Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Eprocure
Opening Date19 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
B. ELECTRICALS :- (a) Checking and Tightening all Electric Connections (b) Checking the Contactors, Relays, etc for Overheating or Flashing. (c) Cleaning off All Connections and Control Cables. (d) Properly Bunching the loose Control Cables. (e) Checking Functioning of Cable Carriers. (f) Checking the Connections and Serviceability of VVVF Drives for Smooth Working. (e) Ground Motion Control Panel (h) Opening the Push Button Control Unit, Checking all Connections, Replacing Flashed/ Overheated Connections, General Cleaning and Checking all the Functions of the LT/CT/ Hoist Motion Push Buttons and Lights/ VVVF Switch including Re-assembling the Unit complete. C. LOAD TESTSTING :- Load Testing complete for LT/CT/Hoist Motion of the 2 Ton EOT Cranes (installed at Different Locations) for 125% Capacity using any type of Dead Weight, complete all as specified and as directed.

-

-

-

... More
NOTE :- (a) Necessary Weights for Load Testing shall be arranged by the Contractor at his/ their Own Cost. (b) Shifting of Load at Site and Shifting to Different Buildings/ Locations using Truck/ Mobile Crane, etc. of suitable Capacity shall be arranged by the Contractor. (c) Tools, Tackles, Chains and Sling, etc. of suitable capacity required for Load Testing shall be arranged by the Contractor. (d) Quoted Unit Rate shall be deemed to including the Cost of all above and No Extra Payment on this account shall be made. Adjustment of Brakes, Motors, Gear Boxes, Electrical System, Load Hook, Steel Wire Ropes, Limit Switches and all related Items, complete all specified and directed. (e) The Quoted Unit Rates are inclusive of Labor & Servicing of Crane. (f) Spare Parts to be Measured & Paid for separately under respective Items here-in-after.

-

-

-

... More
M&L Periodical Inspection/ Servicing/ Load Testing of 10 Ton Capacity Flame Proof EOT Crane with Double Grider of any Make installed at Different Buildings/ Locations at Site, Making the Crane in Serviceable Condition, Attending Complaints of Cranes on Call Basis, complete all as specified and as directed with and including Operations for Maintenance all as specified as here-under:-

1

-

-

... More
A. LONG TRAVERSE MOTION/ CROSS TRAVERS MOTION/ HOIST MOTION :- (a) Checking Gear Box Oil Level, Checking and Rectification of Leakage if any and Filling with New Oil up to required Level. (b) Checking Functioning of all Brakes of any Capacity and Making Adjustment for Proper Working. (c) Checking Motion Wheel for any Abnormal Sound & Checking Mounting/ Fixing Arrangement. (d) Checking of Grease in geared Coupling and Tightening of Nuts, Bolts, etc. (e) Checking of Motion cut off at Extreme Ends with Limit Switches. (f) Checking Drive Shaft and Coupling including Tightening of Nut and Bolts. (g) Checking Oil in FLP Thrustors, Checking any Leakage any Filling with New Oil. (h) Checking Terminal Connection of all LT Motion of Three Phase FLP Electric Motor and Tightening Properly including Replacing Burnt out/ Overheated Cable Ends if any.

-

-

-

... More
B. ELECTRICALS :- (a) Checking and Tightening all Electric Connections (b) Checking the Contactors, Relays, etc for Overheating or Flashing. (c) Cleaning off All Connections and Control Cables. (d) Properly Bunching the loose Control Cables. (e) Checking Functioning of Cable Carriers. (f) Checking the Connections and Serviceability of VVVF Drives for Smooth Working. (e) Ground Motion Control Panel (h) Opening the Push Button Control Unit, Checking all Connections, Replacing Flashed/ Overheated Connections, General Cleaning and Checking all the Functions of the LT/CT/ Hoist Motion Push Buttons and Lights/ VVVF Switch including Re-assembling the Unit complete. C. LOAD TESTSTING :- Load Testing complete for LT/CT/Hoist Motion of the 2 Ton EOT Cranes (installed at Different Locations) for 125% Capacity using any type of Dead Weight, complete all as specified and as directed.

