Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684084_1Tender No
540/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only shunt trip (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating upto 1250 Amps as all per existing of Make complete all as specified and directed.
4
-
-
... More
Supply only under voltage release 240V AC suitable for air circuit breakers of rating upto 1250 Amps as all per existing of Make complete all as specified and directed.
3
-
-
... More
Supply only closing coil suitable for air circuit breakers of rating upto 1250 Amps complete all as specified and directed.
4
-
-
... More
Supply only charging motor 240 V AC suitable for air circuit breakers of rating upto 1250 Amps complete all as specified and directed.
7
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 630 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
2
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 400 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction by Engr-in-Charge complete all as specified and directed at site.
1
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 315/320 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
2
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 250 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
1
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 200 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
3
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 100 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
3
-
-
... More
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 63 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.
4
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 630 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 400 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
3
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 320 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 250 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 200 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 160 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 125 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 100 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 63 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 32 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 63 Amps with breaking capacity 16 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 63 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
7
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 100 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
4
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 100 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 125 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
8
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 125 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 160 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
3
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 160 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
4
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 200 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 200 Amps with breaking capacity 35/36 KA,50 Hz cfixed with panels including any type of addition/alteration complete all as specified and directed at site.
5
-
-
... More
S&F in repair MCCB 3 pole, 415 volt 250 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 250 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 320 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
2
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 350 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 400 Amps with breaking capacity 35 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
5
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 630 Amps with breaking capacity 36/37 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
1
-
-
... More
S&F in repair MCCB 4 pole, 415 volt 630 Amps with breaking capacity 50 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
3
-
-
... More
Servicing and repair/maintenance of APFC panel board of 200 KVR & checking connections between load devices and sensing devices else where located in separate panel to check sequence of supply and set in proper condition including removal of defective device such as CT sensing cable and power cable, repair replacement of fuses, fuse link, control fuses,push button, LED indicators, auto manual selector switch, current transformers and checking/replacing of defective cable lugs,patch work welding, replacement of defective door hinges and testing of capacitor pane obtaining in board power factor to 0.95 to 0.99 of following capacity or panel for the following :-
Note : Replacement of major items will be measured and paid separately.
1
-
-
... More
All as per ser item No 42 here-in- before but 150 KVR APFC panel board.
2
-
-
... More
All as per ser item No 42 here-in- before but 80 KVR APFC panel board.
2
-
-
... More
All as per ser item No 42 here-in- before but 70 KVR APFC panel board.
2
-
-
... More
All as per ser item No 42 here-in- before but 50 KVR APFC panel board.
1
-
-
... More
All as per ser item No 42 here-in- before but 30 KVR APFC panel board.
2
-
-
... More
S&F in repair power factor improvement static condenser of size 1 KVR (Capacitor) of required capacity all as specified and directed at site.
2
-
-
... More
All as per ser item No 48 here-in- before but 2 KVR capacitor.
2
-
-
... More
All as per ser item No 48 here-in- before but 4 KVR capacitor.
2
-
-
... More
All as per ser item No 48 here-in- before but 5 KVR capacitor.
7
-
-
... More
All as per ser item No 48 here-in- before but 7.5 KVR capacitor.
3
-
-
... More
All as per ser item No 48 here-in- before but 8 KVR capacitor.
3
-
-
... More
All as per ser item No 48 here-in- before but 10 KVR capacitor.
8
-
-
... More
All as per ser item No 48 here-in- before but 12.5 KVR capacitor.
3
-
-
... More
All as per ser item No 48 here-in- before but 15 KVR capacitor.
7
-
-
... More
All as per ser item No 48 here-in- before but 20 KVR capacitor.
4
-
-
... More
All as per ser item No 48 here-in- before but 25 KVR capacitor.
2
-
-
... More
S&F in repair power contactors MCX 34 4 pole complete all as specified and directed at site.
1
-
-
... More
S & F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
48
-
-
... More
S&Fix in repair contactor MNX 9 complete all as specified and directed at site.
5
-
-
... More
S&F in repair 3 pole MO C5 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
15
-
-
... More
S&F in repair 3 pole MO C8.5 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
6
-
-
... More
S&F in repair 3 Pole MO C10 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
7
-
-
... More
S&F in repair 3 Pole MO C12.5 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
7
-
-
... More
S&F in repair 3 Pole MO C15 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
10
-
-
... More
S&F in repair 3 Pole MO C20 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
10
-
-
... More
S&F in repair 3 Pole MO C25 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
4
-
-
... More
Supply and fixing in repair of MCB TP 415 volts 16 amps, 'C' curve, 10 KA complete all as specified and directed .
