Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date24 Oct 2024
Closing Soon25 Nov 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only Drivers for LED Flood Light Fittings of 150 W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.

25

-

-

... More
Supply only Drivers for LED Flood Light Fittings of 200W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.

25

-

-

... More
Supply only Drivers for LED Flood Light Fittings of 250W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.

15

-

-

... More
Supply only Drivers for LED High way Light Fittings of 100 W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.

15

-

-

... More
Supply only Drivers for LED High way Light Fittings of 150W Capacity, 230 Volts, 50 Hz complete all as specified and as directed.

15

-

-

... More
S & F in repairs Energy efficient LED Flood Light fitting, 250 W with Pressure Die Cast Aluminium Housing, IP66 Protection and secondary lens optics , Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver including clamp, nut, bolt and other accessories and connecting up with three core PVC insulated, sheathed flexible copper cable , including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed.

10

-

-

... More
S & F in repairs Energy efficient LED Flood Light fitting, 200 W with Pressure Die Cast Aluminium Housing, IP66 Protection and secondary lens optics , Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver including clamp, nut, bolt and other accessories and connecting up with three core PVC insulated, sheathed flexible copper cable , including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed.

10

-

-

... More
S & F in repairs Energy efficient LED Flood Light fitting, 150 W with Pressure Die Cast Aluminium Housing, IP66 Protection and and secondary lens opticSurge Protection Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver including clamp, nut, bolt and other accessories and connecting up with three core PVC insulated, sheathed flexible copper cable , including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed.

10

-

-

... More
S & F in repairs Energy efficient LED Flood Light fitting, 100 W with Pressure Die Cast Aluminium Housing, IP66 Protection and secondary lens optic, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver including clamp, nut, bolt and other accessories and connecting up with three core PVC insulated, sheathed flexible copper cable , including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed.

11

-

-

... More
S & F in repairs Energy efficient LED Flood Light fitting, 50 W with Pressure Die Cast Aluminium Housing, IP66 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver including clamp, nut, bolt and other accessories and connecting up with three core PVC insulated, sheathed flexible copper cable , including taking down existing Light Fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed.

10

-

-

... More
Supply and fixing in repair Energy efficient LED highbay Light 100 W, IP66 , PC diffuser with inbuilt surge protection 4KV and external 10 KV, suitable for Existing hangar Ceiling /shed with suitable size necessary fitting and fixture(hook/suspended rod of reqired size) existing electric incoming cable ,incl taking down old u/s complete all as specified and as directed.

14

-

-

... More
Supply and fixing in repair Energy efficient LED highbay Light 120 W, IP66 , PC diffuser with inbuilt surge protection 4KV and external 10 KV, suitable for Existing hangar Ceiling /shed with suitable size necessary fitting and fixture(hook/suspended rod of reqired size) existing electric incoming cable ,incl taking down old u/s complete all as specified and as directed.

13

-

-

... More
Supply and fixing in repair Energy efficient LED highbay Light 150 W, IP66 , PC diffuser with inbuilt surge protection 4KV and external 10 KV, suitable for Existing hangar Ceiling /shed with suitable size necessary fitting and fixture(hook/suspended rod of reqired size) existing electric incoming cable ,incl taking down old u/s complete all as specified and as directed.

12

-

-

... More
Comprehensive repair/maintenance electric operating system with gear and 3 phase 415 V for rooling shutter motor Dismantling the electrical connection from system and removing out the Induction Motor and Gear Box for Reconditioning /Overhauling Completely Transporting the Induction Motor capacity upto 1 HP to civil work shop and strip opening the motor and removing out the burnt out winding and cleaning of the stator core and rewinding with suitable size super enameled copper wire with necessary insulations and varnishing becking and replacement of unserviceable ball bearing and assembling back the motor and re -fixing with gear Box and necessary electrical connections and testing and commissioning the rolling shutter all as specified and as directed.

1

-

-

... More
M&L for complete servicing of high mast light of any height and description for general checking, mechanical parts and electrical system maintenance complete all as specified and as directed for the followings :- (a) Checking and repair of head frame of the high mast poles fitted with wire ropes and cables. (b) Checking and repair of gear box for seal leakage. (c) Checking and repair of lift cables for frayed strands (d) Testing and repairing of lowering device and fully operate to fully down position. (e) Repair and maintenance of any mechnical devices as required. (f) Checking and repairing of all electrcial devices. (g) Checking and repair of luminaires box, control gear and junction box nad tightened properly. (h) Checking and reparing of all screws and nuts properly.

