Military Engineer Services Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Feb 2025
Closing Date9 Mar 2025
Tender Amount₹ 16,20,000
Costs
EMD
₹ 32,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696307_1Tender No
8843/NAR/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in repairs Sprinkler with PVC arm with aluminium center movable distributor and fixing in cooling tower of 60 TR capacity complete all as per existing, specified and directed
1
-
-
... More
S&F in repairs Sprinkler with arm and fixing for cooling tower of 60 TR capacity with PVC sprinklers complete all as specified and directed
1
-
-
... More
Supply & fix in repairs flanged mounted electric motor confirming to IS:2223 for cooling tower of capacity 1.5HP complete all as specified and directed.
NOTE : (a) Contractor shall provide the original purchase vouchers and test certificates.
(b) Electric motor shall be fixed in its new position and unit rate of this item includes disconnecting the fittings and fixing the same with new motor.
1
-
-
... More
M&L for cleaning water sump of size 3 mtr x 3 mtr and 2.0 mtr deep, complete removing all mud and tree leaves, drain out water by dewatering pump , cleaning all the algae formation inside the tank, removing all scales and other formed particles inside walls by scrubbing , also including cleaning all vegetation growth all around the tank complete all as specified and directed.
2
-
-
... More
Same as item No 7.00 here-in-before but of size 3 mtr x 3 mtr and 1.5 mtr deep.
2
-
-
... More
M&L for stiching of canvass canopy between AHU to duct by using additional canvass and two layer of stiching including fixing of zip complete to all as specified and directed.
6
-
-
... More
M&L for complete flushing out the refrigerating system (chiller unit) of capacity 52 TR consist of condenser, Evaporator, cooling coil, refrigeration suction & discharge liquid line and testng with Nitrogen gas, removal of complete dirt, oil and carbon and cleaning of the whole system at ABOD AC Plant including replacement of drier gas filters complete all as specified and directed. Note:- Cleaning of 01 No. of Refrigerator unit (chiller unit) shall be measured and paid as Each job.
3
-
-
... More
All as per serial item No. 10.00 here-in-before but plant capacity 25 TR at FAD AC Plant complete all as specified and directed.
3
-
-
... More
M&L for carryout the descaling of shell and tube condenser by circulating the dilutted RAC-III Organic compound at the appropriate ratio according to the scale deposite in side the copper tubes of the condenser, circulate the chemicals till removed the scale deposite, and opening the both and covers, and manually brushes the tubes by using nylon brushes, cleaning the end covers, de-greasing the complete copper tubes end covers by circulating the caustic soda solution, and flushing through after boxing up the both end covers, the work including isolation the each condensers by dummy the inlet and outlet water pipes, renew all the end covers/inlet and outlet flanges rubber gaskets, rusted bolts nuts etc for chilled water type 52.0 TR capacity at ABOD AC Plant complete all as specified and directed. Note:- Cleaning of 01 No. of Condeser unit shall be measured and paid as Each job.
3
-
-
... More
All as per serial item No. 12.00 here-in-before but plant 25.1 TR capacity shell and tube condensers at FAD AC Plant complete all as specified and directed.
3
-
-
... More
S&F in repair fan belt of blower motors (AHU) of Size A-39 complete all as specified and directed.
6
-
-
... More
S&F in reapir fan belt of blower motors (AHU) of Size B-43 complete all as specified and directed.
6
-
-
... More
M&L for complete leak testing, rectification of leaks, by welding/brazing and pressure testing as per the standards and holding the pressure for 48 Hrs and observe for any pressure drop in the system complete all as specified and directed.
6
-
-
... More
M&L for vacuumising and dehyderating the complete system and charging only the refrigerant and testing and commissioning the system, setting of all control safety devices complete all as specified and directed.
3
-
-
... More
Supply only R-22 refrigerant gas complete all as specified and directed. Note: (a) Contractor shall produce the original purchase vouchers along with test certificates of entire quantity.