-

-

-

... More
NOTE :- (a) Necessary Weights for Load Testing shall be arranged by the Contractor at his/ their Own Cost. (b) Shifting of Load at Site and Shifting to Different Buildings/ Locations using Truck/ Mobile Crane, etc. of suitable Capacity shall be arranged by the Contractor. (c) Tools, Tackles, Chains and Sling, etc. of suitable capacity required for Load Testing shall be arranged by the Contractor. (d) Quoted Unit Rate shall be deemed to including the Cost of all above and No Extra Payment on this account shall be made. Adjustment of Brakes, Motors, Gear Boxes, Electrical System, Load Hook, Steel Wire Ropes, Limit Switches and all related Items, complete all specified and directed. (e) The Quoted Unit Rates are inclusive of Labor & Servicing of Crane. (f) Spare Parts to be Measured & Paid for separately under respective Items here-in-after.

-

-

-

... More
M&L Periodical Inspection/ Servicing/ Load Testing of 2.0 Ton to 5.0 Ton Capacity Flame Proof HOT Crane with Double Grider of any Make installed at Different Buildings/ Locations at Site, Making the Crane in Serviceable Condition, Attending Complaints of Cranes on Call Basis, complete all as specified and as directed with and including Operations for Maintenance all as specified as here-under:-

5

-

-

... More
A. LONG TRAVERSE MOTION/ CROSS TRAVERS MOTION/ HOIST MOTION :- (a) Checking Gear Box Oil Level, Checking and Rectification of Leakage if any and Filling with New Oil up to required Level. (b) Checking Functioning of all Brakes of any Capacity and Making Adjustment for Proper Working. (c) Checking Motion Wheel for any Abnormal Sound & Checking Mounting/ Fixing Arrangement. (d) Checking of Grease in geared Coupling and Tightening of Nuts, Bolts, etc. (e) Checking of Motion cut off at Extreme Ends with Limit Switches. (f) Checking Drive Shaft and Coupling including Tightening of Nut and Bolts. (g) Checking Oil in FLP Thrustors, Checking any Leakage any Filling with New Oil. (h) Checking Terminal Connection of all LT Motion of Three Phase FLP Electric Motor and Tightening Properly including Replacing Burnt out/ Overheated Cable Ends if any.

-

-

-

... More
B. ELECTRICALS :- (a) Checking and Tightening all Electric Connections (b) Checking the Contactors, Relays, etc for Overheating or Flashing. (c) Cleaning off All Connections and Control Cables. (d) Properly Bunching the loose Control Cables. (e) Checking Functioning of Cable Carriers. (f) Checking the Connections and Serviceability of VVVF Drives for Smooth Working. (e) Ground Motion Control Panel (h) Opening the Push Button Control Unit, Checking all Connections, Replacing Flashed/ Overheated Connections, General Cleaning and Checking all the Functions of the LT/CT/ Hoist Motion Push Buttons and Lights/ VVVF Switch including Re-assembling the Unit complete. C. LOAD TESTSTING :- Load Testing complete for LT/CT/Hoist Motion of the 2 Ton EOT Cranes (installed at Different Locations) for 125% Capacity using any type of Dead Weight, complete all as specified and as directed.

-

-

-

... More
NOTE :- (a) Necessary Weights for Load Testing shall be arranged by the Contractor at his/ their Own Cost. (b) Shifting of Load at Site and Shifting to Different Buildings/ Locations using Truck/ Mobile Crane, etc. of suitable Capacity shall be arranged by the Contractor. (c) Tools, Tackles, Chains and Sling, etc. of suitable capacity required for Load Testing shall be arranged by the Contractor. (d) Quoted Unit Rate shall be deemed to including the Cost of all above and No Extra Payment on this account shall be made. Adjustment of Brakes, Motors, Gear Boxes, Electrical System, Load Hook, Steel Wire Ropes, Limit Switches and all related Items, complete all specified and directed. (e) The Quoted Unit Rates are inclusive of Labor & Servicing of Crane. (f) Spare Parts to be Measured & Paid for separately under respective Items here-in-after.

-

-

-

... More
Supply only AC Solenoid Brake, Type S for existing Drum Size and as per Equivalent Model of any Make suitable for Ground Requirements, complete all as specified and as directed.

