Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date17 Apr 2023
Closing Date23 May 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for mild steel TMT bars 6 to 8mm bar, cut to length, bent to shape required, including cranking, bending, lapping etc as required and welding with existing bar complete all as specified and as directed.

1080

-

-

... More
M&L for mild steel TMT deformed bar or twisted bars upto 10mm dia as in stirrups cut to length bent to shape required including cranking ,bending etc and lapping ,welding as directed to the existing one complete all as specified and as directed. Note : Item No 3 to 5: Welding shall be measured and paid separately under appropriate item.

190

-

-

... More
M&L for welding in repairs n. exc 2.5cm in length and thickness of metal to be welded exc.6mm but n.exc. 9mm complete all as specified and as directed.

35

-

-

... More
M&L for welding in repairs exc 2.5cm but n.exc.5cm in length and thickness of metal to be welded exc.9mm but n.exc. 20mm complete all as specified and as directed.

45

-

-

... More
Removing of concrete all around reinforcement upto and including 12 mm dia bar including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap) by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer’s instruction to give it a totally rust free finished steel surface complete all as specified and directed. Make : SIKA/FOSROC or its equivalent make as approved by GE

450

-

-

... More
All as per serial item No. 8 here-in-before including make but above 12mm dia.

1500

-

-

... More
M&L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm and complete all as specified and directed. Make : SIKA/FOSROC or its equivalent make as approved by GE

934

-

-

... More
Supply and application of epoxy zinc rich primer on the prepared steel surface by brush the primer shall have a minimum specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed. Make : SIKA/FOSROC or its equivalent make as approved by GE

2350

-

-

... More
M&L for providing and inserting 12 mm dia of required length @ mild steel shear key of bars/levelling gauges in reinforced/plain concrete as per drawing and direction of Engr-in-Charge including power drilling holes of appropriate diameters to a minimum depth equal to 12 times the diameters of shear key bar/levelling gauge, cleaning the drilled holes of loose dust by blowing , insertion of epoxy from cartridge, placing the shear key bar in position and allowing it to stay undisturbed for 24 hours. Rate shall be include cost of labour, all materials, T&P for power drilling in concrete , epoxy cartridge, plastic nozzle etc, complete including cleaning the drilled holes of loose dust by blowing air complete all as specified and directed. NOTE : - The projection length of shear key shall be more than 10 times its diameter plus half of the thickness of cover to concrete plus bend length. Make : SIKA/FOSROC or its equivalent make as approved by GE

4

-

-

... More
M&L for providing and placing in position free flow non shrink cementations micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28days complete all as specified and as directed. Make : SIKA/FOSROC or its equivalent make as approved by GE

5

-

-

... More
Supply, mixing and application two component structural grade polymer modified reinstatement mortar, where local spelling has taken place or shuttering is not possible. The mortar can be applying in layers not exceeding 6mm thick in each layer in and upto any average thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimum compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimum compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimum flexural strength 6.5N/mm2 complete all as specified and as directed. Make : SIKA/FOSROC or its equivalent make as approved by GE

50

-

-

... More
M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and as directed. Make : SIKA/FOSROC or its equivalent make as approved by GE

337

-

-

... More
M&L for providing reinforced cement concrete (1:1½: 3) type A-0 (using 12.5mm graded stone aggregate) mixed with integral water proofing liquid admixture as per manufactures instructions as in columns, pillars, piers, posts and struts complete all as specified and as directed.

5

-

-

... More
All as per serial item No. 16 here-in-before but beams, lintel, cantilevers.

4

-

-

... More
All as per serial item No. 16 here-in-before but slab, landing, balcony and similar items.

4

-

-

... More
All as per serial item No. 16 here-in-before but chajja, facia, railing and parapet. Note : Item No 16 to 19 : Integral water proofing liquid admixture shall be measured and paid separately.

2

-

-

... More
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished concrete surfaces complete all as specified and as directed.

40

-

-

... More
M&L for use and waste of formwork to sides of sides and soffits of beams, lintels, floors etc. for rough finished concrete surfaces complete all as specified and as directed.

35

-

-

... More
M&L for use and waste of formwork to parapet, RCC wardrobe and similar items for rough finished concrete surfaces complete all as specified and as directed.

25

-

-

... More
M&L for use and waste of formwork to sides and soffits of chajjas, troughs etc for rough finished concrete surfaces complete all as specified and as directed

55

-

-

... More
M&L for 5mm thick plastering in cement mortar (1:3) on concrete surfaces as in sides of column, lintel, beam, chajjas, facia, railing, RCC wardrobe etc including finish the surface even and smooth without using extra cement complete all as specified and as directed.

