN 6-32 Amps, 10 KA, 'C' curve complete all as specified and directed.

5

-

-

... More
TELE/TV SOCKET Supply and fix TV socket 1 module complete all as specified and directed.

328

-

-

... More
Supply and fix Tele socket 1 module complete all as specified and directed.

40

-

-

... More
Supply and fix inner and outer modular cover plate of 1/2 M complete all as specified and directed.

368

-

-

... More
EXTERNAL WATER SUPPLY Supply, jointing and laying in trenches in standard lenght, centrifugally cast (spun) ductile iron (Dl) pressure pipes, S/S type, 150 mm dia with inside cement mortar lining and black bitumen external coating, nominal daimeter, class K-7 classification, confirming to IS-8329 (ISI marked), including push on and rubber gasket joints and jointing including testing complete all as specified and directed.

950

-

-

... More
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia complete all as specified and directed.

1

-

-

... More
Supply and fix Monoblock pump set suitable for 415 V, 3 phase system having capacity 15 HP, 40 mtr head complete all as specified and directed.

6

-

-

... More
M&L for construction of valve pit of internal size 120 cm x 120 cm x 100 cm with one brick thick brick masonary wall in cement mortar (1:4) PCC foundation 15 cm thick (1:4:8) type D-2 with 15 cm offsets, PCC copping 5 cm thick (1:2:4) type B-1, plastering 15 mm thick in cement mortar (1:4), 40x40x6mm angle iron frame and 3mm thick MS sheet cover with locking arrangement including painting to steel surfaces wtih two coats of synthetic arrangement including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation and earth work complete all as specified and directed.

5

-

-

... More
Labour only for cutting of CI/DI/GI pipe 100 to 200 mm dia carefully in position for repairs or inserting fittings such as valve, bend, tee, socket pieces, collar etc complete all as specified and directed.

2

-

-

... More
Material and labour for horizontal boring under roads/path for insertion of pipes upto 200 mm bore by manual drilling complete all as specified and directed.

25

-

-

... More
Factory made and CPRI tested indoor type Floor mounted self supporting. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-65 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process. The panel shall be front openable type adequate space all around cessories such as LT switch gear and metering instruments including internal wiring in the panel with FRLS non flamable insulated multi stranded/ solid copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories. (i) INCOMING (a) MCCB 415 Volts,32-63 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 16 kA 1 Nos. (b) Digital multi function meter (V,A,Hz,Pf) with and including resin cast CTs - 01 Set. (c) Phase indicating lamp(set of 3). (II) OUTGOING (a) MCB 415 Volts,32 Amp , rating 3 Pole, (Service Breaking Capacity 10 kA)- 02 No. (b) Star delta starter suitable upto 15 Hp auto starter pump set-02 No (as per pump capcity) (b) Internal wiring of panel with stranded copper cable of suitable size (c) LED indicating lamp(Set of three)-01 Set (d) All standard relays and contactors to make the motor and pump operational in auto, manual and test mode including power cable from control panel to motor. Note: Scope of work also includes un foreseen items such as laying / passing of cable through walls/ floors/ pipes over/ beneath the surface, drilling holes core cutting etc are deemed to be included in unit quoted rate.

1

-

-

... More
EXTERNAL ELECTRIFICATION Material and labour for horizontal boring under roads/path for insertion of pipes upto 100 mm bore by manual drilling complete all as specified and directed.

30

-

-

... More
Supply and fix junction box made out of polycarbonate with IP 55/1P 66 protection of suitable size including - 04 Nos cable terminal, 02. Nos polycarbonate cable gland, 01 Nos DIN rail and 01 No. MCB SP. 10 KA 6 Amps incl 01 pair of clamp made out of MS flat 25 X 3 mm, nuts bolts and washers incl painting of clamps and nuts, bolts and washers with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.

