Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 81,900Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660366_1Bid Award Id
ViewTender No
8503/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in fixing of hold fast including necessary form work as required complete all as specified and directed.
0.5
-
-
M&L preparing surface of wood and wood based materials, and new or old of any description and girth,not otherwise described and treated with applying two coats of creosote oil,complete all as specified and as directed.
3
-
-
S&F 2nd class hard wood plain solid, straight chowkats and frames , wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
1.04
-
-
S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed
48
-
-
S&F 35 mm thick factory made,2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(a), complete all as specified and as directed.
32
-
-
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed.
76.8
-
-
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part I, Section 8 complete all as specified and as directed.
22.4
-
-
S&F powder coated Anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc. complete all as specified and directed
Note:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
237
-
-
S&F Powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified
Note:-(i)Glass/wire guage/Particle board as required shall be measured and paid seperately under appropiate item
(ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
64.32
-
-
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer and dismantling of mild steel work of any description complete all as specified and directed.
1280
-
-
S&F 4mm thick plain sheet glass,ordinary quality fixed with Aluminum frame work not exc 0.5 sqm in each pane complete all as specified and as directed.
56.97
-
-
S&F 4mm thick plain sheet glass, frosted on one side, ordinary quality fixed with Aluminum frame work not exc 0.5 sqm in each pane complete all as specified and as directed.
6.4
-
-
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
66.07
-
-
S&F 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to Aluminum frame work/Cupboard complete all as specified and as directed.
40
-
-
S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed .
48
-
-
S&F 100mm Butt hinges, Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed .
120
-
-
S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed.
112
-
-
S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
112
-
-
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
16
-
-
S&F in repair, Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
76.8
-
-
S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let ball valve float and handle, PVC flush pipe, complete all as specified and as directed.
8
-
-
S&F in repair Vitreous China wash down water closet pan, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
8
-
-
S&F PVC connection 15mm size with PTMT nuts, 450mm long complete all as specified and as directed.
24
-
-
S&F in repair, vitreous China pedestal wash basin, white, flat back, size 550x400mm including brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed.
8
-
-
S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
8
-
-
S&F in repair 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed
8
-
-
S&F in repair, sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
8
-
-
S&F in repair, 0.63mm thick stainless steel Kitchen rack, overall size 1050mm x 750mm x 250mm complete all as directed.
8
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/rubbish outside the permises complete all as specified and directed.
420
-
-
M&L Glazed ceramic coloured tiles in vertical surfaces 450x 300x 7 mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed.
205
-
-
M&L premimum quality Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed.
54.4
-
-
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed.
160.48
-
-
M&L Granite (of any type) tiles 18-20mm thick machine cut, floor laid bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including including 20 mm thick Screed bed or bedding layer of cement mortar 1:6 including demolition of stone slab and tiles of any description laid bedded and pointed in any cement mortar, complete all as specified and directed.
6.48
-
-
M&L for 18-20 mm thick machine cut Kota stone slab as in flooring over and including 20 mm thick screed bed in cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including demolition of stone slab and tiles of any description laid bedded and pointed in any cement mortar and complete all as specified and as directed.
42.8
-
-
M&L for 18-20 mm thick machine cut Kota stone slab as in vertical surfaces such as skirting/dado etc over and including 15 mm thick screed bed in cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including demolition of stone slab and tiles of any description laid bedded and pointed in any cement mortar and complete all as specified and as directed.
7
-
-
Demoliation of cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
6.38
-
-
M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
85
-
-
M&L 100mm thick cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate as Path/hardstanding finished even and fair complete all as specified and directed.
40
-
-
M&L Pre-polished chequered cement concrete tiles of 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over cement screed 20 mm thick in cement mortar 1:6 complete all as specified and as directed.
40
-
-
M&L 15mm thick plaster of cement mortar (1:3) rendering on brick work or concrete surfaces of sunken slab mixed with and including water proofing compound as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed.
24.64
-
-
M&L for applying two coats of PU based liquid single component elastomeric water proofing menbrane on sunken slab complete all as specified and as directed.
24.64
-
-
M&L for PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and as directed.
4.14
-
-
Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the MoD land, all as specified and as directed.
950
-
-
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
2
-
-
M&L for Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
18
-
-
M&L for rendering 20mm thick with cement mortar 1:4 on fair faces of brick work in two layers (10mm and 10mm) sperately mixed with water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and fair complete all as specified and directed. Note:- WPC shall be measured & paid separately
200
-
-
M&L for Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed.
250
-
-
M&L for Rendering 5 mm thick plastering in cement mortar 1:3 on ceiling, soffits of chajja, column & beams etc for finished even and fair without any extra cost complete all as specified and as directed.
50
-
-
Supply only integral Water proofing compund, complete all as specified and directed.
36
-
-
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top, including of old unserviceable roof treatmnt including PCC padding complete all as specified and directed:-
(i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete and providing PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course
(ii) Rendering 10mm thick in CM (1:4) mixed with and including water proofing compound as per manufacture instruction on existing roof surface true to level after applying cement slurry @ 3Kg/Sqm over RCC slab when concrete is green
(iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.
(iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.50 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 160gms per Sqm. Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.
(v) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.
(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction
189.2
-
-
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed.
30
-
-
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed.