300

-

-

... More
Supply only integral water proofing liquid admixture for concrete and mortar complete all as specified and as directed.

17

-

-

... More
M&L for applying three coats of white wash after preparation of new plastered surfaces of wall complete all as specified and as directed.

470

-

-

... More
All as per serial item No. 26 here-in-before but ceiling.

140

-

-

... More
M&L for applying two coats of cement base paint after preparation of new plastered surfaces of wall complete all as specified and as directed.

265

-

-

... More
M&L for applying two coats of distemper oil emulsion over one coat of alkali resistant primer after preparation of new plastered surfaces of wall complete all as specified and as directed.

80

-

-

... More
Surface excavation n.exc 30 cm deep and averaging 15cm depth and getting out soft or loose soil complete all as specified and as directed.

50

-

-

... More
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out soft / loose soil complete all as specified and as directed.

18

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and as directed.

20

-

-

... More
Removing of soil to distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.

24

-

-

... More
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling complete all as specified and as directed.

5

-

-

... More
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.

4

-

-

... More
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in RCC slab and roof beam complete all as specified and as directed.

7

-

-

... More
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in RCC column, foundation and plinth beam complete all as specified and as directed.

9

-

-

... More
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in RCC Band/chajjas complete all as specified and as directed.

3

-

-

... More
M&F for form work to the roof slab, soffit, side of RCC roof bend and slab including finish the surface even and fair complete all as specified and as directed.

60

-

-

... More
M&L for form work to the side of footing of column and plinth beam complete all as specified and as directed.

30

-

-

... More
M&L for form work to the side of RCC column including finish the surface even and fair complete all as specified and as directed.

50

-

-

... More
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.

30

-

-

... More
M&L for form work to the soffit and side of RCC chajjas including finish the surface even and fair complete all as specified and as directed.

10

-

-

... More
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean radius in cement mortar (1:6) complete all as specified and as directed.

26

-

-

... More
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.

10

-

-

... More
M&L for 75mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.

40

-

-

... More
M&L for 40mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in screed bed to floor complete all as specified and as directed.

40

-

-

... More
M&L for 20-25mm thick machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed.

40

-

-

... More
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.

6

-

-

... More
S&F rolled mild steel Fe 410-W (Gde-E- 250) quality-A framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work complete all as specified and as directed.

70

-

-

... More
S&F steel ventilator with top hung shutter including hinges, steel peg stay etc complete all as specified and as directed.

1

-

-

... More
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.

2

-

-

... More
S&F Steel rolling shutters, 1.25 mm thickness of laths, with out ball bearing, including top cover, anchoring rod, hasp and staple, push pull or manual type and one shop coat of primer, erected in position as indicated complete all as specified and as directed.

5

-

-

... More
M&L for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment: (a) Apply bitumenus primer @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (b) Apply 3mm thick APP plastomeric bitumen based mineral finished water proofing membrane polyster reinforced (4kg/sqm) with 10 cm over laps at joints and laid with LPG torch over lap sealed and finished neat including surface preparation before and after application of treatment as per manufactures instruction complete all as specified and as directed. (c) The Finished surface be given bituminous based aluminium paint as per manufacturer's instructions complete all as specified and directed.

50

-

-

... More
M&L for Plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in holdfast including use and necessary formwork complete all as specified and directed.

0.1

-

-

... More
M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and as directed .

30

-

-

... More
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.

100

-

-

... More
M&L for 15mm thick rendering in cement mortar (1:6) other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.

110

-

-

... More
M&L for 5mm thick rendering in cement mortar (1:3) on concrete surfaces in ceiling, finished the surfaces even and smooth without using extra cement complete all as specified and as directed.

50

-

-

... More
M&L for 20mm thick rendering in cement mortar (1:4) in two layer (12+8)mm thick in each layer and mixed with integral water proofing liquid admixture on top layer of external surfaces of brick work or concrete surfaces including finished the surfaces even and smooth complete all as specified and as directed. Note : Integral water proofing liquid admixture shall be measured and paid separately.

110

-

-

... More
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and as directed.

450

-

-

... More
M&L for hardcore with broken stoneor boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.

8.5

-

-

... More
M&L for 75mm thick plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in flooring / plinth protection laid in alternative bays and joints shall be filled up with bituminous gola with 80/25 bitumen ( 1 part of bitumen to be mixed with 3 part of sand ) including finish the surface even and fair complete all as specified and as directed.

30

-

-

... More
M&L for ATT in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and as directed.