4

-

-

... More
M&L for taking out burnt winding of 3 phase power tool electric motor of high mast fittings from any position, re-winding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning on reinstating complete all as specified and as directed. Note : Quoted rate shall be deemed to be inclusive of any minor spares/parts.

3

-

-

... More
Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable etc all as specified and as directed by the Engineer-in-charge.

9

-

-

... More
Dismantling taking down old unserviceable submain wiring 3 phase any type complete all as specified and as directed.

180

-

-

... More
Material and labour for sub main wiring with 4x 4 sq mm single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2x 2.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with including cutting chases pinning and making good disturbed surface complete all as specified and as directed.

90

-

-

... More
Material and labour for sub main wiring with 4x 6 sq mm single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2x4 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with including cutting chases pinning and making good disturbed surface complete all as specified and as directed.

90

-

-

... More
Dismantling taking down old unserviceable submain wiring any type complete all as specified and as directed.

270

-

-

... More
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.

60

-

-

... More
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.

60

-

-

... More
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.

60

-

-

... More
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and Existing/ New , concealed/surface PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning and making good disturbed surface complete all as specified and as directed.

90

-

-

... More
Dismantling taking down old unserviceable MCB DB/MCB DB TPN any type complete all as specified and as directed.

3

-

-

... More
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as incl taking down old u/s specified and as directed .

3

-

-

... More
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8way with dim rail earth and neutral bar all as specified and as directed.

6

-

-

... More
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4way with dim rail earth and neutral bar all as specified and as directed.

4

-

-

... More
Dismantling taking down old unserviceable MCB FP/MCB DP ,SP any type complete all as specified and as directed.

68

-

-

... More
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position all as specified and as directed.

16

-

-

... More
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacity all as specified and as directed.

16

-

-

... More
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position incl taking down old u/s all as specified and as directed.

36

-

-

... More
Supplying and fixing 1100 volts grade,heavy duty cable with PVC insulated, aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 4 sqmm with IS 694: 2010,complete all as specified and as directed.Make: Richa/Plaza/Havells

150

-

-

... More
Supplying and fixing 1100 volts grade,heavy duty cable with PVC insulated, aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 6 sqmm with IS 694: 2010,complete all as specified and as directed.Make: Richa/Plaza/Havells

150

-

-

... More
Supply and fixing in Repair upto 36 W LED Power Driver for Downlighters all as specified and as directed.

12

-

-

... More
Supply and fixing in Repair Upto 24 W LED Power Driver for Downlighters all as specified and as directed.

12

-

-

... More
S&F in Repair Recess Mounting luminaris LED downlighter of 36 W white in the shape of Square 2' x2' feet complete , all as specified and as directed .

8

-

-

... More
Supply, fixing in Repair and cable junction boxes of size 155mm x 210mm x 92mm IP 66 for cable entry, comprising of SPN aluminium bus bar of capacity 16 Amp 230 Volt fixed , making holes on strips for connecting cables and fixed to garden light pole with and including MS clamp of size 25mmx5mm incl nut ,bolt, washer and and including prvn of MCB SP 6 A, C curve 10kA breaking capacity with mounting rail all as specified and as directed.

4

-

-

... More
Attending to checking the serviceablity of Distribution panel board for SPS power supply 115/208 V,400 Hz ,3 phase any capacity of busbar MCCB ,with digital Voltmeter & ammeter by only auth OEM rep/team for fault finding incl attending repairs as and when required such as repairing,starting, the operating parameter of the DB for SPS panel checking any calibration till smooth running the a required parameter of incl minor Spare parts entire satisfaction of user /dep. attending break down inspection service report duly mentioning the date of inspection signature of service engineer, engineer -in- charge shall be submitted for claming payment ,as required in ground as ordered by Engr-in-charge.

2

-

-

... More
Attending to checking the serviceablity of Distribution panel board for SPS power supply 28/36 V DC,1 phase any capacity of busbar MCCB ,with digital Voltmeter & ammeter by only auth OEM rep/team for fault finding incl attending repairs as and when required such as repairing,starting, the operating parameter of the DB for SPS panel checking any calibration till smooth running the required parameter of incl minor Spare parts entire satisfaction of user /dep. attending checking inspection service report duly mentioning the date of inspection signature of service engineer, engineer -in- charge shall be submitted for claming payment ,as required in ground as ordered by Engr-in-charge.

