Military Engineer Services Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Mar 2025
Closing Date29 Mar 2025
Tender Amount₹ 45,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for providing sand cushioning to UG cable, 8 cm thick laid before laying of cable and 15 cm thick after laying of cable punned down to total thickness of 18 cm in trenches with clean dry sand of approved quality, suitable for sand cushioning complete all as specified and directed. Note: Punned thickness only shall be measured and paid.

68

-

-

... More
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class HV, Type I , flat size 300 mm X 180 mm X 40 mm in trenches as protection to HT UG cable complete all as specified and directed.

4200

-

-

... More
M&L for making hole by suitable means for insertion of GI pipe 80 mm bore for passing cable across the road without cutting the road complete all as specified and directed.

40

-

-

... More
Supply, laying, connecting and testing XLPE HT UG insulated(Earthed),cable laid in trenches/fixed on pole etc with screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with stranded aluminium conductor, 11000 volts grade, cross sectional area 95 sqmm,3 core conforming to IS-7908(Part-I)1988, laid in trenches/down through pipe fixed to walls/poles or laid under roads/drains/path/culverts complete of following sizes complete all as specified and directed. Note:Excavation & earth work shall be measured and paid seperately.

600

-

-

... More
M & L for replacement of cable jointing kit for 11 kV grade (Earthed) HT cable for outdoor end termination heat shrinkable type complete with jointing material and accessories suitable for 95 sqmm 3 core XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed.

6

-

-

... More
M & L for replacement of galvanised tubing light grade including taking down, laid in trenches or fixed to pole and / or laid under road in any position with necessary clamp nut and bolt etc of 100 mm bore size completed all as specified and directed.

54

-

-

... More
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation for filling in mass concrete for pole and stay complete all as specified and directed.

7

-

-

... More
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping of pole etc including form work complete all as specified and directed.

2.5

-

-

... More
Supply, errecting, and fixing steel tubular swaged pole 11.00m long Type -410 SP-55 conforming to IS-2713 part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. and fixed into plain cement concrete foundation duely painted with two coats of aluminium paint over one coat of red oxide primer including preparetion of surfaces and making strip 150mm wide upto 1.50m (above PCC coping) by black, yellow paint in alternate layers and pole nos. including dismantling of old poles of any description including demolition of concrete foundation complete all as specified and directed. NOTE: Cement concrete will be measured and paid seperately.

17

-

-

... More
M & L for replacement, of vertical switch air break gang operated HT 11 KV triple pole mechanically operated out door type and rated capacity 200 Amp with 12 insulator and steel frames mechanically operated mechanism consisting of three male contacts & three female contacts of tinned copper, three arching horns, three MS jumper carrier equipped with braided copper belt, operating rod of medium grade 32/25mm bore GI pipe of suitable length worked from ground level with locking arrangement with clamp of flat iron 50X6 mm complete and testing on load all as specified and directed.

6

-

-

... More
Suply and fix in replacement swing out expulsion fuse type drop out fuse mounted on two nos of HT insulators single pole upto 25 Amps & upto 50 Amps HT 11 KV with spring mechanism complete including connecting with HT cable leads spirally shaped duly crimped with suitable size lugs complete all as specified and directed.

6

-

-

... More
M & L for replacement of Cross arms bracing supports clamps and back plate fabricated from structural steel section including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape & size as indicated or directed and including of one primer coat one under coat one finishing coat with saluminium paint includin taking down old unserviceable cross arms.complete all as per specified and directed.

7.5

-

-

... More
M & L for replacement of pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed.

8

-

-

... More
S&F in replacement disc type insulator porcelain vitrcelain vitreous 145mm high and 255mm dia ball and socket type, white,brown or green single disc for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.

8

-

-

... More
M & L for replacement of lightening arrester expulsion type complete with all fittings ,transmission class discharge capacity 65 KA conforming to IS 3070 Part II of for HT 11000 of Volt complete all as specified and directed.

4

-

-

... More
M & L for replacement of danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled/ painted white with letters figures and conventional skull and bones in signal red colour and fixed with M.S. clmps , bolts and nuts of approved size, for HT of size 25 X20 cm complete all as specified and directed.

24

-

-

... More
S& F in replacement male contact or moving contact blade made out of Brass suitable for 11 KV GO/DO air break switch assembly complete all as specified and directed.

3

-

-

... More
All as per item No. 20.00 here-in-before but female contact or fixed contact jaw complete all as specified and directed.

