Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 96,640Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664387_2Bid Award Id
ViewTender No
8007A/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Returning filling in any type of soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
30
-
-
... More
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
17.25
-
-
... More
Supply Installation, fixing, testing and commissioning of Split Air conditioner unit of 1.5 TR capacity (split type unit comprising of indoor and outdoor unit white colour) electric driven, Signal Phase, 230 Volt (220-240 Volt), 50 Hz and with inbuilt air ioniser and plasma fitter for better indoor air quality, having latest model of AC with 3 Star BEE rating, having ISEER value not less than 3.50 Wh, Split AC, having rotary compressor, having Round tube Plate fin, copper tube condensor with hydrphillic coating for better protection of condenser from corrosion with R-32 refrigerant (non CFC gas), having dehumidefication feature, copper tubing, including necassary fixing arrangement complete (indoor unit at suitable place and hight inside the room and outdoor unit at suitable place outside the room)including metallic bracket with fixing bolts, anchore fashner for fixing bracket for mounting outdoor unit , insulated piping,making all electrical connections etc from Power supply socket to AC unit by providing suitable size PVC insulatated sheathed copper conductor cable size not less than 4 Sqmm x 3 core, with remote feature complete all as specified and directed by Eng in Charge. Make : CARRIERS/ O General / Hittachi / Daikin. Note :- Note : (i) Air conditioner shall be initial filled/charged with refrigerant as per OEM specified recomendation quantity.
(ii) Suitable piping shall be provided of adequate length of size 5/8" for draining of condensate water from indoor unit.(iii) AC unit to be supplied with cordless remote control for operation.
(iv) The condenser unit shall be copper tube with hydrphillic coating for better protection of condenser from corrosion.(v) The refrigerant to be used shall be R 32 (Non CFC compliance) as per latest technology.(vi) The AC unit shall be latest model having valid 3 Star BEE rating as on date of installation.(vii) Contractor shall submit the brochure of AC with detail technical specification and take approval of GE before procurement. (viii) Contractor shall submit the Purchase voucher, Test certificate and warrranty certificate of AC. Contractor shall obtain the Warranty certificate from manufacture and to be submitted to department. (ix) All the necessary accessories and T&P required on site for installation of indoor and out door unit of split AC and window AC shall be provided by contractor. (x) Installation of AC shall be carried out through OEM.
(xi) Compresssor of unit shall be of min 10 yrs manufacture warranty and product warranty should be not less than two year. Contractor shall submit the warranty cetrificate to department.
(xii) Power supply electric cable to be provided with 15 Amp metal clad Pin top and to connect with source of supply by the contractor without any cost
7
-
-
... More
Note : (xiii) Additional refrigerant pipes with and including filling of additional quantity of refrigerant as required on site under guidance of OEM from outer unit to indoor unit beyond as supplied by OEM up to 10 mtrs is deemed to be included in unit rate.
(xiv) All civil work for drilling the hole in wall of any thickness on site for laying the refrigerant pipe line, and electrical cable from out door unit to indoor unit of AC and to making good to match the surface as existing to be done by contractor with out any extra cost.
-
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
7
-
-
... More
S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.
7
-
-
... More
M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed.
(Note: For payment purposes only punned down thickness of sand shall be measured )
20
-
-
... More
M & L laying old size sub class ‘B’ brick for PVC/ XLPE under ground cable protection in trench, layed in the manner that width of brick to be peperndicular to the axis of cable , over LT under ground cable complete all as specified and directed.
1640
-
-
... More
Materials and Labour for, broken stone or boulder hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface , complete all as specified and directed.
12
-
-
... More
M & L for cement concrete in foundation, filling and mass concrete in M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
5
-
-
... More
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 100 mm thick finished even and smooth without using extra cement complete all as specified and directed.
