Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Dec 2024
Closing Soon15 Jan 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR MAINTENANCE OF EARTHING BLDG LIGHT AND OTHER CONNECTED WORKS UNDER GE NARANGI
REPAIR MAINTENANCE OF EARTHING BLDG LIGHT AND OTHER CONNECTED WORKS UNDER GE NARANGI
REPAIR MAINTENANCE OF EARTHING BLDG LIGHT AND OTHER CONNECTED WORKS UNDER GE NARANGI
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed. .

50

-

-

... More
Supply and fixing in repair batten type LED light fitting 1x 20W, 220V,AC decorative type with internal SPD upto 4kV and overload voltage protection upto 440V including flexible copper conductor cable of suitable size from ceiling rose complete all as specified .

20

-

-

... More
Taking down defective street/ flood light fittings from height upto 11mtr of wattage upto 120 ,from pole for repairs and refixing the same,after replacing defective accessories like LED driver, SPD, PVC insluted sheathed copper conductor etc.complete all as directed. (Note :For item no 6 new spare parts/components of street light fittings shall be measured and paid separately under respective items as supply only however,screws, insulation sleeves, nuts, bolts, washers and PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmm X 3 core from light fitting to Street light feeder (max 1.5 mtr ) deemed to be included in quoted rate.)

220

-

-

... More
Supply only constant current LED driver suitable for LED luminaries of wattage of 45 Watt complete all as specified and directed

100

-

-

... More
All as per item No 07 here in above but of 60Watt.

80

-

-

... More
All as per item No 07 here in above but of 90 Watt.

40

-

-

... More
Supply only surge protection device of capacity 10kV complete all as specified and directed.

50

-

-

... More
Taking down defective flood light / high mast fitting of any size /any type/any capacity from height of pole/ walls/ height mast of any location of poles any height from ground level for reapir work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge. Note : (a) Spares Driver ,SPD etc. shall be measured and paid separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder& other T&P required etc shall be arranged by the contractor (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts,cirle clips, clamps and connection wire upto 1.5 mtr etc if required at site.

10

-

-

... More
Supply only constant current LED driver suitable for LED luminaries of wattage of 50 Watt complete all as specified and directed

5

-

-

... More
All as per item No 12 here in above but of 70/80Watt.

5

-

-

... More
All as per item No 12 here in above but of 100/120Watt.

5

-

-

... More
Supply and fixing LED street light of capacity 45 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥120 lumens/watt,CRI70 ,PF 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kV including taking out old unserviceable luminare complete all as specified and directed Note: For Item No. 15 to Item No. 18. (i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate.

50

-

-

... More
Supply and fixing LED street light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥120 lumens/watt,CRI70 ,PF 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kV including taking out old unserviceable luminare complete all as specified and directed.

30

-

-

... More
Supply and fixing street light fitting of 90 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI70 ,PF 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage complete all as specified and directed.

15

-

-

... More
Supply and fixing LED flood light of capacity 50 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have LED efficacy≥100 lumens/watt,CRI70 PF 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt 5kV surge protection device including taking out old unserviceable luminare complete all as specified and directed.

2

-

-

... More
Supply and fixing LED flood light of capacity 80 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have LED efficacy≥100 lumens/watt,CRI70 PF 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt 5kV surge protection device including taking out old unserviceable luminare complete all as specified and directed

2

-

-

... More
Supply and fixing LED flood light of capacity 100 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have LED efficacy ≥100 lumens/watt,CRI70 PF 0.95,CCTCCT≥5500,IP66,impact resistance IK 07 ,inbuilt 5kV surge protection device including taking out old unserviceable luminare complete all as specified and directed.

1

-

-

... More
Supply & fixing and testing of gate light / post-top light fitting 35W / 40W LED with die cast aluminium body with drive, 230 volts or nearest size and with IP-65 protection with high power LED as source all necessary fixing arrangments and fittings etc including taking out old one of any type complete all as specefied and directed.