20

-

-

... More
M&L for street light bracket made out of 32 mm dia GI pipe light grade 1.2 mtr long cut to size and to shape, fixing to steel tubular swaged LT poles with flat iron clamps of size 40X6mm 02 sets incl nuts, bolts and washers incl two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed

20

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 1200 amps three phase and neutral suitable capacity marked RED,YELLOW, BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed :- Item Contined as Ser No. 17.27

1

-

-

... More
(a) 1200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b)Incommer - ACB 4 pole, 800 Amps, breaking capacity 65 kA. - 01 nos (c) OutgoingMCCB 4 pole,400 Amps, breaking capacity 50 kA - 02 Nos (1 x Offr Md Accn Panel + 1 x Spare) (d) Outgoing- MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 04 Nos (2 x JCO Md Accn Panel + 1 x DG Panel + 1 x Spare (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. - 05 Nos (g) Digital frequency meter 50 Hz - 01 No (h) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) PCC Foundation

-

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 400 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :- Item Contined as Ser No. 17.29

1

-

-

... More
(a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incomer - MCCB 4 pole, 200 Amps, breaking capacity36 kA.- 01 Nos (c) Outgoing - MCCB 4 pole, 63 Amps, breaking capacity 16 kA . - 03 Nos (2x W/S pump panel through stabilizer + 1x spare) (d) Outgoing - MCCB 4 pole, 32 Amps, breaking capacity 16 kA . - 14 Nos ( 2x Offr Md Accn Lift + 6x JCO Md Accn Lift + 3 X Fire pump Panel + 1x street light + 2x Spare) (e) Outgoing - MCB SPN, 16 Amps, breaking capacity 10 kA . - 08 Nos ( 3x stair case + 3x Common Area + 1 x aviation light + 1x Spare) (f) Street light timer switch -01 Nos (g)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos (h) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. - 01 Nos (j) Digital frequency meter 50 Hz.-01 Nos (k) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (l) PCC Foundation

-

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 400 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :- Item Contined as Ser No. 17.31

1

-

-

... More
(a) Incomer - MCCB 4 pole, 200 Amps, breaking capacity 36 kA.- 01 Nos (b) Outgoing - MCCB 4 pole, 63 Amps, breaking capacity 16 kA . - 03 Nos (2x W/S pump panel through stabilizer + 1x spare) (c) Outgoing - MCCB 4 pole, 32 Amps, breaking capacity 16 kA . - 13 Nos ( 2x Offr Md Accn Lift + 6x JCO Md Accn Lift + 3 X Fire pump Panel + 1x street light + 2x Spare) (d) Outgoing - MCB SPN, 16 Amps, breaking capacity 10 kA . - 04 Nos (2x stair case + 2x Common Area + 1 x aviation light + 1x Spare) e) Street light timer switch -01 Nos (f)Three Ph Digital Volt Meter(0-500)Volt with selector switch. - 01Nos (g) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. - 01 Nos (h) Digital frequency meter 50 Hz.-01 Nos (j) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (k) PCC Foundation

-

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 600 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :- Item Contined as Ser No. 17.33

1

-

-

... More
(a) 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer -MCCB 4 pole,400 Amps, breaking capacity 50 kA.- 01 Nos (c) Outgoing - MCCB 4 pole, 125 Amps, breaking capacity 25 kA.- 06 Nos (1x Each Floor - 05 Nos + 1x Spare) (d)Three Ph Digital Volt Meter(0-500)Volt with selector switch.- 01Nos (e) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch.- 01 Nos (f) Digital frequency meter 50Hz.01 No (g) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (h) PCC Foundation.

-

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 300 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :- Item Contined as Ser No. 17.35

2

-

-

... More
(a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer - MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 01 Nos (c) Outgoing - MCCB 4 pole,63 Amps, breaking capacity 16 kA.- 07 Nos (1x Each Floor - 06 Nos + 1x Spare) (d)Three Ph Digital Volt Meter(0-500)Volt with selector switch.- 01Nos (e) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch.- 01 Nos (f) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (g) PCC Foundation.

-

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 1000 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge : Item Contined as Ser No. 17.37

1

-

-

... More
(a) 1000 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b)Incommer - ACB 4 pole, 800 Amps, breaking capacity 50 kA, - 01 Nos (c) OutgoingMCCB 4 pole, 200 Amps, breaking capacity 36 kA.- 05 Nos (4x OR Md Block + 1x Spare. (d) OutgoingMCCB 4 pole, 200 Amps, breaking capacity36 kA. - 02 Nos (1x DG Panel + 1x Spare) (e)Three Ph Digital Volt Meter(0-500)Volt with selector switch..- 01Nos (f) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch. - 01 Nos (g) Digital frequency meter 50 Hz - 01 No. (h) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (l) PCC Foundation .