2

-

-

... More
Supply only Air Break Contactor 12 Amp Coil Voltage 110 Volt, 50 Hz complete including Taking out Old Unserviceable One, complete all as specified and as directed. MAKE : ABB/ L&T/ SEIMENS

6

-

-

... More
Supply only Brake Liner Set of suitable existing Size of Drum for LT/CT Motion of 2 Ton Capacity FLP Crane, complete all as specified and as directed.

4

-

-

... More
Supply only Brake Liner Set of suitable Existing Size of Drum for LT/CT Motion of 10 Ton Capacity FLP Crane, complete all as specified and as directed.

4

-

-

... More
Supply only Flame Proof Thrustor Unit complete as per existing Capacity, complete all as specified and as directed.

4

-

-

... More
Supply only Limit Switch for Long Traverse Heavy duty of 2 Ton Capacity EOT Cranes, complete all as specified and as directed.

2

-

-

... More
Supply only Limit Switch for Long Traverse Heavy duty of 10 Ton Capacity EOT Cranes, complete all as specified and as directed.

2

-

-

... More
Supply Only Limit Switch Roller Lover type of Cross Traverse for 2 Ton Capacity EOT Cranes/ Hoist, complete all as specified and as directed.

2

-

-

... More
Supply Only Limit Switch Roller Lover type of Cross Traverse for 10 Ton Capacity EOT Cranes/ Hoist, complete all as specified and as directed.

2

-

-

... More
Supply only for MS Coupling 25mm dia with Nuts, Bolts and Bushes suitable for LT/CT Motors, complete all as specified and as directed.

3

-

-

... More
Supply only Over Load Relays Range from 1.58 Amp to 2.3 Amp for Power Contactors or Equivalent Model of any Make suitable for Ground requirements, complete all as specified and as directed.

2

-

-

... More
Supply only Over load Relays Range from 2.4 Amp to 3.8 Amp for Power Contactors and as per BCH Cat Part No. MC 305ANA3G or Equivalent Model of any Make suitable for Ground requirements, complete all as specified and as directed.

1

-

-

... More
Supply only Torque Spring suitable for 6 Kg Capacity 100mm dia Drum Brakes of LT/CT Motion, complete all as specified and as directed.

3

-

-

... More
Supply only Transformer 440 Volt/ 110 Volt for 2 Ton Capacity EOT Crane, complete all as specified and as directed

2

-

-

... More
Supply only Transformer 440 Volt/ 110 Volt for 10 Ton Capacity EOT Crane, complete all as specified and as directed

2

-

-

... More
Supply only Break Oil/ Fluid to Hydraulic Throttle Break for Toping up/ Replacing, complete all as specified and as directed. MAKE : CASTROL/ SERVO/ SHELL

10

-

-

... More
Supply only Gear Oil Grade 20 W 40 (Heavy Duty Industrial Oil) suitable for Reduction Gear Boxes, complete all as specified and as directed.

60

-

-

... More
M&L Rewinding of Motor 0.5 HP to 1.0 HP Capacity of Crane, after 3 Phase, 415 Volts, Other Parts and Rewinding with Super Enameled Copper Wire of Same Gauge and Number of Turns and Applying Insulating Varnish including Overhauling/ Servicing Greasing and Replacement of Unserviceable Bearings and Miscellaneous Parts and Re-assemble the Parts, Re-fixing to the Position, Testing for its Satisfactory Working, etc., complete all as specified and as directed.

3

-

-

... More
M&L Rewinding of Motor 2.0 HP to 3.0 HP Capacity of Crane, after 3 Phase, 415 Volts, Other Parts and Rewinding with Super Enameled Copper Wire of Same Gauge and Number of Turns and Applying Insulating Varnish including Overhauling/ Servicing Greasing and Replacement of Unserviceable Bearings and Miscellaneous Parts and Re-assemble the Parts, Re-fixing to the Position, Testing for its Satisfactory Working, etc., complete all as specified and as directed.