2

-

-

... More
Supply and fixing in repairs MCBs, DP 32 Amps, 240V 10 kA, 'C' curve complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs MCBs, FP 32 Amps, 240V 10 kA, 'C' curve complete all as specified and directed.

2

-

-

... More
Supply and fixing in repairs MCBs, FP 63 Amps, 240V 10 kA, 'C' curve complete all as specified and directed.

2

-

-

... More
Materials and Labour for connection of junction box to street light luminaire using wiring with two runs (P-N) of single core 1.5 Sqmm (nominal area) (FR-LSH) PVC insulated and unsheathed multi-stranded copper conductor cable 1100 volts grade and one run of (FR-LSH) PVC insulated and unsheathed multi-stranded copper conductor of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit(Heavy grade) and tiding the same by aluminium strip with the pole complete all as specified and directed. (Two single core 1.5 Sqmm cable and one single core 1.5 Sqmm earth conductor cable and one run of PVC conduit shall be measured as one run).

60

-

-

... More
Supply and fixing in repairs street light bracket made of GI pipe 40 mm bore light grade(bend to shape) , 1.5 metre long and fixed with mild steel flat iron clamp(clamp shall be 40 X 5mm ), nuts, bolts and washers on pole complete all as specified and directed.

8

-

-

... More
Supply and fix in repair 3 pole power contactor of AC1 rating 50 Amps , with built in surge suppressor , RoHS compliant including necessary electrical connection with suitable size of copper cable complete all as specified and directed.

3

-

-

... More
Supply and fix in repair astronomical time switch single Phase operates on 110-240VAC including all necessary connection complete all as specified and directed.

5

-

-

... More
Supply and fixing in repair CPRI Tested street light panel of suitable dimension outdoor type, powder coated,dust and vermin proof IP-55,prewired , operates on three phase made with 1.6mm thick CRCA sheet with locking arrangement duly painted. having auto/manual selector switch, including MS flat iron clamp (Clamp shall be 40X 5mm ), nuts bolts & washers for fixing arrangement with pole and connecting incoming/outgoing cable with suitable size of lugs and comprising the following. (i) MCB , Four Pole of capacity 32 Amps ,C-curve of breaking capacity 10kA-2 Nos ( one for I/C and another for O/G) (ii) Astronomical timer(Astro mini ) 110-240VAC, 1 Phase . Cat Part No. T2DDT7 of L&T or equivalent in Havells/C &S (iii) 3 Pole contactor of Current rating AC1 50 Amps , with inbuilt surge suppressor and RoHS compliant. L& T Cat Part No: CS94568 or equivalent in Havells/ C&S (iv) LED type red indicator lamp (v) Auto/ Manual selector switch (vi) 63A, 4P, TERMINAL- 2 Nos (vii)2A, SP, 10kA MCB- 01 Nos (For timer protection)

2

-

-

... More
Materials and Labour for earthing complete with copper earth plate electrode 60 cm x 60cm x 3.15 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to copper strip 20 X 3 mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, 20mm dia GI pipe medium grade for watering pipe and 25mm bore GI pipe, light grade for protection of copper strip, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, desposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete including taking down old unserviceable earthing & earth pit complete all as specified and as directed . NOTES 1). The unit rate include copper strip from top of earth plate upto 7.5 meter above ground level.

8

-

-

... More
Materials and Labour for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 25 X 4mm dia GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable earthing & earth pit complete all as specified and as directed.

8

-

-

... More
Supply and fix in repair street light junction box of any size made of high quality polycarbonate with IP-66 protection (Dust and vermin proof according to IEC-60529) totally insulated made of halogen and silica free recyclable material having high quality gasket made out of polyurethane with MCB, DP, 10KA, 6 Amps to be fixed on Din rail , with locking arrangement with cable gland suitable upto 50 sqmm cable and necessary fixing arrangements such as clamps, nuts, bolts etc complete all as specified and as directed.