12
-
-
... More
Supply and fixing in repair of MCB TP 415 volts 20 amps, 'C' curve, 10 KA complete all as specified and directed .
19
-
-
... More
Supply and fixing in repair of MCB TP 415 volts 25 amps, 'C' curve, 10 KA complete all as specified and directed .
7
-
-
... More
Supply and fixing in repair of MCB TP 415 volts 32 amps, 'C' curve, 10 KA complete all as specified and directed .
16
-
-
... More
Supply and fixing in repair of MCB TP 415 volts 63 amps, 'C' curve, 10 KA complete all as specified and directed .
12
-
-
... More
Supply and fixing in repair of MCB TPN 415 volts 40 amps, 'C' curve, 10 KA complete all as specified and directed .
8
-
-
... More
Supply and fixing in repair of MCB TPN 415 volts 63 amps, 'C' curve, 10 KA complete all as specified and directed .
7
-
-
... More
Supply and fixing, in repair detuned reactor, copper wound 440 V, 50 HZ of capacity 1 KVR complete all as specified and directed.
2
-
-
... More
All as per ser item No 76 here-in- before but 2 KVR
2
-
-
... More
All as per ser item No 76 here-in- before but 3 KVR
1
-
-
... More
All as per ser item No 76 here-in- before but 4 KVR
2
-
-
... More
All as per ser item No 76 here-in- before but 5 KVR
14
-
-
... More
All as per ser item No 76 here-in- before but 8 KVR
3
-
-
... More
All as per ser item No 76 here-in- before but 10 KVR
10
-
-
... More
All as per ser item No 76 here-in- before but 12.5 KVR
3
-
-
... More
All as per ser item No 76 here-in- before but 15 KVR
10
-
-
... More
All as per ser item No 76 here-in- before but 20 KVR
9
-
-
... More
All as per ser item No 76 here-in- before but 25 KVR
4
-
-
... More
Supply, Installing & testing and commissioning factory made and tested indoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having suitable bus bar chamber with suitable insulated Aluminium bus bar installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.0 mm thick stainless steel sheet andsuitable size of angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size . The scope of work includes the following :- INCOMMING :-
(a) Aluminium Busbar suitable for under mentioned incommer/outgoing MCCBs /Change over switch (b) MCCB 4 Pole, 415 Volt, 400 Amps, breaking capacity 50 kA, (Ics=100 % of Icu) with Adjustable Thermal & Adjustable Magnetic Type . - 01 Nos
(c) Onload Change over switch, panel execution type, 400 Amps, 440 Volt, 3 phase, 4 pole, 50 cycle and allied accessories. -01 Nos
(d) Voltmeter /ammeter square type to measure three/single Voltage phase, load current, frequency,selector switch including necessary CT/PT of suitable ratio . : Each Job
(e) LED Indicator lamp (R,Y,B) - Set of Three.
OUTGOING :-
(a) MCCB 4 Pole, 415 Volt, 400 Amps, breaking capacity 36/37 kA, - 01 No
1
-
-
... More
Supply, Installing & testing and commissioning factory made and tested indoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having suitable bus bar chamber with suitable insulated Aluminium bus bar installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.0 mm thick stainless steel sheet andsuitable size of angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size . The scope of work includes the following :- INCOMMING :-
(a) Aluminium Busbar suitable for under mentioned incommer/outgoing MCCBs (b) MCCB 4 Pole, 415 Volt, 400 Amps, breaking capacity 36/37 kA, . - 01 No
(c) Voltmeter /ammeter square type to measure three/single Voltage phase, load current, frequency,selector switch including necessary CT/PT of suitable ratio . : Each Job
(d) LED Indicator lamp (R,Y,B) - Set of Three.
