Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Sep 2024
Closing Date30 Sep 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
NOTES:- (Applicable for BOQ Serial Item No. 1.00 to 3.00 here in before) (i) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of DG Sets (ii) Preventive and Corrective Maintenance : The authorised Service Engineer of OEM or OEM Certified agencies shall visit the site once in a month for carrying out preventive and corrective maintenance on all the units installed at site. This includes maintenance of all mechanical, electrical and electronic parts / sub-assemblies. The preventive maintenance report will be as per the Original Equipment Manufacturer's instructions and as specified in Particular Specification. The Contractor may claim payment on monthly basis. In that case the payment shall be made with pro-rata basis on quoted rates. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) TEZPUR officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during comprehensive maintenence period.

-

-

-

... More
(iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately under Prime Cost Sum and supply here- in -after. (vii) The Contractor shall maintain service reports for all visits & breakdown visits & copy of the same will be submitted every month to the Engineer in Charge.

-

-

-

... More
Supply Only the following spares for 62.5 KVA DG Sets as per OEM's specifications,complete all as specified. [OEM:Kirloskar:MES No.- NYA, ) Location - DM RANGE]

-

-

-

... More
(a) SPIN ON FILTER, Cat No.- 06.436.01.0.00

4

-

-

... More
(b) FUEL FILTER KIT, Cat No. - 48.999.20.0.00

4

-

-

... More
(c) PRIMARY FILTER ELEMENT, Cat No.- 06.757.03.0.00

1

-

-

... More
(d) SECONDARY ELEMENT, Cat No.- 06.757.04.0.00

1

-

-

... More
(e) CONTROL UNIT, Cat No.- 02.999.91.0.SP

1

-

-

... More
(f) ENGINE WIRING HARNESS, Cat No.- 4H.905.20.0.00

1

-

-

... More
(g) AVR, Cat No.- 2H.811.32.0.00

1

-

-

... More
(h) DIODE ASSEMBLY

1

-

-

... More
(j) DIODE PLATE

1

-

-

... More
(k) GOVERNOR CARD

1

-

-

... More
(l) FUEL PIPE, Cat No.- 4H.031.04.0.00

1

-

-

... More
(m) FUEL PIPE, Cat No.- 4H.031.05.0.00

1

-

-

... More
(n) Hose Pipe

1

-

-

... More
Supply only following spares for replacement against unserviceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, for 40 KVA Cummins make Engine. MES No.- NYA, Location - DM Range

-

-

-

... More
(a) Element Oil Filter, Cat No.- 01220962

4

-

-

... More
(b) Element Fuel Filter, Cat No. - 01492967

4

-

-

... More
(c) Element Air Cleaner, Cat No.- 3814695

1

-

-

... More
(d) Element Air Cleaner, Cat No.- 3814696

1

-

-

... More
(e) Panel Control, Cat No.- A054G527

1

-

-

... More
Supply only following spares for replacement against unserviceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, for 40 KVA Crompton make Engine. MES No.- NYA, Location - DM Range

-

-

-

... More
(a) Lub Oil Filter, Cat No.- 605411880008

8

-

-

... More
(b) Filter Element with O Ring, Cat No. - 001200240911.

8

-

-

... More
(c) Filter insrt with O ring, Cat No.- 001200240912.

8

-

-

... More
(d) Air filter element, Cat No.- P21109230031.

2

-

-

... More
(e) Air Pre filter element, Cat No.- P21109230032.

2

-

-

... More
(f) Relay Card, Cat No.- 141100195217.

1

-

-

... More
(g) Governor, Cat No.- 106902090056.

1

-

-

... More
(h) Mag pick up, Cat No.- 105652190001.