26
-
-
S&F in repair 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
8
-
-
S&F in repair 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
8
-
-
S&F in repair 110mm bore PVC (SWR) junction single,(Single T) equal or unequal of any radius, with access door complete all as specified and as directed.
4
-
-
S&F in repair 110mm bore PVC (SWR) Cowl complete all as specified and as directed.
4
-
-
M&L 75mm outer dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)complete all as specified and as directed.
16
-
-
S&F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed,complete all as specified and directed.
8
-
-
Taking up or down 15mm bore GI pipe and connection complete all as specified and as directed.
64
-
-
Taking up or down 20mm bore GI pipe and connection complete all as specified and as directed.
32
-
-
Taking up or down 25mm bore GI pipe and connection complete all as specified and as directed.
20
-
-
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
69
-
-
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
37
-
-
Supplying and laying of 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
20
-
-
S&F in repairs 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type), screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed.
32
-
-
S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed
8
-
-
S&F in repair 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
40
-
-
S&F in repair, 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
8
-
-
M&L preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
64
-
-
M&L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed.
200
-
-
M&L for complete removal of existing finishes,preparation of old wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed.
345.58
-
-
M&L for preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed.
250
-
-
M&L for complete removal of existing finishes preparation of old wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over new surface over 1 mm thick wall care putty,complete all as specified and directed.
885.42
-
-
M&L preperation of old surfaces of ceilings and applying one coat of white wash,complete all as specified and as directed
121
-
-
M&L preperation of old surfaces of walls and applying one coat of white wash,complete all as specified and as directed
300
-
-
M&L preperation of new plastered surfaces of ceilings and applying three coat of white wash,complete all as specified and as directed
50
-
-
S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) including dismantling of existing unserviceable tank, complete in all as specified and as directed.
8
-
-
Supplying and laying of 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, including taking out old unserviceable 15mm bore GI pipe complete all as specified and as directed.
5
-
-
S&F 750 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms),complete in all as specified and as directed.
6
-
-
S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms),complete in all as specified and as directed.
10
-
-
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Note:- Concealed conduit in RCC slab/beam shall not be not be taken.
316
-
-
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
10
-
-
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed.
212
-
-
Taking up the existing unservicable UG cable of any type/ description as existing at site complete all as directed
Note : Earthwork will be measured and paid seperately.
136
-
-
M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.
Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.
170
-
-
All as per item No 88 here-in-above but One socket out let 5/6 amps point on the same board
40
-
-
All as per item No 88 here-in-above but One socket out let 5/6 amps point on the independent board
56
-
-
All as per item No 88 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps.
2
-
-
M&L concealed point wiring for One one socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.
Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.
48
-
-
S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed.
210
-
-
S&F Switch piano, flush type single pole, two way 5/6 Amp complete all as specified and as directed.
4
-
-
S&F Switch Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed.
40
-
-
S&F Switch socket combination 2 in 1, 3 pin, 5/6 Amp flush type universal complete all as specified and as directed.
56
-
-
S&F Switch socket combination 2 in 1, 3 pin, 15/16 Amp flush type universal complete all as specified and as directed.
48
-
-
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed
94
-
-
S&F step type electronic fan regulator flush type (05 steps) complete all as specified and as directed.
24
-
-
S&F Bell push, flush type, 5/6 amps, flush type complete all as specified and as directed.
8
-
-
S&F Call Bell, AC, 230 volts, single pole complete all as specified and as directed.
8
-
-
S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/angle fittings complete all as specified and directed.
40
-
-
S&F LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified and directed.
64
-
-
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Triple pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed
2
-
-
S&F MCB, FP, C Series 415 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed.
2
-
-
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed
8
-
-
S&F MCB, SPN, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
8
-
-
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
56
-
-
S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed.
44
-
-
S&F energy saving & environment friendly long life 20 Watt,(or nearest next higher wattage) CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed.
10
-
-
S&F LED luminarie surface/wall mounted chamagne gold finish fixture with plastic body, suitable for 9 Watt LED Lamp,(or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, including LED bulb 9 watt 5 STAR LAMP with B 22 base capacity complete all as specified and as directed.
24
-
-
S&F Bulk head LED fitting with injection molded Polycarbonate housing suitable for 10 Watt (or nearest next higher wattage) with IP 66 protection & impact resistance not less than IK-10 complete with integrated type, with high efficiency electronic driver, & high brightness LEDs, luminaire efficacy 100 lumens/Watt, power factor ≥ 0.95, operating range 140 to 270 V, 50 and connecting complete all as specified and as directed.
8
-
-
Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation, laying of UG cable, pipe etc in soft/loose soil & getting out, complete all as directed.
18.2
-
-
Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed.
10.07
-
-
Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all as directed.
8.15
-
-
M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.
7.29
-
-
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
720
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
136
-
-
M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed.
24
-
-
Taking down Ceiling/Exhaust fan of any sweep, necessary cleaning and fixing/Hanging only ceiling/exhaust fan in existing postion after repair work and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
48
-
-
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
212
-
-
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion including dismantling/taking out old unserviceable earthing complete all as specified and as directed.
4
-
-
S&F Cable end termination kit for LT 1.1 KV Cable for Cable 25 to 50 Sqmm 3.5 Core cable complete all as specified and directed .
4
-
-
Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
12
-
-