OUTGOING :-
(a) MCCB 4 Pole, 415 Volt, 160 Amps, breaking capacity 25/27 kA, - 01 No
(b) MCCB 4 Pole, 415 Volt, 100 Amps, breaking capacity 25/27 kA, - 02 No
1
-
-
... More
Supply, Installing & testing and commissioning factory made and tested outdoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having suitable bus bar chamber with suitable insulated Aluminium bus bar installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.0 mm thick stainless steel sheet and suitable thickness of angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size . The scope of work includes the following :- INCOMMING :-
(a) Aluminium Busbar 200 Amp rating suitable for incommer and outgoing MCCB
(b) MCCB 4 Pole, 415 Volt, 125 Amps, breaking capacity 25 kA, with Adjustable Thermal & Adjustable Magnetic Type . - 01 Nos
(b) Onload Change over switch, panel execution type, 125 Amps, 440 Volt, 3 phase, 4 pole, 50 cycle and allied accessories. -01 Nos
(c) Voltmeter /ammeter square type to measure three/single Voltage phase, load current, frequency,selector switch including necessary CT/PT of suitable ratio . : Each Job
(d) LED Indicator lamp (R,Y,B) - Set of Three.
OUTGOING :-
(a) MCCB 4 Pole, 415 Volt, 63 Amps, breaking capacity 25/27 kA, - 01 No
(b) MCCB 4 Pole, 415 Volt, 40 Amps, breaking capacity 25/27 kA , - 01 No
(c ) MCCB 4 Pole ,415 Volt,32 Amps, breaking Capacity 25/27 KA - 02 Nos
1
-
-
... More
Supply, Installing & testing and commissioning factory made and tested outdoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having suitable bus bar chamber with suitable insulated Aluminium bus bar installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.0 mm thick stainless steel sheet and suitable thickness of angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size . The scope of work includes the following :- INCOMMING :-
(a) Aluminium Busbar 200 Amp rating suitable for incommer and outgoing MCCB
(b) MCCB 4 Pole, 415 Volt, 125 Amps, breaking capacity 25 kA, with Adjustable Thermal & Adjustable Magnetic Type . - 01 Nos
(b) Voltmeter /ammeter square type to measure three/single Voltage phase, load current, frequency,selector switch including necessary CT/PT of suitable ratio . : Each Job
(c) LED Indicator lamp (R,Y,B) - Set of Three.
OUTGOING :-
(a) MCCB 4 Pole, 415 Volt, 63 Amps, breaking capacity 25/27 kA, - 01 No
(b) MCCB 4 Pole, 415 Volt, 40 Amps, breaking capacity 25/27 kA , - 01 No
(c ) MCCB 4 Pole ,415 Volt,32 Amps, breaking Capacity 25/27 KA - 02 Nos
1
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level ) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to main GI strip 32 x 6 mm as earth strip by means of bolts ,nuts and washers of galvanised iron or steel as shown in electrical plate No. 3, including exc , and earth work in any type of soil disposal of soil providing alternate layers of charcol and common salt construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick 1:2:4 type B-1 cover reinforced with 8 mm dia MS bars both ways with lift hook made out of 8 mm dia bar,watering arrangement. Note : Main earth strip beyond 7.5 meter shall be measured and paid saperatly. Taking down old unserviceable dilapidated chemical earthing are included in quoted rate. Note : (1) 7.5 RM GI strip deemed to be included in quoted rates beyond 7.5 RM GI strip shall be measured and paid separately.
(2) Earth resistance of earth pit should be less than 5 Ohms.On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
(3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI Plate.
10
-
-
... More
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
10
-
-
... More
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
10
-
-
... More
M&L for painting on old painted surface of LT panels by brushing/cleaning stains & grease spots with thinner and sand paper and painting the cleaned surface with synthetic enamel paint (Light gray) Shade No 631 or as approved by the Engr-in-charge to achieve good finish by applying two coats of paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators relays and switches to prevent from fall of paint drops on the panels including writing, number, letter etc with white paint on newly painted surfaces details as given by Engr-in-charge
20
-
-
... More
S&F in repairs MS sheet covers/doors of any thickness and shape for LT panels including required fabrication,welding,cutting etc and fixing of hinges, including locking arrangement as per site requirement all as specified and directed at site.
200
-
-
... More
Disconnecting electrically switch boards/ electric panels/ distribution boards of any size by taking proper electric shut down, opening cables from MCCBs/DBs/main switches/panels, cutting of unserviceable/burnt out//overheated cable ends/ thimbles etc including excavation /earthwork etc and M&L for fixing of new aluminium lugs of any size up to 300 sqmm as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing system.Note :- (i) any addition/alteration required included in the quoted rate in the items.
(ii) All consumable items such as lugs/cable piece etc required at site included in the quoted rate in the items.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%