3

-

-

... More
M&L Rewinding of Motor 5.0 HP to 7.5 HP Capacity of Crane, after 3 Phase, 415 Volts, Other Parts and Rewinding with Super Enameled Copper Wire of Same Gauge and Number of Turns and Applying Insulating Varnish including Overhauling/ Servicing Greasing and Replacement of Unserviceable Bearings and Miscellaneous Parts and Re-assemble the Parts, Re-fixing to the Position, Testing for its Satisfactory Working, etc., complete all as specified and as directed.

3

-

-

... More
M&L Checking existing V3F Drive System of Crane Capacity 2 Ton to 10 Ton and Repairing of Control Panel, with all Accessories as under-mentioned for EOT Crane of Double Girder Type Capacity 2 Ton, complete all as specified and as directed. (a) V3F AC Drive 5.5 KW (b) V3F AC Drive 1.5 KW

4

-

-

... More
S&F Steel Wire Rope Multi-stranded for 2 Ton Capacity EOT Crane mm dia including Taking down Old Unserviceable Steel Wire Rope, complete all as specified and as directed.

80

-

-

... More
S&F Steel Wire Rope Multi-stranded for 10 Ton Capacity EOT Crane mm dia including Taking down Old Unserviceable Steel Wire Rope, complete all as specified and as directed.

100

-

-

... More
S&F PVC insulated Sheathed with Copper Bunched Conductor Cable of Size 1.5 Sqmm, 16 Core including Taking down Old Unserviceable Cable, complete all as specified and as directed.

30

-

-

... More
S&F Three Pole Power Contactor with Aux. Contact 1NO+1NC, 12 Amp, 3 Phase, 415 Volt, AC as per Existing Make and Model of BCH or Equivalent Model of any Make suitable for Ground requirements including Taking down Old Unserviceable Power Contactor with Aux. Contact, complete all as specified and as directed.

2

-

-

... More
S&F Three Pole Power Contactor with Aux. Contact 1NO+1NC, 18 Amp, 3 Phase, 415 Volts, AC as per Existing Make and Model of BCH or Equivalent Model of any Make suitable for Ground requirements including Taking down Old Unserviceable Power Contactor with Aux. Contact, complete all as specified and as directed.

2

-

-

... More
Supply, Installation, Commissioning & Testing of Lifting Hook Block Shank type Plain Hooks with Hook Latch as per IS:3815 and IS:5749, suitable for 2 Ton Capacity EOT Crane including Dismantling Unserviceable Hook Block from EOT Crane, complete all as specified and as directed.

2

-

-

... More
S&F Brass Gears (as per Existing Gear/ Sample) duly Casted/ Fabricated and Cutting Teeth as requited suitable to Accommodate in the Cranes Gear Box for the 2 Ton Capacity/ Sizes of Cranes including Taking down Old Unserviceable Gears, complete all as specified and as directed.

3

-

-

... More
S&F Brass Gears (as per Existing Gear/ Sample) duly Casted/ Fabricated and Cutting Teeth as requited suitable to Accommodate in the Cranes Gear Box for the 10 Ton Capacity/ Sizes of Cranes including Taking down Old Unserviceable Gears, complete all as specified and as directed.

1

-

-

... More
S&F Enclosed Gear Box Helical Type, Splash lubricated with Gears machined and Ground from EN-9 Steel and Pinion from EN-24 duly Hardened suitable for 2 Ton Capacity EOT Crane, having the Coupling between the Gear Box and Motor shall be Geared type and the Coupling shall act as Brake Drum on which Thruster Brake is mounted including Taking down Old Unserviceable Enclosed Gear Box, complete all as specified and as directed.

2

-

-

... More
S&F Enclosed Gear Box Helical Type, Splash lubricated with Gears machined and Ground from EN-9 Steel and Pinion from EN-24 duly Hardened suitable for 10 Ton Capacity EOT Crane, having the Coupling between the Gear Box and Motor shall be Geared type and the Coupling shall act as Brake Drum on which Thruster Brake is mounted including Taking down Old Unserviceable Enclosed Gear Box, complete all as specified and as directed.

2

-

-

... More
S&F Electro-Magnetic Clutch DC Working, Complete Set (Coil Body & Armature Plate) suitable for EOT Cranes/ Hoist for Micro Speed of Hoist including Taking down Old Unserviceable Electro-Magnetic Clutch Complete Set, complete all as specified and as directed.