(b) Cylinder shall be arranged by the contractor at his own. However, after charging of gas, emptied gas cylinder shall be returned to the contractor.
(c) Gas shall be arranged by the contractor as per the requirement given by the Engineer-in-Charge.
(d) During transportation if any leakage is found, contractor shall be held responsible for any lapses. However, net measured quantity shall be taken into account for payment purpose.
(e) Before top up the gas in the cylinder, it shall be ensured by the contractor that cylinder is in order for filling the gas, necessary calibration shall be carried out by the contractor at his own and unit rates of this item includes this element. While quoting the rates, this aspect shall be taken into account and nothing extra shall be adissible on this account.
60
-
-
... More
Supply only R407C refrigerant gas complete all as specified and directed. Note: (a) Contractor shall produce the original purchase vouchers along with test certificates of entire quantity.
(b) Cylinder shall be arranged by the contractor at his own. However, after charging of gas, emptied gas cylinder shall be returned to the contractor.
(c) Gas shall be arranged by the contractor as per the requirement given by the Engineer-in-Charge.
(d) During transportation if any leakage is found, contractor shall be held responsible for any lapses. However, net measured quantity shall be taken into account for payment purpose.
(e) Before top up the gas in the cylinder, it shall be ensured by the contractor that cylinder is in order for filling the gas, necessary calibration shall be carried out by the contractor at his own and unit rates of this item includes this element. While quoting the rates, this aspect shall be taken into account and nothing extra shall be adissible on this account.
40
-
-
... More
Supply only Danfoss S-180 Oil for scroll compressor complete all as specified and directed.
10
-
-
... More
M&L for complete servicing of the pump motor sets 7.5 HP by dismantling from the position, cleaning, greasing, including renewable of the bushes, both end ball bearings, gasket, gland packing/water seats, both end terminal re-assembling, in position connect to the circuit test and commissioning complete all as specified and directed.
3
-
-
... More
All as per serial item No. 21.00 here-in-before but 5 HP
6
-
-
... More
All as per serial item No. 21.00 here-in-before but 3 HP
2
-
-
... More
Taking out Monoblock centrifugal electric motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, bearing, bushes etc of suitable size for following capacity of motor including necessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed . Note- All T&P required shall be supplied by contractor without extra cost.
-
-
-
... More
10 HP Motor
1
-
-
... More
20 HP Motor
1
-
-
... More
M&L for disconecting of monoblock pump set and motor of capacity 7.5HP of any make, strip opening and taking out gland packing, bearing carefully and servicing the impeller and motor complete and re-winding with appropriate size of super enamelled winding wire incl replacement of worn out ball bearing, gland pack, rubber gasket, capacitor, nut, bolts and washer greasing complete and refixing on same place and connecting to MS pipe and testing complete all as specified and directed.
NOTE : Unit rates of this item includes the cost of services including replacement of ball bearing, gland packing, rubber gasket, capacitor, nut bolts, washer of required size and greasing etc.
3
-
-
... More
All as per serial item No. 25.00 here-in-before but 5 HP
2
-
-
... More
S&F in repair butterfly valves with counter flanges of size 100 mm including bolts and nuts necessary cutting and welding and applying two coats of synthetic enamel painting over a coat of red oxide primer in welded portion, flanges complete all as specified and directed.
1
-
-
... More
All as per serial item No. 27.00 here-in-before but of size 80mm
1
-
-
... More
Supply and fixing of Dual Plate Check Valves Cast Iron body (NRV) of 100mm bore & Rating of PN -10 including nuts & bolts complete all as specified and directed.
2
-
-
... More
Same as item no 29.00 here-in-before but of size 80mm.
2
-
-
... More
Supply, installation, testing and commissioning as in repairs 3 way mixing / diverting valve of stainless steel of size 80 mm dia with proportional cooling only thermostats for the Air Handling Units complete all as specified and directed.