3

-

-

... More
All as per item No. 20.00 here-in-before but pin insulator straight/tilted type complete all as specified and directed.

3

-

-

... More
M&L for repairing & servicing with primary and secondary injection and check up / maintenance/ calibration of relays Short circuit / Earth / Over load etc of 11 KV HT VCB by taking out the enclosure including all components and cleaning the bus bar complete & refixing the same after duly repaired and replacement of unserviceable components/parts complete to keep the same functional complete all as specified and directed. (Note:- New Spare/Parts shall be measured and paid separately under relevant item Nos. 24.00 to 32.00 as “Supply only”)

5

-

-

... More
Supply only Vaccum Interrupter/Vaccum bottle 440 Volts as per existing make and as approved complete all as specified and directed.

5

-

-

... More
Supply only Spring charging motor, 250 Watt, 240 Volts, AC as per existing make as approved complete all as specified and directed.

5

-

-

... More
Supply only Breaker Control switch with spring return and sequence device, 32 Amps, 440 Volts as per existing make as approved complete all as specified and directed.

5

-

-

... More
Supply only Closing spring, 440 Volts of existing make complete all as specified and directed.

5

-

-

... More
Supply only power pack of existing make complete all as specified and directed.

5

-

-

... More
Supply only trolley chamber of existing make complete all as specified and directed.

1

-

-

... More
Supply only Contactor, capacity 240 Volts, 4NO + 4 NC, 10 Amps as per existing make complete all as specified and directed.

5

-

-

... More
Supply only 100 Ah battery, dry type (for battery bank) complete all as specified and directed.

5

-

-

... More
Supply only Insulator of VCB chamber of existing make complete all as specified and directed.

3

-

-

... More
S&F in repair on Load changeover 630 Amps, 50 KA, 415 Volts, 4 Pole with adjustable thermal & adjustable magnetic setting complete as specified and directed.

1

-

-

... More
S&F in repair, MCCB 630 Amps, 415 Volt, 50 KA, 4 pole with adjustable thermal & magnetic trip setting unit complete all as specified and directed.

1

-

-

... More
S&F in repair, MCCB 400 Amps, 415 Volt, 36 KA, 4 pole with adjustable thermal & magnetic trip setting unit complete all as specified and directed.

1

-

-

... More
Supply and laying in replacement synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.

10

-

-

... More
M&L, in repair, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii] Main earthing lead from earth electrode to test point upto 7.5 mtr. [iv] Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.

16

-

-

... More
M&L for repairing the transformer of any capacity including transporting from site to outside workshop, required T&P and back to site after repairing and re-install, reconnection in the system and testing at site complete all as specified and directed.

16

-

-

... More
Material and labour for cleaning of surface of the transformer of capacity 11 KV/433V of capacity 50/63KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paint suitable to the existing colour all as specified and directed.

4

-

-

... More
Material and labour for cleaning of surface of the transformer of capacity 11 KV/433V of capacity 100 KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paint suitable to the existing colour all as specified and directed.

4

-

-

... More
Material and labour for cleaning of surface of the transformer of capacity 11 KV/433V of capacity 160KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paint suitable to the existing colour all as specified and directed.

6

-

-

... More
Material and labour for cleaning of surface of the transformer of capacity 11 KV/433V of capacity 200 KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paint suitable to the existing colour all as specified and directed.

4

-

-

... More
Material and labour for cleaning of surface of the transformer of capacity 11 KV/433V of capacity 250 KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paint suitable to the existing colour all as specified and directed.

10

-

-

... More
Material and labour for cleaning of surface of the transformer of capacity 11 KV/433V of capacity 500 KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paint suitable to the existing colour all as specified and directed.

2

-

-

... More
Material and labour for dehydration and filtration of installed transformer oil to achieve the di-electric strangth up to 40 KV and minimum of 30 KV with 4 mm gap (for one minute duration) between testing electrodes complete all as specified and directed. Note: (i) The contractor has to arrange the de-hydration cum filtration plant with oil hose of sufficient length to reach up to the transformers/ switch gears and the oil di-electric strength testing machine. (ii) Dehydration & filtration of oil transformers shall be carried out ON-Line. Shut down will be given for making necessary pipe/ hose line connections from machine to transformer.

5000

-

-

... More
Supply and topping up fresh Transformer oil having di-electric strength 40 KV into the transformers and the HT switch gears complete all as specified and directed.