-

-

-

... More
Supply, Installation, testing and commissioning of LT panel board outdoor cubicle type suitable for 3 phase , 4 wire 415 volt 50 Hz factory fabricated CPRI type tested powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 50x50x6mm frame with front and back openable double door system with locking arrangement louver and air vent gasket for natural air flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arrangements with aluminium bus bar of cap 300 amps three phase and neutral suitable capacity marked RED,YELLOW,BLUE and BLACK insulators, made of high strength insulated materials 1100 voltage, bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity, lifting lugs (02 Nos) ,arrangement to be connect earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The panel should be chemically treated with 07 tank metal treatment process for anticorrosive treatment. The panel shall be completely dust and vermine proof and degree of protection not less than IP-55 and general construction confirming to IS -1347 epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire not less than 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. All internal connection should be made by using copper strip/wire of suitable size and provision cable entry/exit shall be provided at the bottom / side of the panel for both incoming/outgoing cable connection by using suitable size of cable gland, thimbling , grouting of the panel to PCC foundation PCC-M10 using 20 mm graded stone aggregate complete with following accessories all as specified and directed by Engr-in-charge :- Item Contined as Ser No. 17.39

4

-

-

... More
(a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer - MCCB 4 pole,200 Amps, breaking capacity 36 kA.- 01 Nos (c) Outgoing - MCCB 4 pole,63 Amps, breaking capacity 16 kA.- 07 Nos (1x Each Floor - 06 Nos + 1x Spare) (d)Three Ph Digital Volt Meter(0-500)Volt with selector switch.- 01Nos (e) Three Ph Digital Ammeter with CT's with appropriate Ratio along with selector switch.- 01 Nos (f) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase,01 Each Set (g) PCC Foundation.

-

-

-

... More
M&L for block masonry transformer platform of size 1.5 mtr x 1.5 mtr with height 1.2 mtr above and 60 cm below GL consisting of cement concrete in foundation of PCC 1:4:8 type D2 using 40 mm graded stone aggregate, PCC block masonry work, Sub base concrete with PCC 1:3:6 and 100mm thick top PCC 1:2:4 type B2 and 15 mm plaster on side walls in 1:4 CM incl 2 coats of white wash and providing 2 Nos supporting channel of ISMC 100 of 1.2 mtr long complete all as specified and directed.

2

-

-

... More
S&F chain link MS Galvanized fencing 64 RM length, height 2 mtr and 3mm / 4mm dia GI wire and 100 x 100 mm mess, angle or Tee section ( 40x 40 x 5 mm) fixed independently, with connecting plates for fencing post incl necessary drilled holes, bend to shape at top as directed for fencing post of the transformer yard and mild steel round bars 10 mm dia as in horizontal line wires of chain link fencing of quality Fe – 290 (Gde E- 165) making curve wall of 300 mm height around the substation with pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar type CM 1:6, plaster on side walls 1:4 CM 15 mm thick incl provn of steel gate of size 2 mtr x 1.8 mtr fabricated out of MS angle iron/ rods with locking arrangement complete all as specified and as directed.

2

-

-

... More
S & F LT cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 600 x 300 x 100 mm thick (30 cm buried in ground with "DANGER/440 V LT UG CABLE" embossed on marker including excavation and earth work complete all as specified and as directed.

40

-

-

... More
S & F HT cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 900 x 300 x 100 mm thick (60 cm buried in ground with "DANGER/11 KV UG CABLE" embossed on marker including excavation and earth work complete all as directed.