2

-

-

... More
Supply only following spares for replacement against unserviceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, for 320 KVA Kirloskar make Engine. MES No.- NYA, Location - DM Range

-

-

-

... More
(a) LUB OIL FILTER, Cat No.- DV0.014.11.0.00

2

-

-

... More
(b) LUB OIL FILTER, Cat No.- DV0.014.27.0.00

2

-

-

... More
(c) FUEL FILTER CARTRIDGE, Cat No.- DV0.020.03.0.00

4

-

-

... More
(d) AIR CLEANER PRIMARY ELEMENT, Cat No.- DV8.505.74.0.00

2

-

-

... More
(e) AIR CLEANER SAFETY ELEMENT, Cat No.- DV8.505.75.0.00

2

-

-

... More
(f)THERMOSTAT ELEMENT for 320 KVA, Cat No.- KL6.055.34.0.00

1

-

-

... More
(g) LUBE OIL TEMP GAUGE for 320 KVA DG Set, Cat No.- 34.183.03.0.00

1

-

-

... More
(h) LUBE OIL PRESS SENDOR 0.75 +/- 0.15 B for 320 KVA DG Set, Cat No.- 21.279.04.0.00

1

-

-

... More
(J) LUBE OIL TEMP GAUGE for 320 KVA DG Set, Cat No.- 34.183.03.0.00

1

-

-

... More
(K)STOP SOLENOID ASSLY: 24VDC for 320 KVA DG Set, Cat No.-F6.399.10.0.00

1

-

-

... More
(L) FUEL STOP SOLENOID ASSEMBLY (ELECTRAL CONTROL MAKE,INDIGENIOUS, ENERGIZE TO STOP TYPE,24VDC) WITH SUITABLE LINKAGE & HARDWARE for 320 KVA DG Set, Cat No.-F6.1356.20.0.00

1

-

-

... More
(M) LOW OIL PRES SWITCH 1.7KG/CMSQ for 320 KVA DG Set, Cat No.- 49.156.01.0.00

1

-

-

... More
Supply only following spares for replacement against unserviceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, for 35 KVA Kirloskar make Engine. MES No.- NYA, Location - DM Range

-

-

-

... More
(a) SPINON LUBE OIL FILTER, Cat No.- 04.270.01.0.00

1

-

-

... More
(b) FUEL FILTER ELEMENT PRIMARY, Cat No.- 3H.132.01.0.00

1

-

-

... More
(c) FUEL FILTER ELEMENT SECONDARY, Cat No.- 3H.132.02.0.00

1

-

-

... More
(d) PRIMARY AIR CLEANER ELEMENT, Cat No.- 04.586.03.0.00

1

-

-

... More
(e) AIR CLEANER SAFETY ELEMEN, Cat No.- 04.586.04.0.00

1

-

-

... More
(f) OIL BATH AIR CLEANER WITH RUBBER SLEEVE, Cat No.-03.061.70.0.00

1

-

-

... More
Supply only following spares for replacement against unserviceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, for 15 KVA Kirloskar make Engine. MES No.- NYA, Location - DM Range

-

-

-

... More
(a) LUBE OIL FILTER ELEMENT, Cat No.- 03.040.19.0.00

1

-

-

... More
(b) PREFILTER ELEMENT, Cat No.- 34.032.02.0.00

1

-

-

... More
(c) FUEL FILTER ELEMENT, Cat No.- 34.032.12.0.00

1

-

-

... More
(d) PRIMARY AIR CLEANER ELEMENT, Cat No.- 04.586.03.0.00

1

-

-

... More
(e) AIR CLEANER SAFETY ELEMENT, Cat No.- 04.586.04.0.00

1

-

-

... More
(N) KG645 CONTROLLER UNIT WITH 4-20MA for 10 KVA to 160 KVA DG Set, Cat No.-02.026.09.0.00

1

-

-

... More
(O) WIRING HARNESS for KG 645: 4R1040, Cat No.-4H.905.20.0.00

1

-

-

... More
(P) STOP SOLENOID ASSLY-12VDC SINGLE COIL for 10 KVA to 160 KVA DG Set, Cat No.- 4H.150.30.0.00

1

-

-

... More
(Q) KIRLOSKAR GREEN AVR (MODEL : TAVR-10/TAVR-20/TAVR-14 for 10 KVA to 82.5 KVA DG Set, Cat No.- 2H.811.32.0.00

1

-

-

... More
® ADV LOAD DUMP MODULE 24VDC, Cat No.DV8.858.16.0.00

1

-

-

... More
(S) 24 V DC RELAY BOARD 2CH. (70 AMP.) 1C/O. BATTERY -VE SIGNAL,DIN MOUNTED, Cat NO.- KV8.853.05.0.00

1

-

-

... More
Calibrating fuel injector system to simulate closely the function of fuel injectors in the fuel injection system of diesel (compression-ignition) engine of 30 KVA to 87.5 KVA capacity DG Set in order to comply with the higher injection pressures,including replacement of minor spares,repair and servicing of injector nozzles,complete all as specified and directed.