2

-

-

... More
Attending to checking the serviceablity of Distribution panel board for UPS DB , power supply any capacity of busbar MCCB ,with digital Voltmeter & ammeter by only auth OEM rep/team for fault finding incl attending repairs as and when required such as repairing,starting, the operating parameter of the UPS DB for UPS panel checking any calibration till smooth running the a required parameter of incl minor Spare parts entire satisfaction of user /dep. attending checking inspection service report duly mentioning the date of inspection signature of service engineer, engineer -in- charge shall be submitted for claming payment ,as required in ground as ordered by Engr-in-charge.

2

-

-

... More
M&L for checking the serviceability including loose contact and condition of cable terminations of all the existing Junction Box ,MCB DB, MCCB TPN DBs at any building/Hangar any place once in three months and opening a junction Box / DBs serviceability register and recording location wise complete all as specified and as directed. Note:- The checking shall be carried out in presence of user/user rep. One time checking including entering in the register is considered as one job.

8

-

-

... More
Material and Labour for repairs and maintenance of UPS with charging and top up distilled water/ connector accessories in UPS batteries to maintain necessary specific gravity with replacement of damaged battery lead clamps and worn out leads including taking down and fixing of batteries to its position complete all as directed and specified by Engr-in-charge

15

-

-

... More
Supply and fixing on wall security light 25/32 mm GI bracket medium grade 1.5 m long bent to shape including bolt, nut,washer,clamp etc incl taking out old u/s all as specified and as directed by the Engineer-in-charge.

5

-

-

... More
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.

2

-

-

... More
Comprehensive Service/Repair/maintenance/including spares and monthly visit for regular maintenance for the Automation of Wireless SCADA based temperature and Humidity monitoring system) (MAKE: CIMCON) of air conditioning plant installed at MES office at WSA Air force station Chabua by one factory trained Technician/Software Engineer. The scope of work includes carrying out complete maintenance/ servicing/ repairs as required of all the above sub systems viz. RTU based control panels (with all the accessories), RTD sensors, Humidity sensors, communication MODEM (with all its accessories) Humidity indicator, Temperature indicator, SCADA system etc. (with all its accessories), breakdown maintenance as and when required complete all as specified and directed by Engr-In-Charge. More over details of servicing are as under. (a) Servicing iRTU Panel i/e cleaning, checking for wear and tear, checking electrical termination, testing, as directed by Engr-In-Charge (once every month) and breakdown maintenance as and when required. (b) Servicing Temp. sensor i.e.. cleaning, checking for wear and tear, checking electrical termination ,testing, as directed by Engr-In-Charge (once every month) and breakdown maintenance as and when required. (c) Servicing Humidity transmitter i.e.. cleaning, checking for wear and tear, checking electrical termination, testing, as directed by Engr-In-Charge (once every month) and breakdown maintenance as and when required. (d) Servicing Humidity and temperature indicator i.e.. cleaning, checking for wear and tear, checking electrical termination, testing, as directed by Engr-In-Charge (once every month) and breakdown maintenance as and when required. Note:- (i) Cost of new components shall be paid for separately under relevant items

6

-

-

... More
Comprehensive Service/ Repair/ maintenance and monthly visit for regular maintenance for the Automation of intelligent addressable fire alarm control panel and flowchart based programmable RTU at tech flight hanger, 102 SQN hanger, Logistic Hanger , BCR Building, AFNET site -2, and EE hall and BD 1, 2, 3, 4& 5 including checking testing and cleaning of Loop card ,Main board, LCD display, Printer Panel, AC filter, Transformer, Lead acid batteries, Invertor, Multisensor, sounder, MCP, Beam Detector, Repeater Panel, Zone monitor Module, UV&IR detector, Remote Response indicator, Loop Isolator, Amplifier and Loud speakers carrying out normal repairs for the trouble free and efficient functioning of the entire fire alarm system by providing one engineer for Monthly visit all as directed AND AS PER SPECIFIED NFPA 72 and Guidelines. Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" (ii) Contractor's rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the user.

6

-

-

... More
Dismantling, Servicing of multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling every six month complete all as specified and as directed

300

-

-

... More
Serviceability and testing of inverter as and when directed complete all as specified and as directed.

6

-

-

... More
Serviceability and Testing of Beam detector and its transmitter and receiver alignment with testing kit as and when directed complete all as specified and as directed.

5

-

-

... More
Serviceability and Testing of UV & IR flame detector and its alignment to detect flame with Testing Kit as and when directed complete all as specified and as directed.

6

-

-

... More
Supply of GSM SIM card services with validity SMS packs for 11 months for control & monitoring charges. Note:- GSM service provider shall be chosen (as per network availability) by Engr-in-Charge.

6

-

-

... More
Supply & fix in repairs 12 V, 42 AH battery for Inverter supply for back up to all FACP and RTU panel complete all as specified and as directed. Make: EXIDE/AMAR RAJA/AMCO/AMARON

4

-

-

... More
Supply only of PUSH BUTTON WITH NO CONTACT (BLACK) complete all as specified and as directed. Make: ESBEE or Equivalent

1

-

-

... More
Supply only of GST200-2 Main Board F2.908.826a for FACP complete all as specified and as directed. Make: GST or Equivalent

2

-

-

... More
Supply only of LCD Screen CGM12864 for FACP complete all as specified and as directed. Make: GST or Equivalent

2

-

-

... More
Supply only of GST200 Rubber Keypad F7.843.249 for FACP complete all as specified and as directed. Make: GST or Equivalent

2

-

-

... More
Supply only of GST200 Loop Interface Board F2.908.828 (RoHS) for FACP complete all as specified and as directed. Make: GST or Equivalent

2

-

-

... More
Supply only of GST200 Power Supply Unit F2.932.069 (20100682) for FACP complete all as specified and as directed. Make: GST or Equivalent

2

-

-

... More
Supply only of Transformer 220V/27V-100W-R for FACP complete all as specified and as directed. Make: GST or Equivalent

2

-

-

... More
Supply only of PRN-6 printer, for FACP complete all as specified and as directed. Make: GST or Equivalent

1

-

-

... More
Supply only of two core copper conductor of size 1.5sqmm FRLS flexible shielded cable complete all as specified and directed.

50

-

-

... More
Supply & fix in repairs Printer Cartridge and Printer Paper Roll complete all as specified and as directed.

3

-

-

... More
Supply & Fix in repair of 12V /7 AH Battery complete all as specified and as directed. Make: EXIDE/AMAR RAJA/AMCO/AMARON

4

-

-

... More
Supply and Install, wireless modem suitable for GSM/GPRS based communication system, dual band GSM900 and GSM1800, compliant to GSM phase 2/2+ Class 4 (2W@ 900 MHz) Class 1 (1W@ 1800/1900MHz), control via AT commands (GSM 07.07 ,07.05 and enhanced AT Commands), with SIM application toolkit, complete all as specified and directed. Make:Visiontek (Link well Telesystems Pvt. Ltd.)/Safety/ Siemens/L&T/Schneider/ Motorola/Cimcon

1

-

-

... More
Supply and Install, Resistant Temperature Detector (RTD) Sensor with Transmitter (Signal Converter), three wire system, range 0°C to 200°C, accuracy Class ‘B’ (Tolerance as per IEC 751), suitable for measurement of room temperature (Inside the Room and Duct), complete all as specified and directed. Make – L&T/ Siemens/ Schneider/ Baumer/ Radix/ Masibus/Wika

1

-

-

... More
Supply and Install, surface mounted, humidity sensor with transmitter (Signal Converter), working range 0°C to 50°C & 0-100%RH, transmitter output 4-20mA (two wire), accuracy at 25°C ± 2% RH (0 to 90%) ; ± 3% RH (90 to 100%), suitable for measurement of Humidity inside room, complete all as specified and directed. Make – L&T/Siemens/Schneider/ Masibus/Wika / Baumer / Radix

1

-

-

... More
Supply and Install, Process Indicator of minimum size 48x48 mm, with retransmission output for monitoring of temperature and humidity, complete all as specified and directed. Make – Multispan/Radix/Masibus

1

-

-

... More
Supply and Install in repair UPS, 360 Watts /600 VA, Input 230V, Output 230V 600VA with minimum 15 minutes Backup, complete all as specified and directed. MAKE : APC Model No. BX600CI-IN or equivalent Model in Microtek/Su Kam/Luminious

1

-

-

... More
Supply and Install, Programming, Testing and Commissioning of Supervisory Control and Data Accusition (SCADA) software development Version with required tags for Central Monitoring and control through wireless communication for Master Control Station, including programming liberty generation, soft keys etc.for graphical display of parameters for control and multilevel password protection, complete all as specified and directed. Make: MC WorX/ GE FANUC/ ROCKWELL AUTOMATION/ L&T/Seimens/Schneider/ CIMCON / Safetek/ Powertek

1

-

-

... More
Supply Only, GSM SIM Card with prepaid Rental and SMS charges for data usage only without talk time, inclusive of all taxes and charges of service operator, for a period of 8 (eight) months for 02 (Two) Nos sim cards complete all as specified.

2

-

-

... More
SUPPLY and install/renew COMPUTER ANTI VIRUS SOFTWARE complete all as specified and directed.

1

-

-

... More
Supply of RTU logic upgradatin and development for central monitoring through wireless communication at master control station which includes the development of logic for false alarm which comes from addressable fire alarm control panel.

3

-

-

... More
Supply and Fixing in repair or replacement of Indoor addressable detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence complete all as specified and as directed. Make:- GST/COOPER/BOSCH/SEIMENS

15

-

-

... More
Supply only of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A , c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key, d) Ingress Protection IP-43 & Material-ABS Make:- GST/COOPER/BOSCH/SEIMENS

5

-

-

... More
Supply only of the annunciating device Remote response indicator complete all as specified and directed. Make:- GST/BOSCH/SEIMENS

2

-

-

... More
Supply only of fire alarm sounder/sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range complete all as specified and directed. Make:- GST/COOPER/BOSCH/SEIMENS

1

-

-

... More
Supply, Install, Testing & Commissioning of Wireless modem suitable for GSM based communication system to be mounted in RTU enclosure shall be installed at all proposed buildings complete all as specified and directed. Make:- CIMCON/MOTOROLA/SIMOCO/SEIMENS

1

-

-

... More
Supply only of Amplifiers suitable 30-60 Watts, 230 VAC 50 Hz complete all as specified and directed. Make: AHUJA/BOSCH/PHILLIPS

4

-

-

... More
Supply and Fixing wall mounted loudspeaker 10 watt 230V AC, 50Hz of sturdy design weather proof type re-entrant horn type loudspeaker for operating under rough conditions complete all as specified and directed. Make: AHUJA/BOSCH/PHILLIPS

1

-

-

... More
Supply only of the indoor detector complying with and type certified to EN - 54 Addressable type flame detectors with UV and IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module) with self built intelligence complete all as specified and directed. Make: SIEMENS/AGNI/GST/HONEYWELL

5

-

-

... More
Supply only of Zone Monitor Module compatible with Fire Alarm Control Panel complete all as specified and as directed. Make: GST/COOPER/BOSCH/SEIMENS

2

-

-

... More
Supply only of optical beam detector Transmitter and receiver type including testing complete all as specified and directed. Make: GST/COOPER/GODREJ/AGNI

1

-

-

... More
Supply only 24 V DC Power Supply Unit of RTU complete all as specified and as directed. Make: CIMCON/SIEMENS/ABB

2

-

-

... More
Supply only 12/5 V DC Power Supply Unit of RTU complete all as specified and as directed. Make: CIMCON/SIEMENS/ABB

2

-

-

... More
Supply only CPU card of RTU complete all as specified and as directed. Make: CIMCON/SIEMENS/ABB

2

-

-

... More
Supply only Analog and Digital I/O Card of RTU complete all as specified and as directed. Make: CIMCON/SIEMENS/ABB

2

-

-

... More
Supply only DI/AI Termination PCB of RTU complete all as specified and as directed. Make: CIMCON/SIEMENS/ABB

2

-

-

... More
Supply only of Display and Keyboard of RTU complete all as specified and as directed. Make: CIMCON/SIEMENS/ABB

2

-

-

... More
Supply only of MCB 6A SP complete all as specified and as directed. Make: LEGRAND/HAVELLS INDIA LTD/HAGER/ INDOASIAN/C & S ELECTRIC LTD/ABB/L & T/SCHNIEDER/GE

2

-

-

... More
Supply only of LEDs (Red/Green) for RTU Panel complete all as specified and as directed. Make: SAFETEK/CIMCON/POWERTEK

2

-

-

... More
Supply only of Relay card : 8 relay 1 c/o for RTU panel complete all as specified and as directed. Make: SAFETEK/CIMCON/POWERTEK

1

-

-

... More
Supply only of Isolation transformer—300 VA for RTU panel complete all as specified and as directed. Make: SAFETEK/CIMCON/POWERTEK

1

-

-

... More
Supply and fixing RS 485 network card as complete all as specified and as directed. Make GST, Honeywell

5

-

-

... More
Supply and installing the programmable RTU alongwith battery back up and wireless modem suitable for GSM/GPRS based communication system, to be mounted in RTU enclosure with the following:- (a) Input/Output as per requirement (b) 2 Ethernet Port (c) Digital Inputs(Optical Isolation) (d) Digital Outputs (e) Isolated Analog Inputs (f) Local display, Membrane key board and data storage (g) Compatability with GSM modem (h) Power Supply SMPS 24 Volt 2 Amp-01 No.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.