24

-

-

... More
M&L for ATT to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.

40

-

-

... More
M&L for ATT to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.

20

-

-

... More
M&L for ATT to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.

18

-

-

... More
M&L for 100mm thick plain cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foot path with using extra cement and finishing cement concrete surface even and smoothcomplete all as specified and as directed.

50

-

-

... More
M&L for providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all as per architectural drawings complete all as specified and as directed.

250

-

-

... More
M&L for 4.8 mm thick tinted sheet glass ordinary quality and glazing with rubber gasket in square exc 0.5 Sqm in each pane of door window with necessary fitting complete all as specified and as directed.

45

-

-

... More
M&L for 12mm thick Prelaminated particle board interior grade, prelaminated both sides with decorative choice laminates and fixed to aluminium framework as in partition etc. including necessary fitting complete all as specified and directed.

75

-

-

... More
S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.

10

-

-

... More
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.

8

-

-

... More
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc. of any descriptions, keep serviceable bricks in safe custody for re-use complete all as specified and as directed.

6

-

-

... More
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:6) complete all as specified and as directed.

60

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.

10

-

-

... More
M&L for coloured glazed ceramic tiles of size 450 x 300 x 7mm thick as in vertical surface such as in dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including screed bed or bedding layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed.

50

-

-

... More
M&L for 10 mm thick vitrified ceramic tiles (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors / skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 20mm thick in cement mortar (1:6) complete all as specified and as directed.

50

-

-

... More
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed.

375

-

-

... More
M&L 5 mm thick plain colour PVC prelam sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and as directed.

150

-

-

... More
S&F false ceiling with aluminium anodised snap grid of size 605X605mm to support the boards / tiles including hanging proper hanging arrangement with anodized galvanised iron wire and adjuster complete all as specified and as directed.

50

-

-

... More
S&F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed.

50

-

-

... More
S&F 6mm thick high pressure steam cured non asbestos fibre cement designer ceiling board of size to suit grid mould (605 x 605mm as specified above) and fix in grid mould with necessary fixing arrangement as per manufacturer’s instruction including taking down complete all as specified and directed.

50

-

-

... More
Taking down carefully point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket etc and making good disturbed surface of wall/floor etc complete all as specified and as directed.

68

-

-

... More
M&L for One light/fan point controlled by one switch with point wiring 1.5 sq. mm FRLSH grade PVC insulated cable as per IS - 694 stranded copper conductor cable drawn through in and including in stove enamelled steel conduit complete with all fittings and accessories including MS sunk box of thinkness 1.6 mm and hylem sheet cover of 3mm thick for mounting of switches, sockets, regulators, etc and 1.5 mm stranded copper conductor cable FRLSH grade PVC insulated for earth continuity complete all as specified and as directed.

11

-

-

... More
All as per serial item No.85 here-in-before but one 3 pin socket outlet 15 amps, independent, with cables 4 sq.mm size.

5

-

-

... More
M&L for submain wiring with two runs of single core 4 sqmm FRLS PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into steel conduit and all necessary fittings including 4 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and as directed. NOTE:- (i) Three runs of cable 1.5 Sqmm shall be measured as one RM of sub main wiring.

50

-

-

... More
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volt AC complete all as specified and as directed.

2

-

-

... More
S&F flame proof, water proof rotary type switch with cable termination box in LM6 material single pole, ON and OFF 16 amps complete all as specified and as directed.

11

-

-

... More
S&F flame proof switch socket and plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified and as directed.

3

-

-

... More
Fixing only flame proof switch socket and plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified and as directed.

2

-

-

... More
S&F as in repairs LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed. Make: Crompton, Cat part No. EXTN1LT8-16 or its its equivalent model from make as specified in particular specifications.

4

-

-

... More
Fixing only LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed.

6

-

-

... More
M&L for 5 to 10 mm dia of neck mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed.

3

-

-

... More
M&L for point wiring with 1.5 sqmm FRLS grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC cassing and capping (not less than 20 mm wide) complete with all acessories including PVC board/ box of suitable size for mounting of switches, sockets, regulators etc including 1.5 sq mm stranded copper conductor cable FRLS grade PVC insulated and unsheathed as erathing continuity conductor for One light Point controlled by one way switch complete by maintaining the colour code all as specified and directed.

20

-

-

... More
All as per serial item No 95 here-in-before but for One Ceiling /Exhaust Fan Point controlled by one way switch.

4

-

-

... More
All as per serial item No 95 here-in-before but for 5 amps socket point on independent board.