70
-
-
... More
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
1300
-
-
... More
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
70
-
-
... More
Supply, installation, commissioning and testing of three phase Servo control Voltage stabilizer capacity 100 KVA ( confirming to BIS9815 (part-I) : 1994 reaffirmation 2019 latest version) Three phase four wire (RYNB), 50 Hz Naturally Oil cooled, indoor, unbalanced type, copper wound metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operationwith for automatic operation, three phase naturally oil cooled indoor 1st filling of transformer oil up to level having following specification with and including necessary foundation as per manufacturer,s instruction & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specif. (1) Input voltage 300V-480V or as per ground requirements (2) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (3) Rated frequency 50 Hz
(4) No distortion in wave form
(5) Response time not to exceed 10 mille seconds
(6) Sensitivity (±)1%
(7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (8) No load losses less than 0.5% (9) Full load losses less than 2.5%
(10) Duty cycle - continuous 24 x 7 (11) Efficiency more than 95%
(12) Type of load: 3 phase, unbalanced type
(13) Digital display Voltmeter/Ampmeter (14) class of insulation- F (15) Winding temperature rise- Max 55º C (10º C above operating temperature) (16) Protection- (a) Overload protection (b) Short circuit protection (c) High/Low voltage cut off (d) Bypass arrangment in case of emergency (e) Single phase sequence change (f) Earth fault protection.
Make: Volina/IECO/V-guard
1
-
-
... More
Supply, installation, commissioning and testing of three phase Servo control Voltage stabilizer capacity 50 KVA ( confirming to BIS-9815 (part-I) : 1994 reaffirmation 2019 latest version) Three phase four wire (RYNB), 50 Hz Naturally Oil cooled, indoor, unbalanced type, copper wound metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operationwith for automatic operation, three phase naturally oil cooled indoor 1st filling of transformer oil up to level having following specification with and including necessary foundation as per manufacturer,s instruction & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified . (1) Input voltage 300V-480V or as per ground requirements (2) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (3) Rated frequency 50 Hz
(4) No distortion in wave form
(5) Response time not to exceed 10 mille seconds
(6) Sensitivity (±)1%
(7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (8) No load losses less than 0.5% (9) Full load losses less than 2.5%
(10) Duty cycle - continuous 24 x 7 (11) Efficiency more than 95%
(12) Type of load: 3 phase, unbalanced type
(13) Digital display Voltmeter/Ampmeter (14) class of insulation- F (15) Winding temperature rise- Max 55º C (10º C above operating temperature) (16) Protection- (a) Overload protection (b) Short circuit protection (c) High/Low voltage cut off (d) Bypass arrangment in case of emergency (e) Single phase sequence change (f) Earth fault protection.
Make: Volina/IECO/V-guard
1
-
-
... More
Supply, installation, commissioning and testing of three phase Servo control Voltage stabilizer capacity 30 KVA ( confirming to BIS9815 (part-I) : 1994 reaffirmation 2019 latest version) Three phase four wire (RYNB), 50 Hz Naturally Oil cooled, indoor, unbalanced type, copper wound metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operationwith for automatic operation, three phase naturally oil cooled indoor 1st filling of transformer oil up to level having following specification with and including necessary foundation as per manufacturer,s instruction & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified. (1) Input voltage 340V-480V or as per ground requirements (2) Output voltage stabilized at any designed/desired voltage 375-415 (Adjustable) (3) Rated frequency 50 Hz
(4) No distortion in wave form
(5) Response time not to exceed 10 mille seconds
(6) Sensitivity (±)1%
(7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase
(8) No load losses less than 0.5% (9) Full load losses less than 2.5%
(10) Duty cycle - continuous 24 x 7 (11) Efficiency more than 95%
(12) Type of load: 3 phase, unbalanced type
(13) Digital display Voltmeter/Ampmeter (14) class of insulation- F (15) Winding temperature rise- Max 55º C (10º C above operating temperature) (16) Protection- (a) Overload protection (b) Short circuit protection (c) High/Low voltage cut off (d) Bypass arrangment in case of emergency (e) Single phase sequence change (f) Earth fault protection. Make: Volina/IECO/V-guard
3
-
-
... More