2

-

-

... More
S&F Pendent Control Box Enclosure of suitable Size for 2 Ton to 10 Ton Capacity EOT Crane and Hoist Pendent Control Housing of Push Button including Taking down Old Unserviceable Control Box Enclosure, complete all as specified and as directed. NOTE : Push Button will be Measured & Paid for separately under relevant Item.

3

-

-

... More
S&F Flame Proof Push Button with Control Element (1 NO + 1 NC) including Taking down Old Unserviceable Control Box Enclosure, complete all as specified and as directed.

15

-

-

... More
S&F Flanged Type Wheel Ball Bearing as per Existing Sample/ Model suitable of Operating of Traveling System for 2 Ton EOT Crane including Taking down Old Unserviceable Wheel Ball Bearing, complete all as specified and as directed.

10

-

-

... More
S&F Flanged Type Wheel Ball Bearing as per Existing Sample/ Model suitable of Operating of Traveling System for 10 Ton EOT Crane including Taking down Old Unserviceable Wheel Ball Bearing, complete all as specified and as directed.

10

-

-

... More
S&F Lifting Chain of 2 Ton Capacity HOT Crane for Smooth Functioning of Crane having the Chain should Load Bearing Capacity of minimum 2500 KG including Taking down Old Unserviceable Lifting Chain, complete all as specified and as directed.

30

-

-

... More
REPAIRS/MAINT TO PASSENGER LIFTS

-

-

-

... More
M&L Comprehensive Maintenance of Electrically Operated Automatic Passenger Lifts of Capacity 10 Passengers/ 680 Kgs, Make : KONE at a Speed of 1.0 Metre/ Second with Automatic Steel Sliding Door upto (G+5 Floors) in SRE Bldg at AIR FORCE STATION - JORHAT, Keeping the Lift and its Accessories in Perfect Working Condition with the Repair and Replacement of Minor Defective/ Worn out Parts/ Components, Lubricating of the Lift including Alarm System without affecting the Normal Functioning of the Lift, etc., complete all as specified and as directed.

12

-

-

... More
Supply only Contactor, 400V AC 50A AC3 3NO, complete all as specified and as directed.

1

-

-

... More
Supply only Coupler, AMD 010 267 X 251 X 20MM, complete all as specified and as directed.

1

-

-

... More
Supply only ERD Sensor Board Assembly, complete all as specified and as directed.

1

-

-

... More
Supply only ERD RFI Assembly, complete all as specified and as directed.

1

-

-

... More
Supply only K-guard W-Surge PCB, 65A Without Phase Sensing, complete all as specified and as directed.

1

-

-

... More
Supply only LCE CCBE Assembly, complete all as specified and as directed.

1

-

-

... More
Supply only PCB, LOPCB, LCE, complete all as specified and as directed.

1

-

-

... More
Supply only PCB-LCECPU NC Board V3F18, complete all as specified and as directed.

1

-

-

... More
Supply only Sensor, Magnet 100 VDC 150 VAC D12M, complete all as specified and as directed.

1

-

-

... More
Supply only Sensor, Magnet 250 VDC 250 VAC 3A D12MM, complete all as specified and as directed.

1

-

-

... More
Supply only 6W LED Round Light, complete all as specified and as directed.

2

-

-

... More
Supply only TL Jones Curtain of Lights, complete all as specified and as directed.

1

-

-

... More
Supply only Maintenance Free Battery, complete all as specified and as directed.

1

-

-

... More
Supply only SMF Battery 12V 12AH, complete all as specified and as directed.

4

-

-

... More
REPAIRS/ MAINT TO PANELS

-

-

-

... More
S&F FRLS PVC insulated PVC Sheathed, Multi-stranded Copper Conductor Cable of Size 6 Sqmm, 4 Core including Taking down Old Unserviceable Cable, complete all as specified and as directed.