1700

-

-

... More
Supply and fix in repair breather for transformers oil conservator bank of capacity from 50 KVA to 150 KVA as required complete all as specified and directed.

14

-

-

... More
Supply and fix in repair breather for transformers oil conservator bank of capacity from 200 KVA to 500 KVA as required complete all as specified and directed.

17

-

-

... More
Material and labour for replacement of oil level glass for transformer capacity from 50 KVA to 150 KVA as required at site complete all as specified and directed.

6

-

-

... More
Material and labour for replacement of oil level glass for transformer capacity from 200 KVA to 500 KVA as required at site complete all as specified and directed.

8

-

-

... More
Material and labour for replacement of HT metal parts & HT bushing suitable for indoor/outdoor type transformer of capacity 50 KVA to 150 KVA (for three phases) as required at site complete all as specified and directed.

4

-

-

... More
Material and labour for replacement of HT metal parts & HT bushing suitable for indoor/outdoor type transformer of capacity 200 KVA to 500 KVA (for three phases) as required at site complete all as specified and directed.

4

-

-

... More
Material and labour for replacement of LT metal parts & LT bushing suitable for out door of capacity 50 KVA to 150 KVA (for three phase & neutral) as required at site complete all as specified and directed.

4

-

-

... More
Material and labour for replacement of LT metal parts & LT bushing suitable for Indoor\out door of capacity 200 KVA to 500 KVA (for three phase & neutral) as required at site complete all as specified and directed.

8

-

-

... More
Supply only LT leg coil of copper conductor for transformer of capacity 50 to 500 KVA complete with insulation, varnishing by vacuum impregnation and baking coil assembly, etc. as required complete all as specified and directed. Note - weight of LT leg coil shall be measured and paid as per actual measurement on ground .

405

-

-

... More
Supply only HT leg coil of copper conductor for transformer of capacity 50 to 500 KVA complete with insulation, varnishing by vacuum impregnation and baking coil assembly, etc. as required complete all as specified and directed.. Note - weight of HT leg coil shall be measured and paid as per actual measurement on ground.

405

-

-

... More
M&L for disconnecting the electrical connection of HT and LT side of defective transformer, the same from its position and install the serviceable Transformer (any capacity) and connect the electrical connection of HT & LT both side complete all as specified and directed.

12

-

-

... More
Overhauling of step down transformer of various make 11/433V and 11/0.433 KV by disconnecting LT/HT terminals, decanning transformer oil complete removing sludge, cleaning of LT, HT bushings, complete cleaning and removing the dust particles, cleaning the core and blowing with compressed air and reassemble complete including replacement of copper washers, rubber bushes of LT, HT bushings, replacement of bushes HT < if necessery, replacement of corksheet of 6 mm thick suitable for transformer top cover, terminal boxes, refilling the transformer oil and topping up with new transformer oil and filtration to achieve the di-electric strength upto 60 KV, testing and commissioning on load complete for the transformer 11 KV/433V of capacity 50/63KVA complete all as specified and directed. (Note: Filtration and new oil, HT < bushings will be measured and paid seperately).

2

-

-

... More
All as per item No. 58.00 here-in-before for transformer 11 KV/433V of capacity 100 KVA

2

-

-

... More
All as per item No. 58.00 here-in-before for transformer 11 KV/433V of capacity 160 KVA

2

-

-

... More
All as per item No. 58.00 here-in-before for transformer 11 KV/433V of capacity 200 KVA

2

-

-

... More
All as per item No. 58.00 here-in-before for transformer 11 KV/433V of capacity 250 KVA

6

-

-

... More
All as per item No. 58.00 here-in-before for transformer 11 KV/433V of capacity 500 KVA

2

-

-

... More
Installation of transformer of same capacity or higher capacity (upto 500 KVA) in place of unserviceable transformer (which found major repair and taking to wksp for repair), on hire basis for maximum period of 10 days when ordered complete all as specified and directed. Note:- Repairing of transformer have to be completed with in 10 days duration, no extra cost will be paid toward hiring charges beyond 10 days. Moreover contractor will not be allowed to shift the hired transformer until it is replaced by the repaired transformer. Any thing goes wrong in the hired transformer, no extra cost will be paid towards repairing of hired transformer. Contractor should check the available infrastructure and to be sure regarding safety of transformer before installation. The rate quoted is deemed to be included transportation cost, connecting incoming & outgoing cables, earthing leads lifting/lowering arrangement, labour etc.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.