9

-

-

... More
DG SET Supply, installation, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set complied with CPCB Norms engine as per IS 10001/10002 and Alternator as per IS 13364 water cooled for power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, Pf - 0.8, 100 KVA Capacity complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genset including OEM in built fitted AMF panel with the following under-mentioned features & all as specified & as directed :- "a) Alphanumeric LCD display with LED backlight b) Operator interface. c) Suitable to provide a record of most recent fault conditions & fault history. d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA, frequency etc. e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. f) Control including provn of service adjustment & calibration of DG control functions. (A) Genset shall have followings Specifications : Prime mover Rating : 100 KVA/80 KW No of Phase : 03 Power Factor: 0.8 (LAG)" Item Contined as Ser No. 17.45 to 17.46

2

-

-

... More
(B) Engine Specification : Cooling : Water cooled Aspriation : Turbo Charged after cooled RPM : 1500 Governer : Mechanical " "(C) Alternator specifications : Voltage : 415 Volt RPM / Frequency : 1500 / 50 HZ Enclosure : IP 23 Voltage regulation (Max) : +/- 1 % Insulation class : H Class (D) Make of Engine : Cummins/ Kiloskar green/ Ashoka Leyland (E) Make of Alternator : Stamford/ Kirloskar. Make of Battery : Exide/AMCO. (F) Size/type/Number of battery : As per manufacturere (OEM) recommendations. (G) OEM manufacutured Inbuilt type AMF Panel with suitable size MCCB - 02 Nos ( DG incomming and Main Incomming), heavy duty 3 Pole contractor, Auto Manual switch, Digitial Amper Meter & Volt meter- 02 Sets (for DC battery current and AC for Mains), 3 Phase Indicators , CT`s , Suitable rating aluminium bus bar complete. Note:- (i) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates. (ii) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.

-

-

-

... More
(iii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipment’s, resistive load including POL shall be made available by the contractor. are to be included. (iv) The quoted rate shall be deemed to be inclusive of the PCC foundation required for placing the DG set and it should be as per the manufacturers recommendation. (v) Contractor shall submit the specification of DG set and take prior take approval from GE before procurement of DG set. (vi) Contractor shall produce the plateform drg form OEM and take approval of GE. (vii) Contractor shall produce all test certifacte and Purchase voucher before claming the payment. (viii) AMF panel shall be inbult type as per OEM specification.

-

-

-

... More
Supply, installation, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set complied with CPCB Norms engine as per IS 10001/10002 and Alternator as per IS 13364 water cooled for power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, Pf-0.8, 15 KVA Capacity complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genset including OEM in built fitted AMF panel with the following under-mentioned features & all as specified & as directed :-( STP 100KLD) a) Alphanumeric LCD display with LED backlight b) Operator interface. c) Suitable to provide a record of most recent fault conditions & fault history. d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA, frequency etc. e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. f) Control including provn of service adjustment & calibration of DG control functions. (A) Genset shall have followings Specifications : Prime mover Rating : 15 KVA/12 KW No of Phase : 03 Power Factor: 0.8 (LAG) Item Contined as Ser No. 17.48 to 17.49

1

-

-

... More
(B) Engine Specification : Cooling : Water cooled Aspriation : Turbo Charged after cooled RPM : 1500 Governer : Mechanical (C) Alternator specifications : Voltage : 415 Volt RPM / Frequency : 1500 / 50 HZ Enclosure : IP 23 Voltage regulation (Max) : +/- 1 % Insulation class : H Class (D) Make of Engine : Cummins/ Kiloskar green/ Ashoka Leyland (E) Make of Alternator : Stamford/ Kirloskar. Make of Battery : Exide/AMCO. (F) Size/type/Number of battery : As per manufacturere (OEM) recommendations. (G) OEM manufacutured Inbuilt type AMF Panel with suitable size MCCB - 02 Nos ( DG incomming and Main Incomming), heavy duty 3 Pole contractor, Auto Manual switch, Digitial Amper Meter & Volt meter- 02 Sets (for DC battery current and AC for Mains), 3 Phase Indicators , CT`s , Suitable rating aluminium bus bar complete.