2

-

-

... More
Taking down carefully,radiator and water pump assembly from engine of DG Set of Capacity 320KVA for repairing, brazing in leaking points of circulatory pipe line,upper & lower tanks of the radiator assembly if any,descaling and cleaning throughly tanks & circulatory pipeline,cleaning of fins of radiator assembly and water pump internally,including replacement of defective spares as required and including reinstallation of the radiator and water pump assembly in original position including testing and commissioning,& connected accessories as per OEM recommendation through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed

2

-

-

... More
Overhauling of Self Starter 24 Volts of DG Set of capacity 250-750 KVA by opening up,cleaning of parts,lubrication and replacement of defective parts including re-assembling all as required for smooth functioning of self starter,& connected accessories as per OEM recommendation through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed Notes:- (i) Cost of minor spares such nuts,bolts,screws,washers, insulation sleeves, lugs,lubricants etc. required for maintenance shall be deemed to be included in the unit rate quoted. (ii) Spares required to be replaced shall be measured and paid separately under relevant items of this BOQ. (iii) Spares replaced shall be guaranteed for two years. (iv) Self starter shall be tested in presence of Engineer in Charge and the cost of testing shall be deemed to be included in the quoted rate.

1

-

-

... More
Supply Only the following spares suitable for Self Starter 24 Volts of DG Set of capacity 250-750 KVA as per OEM's specifications, all as specified. [Make: LUCAS/TVS/VALEO]

-

-

-

... More
Clutch Assembly.

1

-

-

... More
Bendix Pinion

1

-

-

... More
Solenoid Switch

1

-

-

... More
Carbon Brush

1

-

-

... More
Armature Field Coil

1

-

-

... More
Bush

1

-

-

... More
Armature assembly

1

-

-

... More
Supply and Fix in repair,switched mode power supply (SMPS) based design battery charger,12 Volts,10 Amps,charging capacity for 7 AH to 220 AH lead acid battery,with protection against reverse polarity of battery and automatic over current limit & intelligent thermal management,digital display for charging Amp and DC Volt with over voltage, under voltage and current protection and easy battery connection with clip leads,suitable for AMF Panels of DG Sets of capacity 40-160KVA all as per OEM's reccommendations,complete all as specified and directed.

1

-

-

... More
Supply and Fix in repair,switched mode power supply (SMPS) based design battery charger,24 Volts,10 Amps,charging capacity upto 220 AH lead acid batteries,with protection against reverse polarity of battery and automatic over current limit & intelligent thermal management,digital display for charging Amp and DC Volt with over voltage, under voltage and current protection and easy battery connection with clip leads,suitable for AMF Panels of DG Sets of capacity 250-750 KVA all as per OEM's reccommendations,complete all as specified and directed.

1

-

-

... More
Supply and filling in replacement of Engine oil 20W40 210 litres to top up/ refilling of all DG set as per the direction of Engineer-in-charge.(Make Gulf/Castrol/Volvalin)

330

-

-

... More
Supply and pouring distilled water for battery and as directed .

120

-

-

... More
Supply for pouring of coolant suitable for radiator for Kirloskar/Jackson make engine as per the requirement of time to time as directed by Engr-in-charge for various capacities of DG Set (Make : SERVO/CASTROL/PUROCOOL)

150

-

-

... More
Taking down carefully,radiator and water pump assembly from engine of DG Set of Capacity 40 TO 62.5 KVA for repairing, brazing in leaking points of circulatory pipe line,upper & lower tanks of the radiator assembly if any,descaling and cleaning throughly tanks & circulatory pipeline,cleaning of fins of radiator assembly and water pump internally,including replacement of defective spares as required and including reinstallation of the radiator and water pump assembly & connected accessories in original position including testing and commissioning, as per OEM recommendation through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed

1

-

-

... More
Overhauling of Self Starter 12 Volts of DG Set of capacity 40-160 KVA by opening up,cleaning of parts, lubrication and replacement of defective parts including re-assembling all as required for smooth functioning of self starter,& connected accessories as per OEM recommendation through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed . Notes:- (i) Cost of minor spares such nuts,bolts,screws,washers, insulation sleeves, lugs,lubricants etc. required for maintenance shall be deemed to be included in the unit rate quoted. (ii) Spares required to be replaced shall be measured and paid separately under relevant items of this BOQ. (iii) Spares replaced shall be guaranteed for two years. (iv) Self starter shall be tested in presence of Engineer in Charge and the cost of testing shall be deemed to be included in the quoted rate.