1
-
-
... More
Supply, installation, testing and commissioning as in repairs 25 mm dia Ball valves of stainless steel for drain with fittings etc complete all as specified and directed.
2
-
-
... More
M&L for duct insulation with 13 mm thick nitrile faom sheet insulation having density 50 kg/cum, as specified and including the following:- (a) M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage.
(b) M&L for applying rubber based adhesive CPRX compound.
(c) M&L for sealing of all longitudinal joints and circular overlaps with and including Nitrile foam tape /Aluminium foil tape 50 mm wide, to make the insulation leakproof.
(d) M & L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
12
-
-
... More
Supply & fix in repairs flanged mounted electric motor confirming to IS:2223 for cooling tower of capacity 1.5HP complete all as specified and directed.
NOTE : (a)Contractor shall provide the original purchase vouchers and test certificates.
(b) Electric motor shall be fixed in its new position and unit rate of this item includes disconnecting the fittings and fixing the same with new motor.
1
-
-
... More
Supply & fixing in repair condensor safety valve 350 PSI to 550 PSI complete all as specified and directed.
2
-
-
... More
Supply, commissioning in repairs scroll sealed compressor of capacity 12.5 TR of cooling capacity 38.6 KW at 50 Hz can be operated on R407C refrigerant with discharge connection mounting torque 110 N-m for AC plant of capacity 3 x 25 TR at 14 FAD AC Plant including valve and other fittings and testing for leakage and rectification by welding / brazing including and charging of refrigerant upto the required capacity complete all as specified and directed.
Note : (a) Refrigerant gas shall be measured and paid separately as Supply only under respective item of this Schedule. (b) Contractor shall produce original purchase voucher along with test certificate from manufacturer / autorized dealer of Compressor manufacturer as applicable.
(c) Contractor shall provide the testing facility as the testing of compressor/ installation shall be carried out in accordance to the laid down procedure. Unit rate of this item includes the said element.
1
-
-
... More
S&F in repair power contactor of ML3, 40 Amp, 3 Pole with coil voltage of 240 V, 50Hz with 2 NO + 2NC auxillary contacts suitable for upto 10 HP starter complete all as specified and directed.
2
-
-
... More
S&F in repair power contactor of ML2, 16 Amp to 25 Amps, 3 Pole with coil voltage of 240 V, 50Hz with 2 NO + 2NC auxillary contacts suitable for upto 10 HP starter complete all as specified and directed.
2
-
-
... More
S&F in repair single phase preventor of 240 V, 50 Hz suitable for upto 7.5 HP starter complete all as directed.
2
-
-
... More
S&F in repair CT Coil of 240V, 50Hz suitable for upto 7.5 HP starter as per existing complete all as specified and directed.
3
-
-
... More
S&F in repair electonic thermostatic switch type water pressure cut out switch including necessary wiring with sensors/micro processing panel and testing for smooth functioning complete all as specified and directed.
1
-
-
... More
S&F fix in repair original electronic PCB (mother board) of microprocessor based control panel unit with control circuit display of Central type AC plant and testing for smooth functioning of AC plant complete all as directed as per manufacturer/OEM design as per existing make & Model as per existing. Note: Contractor also submitt the test sheet of relay functioning of chiller unit after completion of job.
1
-
-
... More
S&F in repair MCCB 4 pole, 250 Amps, 415 volt Icu=100% lcs complete all as specified and directed.
1
-
-
... More
S&F in repair MCCB 4 pole, 100 Amps, 415 volt Icu=100% lcs complete all as specified and directed.
2
-
-
... More
S&F in repair MCB TP 3 pole, C curve of 40-63 Amps, 415 volt ccomplete all as specified and directed.
8
-
-
... More
S&F in repair industrial type thermometer with adopter graduated both in Fahrenheit and centigrade including syphon assembly complete all as specified and directed.