-

-

-

... More
Note:- (i) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates. (ii) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. (iii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipment’s, resistive load including POL shall be made available by the contractor. are to be included. (iv) The quoted rate shall be deemed to be inclusive of the PCC foundation required for placing the DG set and it should be as per the manufacturers recommendation. (v) Contractor shall submit the specification of DG set and take prior take approval from GE before procurement of DG set. (vi) Contractor shall produce the plateform drg form OEM and take approval of GE. (vii) Contractor shall produce all test certifacte and Purchase voucher before claming the payment. (viii) AMF panel shall be inbult type as per OEM specification.

-

-

-

... More
FIRE FIGHTING Supply and fix automatic air release valve 100mm dia suitable for domestic water with 100 mm gun metalstop valve complete all as specified and directed.

7

-

-

... More
Factory made and CPRI tested outdoor type wall mounted on wall brackets. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-65 class protection and fabricated out of 3 mm CRCA sheet duly powder coated after nine tank process. The panel shall be front openable type adequate space all around cessories such as LT switchgear and metering instruments including internal wiring in the panel with FRLS non flamable insulated multi stranded/ solid copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories. Panel shall be mounted on 40x40x6mm angle iron frame and painted with fire red colour. Item Contined as Ser No. 17.52

5

-

-

... More
(i) INCOMING (a) MCCB 415 Volts,32-63 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 16 kA 1 Nos. (b) Digital multi function meter (V,A,Hz,Pf) with and including resin cast CTs - 01 Set. (c) Phase indicating lamp(set of 3). (II) OUTGOING (a) MCB 415 Volts,32 Amp , rating 3 Pole, (Service Breaking Capacity 10 kA)- 02 No. (b) Star delta starter suitable upto 15 Hp auto starter fire pump set-02 No (as per pump capcity) (b) Internal wiring of panel with stranded copper cable of suitable size (c) LED indicating lamp(Set of three)-01 Set (d) All standard relays and contactors to make the motor and pump operational in auto, manual and test mode to meet the pressure of 3.5 Kg per cm2 at terrace level. An auxulary switch to start the motor from desired location to test the motor and pressure from ground floor shaft. Control cables from Pressure switch to control panel, From control panel to Auxilary switch (FRLS armoured) and power cable from control panel to motor. Note: Scope of work also includes un foreseen items such as laying / passing of cable through walls/ floors/ pipes over/ beneath the surface, drilling holes core cutting etc are deemed to be included in unit quoted rate."

-

-

-

... More
Supply and fix FRLS armoured cable copper conductor 2 x 1.5 Sqmm with ISI marked complete all as specified and directed.

3500

-

-

... More
S&F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours complete all as specified and directed.

68

-

-

... More
Supply and installation, testing and commissioning of net workable Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM complete all as specified and directed. Make: SIEMENS/NOTIFIER/ BOSCH

5

-

-

... More
Supply and fix Fire Extinguisher water CO2 stored pressure type , 6.5 kg capacity complete all as specified and directed.

50

-

-

... More
Supply and fix Fire Extinguisher Dry chemical powder (ABC) type , 6.5 kg capacity complete all as specified and directed.

50

-

-

... More
Supply and fix Fire Extinguisher light weight squeeze grip type, CO2 3 kg capacity as per IS:1583 complete all as specified and directed.

50

-

-

... More
Supply and fix Fire Extinguisher mechanical foam type (AFFF) , 9 Ltrs capacity complete all as specified and directed.

50

-

-

... More
LIFT Supply and fix 4 pole MCCB 32 Amp, 50 Hz, 415 volt breaking capacity 25 KA incl suitable sheet metal enclosure complete all as specified and directed.

18

-

-

... More
STP Design, Supply, construction, installation, testing & commissioning of Package type Sewage Treatment Plant 100KLD Capacity comprising of the following items:- (i). Bar Screen(Mesh) MOC: MSEP/SS304 ,Fine Screen Mesh size 06mm - 01 No" (ii) Raw Sewage Pump - 02Nos(1W+1S) Type :Non clog sewage submersible Make: Crompton/Kirloskar/Equivallent Head: 10m Flow : 5cum/hr(minimum) (iii) Diffuser -24Nos Type :Tubular type MOC:Silicon Size: 63 mm dia X 600mm Make : CWC/Cheston (iv) MBBR Media-12 cum Size: 63mm diaX10mm MOC : PP Specific Gravity : 0.95 to 1 Surface Area : 190sqm/Cum Make Yogeshwar Pastic or equivalent make (v) Tube Settler - 6.35cum Size: 700mm MOC : PVC Type : Honey Comb Type Item Contined as Ser No. 17.62 to 17.66

