Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_204607_1Bid Award Id
ViewTender No
C/8774/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
156
-
-
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
6.5
-
-
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in coping etc including necessary form work complete all as specified and directed.
1.5
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
300
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
260
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
80
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 35 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
160
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 35 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
100
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 50 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
160
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
120
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 95 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
150
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 120 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
50
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 150 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
50
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 185 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
40
-
-
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 240 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
40
-
-
Dismantling of unserviceable broken LT steel pole/RCC pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as directed. (Note : Earth work wherever invloved shall be measured and paid separately)
8
-
-
Repairs to street light fittings 1X36/40 watt fluorescent tube of any make and model with or without taking down from poles for replacing unserviceable parts of the fitting such as fluorescent lamp, choke, starter, rotary holder etc as required to make the fittings serviceable to the entire satisfaction of Engineer-in-Charge.
(Note: (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of worn out cables as per existing size shall deemed to be included in the unit quoted rate)
28
-
-
Supply only Ballast, electronic type, suitable for 36/40 watts, 240 Volts complete all as specified and directed. (Make : Bajaj/Havell's/CG)
28
-
-
Supply only bipin holder for fluorescent tube light fitting (Make : Bajaj/Havell's/CG)
28
-
-
Taking down and repair at site sodium vapour/Metal halide/MV lamp street light fittings (70/150/250 watt 230/240 volt of any make) and refixing the same in position after replacement of unserviceable/defective part (s) of the fittings such as SV Lamp, Ballast, ignitor, capacitor etc as required to make the fittings in smooth serviceable condition and testing complete and as directed. (Note: (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of worn out cables as per existing size and type shall deemed to be included in the unit quoted rate of this item)
18
-
-
"Supply only" Ballast with copper winding suitable for HPSV Lamp and voltage tapping at 220/240 volt for 150 watt HPSV Lamp complete all as specified and directed
(Make : Bajaj Cat No 162109 BJOS 150 SV/MH or equivelant of make Bajaj/Philips)
6
-
-
"Supply only" Ballast with copper winding suitable for HPSV Lamp and voltage tapping at 220/240 volt for 70 watt HPSV Lamp complete all as specified and directed
(Make : Bajaj Cat No 169408 BJOS 70 SV/MH or equivelant of make Bajaj/Philips)
4
-
-
"Supply only" ignitor for HPSV lamp fittings of 70/150/250 watt complete all as specified and directed
(Make : Bajaj or equivelant of make Bajaj/Cromption/Philips)
6
-
-
"Supply only" porcelain lamp holder suitable for 70/150/250 watt, 240/230 Volts complete all as specified and directed. Cat No 902723 of Bajaj or equivallent of (Make : Havells/Cromption/Philips)
8
-
-
"Supply only" high pressure sodium vapour eliptical coated lamps, 70 Watts, all as specified and directed. Cat No 141070, HPSV 70W elipticalWOI of Bajaj or equivallent of (Make : Cromption/Philips)
4
-
-
"Supply only" high pressure sodium vapour eliptical coated lamps, 150 Watts, all as specified and directed. Cat No 141150, HPSV 150W eliptical of Bajaj or equivallent of (Make : Cromption/Philips)
4
-
-
Taking down old unserviceable light fitting and supply & fix new 60W LED 6000K new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and HF electronic driver, including two run of 2.5 sqmm multi-stranded aluminium flexible wire 3.0 mtrs complete all as specified and as directed. (Make: Havell's Cat No. LHETAXU7PN6J060 (Endwapulse) or equivelant of make Bajaj/Phillips/CG)
6
-
-
Repair to street light fittings for 9/11/36watts CFL or tube Crypton DD series type of any make with or without taking down from poles for replacing unserviceable pacessories of the fittings such as tube, choke, starter, holder etc as required to make the fittings serviceable. (Note: (i) Replacement of unserviceable acessories shall be measured and paid seperately as "supply only" (ii) Replacement of worn out cables as per existing size shall deemed to be included in the unit quoted rate)
160
-
-
"Supply only" CFL Copper ballast 240 volt 9/11 watt open consturction ferro magnetic ballast complete all as specified and directed. (Make : Bajaj, Cat No : 539315 or equivalent model of Philips/Havells).
90
-
-
"Supply only" Copper ballast 240 volt 36/40 watt open consturction ferro magnetic ballast complete all as specified and directed. (Make : Bajaj, Cat No : 539207 or equivalent model of Philips/Havells).
20
-
-
"Supply only" CFL lamp of 11 watt complete all as specified and directed. (Make : Havells Model : non retrofit type, Cat No : PHCS# 011 or equivalent model of Philips/Bajaj)
140
-
-
"Supply only" CFL lamp of 36 watt complete all as specified and directed. (Make : Havells Model : non retrofit type,Cat No : PHCS* 04036 or equivalent model of Philips/Bajaj)
40
-
-
M & L for Stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 20mm with and including 7 / 4 mm galvanised stay strand MS clamp complete including taking down/dismantling existing one all as specified and directed.