4
-
-
... More
S&F in repair water pressure gauge 100 mm dia, anologe type range 0-500 PSI or 0-14 kg/sq.cm including necessary rapair to leakage of water by replacing 15 mm dia water tube in U shape for fixing water pressure gauge in vertical position with control valve connected to mains chilled/raw water pipe line 100/80 mm dia complete all as specified and directed.
2
-
-
... More
S&F as in repairs thermostate expansion valve of copper metal suitable for capacity 25 to 52 TR chillar unit capacity of Plants complete all as specified and directed.
1
-
-
... More
Taking down existing burnt backalite connector from panel board, replacement of 63 Amps Bacakalite cable connector after replacement of burnout existing copper lugs complete all as specified and directed.
12
-
-
... More
Taking down existing burnt backalite connector from panel baord, replacement of 20 Amps Bacakalite cable connector after replacement of burnout existing copper lugs complete all as specified and directed.
10
-
-
... More
S&F in repair the cast iron ‘Y’ Strainers made of mild steel of size 100mm complete including nuts & bolts.
1
-
-
... More
S&F in repair the cast iron ‘Y’ Strainers made of mild steel of size 80mm complete including nuts & bolts.
1
-
-
... More
Servicing and cleaning of AHUs cooling coil and pan, Washing filters with the help of pressure jet and cleaning with de scaling chemicals, cleaning PAN humidifier and dehumidifier, cleaning HOt water generator and brazing, if required. incl testing complete all as specified and directed for the suitable capacity following AC Plants.
-
-
-
... More
8500 CFM capacity
4
-
-
... More
19000 CFM capacity
2
-
-
... More
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 8 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
6
-
-
... More
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth strip of size 25 x 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
4
-
-
... More
Annual comprehensive maint/minor repair by service Engineer of OEM or his authorised rep having minor adjustment of all landing gate & car gate, controller dressing, car cleaning, sensor reapair/replacement and controller cleaning, replacement of gear oil, adjustment of guide shoe holder, OSG pit clearance adjustment of electrically operated lift of capacity 1000 kgs, Speed 0.70m/sec, 2 floor/2 stop, collective down control type, 3 phase, V3F drive type, checking and repairing sensor system for smooth operation, manual/auto door ACO installed at NBC storage shed of 222 ABOD complete all as specified and directed. Make of LIFT: ECE Pvt Ltd Note : Testing and necessary Inspection be carried out by competent person from Office of the Chief Inspector of Lift & Excalator of State as per Rule 4 & 6 of The Assam Lifts and Excalators Rule 2016 or as per policy for use of lift and Test report be submitted in duplicate by contractor to Engr-in-charge .
1
-
-
... More
Taking down old unserviceable panel and S&F new Microprocessor V3F Down collective monarch control panel 10 HP suitable for ECE make lift complete including wiring connections and testing and commissioning of controller, wire rope , repairing gate, pit pulley adjustment, safety switches activation and reconditioning of lift include replacement of followings complete all as specified and directed.
1
-
-
... More
Taking down old defective from Main hoisting 3 lengths of wire ropes of 10mm dia and S&F new steel wire ropes of 10mm dia 3 lengths of same length alongwith all fittings assy such bulldog gripe, nuts & bolts of suitable size include testing and commissioning on load complete all as specified and directed. Make: USHA MARTIN/ Note : Contractor should submitt test certificate of rope before fixing.
-
-
-
... More
S&F Door spares for all landing & car complete all as specified and directed. Lot- 01
-
-
-
... More
S&F ARD system for above mentioned lift include UPS & Btys as per OEM recommendation suitable for existing model lift complete all as specified and directed including testing and commissioning.
1
-
-
... More
M&L for toping up gear oil for electrically operated lift complete all as specified and directed
4
-
-
... More
M&L for complete repairing of chiilled water line by inserting first layer as nitrile foam second layer as glass clothing and aluminium cladding over the top surface of the pipeline complete to entire satisfaction of engineer-in-charge.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%