1

-

-

... More
(vi) Filter Feed Pump - 02Nos (1W+1S) Type : Centrifugal Pump Make : Lubi/Kirloskar/KDS Pump Head : 40 m Flow : 5cum/Hr (vii) Treated Water Pump - 02Nos (1W+1S) Type : Centrifugal Pump Make : Lubi/Kirloskar or equivalent make Head : 30 m Flow : 5cum/Hr (viii) Air Blower - 02Nos (1W+1S) Type : Twin Lobe Root Type Both side oil cooling Suction at Top and Discharge at Bottom Make :Airvak or equivalent make Capacity : 110 cum/hr Pressure : 0.4kg/Sqcm (ix) Air Piping - 01 Lot Non submerged piping: MS/GI/uPVC Submerged piping : uPVC Make of UPVC: Kishan/Astral/Supreme/Finolex Make of MS/GI : Standard available.

-

-

-

... More
(x) Liquid Piping - 01 Lot Non submerged piping: uPVC - Sch - 40 Submerged piping : uPVC - Sch-40 Make : Kishan/Astral/Supreme/Finolex (xi) Control Panel - 01 No Type of Panel : Automatic panel of micro controller base HMI Size :7" Housing: MS with powder coating with minimum 1.6mm sheet Mode of operation ; Automatic/Manual Make of Panel : Enviro Engineers All working + Standby equipment will be change over automatic in case trip on equipment as well as cascade in operation. Blowers with VFD with auto operation of DO meter. All Motor should show individual Amp in HMI. Real time data logger for fault checking. Fault indicator like Under load, Over load, reverse phase, Single phase preventer (xii) Pressure Sand Filter - 01 No MOC of Filter : FRP Design Pressure: 10Kg/Sqcm Operation Presure : 4Kg/Sqcm. Capacity : 5cum/hr Make of pressure vessel : Pentair or equivalent make Multiple Valve : Automatic in operation through Pressure Transmitter

-

-

-

... More
(xiii) Activated Carbon Filter - 01 No MOC of Filter : FRP Size of Filter : 330 mm dia x 1350 m Ht Design Pressure : 10 Kg/Sqcm, Operation Pressure : 4 Kg/Sqcm, Capacity : 5 Cum/hr Make of pressure vessel : Pentair or equivalent make Multiple Valve : Automatic in operation through Pressure Transmitter (xiv) Disinfected Dosing System - 01 No Dosing Pump make : Vision/Verito . Type: Metering Type Capacity of Dosing Pump : 0-4LPH Nos of Dozing Pump : 02 (1W+1S) Dosing tank make : Spectron/Eqivallent, Nos of Dozing Tank: 01 No Dosing tank capacity : 100KLD Dosing tank MOC : LDPE Make :Spectron/Sintex or equivalent make (xv)Pressure Gauge - 04 Nos Range ; 0-7kg Make ; Brinda/Vision/La/Equivallent Type : Bottom mounted (xvi) Pressure Transmitter - 03 Nos Range : 0-10kg Make : Boumer/ARTACK/Danfoss Type : Bottom mounted

-

-

-

... More
(xvii) Level Sensor - 05Nos Type : Float type level sensors (xviii) DO Meter - 01 No Type : Optical type Range : 0-20ppm No maintenance type (xix) Ultra Filtration : 01 No Flow : 5cum/hr Make of UF : MOWS/Drop Saver Qua No of Module : 01 No (xx) UF Backwash Pump - 02 Nos (1W+1S) Type : Centrifugal pump Make : LUBI/Kirloskar/KDS Pump Head : 40m Flow : 15 cum/hr (xxi) Centrigfuge - 01 No Capacity : 30 kg/day MOC: PP