Supply, installation, commissioning and testing of three phase Servo control Voltage stabilizer capacity 15 KVA ( confirming to BIS9815 (part-I) : 1994 reaffirmation 2019 latest version) Three phase four wire (RYNB), 50 Hz Naturally Oil cooled, indoor, unbalanced type, copper wound metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operationwith for automatic operation, three phase naturally oil cooled indoor 1st filling of transformer oil up to level having following specification with and including necessary foundation as per manufacturer,s instruction complete all as specified and directed by Engr-in charge. (1) Input voltage 340V-480V or as per ground requirements (2) Output voltage stabilized at any designed/desired voltage 375-415 (Adjustable) (3) Rated frequency 50 Hz
(4) No distortion in wave form
(5) Response time not to exceed 10 mille seconds
(6) Sensitivity (±)1%
(7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase
(8) No load losses less than 0.5% (9) Full load losses less than 2.5%
(10) Duty cycle - continuous 24 x 7 (11) Efficiency more than 95%
(12) Type of load: 3 phase, unbalanced type
(13) Digital display Voltmeter/Ampmeter (14) class of insulation- F (15) Winding temperature rise- Max 55º C (10º C above operating temperature) (16) Protection- (a) Overload protection (b) Short circuit protection (c) High/Low voltage cut off (d) Bypass arrangment in case of emergency (e) Single phase sequence change (f) Earth fault protection. Make: Volina/IECO/V-guard
7
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.Location: ALG Ziro
2
-
-
... More
Supply, Installation, Testing and Commissioning of 20 KVA single-phase Servo Controlled Voltage Stabilizer factory assembled as per BIS 9815 complete including necessary foundation work all as specified and directed by Engr-in charge all as specified and as directed with the following specifications: a) Servo Controlled technology. b) Type – Single Phase c) Cooling - Air-cooled d) Testing - As per IS:9815 and IS:2026 e) Input voltage – 170V - 270V (Ph-N) f) Output voltage – 220/230V +/- 1% (Ph-N) g) Frequency - 50Hz +/- 5% h) Metering – Digital Microprocessor based j) Efficiency – Not less than 98% j) Response time - less than 10 mili second k) Insulation Resistance (IR) - More than 6 Mega ohms at 500 V DC l) Protections Provided - Over load, short circuit Protection, High/low voltage cut off m) Construction - Indoor-type (n) Protection- (a) Overload protection (b) Short circuit protection (c) High/Low voltage cut off (d) Bypass arrangment in case of emergency (e) Earth fault protection. Location: WCDMA Site-II-01 & C BAND Satcom-01, Make: Volina/IECO/V-guard
2
-
-
... More
Supply, Installation, Testing and Commissioning of 30 KVA single-phase Servo Controlled Voltage Stabilizer factory assembled as per BIS 9815 complete including necessary foundation work all as specified and directed by Engr-in charge all as specified and as directed with the following specifications: a) Servo Controlled technology. b) Type – Single Phase c) Cooling - Air-cooled d) Testing - As per IS:9815 and IS:2026 e) Input voltage – 170V - 270V (Ph-N) f) Output voltage – 220/230V +/- 1% (Ph-N) g) Frequency - 50Hz +/- 5% h) Metering – Digital Microprocessor based j) Efficiency – Not less than 98% j) Response time - less than 10 mili second k) Insulation Resistance (IR) - More than 6 Mega ohms at 500 V DC l) Protections Provided - Over load, short circuit Protection, High/low voltage cut off m) Construction - Indoor-type (n) Protection- (a) Overload protection (b) Short circuit protection (c) High/Low voltage cut off (d) Bypass arrangment in case of emergency (e) Earth fault protection. Location: (Location: B4B Building), Make: Volina/IECO/V-guard
1
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:-
1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock.
2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high.
3.The cost of GI strip of size 32 X 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer.
5. Cost of welding and nut bolts are deemed to be included in the unit rate.
18
-
-
... More
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtr below ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction of inspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately
(Note : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with 4 x Bags of bentonite clay of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986. (vii) The cost of Copper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.
6
-
-
... More
Supply and Laying galvanized steel tubing,80 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, with and including taking down existing unserviceable complete all as specified and directed.
18
-
-
... More
Supply and Laying galvanized steel tubing,50 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, with and including taking down existing unserviceable complete all as specified and directed.
18
-
-
... More
Horizontal boring of holes by mechanical means, at under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 80 to 100 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed.
Note : GI pipe of dia 80 mm & 100mm will be measured & paid separately under respective items.
6
-
-
... More
Supply and fix for, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc. as required by using GI earth strip of size 32x6 mm, complete all as specified and directed.