200

-

-

... More
S&F Change Over Switch (Open Execution type), 400 Amp, 415 Volt, 4 Pole, 50 Hz including Taking down Old Unserviceable Change Over Switch, complete all as specified and as directed. MAKE : ABB/ HAVELLS/ L&T/ LEGRAND

2

-

-

... More
S&F Change Over Switch (Open Execution type), 630 Amp, 415 Volt, 4 Pole, 50 Hz including Taking down Old Unserviceable Change Over Switch, complete all as specified and as directed. MAKE : ABB/ HAVELLS/ L&T/ LEGRAND

2

-

-

... More
S&F MCB 6 Amp to 32Amp, SP, 'C' Curve with Breaking Capacity 10 kA, 240 Volt including Taking down Old Unserviceable MCB, complete all as specified and as directed.

25

-

-

... More
S&F MCB 63 Amp, TPN, 'C' Curve with Breaking Capacity 10 kA, 415 Volt including Taking down Old Unserviceable MCB, complete all as specified and as directed.

10

-

-

... More
S&F MCCB 160 Amp 4 Pole with Breaking Capacity 36 kA (Adjustable Thermal Magnetic Release Setting), 415 Volt including Taking down Old Unserviceable MCCB, complete all as specified and as directed.

3

-

-

... More
S&F MCCB 250 Amp 4 Pole with Breaking Capacity 36 kA (Adjustable Thermal Magnetic Release Setting), 415 Volt including Taking down Old Unserviceable MCCB, complete all as specified and as directed.

3

-

-

... More
S&F MCCB 400 Amp 4 Pole with Breaking Capacity 36 kA (Adjustable Thermal Magnetic Release Setting), 415 Volt including Taking down Old Unserviceable MCCB, complete all as specified and as directed.

2

-

-

... More
S&F MCCB 630 Amp 4 Pole with Breaking Capacity 50 kA (Adjustable Thermal Magnetic Release Setting), 415 Volt including Taking down Old Unserviceable MCCB, complete all as specified and as directed.

2

-

-

... More
REPAIRS/ MAINT TO CABLES & EARTHINGS

-

-

-

... More
Excavating in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Taking Out/ Laying of UG Electric Cable Lines, etc., Forming Surfaces to required Foundation and getting out in Soft/Loose Soil, complete all as specified and as directed.

65.2

-

-

... More
Returning, Filling in including Spreading, Leveling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps not exc. 150mm Height along the UG Electric Cable Lines/ Route, etc. for future Settling down with Surplus Soil, complete all as specified and as directed.

65.2

-

-

... More
Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description from Trenches, Floors, Walls, GI Protection Pipes, etc. including Serviceable (if any) Cables, Cable Joints, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate.

460

-

-

... More
Supply, Laying & Testing XLPE insulated, PVC Bedded Galvanized Steel Strip Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 300 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevant Items.

210

-

-

... More
Supply, Laying & Testing XLPE insulated, PVC Bedded Galvanized Steel Strip Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 400 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevant Items.

250

-

-

... More
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 230mm Spread thickness (80mm in Depth before Laying the Cable and 150mm in Depth after Laying the Cable) and Consolidated (Punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.

26.08

-

-

... More
S&F Sub-Class B Brick, Well burnt, Laid Breadth-wise along the Length of Cable laid in Trenches over Sand Cushioning laid for UG Cable Protection, complete all as specified and as directed.

1876

-

-

... More
Laying only Old Serviceable Bricks (Serviceable Bricks obtained from Item No. 4.03 here-in-before), Laid Breadth-wise along the length of Cable laid in Trenches over Sand Cushioning laid for UG Cable Protection, complete all as specified and as directed.

700

-

-

... More
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Iron Strip 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Medium grade Protection Pipe, Earth Plate surrounded by a Packed thickness of Char Coal or Coke Dust mixed with Common Salt in Alternate Layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 450x450x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Unserviceable Earthing of any description, complete all as per specified and as directed.

10

-

-

... More
M&L Earthing with Copper Plate Electrode 600x600x3.15mm thick, buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Strip 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Medium grade Protection Pipe, Earth Plate surrounded by a Packed thickness of Char Coal or Coke Dust mixed with Common Salt in Alternate Layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 450x450x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.

10

-

-

... More
DEDUCT/ LESS AGAINST SCHEDULE OF CREDIT

-

-

-

... More
Bidders shall Quote the EQUAL AMOUNT (as per SCHEDULE OF CREDIT including NOTES therein of Tender documents) under Column 'UNIT RATE' (M) against Row No. 101.

1

-

-46201



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.