Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 76,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665108_3Bid Award Id
ViewTender No
8806/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed.
6.8
-
-
... More
Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any posotion complete all as specified & directed.
95
-
-
... More
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed.
198
-
-
... More
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed.
12
-
-
... More
Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
8.45
-
-
... More
Demolition of reinforced cement contrete of any description in any position not otherwise specifically provided for complete all as specified & directed.
1.5
-
-
... More
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge.
20
-
-
... More
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed by the Engineer-in-Charge.
5
-
-
... More
M&L for providing reinforced cement concrete Type B-1, (1:2:4) (using 20mm nominal size graded crushed stone aggregate) as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete all as specified and directed.
8.54
-
-
... More
M&L Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for rough finished flat surfaces of concrete complete all as specified & as dirceted.
106.8
-
-
... More
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified & as dirceted.
803.2
-
-
... More
M & L for mild steel TMT bars 6 mm to 8 mm dia, in stirrups cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
302
-
-
... More
M&L for brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed.
160
-
-
... More
M & L for brick work with subclass “B” Old size bricks, straight or curved on plan,exceeding 6 m mean radius, built in CM 1:6 complete all as specified and directed.
25.8
-
-
... More
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed.
160
-
-
... More
M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement complete all as specified & directed.
350
-
-
... More
M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 mm thick and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
130
-
-
... More
M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed.
350
-
-
... More
M&L for factory made Pressed steel frames of size (125 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
25
-
-
... More
M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed.
0.2
-
-
... More
Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed.
4287
-
-
... More
Supply & Fixing mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed.
500
-
-
... More
S&F for rolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed.
46
-
-
... More
S & F Mild steel bolts with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter exc 12 n.exc 20 complete all as specified and directed
3
-
-
... More
M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed
460
-
-
... More
M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
50
-
-
... More
Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed by Engineer – in - Charge.
170
-
-
... More
M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions
170
-
-
... More
S&F 30 mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats complete all as specified & directed.
12
-
-
... More
S&F 35 mm thick, hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified & directed.
12
-
-
... More
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified & directed.
10
-
-
... More
S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete all as specified and as directed.
20
-
-
... More
S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed.
20
-
-
... More
S&F 300mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed.
5
-
-
... More
M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
50
-
-
... More
S & F for aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified
24
-
-
... More
S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified & as directed.
322
-
-
... More
M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
236.5
-
-
... More
M&L preparing old wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
15
-
-
... More
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed.
70
-
-
... More
M&L for 40mm thick PCC , type B1 (1:2:4) using 20mm aggregates in floors, finished even and smooth, using extra cement complete all as specified and directed.
104
-
-
... More
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0 kg of cement per sq. metre.
170
-
-
... More
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed.
250
-
-
... More
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed.
7
-
-
... More
S&F in repair harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
20
-
-
... More
Surface excavation 30cm deep and getting out in soft/loose soil complete all as specified and directed.
118
-
-
... More
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, getting out in soft / loose soil complete all as specified and directed
12
-
-
... More
Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregates) in foundations, filling, mass concrete etc complete all as specified and directed.
2.35
-
-
... More
Material & Labour for plain cement concrete (1:2:4), type B-2, (using 40mm graded stone aggregate) in foundations, filling, mass concrete etc complete all as specified and directed.
2.5
-
-
... More
Material & Labour for Hardcore of gauge not exceeding 63 mm, og broken stone or boulders deposited,spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed
8
-
-
... More
Material & Labour for Plain cement concrete ( 1:3:6 ), type C-2 (using 40 mm graded stone aggregate), as in sub base of floor complete all as specified and as directed.
12
-
-
... More
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement complete as specified & directed.
25
-
-
... More
M&L for Glass dividing strips, 3 mm thick 38mm wide and inserted in position, conform to design complete all as specified and directed
100
-
-
... More
M&L Prepration of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete.
30
-
-
... More
M & L for Chequred cement corcrete tile of size 20cm x 20xm x 25 mm thick with grey cement and pigments, set, jointed and pointed in grey cement slurry and pigments in floor laid over and incl 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified & as dirceted.
8
-
-
... More
M&L for Providing, cement concrete 1:2:4 type B1 using 20mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
0.1
-
-
... More
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed.
85
-
-
... More
M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) two runs of single core FRLSH PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including PVC casing and capping of suitable size but not less than 20mm, with all fittings, fixed on wall/ceiling /floor including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH(ISI marked) but green in colour as continuous earthing wire, complete all as specified & directed for :-
Note :- (i) Modular Plates & Covers and Modular Metal Boxes/PVC Boxes will measured and paid separately under relavant items.
(ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(a) One light /Fan /Ex Fan point controlled by one, one way switch (b) One socket outlet 3 or 5 Pin, 6 Amp on independent board
88
-
-
... More
All as per Srl Item No 61.00 above but for one socket outlet 3 or 5 Pin, 6 Amp on same board complete all as specified & as directed.
4
-
-
... More
All as per Ser item No 61.00 above but with using 2.5 sqmm copper cable in and including PVC casing and capping for socket outlet 3 or 6 pin 15 Amps complete all as specified and as directed
5
-
-
... More
S&F modular switch 10 Amp one way 1 module 230 V AC complete all as specified and directed.
89
-
-
... More
S&F modular switch 20 Amp one way 1 module 230 V AC complete all as specified and directed.
5
-
-
... More
S&F modular socket outlet 10 Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed.
20
-
-
... More
S&F modular socket outlet 20 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed.
5
-
-
... More
S&F modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed.
28
-
-
... More
S&F switch paino flush type 6 Amps single pole one way 230 volts AC circuit complete all as specified and directed.
3
-
-
... More
S&F 3 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
18
-
-
... More
S&F 4 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
9
-
-
... More
S&F 6 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and as directed.
72
-
-
... More
S&F Inverter type LED tube light batten 4 ft. 1 x 18/20 watt, 230 volts inbuilt Lithium ion battery with charging time 8 to 10 Hrs and back up time upto 4 Hrs complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin core flexible copper conductor cable with suitable size, complete all as specified and directed.
24
-
-
... More
Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained taking down complete all as directed.
8
-
-
... More
S&F LED tube light fitting 4 ft. 1 x 18/20 watt with 230 volts AC, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
2
-
-
... More
S&F LED Tube lights fitting 1 x 9/10 Watt, 2 feet , 220V AC decorative box type with driver, including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed.
2
-
-
... More
S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection complete all as specified and directed.
5
-
-
... More
Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard by the contactor.
26
-
-
... More
Over hauling of ceiling fan of any sweep/ make i.e. opening of fan and cleaning ball bearing, filling grease/ oil and changing of u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling and painting complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust complete all as directed.
14
-
-
... More
Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed.
14
-
-
... More
S&F ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods and connected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor and connection complete all as specified and directed.
14
-
-
... More
M&L for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing and capping as per direction complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutter and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of PVC casing and capping shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the PVC casing and capping.
20
-
-
... More
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 12 way (2 + 10 way) single pole and neutral link, incl taking down old u/s any type, complete all as specified and as directed.
1
-
-
... More
S&F single pole and neutral DB wall mounting type, 240 Volts,8 Way with 200 Amps rated bus bar, double door suitable for fixing MCB's including connecting etc and taking down U/S DB ,main switch complete.
1
-
-
... More
Supply & fix Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way single pole and neutral link complete all as directed by Engineer-in-Charge.
1
-
-
... More
S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed.
2
-
-
... More
S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs, complete all as specified and directed.
2
-
-
... More
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'C' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
20
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete including taking down old u/S service wire.
75
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete
45
-
-
... More
Excavation in trenches not exc. 1.5 meter deep and not exc 1.5 metre wide for taking up/laying of under ground cable/pole and stay foundation and getting out in soft/loose soil complete as specfied and as directed.
33
-
-
... More
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specfied and as directed.
16.5
-
-
... More
Removing surplus soil to a distance not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and as directed.
32.2
-
-
... More
M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class"B" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge.
0.79
-
-
... More
M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complet all as specified and directed by Engr-in-Charge. (Punned thickness shall be considered for payment).
7.8
-
-
... More
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 40 mm complete all as specified and as directed .
15
-
-
... More
Boring of holes under road, pavement, hard standing by for passing the cable throgh GI pipe complete all as specified and directed by Engr -in-Charge.
6
-
-
... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed.
3
-
-
... More
S&F Wall Mounted fans dacorative type 400 mm sweep, 230V AC Supply, 50 Hz, high performance, smooth oscillation, copper bound motor made of sturdy Engineering plastic and metal ribs guard complete as per complete all as specified and as directed.
3
-
-
... More
Supply, installation, testing & commissioning of metal top Deep Freezer, storage capacity 400 or 405 Ltrs, Five Star convertible type with temperature control facility, electric driven (single phase), 230 volts, AC, 50 Hz complete all as specified and directed
2
-
-
... More
Supply, installation, testing & commissioning of Refrigerator double door, storage capacity 300 or 310Ltrs, frost free, Five Star electric driven (single phase), 230 volts, AC, 50 Hz complete all as specified and directed
2
-
-
... More
S&F voltage stabilizer suitable for Refrigerator/deep freezer 300 to 600 Ltr capacity automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130-290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 Amps complete all as specified and directed
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements