Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Sep 2023
Closing Date16 Oct 2023
Tender Amount₹ 26,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repair/overhauling /Calibration of fuel injection pump and nozzle with holder assembly of diesel engine including providing new parts such as delivery valves. Elements, tapet gear, plungar , noozzie copper washes, leak off pipes, banzo bolts, service kit, governer repair etc in replacement of existing UNSV Parts including re-assembiling, setting , fixing and testing at site suitable of 10 KVA to 30 KVA DG set.

5

-

-

... More
All as per serial item No 4 above but for 40 to 75 KVA DG Set

4

-

-

... More
All as per serial item No 4 above but for 100 to 160 KVA DG Set

1

-

-

... More
Repair / Replacement of safety devices complete unit for DG set (water temperature meter, Hour Meter, oil pressure meter, water temperature sensor, Low pressure sensor, vacuum indicator) (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for following DG sets :-

-

-

-

... More
(a) 10KVA to 30 KVA

5

-

-

... More
(b) 40 KVA to 75 KVA

3

-

-

... More
(c)100 KVA to 160 KVA

1

-

-

... More
Supply of following spares parts (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 10 to 30 KVA capacity DG Sets :-

-

-

-

... More
(a) Fuel Filter element

15

-

-

... More
(b) Flexible pipe

8

-

-

... More
(c) Air Filter cartridge

8

-

-

... More
(d) Set of high pressure pipe

8

-

-

... More
(e) Oil Filter cartridge

8

-

-

... More
(f) Flex pipe for lub oil

8

-

-

... More
(g) Thermostat

8

-

-

... More
(h) Cooling water pipe

8

-

-

... More
(j) set of hoses

8

-

-

... More
(k) set of hose clip

8

-

-

... More
(l) Set of flexible fuel pipe

8

-

-

... More
(m)Set of anti vibration rubber coupling bushes with stud bolts and nuts

6

-

-

... More
(n) Head Gasket

1

-

-

... More
(o) Head Gasket Set

1

-

-

... More
(p) Fly wheel side oil seal

1

-

-

... More
(q) Fly wheel ring gear

1

-

-

... More
(r) STR Relay Board

1

-

-

... More
(s) RRA

1

-

-

... More
(t) Controller board

3

-

-

... More
(u) Stop solenoid

1

-

-

... More
(v) Temp Sensor

2

-

-

... More
Supply of following spares parts (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 40 to 75 KVA capacity DG set :-

-

-

-

... More
(a) Fuel Filter element

10

-

-

... More
(b) Flexible pipe

5

-

-

... More
(c) Air Filter cartridge

5

-

-

... More
(d) Set of high pressure pipe

5

-

-

... More
(e) Oil Filter cartridge

5

-

-

... More
(f) Flex pipe for lub oil

6

-

-

... More
(g) Thermostat

6

-

-

... More
(h) Cooling water pipe

6

-

-

... More
(j) set of hoses

5

-

-

... More
(k) set of hose clip

5

-

-

... More
(l) Set of flexible fuel pipe

5

-

-

... More
(m) Set of anti vibration rubber coupling bushes with stud bolts and nuts

5

-

-

... More
(n) Head Gasket

1

-

-

... More
(o) Head Gasket Set

1

-

-

... More
(p) Fly wheel side oil seal

1

-

-

... More
(q) Fly wheel ring gear

1

-

-

... More
(r) STR Relay Board

1

-

-

... More
(s) RRA

1

-

-

... More
(t) Controller board

2

-

-

... More
(u) Stop solenoid

1

-

-

... More
(v) Temp Sensor

2

-

-

... More
Supply of following spares parts (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 100 to 160 KVA capacity DG Sets :-

-

-

-

... More
(a) Fuel Filter element

2

-

-

... More
(b) Flexible pipe

2

-

-

... More
(c) Air Filter cartridge

2

-

-

... More
(d) Set of high pressure pipe

2

-

-

... More
(e) Oil Filter cartridge

2

-

-

... More
(f) Flex pipe for lub oil

2

-

-

... More
(g) Thermostat

2

-

-

... More
(h) Cooling water pipe

2

-

-

... More
(j) set of hoses

2

-

-

... More
(k) set of hose clip

2

-

-

... More
(l) Set of flexible fuel pipe

2

-

-

... More
(m)Set of anti vibration rubber coupling bushes with stud bolts and nuts

2

-

-

... More
M&L for preparation of old painted body surface of 10 to 30 KVA DG set and applying two coat of synthetic enamel paint as per colour code to the body of DG set and alternator and red colour to the belt guard including writing MES/SM Nos complete all as specified and directed by Engineer-in-Charge.

7

-

-

... More
All as per serial item No 11 above but for 40 to 75 KVA capacity DG Set.

4

-

-

... More
All as per serial item No 11 above but for 100 to 160 KVA capacity DG Set.

1

-

-

... More
Supply and fix in repair V belt for any drive suitable for DG set capacity 10 to 160 KVA complete all as specified and as directed.