-

-

-

... More
(xxii) MBBR Tank x2 Nos, Capacity : 5KL Each Size of each Tank : 1.4mx1.2mx3m+0.3FB MS with FRP Inside and Epoxy Paint Outside (xxiii) Secondary Tube Settler, Capacity : 6.3KL Size : 2.1mx1.2mx2.5m + cone+0.4m FB MS with FRP Inside and Epoxy Paint Outside (xxiv) Intermediate Tank - 01 No, Capacity : 10KL MOC : LLDPE (Readymade Tank) (XXV) Aeration Tank MS FRP Module Size: 35 KL, MOC : MSFRP (xxvi) Secondary Clarifier MS FRP Module Size : 21 KL, MOC : MSFRP (xxvii) DO Meter- 01 No. Range: 0-20PPM, Type: Optocal, No Maintenance Make : Aquadex/Aavolate Note:- The bidder shall submit a comprehensive proposal (plan of action) for execution of STP Capacity 100KLD, package type including ancillary civil works such as RCC UG collection Sump capacity 40KL capacity, RCC UG Treated water Sump capacity 30KL, Blower shed 4mx4mx3.5m height and intermediate Raw Sewage Sump cum pump house and all other connected items of work for persual and approval by the Accepting officer before commencement of STP work. The quotated rate shall be deemed to be inclusive of all civil works including earth work required etc, complete in all respect

-

-

-

... More
Supply, installation, commissioning and testing of non clog vertical submersible pump of capacity 1 hp with chrome steel impeller and cutter non clog to pass 40 mm size particles incl supply with guide rail and lifting chain (two working + one standby) to transfer raw sewage water from RCC sewage collection sump to bar screen chamber , having Discharge 50 LPM at a head of 25 metre suitable for delivery pipe , 415V (+ 5% & +10%) & frequency 50Hz. (1HP) including suitable size soft starter efficiency level-2 complete all as specified and directed. Material of Construction: Pump and Motor body: cast iron ,impeller:cast iron (a) Dry run protection. (b) 1 Nos of pressure guage 2" dia with valve tee and fittings. (c) Alarm indication with signal in the event of pump failure etc. (d) Arrangement of pressure switch with all connected accessories should be provided for protection of pumpsets. (e) Provision of GI/MS suction pipe of suitable size from clear water sump to pumpsets. (f) Delivery pipe of suitable size GI pipe heavy grade from pump set to existing delivery pipe flanged type complete with all fitting suitable for flanged pipe and necessary nut, bolts, washers and rubber gasket etc including fixing of butterfly valves and non return valve all as required.

3

-

-

... More
M&L for construction of valve pit of size 0.6 x 0.6 x 0.6 m (internal diamention) one brick thick wall including MS sheet cover made of MS sheet 3 mm thick and 50 x 50 x 6 mm thick MS angle iron frame and locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed.

4

-

-

... More
SOLAR POWER GENERATION SYSTEM "Design, procure, erect install, test and commission including connecting to local utility grid; Grid connected solar photovoitaic plant of 10 KWp capacity (roof top) including solar photovoitaic Module, DC cabling, Module Mounting Structures, Combining Boxes, Lightning Protection of SPV modules and other accessories, string inverter, consisting of following main components: - Poly Crystaline Silicon Solar Photovolaic minimum of 335 Wp, not less than 10 KWp capacity, having efficiency 16.28% min under standard conditions, form fill factor more than 0.74, plant performance ratio 75% , made of high transmitivity glass front surface and it shall give high encapsulation gain ( transmittance above 90% and bending less than 0.3%). The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm2, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under Max Peak Power Pmax 335 W Voltage at Max Power :37.9V Current at Pmax: 8.85 A Short Circuit Current : 9.41 A Open Circuit Voltage: 46.27 V Module Efficiency: 16.28 % . (a) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed. (b) It shall perform satisfactority in RH 85% with temperature up to +85 degree C and should withstand wind of 150 kmph on the surface of panel. Item Contined as Ser No. 17.70 to 17.74