(Note : Loop insulator, excavation & earthwork and cement concrete shall be measured and paid separately under relevant items of this Schedule.)
12
-
-
M & L for Galvanised stay strand, size 7/4mm including dismantling unserviceable stay wire complete all as specified and directed.
1.5
-
-
Dismantling old damaged/unserviceable cross arms of MS channel or angle sections etc complete and serviceable materials keep in safe custody for re-use within 50mtrs and unserviceable removing from the site(s) complete all as specified and directed
1.5
-
-
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and directed.
9
-
-
Dismantling of insulators of any type, any size from LT poles of any size and type and serviceable insulator keep in safe custody for re-use and unserviceable insulators removing from the site (s), complete all as specified and directed.
132
-
-
M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
1.5
-
-
S & F aluminium conductor steel reinforced (ACSR) conductor of size 1 of 6/1 x 2.11mm (Squirrel) including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape complete all as specified and directed.
4
-
-
Labour for fixing straining and tightening of old ACSR conductor retrieved under item No 39 hereinbefore including all arrangement/binding wire 2 mm dia/aluminium tape & ACSR Jumpers complete all as specified and directed.
5
-
-
M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65mm dia suitable for 1100 volts grade complete all as specified and directed.
60
-
-
M & L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and directed.
60
-
-
M&L for loop type insulator, vitreous porcelain, white, brown or green , large size, with overall dimensions 90 x 140mm, clearance of hole 25.5mm, etc complete all as specified and directed.
12
-
-
S & F PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system for horizontal two Nos, in span complete all as specified and as directed .
120
-
-
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
123
-
-
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
9060
-
-
M&L for boring / drilling by machines/manual horizontally under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe of any size for drawing the cable complete all as specified and as directed. (GI pipe shall be measured and paid separately).
70
-
-
M & L for 40 mm dia, Galvanised steel tubing, light grade with all fittings for protection of cable laid on road crossing, drain crossing, laid in trenches/floor/road/wall complete all as specified and directed.
50
-
-
M & L for 50 mm dia, Galvanised steel tubing, light grade with all fittings for protection of cable laid on road crossing, drain crossing, laid in trenches/floor/road/wall complete all as specified and directed.
50
-
-
M & L for 80 mm dia, Galvanised steel tubing, light grade with all fittings for protection of cable laid on road crossing, drain crossing, laid in trenches/floor/road/wall complete all as specified and directed.
30
-
-
S&F in repair change over switch 63 Amps, 4 pole complete all as specified and directed. Make : Havells, Cat Part No IHCFFE0063.
3
-
-
Trimming of tree branches around the overhead conductor, poles & stays (not less than 3 metre) to clear the approach of overhead lines including removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including cleaning of creepers climbed on poles and angles, channels and disposed off from site beyond 50m and upto a total distance of 250m complete all as specified and directed by the Engr-in-Charge. (Note : Span of 30 to 50m shall be considered as one unit.)
160
-
-
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including painting (aluminium paint) and writing pole serial number using paint in white colour on black background, complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately)
13
-
-
Repairs to Street light luminaire, compact, 2x24W/ 4X24 watt (Crypton Series for T5) with deep drawn aluminium housing of any make and model with or without taking down from poles for replacing unserviceable parts of the fitting such as 2X24 watt ballast, T-5 tube and bipin holder etc as required make the fittings serviceable to the entire satisfaction of Engineer-in-Charge.
(Note: (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of worn out cables as per existing size shall deemed to be included in the unit quoted rate)
200
-
-
Supply only Ballast, electronic type, suitable for 2X24 watt suitable for T 5 fitting crypton series 240 volts complete all as specified and directed. (Make : Bajaj/Havell's/CG)
160
-
-
Supply only bipin holder for T 5 tube light fittings (Make : Bajaj/Havell's/CG)
140
-
-
Supply only 24 watts tube (Make : Bajaj/Havell's/CG)
250
-
-
S & F LED 12 watt dome post lantern, prewired with all accessories and lamp including taking down old one complete all as specified and directed. Make Havells Cat No LHLC16145099 or eqivalent of Philips/Bajaj/ CG
6
-
-
S & F LED 20 watt street light fitting in aluminium PDC housing, toughened glass cover with IP- 65 protection complete all as specified and directed. Make Bajaj Cat No BCLST 20W LEDI or eqivalent of Havells/Philips/Wipro
22
-
-
S & F LED 40 watt street light fitting in aluminium PDC housing, toughened glass cover with IP- 65 protection complete all as specified and directed. Make Bajaj Cat No BRTFG 45 LEDI or eqivalent of Havells/Philips/Wipro
12
-
-
Taking down existing old/unservicible MCCBs of any descriptions from LT panel board complete all as specified and directed.
12
-
-
M & L for service connection cable, 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core stranded conductor of 6 Sqmm nominal cross sectional area including taking down old one complete all as specified and directed.
400
-
-
M & L for service connection cable, 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core stranded conductor of 10 Sqmm nominal cross sectional area including taking down old one complete all as specified and directed.
400
-
-
M & L for service connection cable, 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core stranded conductor of 16 Sqmm nominal cross sectional area including taking down old one complete all as specified and directed.
200
-
-
M & L for service connection cable, 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core stranded conductor of 16 Sqmm nominal cross sectional area including taking down old one complete all as specified and directed.
100
-
-
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth strip 32 x 6mm thick by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 300x300x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete including taking down old one as specified and as directed.
12
-
-
Dismantling existing unserviceable GI earth wire, damage cradles of any type from service feeder or distributor span complete all as specified and directed.
2
-
-
M & L for galvanised steel earth wire 4 mm dia (hexagonal/rectangular) used for craddle guarding suitable for LT over head line complete all as specified and directed.
2
-
-
S & F for MCCB, AC, 415 Volts, 250 Amp, breaking capacity 35 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
2
-
-
S & F for MCCB, AC, 415 Volts, 200 Amp, breaking capacity 25 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
1
-
-
S & F for MCCB, AC, 415 Volts, 160 Amp, breaking capacity 36 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
1
-
-
S & F for MCCB, AC, 415 Volts, 125 Amp, breaking capacity 25 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
1
-
-
S & F for MCCB, AC, 415 Volts, 100 Amp, breaking capacity 16 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
4
-
-
S & F for MCCB, AC, 415 Volts, 63 Amp, breaking capacity 16 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
2
-
-
S & F for MCCB, AC, 415 Volts, 400 Amp, breaking capacity 50 KA, 4 Pole, ices = icu = 100% with fixed thermal & fixed magnetic setting, 70-100% complete fixed with LT panel board all as specified and directed. (Make: Havells/Legrand/HPL/INDOASIAN or equivelant approved make as per list of manufacturer)
1
-
-
Dismantling of L.T. lightning arresters any type/size of any capacity with all fittings complete all as specified and directed
6
-
-
M&L for L.T. lightning arresters for outdoor, use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts complete all as specified and directed
6
-
-
S & F in repair Street light bracket arm of length not less than 1.2 m made out of GI tubing, 32 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer in MS clamp complete all as specified and directed.
20
-
-
S & F in repair Street light bracket arm of length not less than 1.2 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer in MS clamp complete all as specified and directed.
20
-
-
S & F Digital LED Ammeter with built in selector switch 0-400 Amps of size 96X96mm with accuracy class 1.0, 3 phase and suitable CT(03) including taking down old one complete all as specified and directed. (Make: WL131010 of L&T Model or equivelant of make AE/Minilac/Kaycee as approved)
3
-
-
S & F Digital LED Voltmeter with built in selector switch 0-500 Volts of dia size 96x96mm with accuracy class 1.0, 3 phase including taking down old one complete all as specified and directed. (Make: WL132010 of L&T Model or equivelant of make AE/ Minilac/Kaycee as approved)
3
-
-
M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 9.00 metre long including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed by the Engr-in-Charge. (Note : Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer).
160
-
-
All as per item No 85 above but RCC pole and painted with one coat cement base paint complete all as specified and directed.
100
-
-
S&F in repair switch fuse unit 200 Amps, 3 pole complete all as specified and directed. Make : Havells, Cat Part No IHSRTE4200.
1
-
-
S&F in repair switch fuse unit 63 Amps, 4 pole complete all as specified and directed. Make : Havells, Cat Part No IHFNFW4063.
2
-
-
S&F in repair change over switch 100 Amps, 4 pole complete all as specified and directed. Make : Havells, Cat Part No IHCFFE0100.
2
-
-
S&F in repair for air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
20
-
-
S&F in repair for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
300
-
-
S&F in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
8
-
-
S&F cast iron cable route indicator with embrossing mark as LT cable, circular type, 75mm dia duly fixed with suitable MS flat iron member to be embeded in PCC (1:3:6) type C1 block of size 150x150x150mm complete all as specified and directed.
60
-
-
S&F in repair for aluminium strip 32 x 6mm (electroplated) including saddles and fixing screws etc. for roof conductors and down conductors above ground level complete all as specified and directed.
60
-
-
S&F in repair for galvanised iron strip 32X6mm burried in ground complete all as specified and directed.
160
-
-
M & L for Preparation of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
300
-
-