30
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core with reduced neutral conductors (2 core), nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
20
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
120
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core with reduced neutral conductors (2 core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
20
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
30
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
210
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
140
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
60
-
-
... More
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with 100 Amp,16 KA,TPN MCCB as incomer (Vertical type double door, 100 Amps, TPN, 16 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set,with and including and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
3
-
-
... More
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 100 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
1
-
-
... More
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 63 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
9
-
-
... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 25 sq. mm to 50 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0130 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
4
-
-
... More
Supply and fix for, 12mm dia copper pipe, hand drawn, tempened, seamless, phosphorous deoxidized, non arsenic and degreased conforming to 13348 specification of IS/ISO 7396-1 (2007) medical gas pipeline system including painting with thickness 0.7mm, laid as per HTM-2022 of UG specification. The supply of pipes accompany with manufacturer's test certificates for the physical properties of copper pipes and their chemical composition . The supply of pipe line be further substantiated with inspection certificates from manufacturer's maxflow. Copper pipe (imported) shall be made of copper and suitable for a team of working pressure of 17 bar and especially made for brazed socketed type connection. Copper fitting shall be made of copper and suitable for a steam of working pressure of 17 bar and especially made for brazed socketed type connection as per BS-857. Brazing for copper in brass, joints with copper silver as per BS 857. Brazing for corner in brass, joints with copper silver as per BS -1845-1966 with use of flux. Supports shall be provided to ensure that the pipe do not sag. The spacing of support should not exceed 1.6 mm for any size of pipe. Suitable sleeves provided wherever pipes cross through wall/ slabs and all pipe clamps not reactive to copper & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified .
16
-
-
... More
All as per serial item No.40 here-in-before but dia of pipe15mm with thickness 0.9mm copper complete all as specified and directed.
43
-
-
... More
Supply and fix for, surface mounted imported oxygen gas outlet point conforming to NFPA 99 specifications for gas outlet complete all as specified and indicated below :-
(a) The outlets shall be UL listed, CSA certified fully compliance with latest edition of NFPA-99. (b) Consisting of a gas specific rough in assembly latch valve assembly and cover plate. (c) Rough in assembly of modular design, a brass outlet block shall be attached to the mounting bracket to permit 1/2" OD type-K copper inlet tube to swivel 360 degrees for attachment to the piping system. (d) The outlet equipped with a primary and secondary check valve.
(e) Latch valve assembly shall include a single compression seal primary valve. It shall be indexed to the corresponding rough in assembly to avoid accidental cross connection. (f) Single piece chromed fascia plate shall frame the outlet with the back rough-in-mounted. The outlet shall adjust from 3/8" (10mm) to 11" (25 mm) variation in wall thickness. (g) A large full colour coded front plate for ease of gas identification. (h) There shall be a push button release mechanism for disconnecting apparatus and shall be accessible from top bottom and side of the outlet & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
4
-
-
... More
Supply, install, testing and commissioning of oxygen flow meter with humidifier bottle (indegenous). The back pressure compensated flow meter shall be accurate gas flow measurement and control within a range of 0-15 LPM for use in a variety of respiratory therapy gas delivery system. The flow tube and shroud component shall be made of brass duly nickel chrome plated. Flow meter shall be supplied with bubble type humidifier bottle. The humidifier bottle shall be of unbreakable materials, & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified .
(Make : KINGCO/PES/MPS)
4
-
-
... More
Supply, installation, testing and commissioning of isolation valves for 15 mm copper pipe valves used will be of quarter tum action type for opening and closing the gas supply, valves shall be of non ferrous materials and having full bore and capable to with stand working pressure of 300 psi/27 Hg vacuum and shall have the following specifications & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified :-
(i) Body material-brass alloy. (ii) Ball- brass alloy hard chrome plated, pressure 20 bar size 15 NK 54 NK. (iii) Seal - PTFE. (iv) Handle-rugged steel with PVC grip. (v) Maximum working pressure-20 bar. (vi) Size-15 NB to 54 NB
2
-
-
... More
Supply and fix for, distace alarm system for oxygen gas monitoring installed near outlet points with audio visual alarm showing working bank quantity in each banks, low pressure indicators etc. and all necessary indicators to monitor status of oxygen in each bank for ease of surgeon & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
1
-
-
... More
Supply, installation, testing and commissioning of 3 cylinder Oxygen manifolad, & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as
1
-
-
... More
Supply, installation, testing and commissioning of semi automation oxygen delivery control panel, & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
1
-
-
... More
Material and labour for, brass NRV for gas pipe line of dia 15mm, & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified.
2
-
-
... More
Supply and fix for non return valve for connection of oxygen gas cylinder as approved suitable for oxygen copper pipe line & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified.
3
-
-
... More
Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.
Note: - (Water proofing compound will be measured and paid separately)
-
-
-