6

-

-

... More
Repairs/replacement to exhaust manifold (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) by replacement of worn out silencer unit of required size and shape suitable for DG set 10 KVA to 30 KVA complete all as specified and directed.

3

-

-

... More
All as per item 15 here in before but suitable for DG set capacity 40 KVA to 75 KVA complete.

2

-

-

... More
All as per item 15 here in before but suitable for DG set capacity 100 KVA to 160 KVA complete.

1

-

-

... More
Cleaning of fuel tank of any capacity by draining out diesel and cleaning internally with the help of cleaning agent and compressed air , drain out the sludge/foreign matter deposited inside the diesel tank of any capacity of DG set from 10 to 30 KVA capacity

14

-

-

... More
All as per item 18 here in before but suitable for DG set capacity 40 KVA to 75 KVA complete.

11

-

-

... More
All as per item 18 here in before but suitable for DG set capacity 100 KVA to 160 KVA complete.

2

-

-

... More
M&L for reconditioning of lead acid battery (MAKE- Exide/ Luminous/ as existing) of capacity 60/90/100/180 AH 12 volt capacity by replacing the damaged cell , separator and filling diluted electrolite of appropriate concentration and charging complete all as directed.

15

-

-

... More
Taking out old unserviceable battery charger and supply and fix battery charger (MAKE- Exide/ Luminous/ as existing) suitable for charging lead acid battery 6/12volt boost and trickle charging mode, 230 volt single phase complet with charging lead connecting clip complete all as specified and as directed.

4

-

-

... More
M&L for replacement of lubrication oil 20W40, (MAKE- Castrol/ Servo/ Shell) in DG sets of capacity 10 to 160 KVA all as specified and directed.

350

-

-

... More
Replacement and Repair of self starter (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) 12 volts for 10 to 30 KVA DG set by replacing the defective worn out parts such as armature, field coil, bendex pinion, clutch plate, solinoid switch and any other necessary parts including testing complete.

7

-

-

... More
All as per serial item No 24 above but for 40 to 75 KVA capacity DG Set.

5

-

-

... More
All as per serial item No 24 above but for 100 to 160 KVA capacity DG Set.

1

-

-

... More
Taking out radiator assy and repair by cleaning washing flushing and removing blockage of chocked tubes including replacement of existing UNSV water tube soldering nuts bolts washers and making leakproof and testing at site of 10 to 30 KVA DG Set.

3

-

-

... More
All as per serial item No 27 above but for 40 to 75 KVA capacity DG Set.

2

-

-

... More
All as per serial item No 27 above but for 100 to 160 KVA capacity DG Set.

1

-

-

... More
Replacement of battery copper leads 2 meter long of suitable size single core with copper thimble complete.

16

-

-

... More
Replacement of battery terminals brass of any capacity battery complete.

16

-

-

... More
Repair to alternater complete by dismantling and cutting winding, cleaning, polishing, welding work and re-winding with suitable size and gauge of copper enamelled winding wire complete greasing, replacement of carbon brush, varneshing etc and testing after repair of 10 to 30 KVA DG Set including testing after repair complete all as specified and directed.

5

-

-

... More
All as per serial item No 32 above but for 40 to 75 KVA capacity DG Set complete.

4

-

-

... More
All as per serial item No 32 above but for 100 to 160 KVA capacity DG Set complete.

1

-

-

... More
Taking out Dynamo 12 V for complete repair including providing new parts such as armature, brushes, filed coil , bush bearings,cut out, bearing, pully nut, bolts & washer etc in replacement of exisitng UNSV Parts refixing and testing at site of 10 to 30 KVA DG Set.

4

-

-

... More
All as per serial item No 35 above but for 40 to 100 KVA capacity DG Set.

3

-

-

... More
All as per serial item No 35 above but for 100 to 160 KVA capacity DG Set.

1

-

-

... More
Supply only distilled water for lead acid cell 12 Volt complete.

120

-

-

... More
Supply and replacement of Automatic Voltage Regulator suitable for DG sets of Capacity 10 to 75 KVA.

3

-

-

... More
All as per serial item No 39 above but for 100 to 160 KVA capacity DG Set.

2

-

-

... More
AC VOLTAGE STABILIZER/UPS M & L for repair to AC voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating, reassembling, and testing complete all as specified and directed of capacity 0.50 KVA to 2.0 KVA voltage stabilizer, complete all as per specified and as directed by Engineer-in-charge.

20

-

-

... More
All as per item no 41 above but 3.15 KVA voltage stabilizer

20

-

-

... More
All as per item no 41 above but 4 to 5 KVA voltage stabilizer

22

-

-

... More
M&L for minor repair of Voltage Stabilizer of upto 2 KVA Capacity of any MAKE including replacement of Relay, Capacitors, Switches, Voltmeters and Testing, etc., complete all as specified and as directed. (MAKE of spare parts- Havells/ L&T/ Siemens/ as existing)

20

-

-

... More
M&L for minor repair of Voltage Stabilizer of 3 to 5 KVA Capacity of any MAKE including replace-ment of Relay, Capacitors, Switches, Voltmeters and Testing, etc., complete all as specified and as directed. (MAKE of spare parts- Havells/ L&T/ Siemens/ as existing)

20

-

-

... More
M & L for repair to AC servo voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating,copper lugs,and nuts and bolts etc and reassembling and testing complete all as specified and directed of capacity 20 KVA to 500 KVA voltage stabilizer

3

-

-

... More
M&L for topping up of transformer oil of dielectric strength more than 50KV in servo voltage stabilizer all as specified and directed.