1

-

-

... More
(c) PV modules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. (d) Each module shall have RFID tag encapsulated with solar cell bearing following details: Name of manufacture of SPV Module, Name of Manufacturer of solar cell and module) country of Origin ( both cell and module) Peak wattage, Im, Vm and fill factor of the module IV curve of module. (e) The temperature coefficient of the module shall not be more than 0.50% degree celcius. (f) PV modules must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID. (g) It shall also be in confirmity to latest minimum technical specification issued by MNRE from time to time. Modules should be of 48 cell configuration and should be of MNRE approved companies/agencies in category/ rating 'SA-1A (h) Provision of earting and earth strip/ cable etc for earth of solar Pvmodule/ array etc as per latest IS/MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (j) Both cell and SPV modules shall be made in India and must conform to DSR norms of MNRE (k) The minimum net annual generation shall be 1500 units per kilowatt.

-

-

-

... More
(l)DC Cables & AC Cables: Suitable size of XLPE insulated tinned copper cable of solar grade, 1100 volt and UV resistant for outdoor installations confirming to IEC 60227/15694 & 60502/ is 1554 (Pt& I&II) of minium size 6 sq.mm All cables and connectors for use of installation shall be of solar grade which can withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt,burial and attack by moss and microbes for 25 years as voltage as per latest IEC/IS. All the cables/wires shall be provided with UV resistant printed ferrules for DC side .The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. The AC cables along with AC DB with necessary arrangement to Connect with the existing power supply to be done. The size of XLPE LT cable To be got approved by Engineer in charge. Suitable electronic smart meter To be fixed to measure generation of electricity. Cable batch no,drum no, IS code and size and make shall be metioned on every one meter or as per OEM practice .The wiring of the module interconnection shall be in suitable size UPVC/HDPE pipe. The cost of interconnecting DC copper cable, and earth work for trenches suitable to accommodate solar grade cables from SPV module upto inverters are included in the item.

-

-

-

... More
(m)Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanisized iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts,mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fastners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with stadpro report and submitted for the approval of the acepting officer. Cost of all equipments, copper strip up to earth test point and copper earthing etc are included in this item. The cost of sufficient earthing for lightning protection is included in this item and no extra payment will be made to the contractor on this account.

-

-

-

... More
(n)String Inverter: Procure, fixing, testing and commissioning of 10 KW , 50+3 Hz (min) 3 phase 460 volt, THD 3%, at nominal power inverter suitable to convert DC power of solar PV module/arry/ to AC for further feeding to grid confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 10 KW inverter are as under: Input (DC) DC V oltage Range: 575-850 V Max DC Voltage:1000 V Nominal Power : 10 kW Max output power : 10 kW Nominal AC current : as per standards Nominal output voltage: 460V Output Frequency : 50/60 Hz Harmonic Distortion current : 3% Efficiency : 98.3% Standby operation consumption (feed in) : 20 W

-

-

-

... More
Operating temperature up to 85 degree centigrade . The inverter shall have minimum IP 65 protection, ground fault monitoring, grid monitoring , protection against anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and temperature . The inverter shall adjust voltage and frequency levels to suit the grid . The inverter shall be selfcommulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. Maximum Power Point Tracker(MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximum the energy drawn from the PV array. The inverter shall be suitable nos of protected inputs (as per design) and outgoing shall be protected by Surge protections (MOVs) .The inverter shall be provided with protection class I (IEC 62103) .The inverter should have MODBUS, PROFIBUS, ETHERNET comn ports .The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of the inverter componant failure or from parameters beyond the inverters safe operating due to internal and/or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, ( SPD) & over current. Inverter should interfaces with Ethernet, RS485, irradation and temperature sensor, Auxilary equipment and power supply, external stop signal. Should have residual monitoring system.

-

-

-

... More
STEEL GATE M&L for construction of MS steel gate with RCC pillar on either side of gate including all necessary excavation, earth work, PCC foundation, reinforcement comprising of 8 Nos 12 mm TMT bar main reinforcement and 8mm dia. stirrups @ 150mm C/C including formwork, plaster 15mm thick in CM (1:4) with surface, Granite/ marble stone on RCC pillar/column, Arch shape MS steel plate over column with decorated Letter complete all as specified and shown on TD Drg No. CESZ/2018/TD-27 dated 08 Aug 2018, Sheet 1/3 to 3/3.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.