10

-

-

... More
Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4.0 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc including taking down old , complete all as specified and as directed.

50

-

-

... More
Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4.0 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc including taking down old , complete all as specified and as directed.

50

-

-

... More
Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4.0 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc including taking down old , complete all as specified and as directed.

50

-

-

... More
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.

18.22

-

-

... More
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)

7.29

-

-

... More
Material and labour for bricks sub class ‘B’ brick old size for cable protection laid in flat in trenches over the cable perpendicular to the direction of cable complete all as specified

0.72

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed.

9.84

-

-

... More
Removing of excavated soil not exc 50cm & depositing where as directed at a level n.exc 1.5m above starting point

8.38

-

-

... More
Material and Labour for GI pipe light grade 40mm bore dia with all fittings to be laid in trenches or in floors,including taking down rusted one complete all as speciffied and as directed.

10

-

-

... More
Material and Labour for manual boring under roads/hard standing by reqd T&P without disturbing the top surface of the road for throughing the cable in GI Pipe of n exc 80 mm dia all as specified and directed.

10

-

-

... More
Materials and Labour for plain cement concrete 1:4:8, type D2, (using 40 mm grade stone aggregate) as in foundation, filling and mass concrete etc including demolition of old concrete complete all as specified and as directed.

15

-

-

... More
Materials and Labour for PCC 1: 3 : 6 type C-1 (using 20 mm graded crushed stone aggregate) as in mass concrete including necessary form work for coping including demolition of old concrete Steel Poles complete all as specified and directed.

12

-

-

... More
Materials and Labour for supply, spreading and levelling for loose filling, of gauge 40 mm size graded crushed stone aggregate in transformer yard all as specified and directed.

60

-

-

... More
Materials and Labour for supply, spreading and levelling for loose filling, of gauge 20 mm size graded crushed stone aggregate in transformer yard all as specified and directed.

60

-

-

... More
Materials and Labour cutting grasses, shrubs/herbs surrounding LT poles, feeder pillar box installations by mechanical or manual T&P, and leveling / removing the sand of sub stn as required and removing the debris at a distance not exceeding 50m and depositing where directed complete all as specified and as directed.

200

-

-

... More
Materials and Labour for brick work with sub class ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.

20

-

-

... More
Demolition of brick work built in cement mortar including all quoins, arches, pillar including coping etc. complete all as specified and as directed.

10

-

-

... More
Materials and Labour for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including three coat of white wash complete all as specified and as directed

20

-

-

... More
Supply and fixing street light fitting of 120 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI70 ,PF 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old light complete all as specified and as directed

11

-

-

... More
Supply and fixing in repair providing and fixing 610mm dia Razor Concertina coil fencing with and including required clips, pins, etc. as per manufacturer's instruction and as per specification fixed on the Y angle. Each concertina coil shall be fixed to MS angle with existing rows of barbed wire on each of Y angle. There shalll be 80 ( eighty) circles in each 9.00 mtr length. Number of clips in each 9.00 mte shall be 200 Nos., central core wire 12 SWG hot galvanised high tensileed wire : UTS- 145-160 Kg/Sqmm. Razor strip 0.50mm thick hot dipped galvanised and of length 19mm, clips 1.5mm thick made of SSAISI 410 complete.

18

-

-

... More
Materials and Labour for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with two coats of aluminium paint over a coat of red oxide primer including taking down the old unserviceable cross arms, clamps etc complete all as specified and as directed.

0.5

-

-

... More
Materials and Labour for cutting the faulty/damaged/burnt end portion of the UG cables of crossectional areaof any size and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing its own position, including Insulation tape, nut ,bolts etc as required in distribution boards/LT Panel boards/Change over switches complete all as specified and directed. Note :Necessary excavation, earth work should be measured and paid separately if reqd.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.