425

-

-

... More
Disconnecting AC supply,dismantling, taking down and opening Servo stabilizer having capacity 20 KVA to 75KVA. Servicing, repair/replacement unserviceable parts such as contact bush, mechanical tap moving system, filtration of oil, topup new oil, servo motor, carbon busher assembly with carbon and repair/maint/replacement of PC board, indicator, transformer etc and other minor parts found defective during repairing. Re-assembling the same after repairing and commissioning testing, complete all as per specified and as directed by Engineer-in-charge. NOTE :- Parts replaced of voltage stabilizer shall be measured and paid separetly under respective items. (MAKE of spare parts- Havells/ L&T/ Siemens/ as existing)

6

-

-

... More
(a) Repair/replacement of indicator of different colour.

6

-

-

... More
(b) Repair/replacement low cut switch suitable size & capacity or as per existing.

6

-

-

... More
(c) Repair/replacement high cut switch suitable size & capacity or as per existing.

6

-

-

... More
(d) Repair/replacement R C network suitable size & capacity or as per existing.

6

-

-

... More
(e) Repair/replacement carbon set suitable size & type or as per existing.

6

-

-

... More
(f) Repair/replacement carbon bush suitable size & type or as per existing.

6

-

-

... More
(g) Repair/replacement/rewinding dimmer suitable size & capacity or as per existing.

6

-

-

... More
(h) Repair/replacement/rewinding buckbook transformer suitable size & capacity or as per existing.

6

-

-

... More
(j) Repair/replacement copper lugs of suitable size or as per existing size.

6

-

-

... More
(k) Repair/replacement PCB (printed circuit board) of suitable size & capacity or as per existing.

6

-

-

... More
(l) Repair/replacement PCB connector of suitable size & capacity or as per existing.

6

-

-

... More
(m) Repair/replacement servo motor of suitable size & capacity or as per existing.

6

-

-

... More
(n) Repair/replacement triger transformer of suitable size & capacity or as per existing.

6

-

-

... More
(o) Repair/replacement digital volt meter.

6

-

-

... More
AQUA GUARD Taking down aqua guard from its position by disconnecting electric connection and separate the usefull components for reuse in the same work and repair/replacement the unserviceable components, complete all as specified and directed by Engineer-in-Charge. NOTE :- Parts replaced of Aqua Guard shall be measured and paid separetly under respective items. (MAKE of spare parts- Kent/ Eureka forbes/ as existing)

10

-

-

... More
(a) PF candle steek

70

-

-

... More
(b) PAC block

10

-

-

... More
(c) AC block

10

-

-

... More
(d) Activation carbon

10

-

-

... More
(e) Photo resistor

10

-

-

... More
(f) PCB rect (exchange basic) hi flow

10

-

-

... More
(g) Solonoid valve

10

-

-

... More
(h) Sensor nut

10

-

-

... More
(j) UV lamp G20T5 (HI FLOW)

10

-

-

... More
(k) PCB assy (hi flow facia) rect (exchange basis)

10

-

-

... More
(l) Heavy metal remover cartridge assy

10

-

-

... More
(m) Eva tube kit

10

-

-

... More
(n) Transformer (inova)

10

-

-

... More
(o) Carbon block

10

-

-

... More
(p) Eva Pipe 2Mtr long

10

-

-

... More
(q) Togle Switch

10

-

-

... More
REVERSE OSMOSIS (R.O) PLANT Taking down R.O. capacity 15/25 ltr/hour from its position by disconnecting electric& water connection, servicing the same by cleaning the filters with the help of clean water and compressed air as required, dismantling the unserviceable part/components, complete all as specified and directed by Engineer-in-Charge. NOTE :- Spare parts shall be measured and paid separetly under respective items. (MAKE of spare parts- Kent/ Eureka forbes/ as existing)

4

-

-

... More
(a) Sediment filter

4

-

-

... More
(b) Low pressure switch

4

-

-

... More
(c) Activated carbon filter

4

-

-

... More
(d) Solenoid valve

4

-

-

... More
(e) Booster pump

2

-

-

... More
(f) TDS Control valve

4

-

-

... More
(g) RO membrane

4

-

-

... More
(h) Flow restrictor Tube

4

-

-

... More
(j) UF Membrane

4

-

-

... More
(k) Non return valve

1

-

-

... More
(l) High pressure switch

1

-

-

... More
(m) Post carbon filter

1

-

-

... More
(n) SMPS unit

1

-

-

... More
(o) UV equaliser with UV lamp Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.