12

-

-

... More
All as per serial item No 95 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board, using 2.5 sqmm earth continuity conductor.

16

-

-

... More
S&F Switch piano flush type, 6 Amps 240 volts single pole one way complete all as specified and as directed.

36

-

-

... More
S&F Socket outlet, 5 pin 6 Amps, flush type complete all as specified and as directed.

12

-

-

... More
S&F Socket outlet 15/16 Amps, 6 in 1, flush type complete all as specified and as directed.

16

-

-

... More
S&F Switch piano flush type,15/16 Amps 240 volts single pole one way complete all as specified and as directed.

16

-

-

... More
S&F Fan regulator electronic type, rotary step, socket type 240 volts complete all as specified and as directed.

4

-

-

... More
Fixing only LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

6

-

-

... More
S&F LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

10

-

-

... More
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.

4

-

-

... More
Fixing only LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.

2

-

-

... More
Taking down ceiling fan / exhaust fan/ wall fan including ceiling cable of any Size / Sweep and Make by disconnecting electric connection, dismantling blades, down rod and removing ceiling fan complete all as specified and as directed.

6

-

-

... More
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.

4

-

-

... More
S&F flame proof exhaust fan 457(18") mm sweep, 1400 RPM single phase complete all as specified and as directed.

1

-

-

... More
Fixing only flame proof exhaust fan 457(18") mm sweep, 1400 RPM single phase complete all as specified and as directed.

1

-

-

... More
Taking down / out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, etc. of any descriptions, laid in trenches and /or fixing with walls /poles including segregating of serviceable materials viz bricks, cables, etc. and kept in Safe custody for re-use, complete all as specified and as directed. (NOTE : Earth Work shall be measured and paid separately under relevant Items here-in-after)

100

-

-

... More
Excavation in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth and getting out as in soft / loose soil, complete all as specified and as directed.

18

-

-

... More
M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core, complete all as specified and as directed.

100

-

-

... More
M&L for Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of payment, punning thickness of Sand cushioning shall only be measured).

7

-

-

... More
S&F Sub-Class 'B' brick, well burnt, laid breadth-wise along the length of Cable laid in trenches over sand cushion laid for UG Cable protection complete all as specified and as directed.

720

-

-

... More
S&F VTPN DB , 415 volt, 4 way, 100 Amp Bus Bar with metal door having facility for MCCB incomming up to 250 Amps and MCB out going complete all as specified and directed. Make: L&T Cat No. DBVTH004DD or its equivalent model from make as specified in particular specifications.

1

-

-

... More
S&F MCCB 125 Amps current carrying capacity 415 volts, 25 KA, 4 pole thermal magnetic type along with spreader terminals complete all as specified and as directed.

1

-

-

... More
S&F 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.

14

-

-

... More
S&F 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.

2

-

-

... More
M&L for submain wiring with two runs of single core 6 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed. NOTE:- (i) Three runs of cable 6 Sqmm shall be measured as one RM of sub main wiring.

50

-

-

... More
M&L for submain wiring with two runs of single core 10 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 10 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed. NOTE:- (i) Three runs of cable 10 Sqmm shall be measured as one RM of sub main wiring.

60

-

-

... More
S&F as in repairs SP&N DBs, double door, 240 volt, 8 way complete all as specified and as directed. MAKE:- L&T Cat part No. DBSPN008DD or its equivalent model from make as specified in particular specifications.

2

-

-

... More
M&L for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanise iron strip 32 x 6 mm as earthing lead means of nuts, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to test point or as directed including Pit in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC Cover of size 450X450X50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, galvanised Iron wire mesh, funnel, galvanised Iron watering pipe 20mm bore medium grade, including necessary excavation in soft/ loose soil, returning, filling in and removal of surplus soil upto a distance of 50.00 mtr and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion, including taking down old unserviceable earthing complete all as specified and as directed.

4

-

-

... More
S&F as in repairs building security light 30 watt LED light fitting, new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP-65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver, complete all as specified and as directed. Make:Crompton Cat No.LSTS-30-CDL-M or its equivalent model from make as specified in particular specifications.

2

-

-

... More
S&F bracket fabricated on pole street light out of GI tubing light grade 40mm bore bend to the shape and length 1.0 mtr complete with mounting MS clamp of flat iron size 25x5 mm of suitable length 02 pairs including nut bolts etc of suitable size and painting to MS clamp with two coats of aluminium paint over one coat of red oxide metal primer complete all as specified and as directed. Note:- The contract sum shall be calculated by deducting the amount shown in schedule of credit attached to this tender, from total amount of Schedule 'A'/BOQ

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.