2

-

-

... More
Supply Only the following spares suitable for Self Starter 12 Volts of DG Set of capacity 40-160 KVA as per OEM's specifications, all as specified. [Make: LUCAS/TVS/VALEO]

-

-

-

... More
Clutch Assembly.

2

-

-

... More
Bendix Pinion

2

-

-

... More
Solenoid Switch

2

-

-

... More
Carbon Brush

2

-

-

... More
Armature Field Coil

2

-

-

... More
Bush

2

-

-

... More
Armature assembly

2

-

-

... More
Supply and Fix in repairs,cam operated rotary isolator switch,90º operation complete rotation,3 Pole ON - OFF,63 Amps,complete all as specified and directed. [Cat No.61197 of Make “L&T” or equivalent Model of Make HPL/ AE]

4

-

-

... More
S & F in repairs digital type voltmeter 96 mm X 96 mm, 0-500 V complete all as specified and as directed.

4

-

-

... More
Supply and Fix in repairs,LED Indicator 16 mm with power consumption 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC,colour Red/ Yellow/Blue, complete all as specified and directed. [Cat No. SIL of Make “L&T” or equivalent Model of Make HPL/ AE]

6

-

-

... More
Supply and Fix in repairs, Ammeter digital type 0-300V with selector switch flush mounting square type with CT's of suitable size in repair. Make : AE/L&T/ABB/HPL

4

-

-

... More
Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 100 Ah,suitable for DG Set including provision of brass terminal clamps for connection,complete all as specified and directed. [Model : Xpress (XP1000) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']

3

-

-

... More
Supply and Fix in repairs, maintenance free lead acid battery,12 Volts,capacity 150 Ah,suitable for DG Set including provision of brass terminal clamps for connection,complete all as specified and directed. [Model : Xpress (XP1500) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']

2

-

-

... More
S&F BATTERY CABLE ASSEMBLY (FOR -VE & +VE) for connection of Battery to Self with copper Lugs, copper cable and copper connector of baterry as per existing size for both terminal, complete all as specified and directed.

4

-

-

... More
Taking down carefully existing door shutters not exceeding 1 SqM each from aucoustic enclosures of DG Sets,resecuring or easing and adjusting,including replacement of 02 (Two) Nos of defective mild steel hinges as per OEM's specification,complete all as specified and directed.

12

-

-

... More
Supply Only Magnetic pickup unit complete all as per 16X1.5 THREAD for 320 KVA DG Set, Cat No.- F6.741.16.0.00 DG Set of capacity including taking down old unserviceable as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed

1

-

-

... More
Comprenesive maintenance and repair including renewal/replacement and installation of defective parts of all existing fire detection system complete, repair and upgradation of software including renewal/replacement of defective parts of all existing fire detection system complete consisting of addressable fire control panel, Remote Terminal Unit panels, smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier, Loud speaker, Loop isolator, Zone monitor module, Modem etc. to make 100 % serviceability of the complete incl checking of fire detector, cleaning of heavy greasy deposit if any, checking the connection of batteries, the alarm function of control and indicating eqpt be checked by the operation of trigger device in each zone as described, the system installed in Fire station by visiting every month through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed Note:- (i) Cost of new components shall be paid separately under relevant items. (ii) Contractor's rep shall visit every month to check all fire panel and system to check its functionility and to make them functional. if any defect observed. (iii) He shall take the serviceability certificate duly signed by the user and submit to the department. After obtaining / producing seviceability certificate of system payment will be made to contractor . (iv) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running includes maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment manufacturer's instructions and Specification. The Contractor may claim payment on monthly basis. (v) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF ) TEZPUR) officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period

1

-

-

... More
Supply only of 12 V, 12 AH battery for back up to all FACP panelas per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed

2

-

-

... More
Supply and fixing in repair combined scattered light smoke and temperature multisensor detector programmed to detect either smoke or heat, or both depending on the type of system having sensitivity in accordance with existing fire alarm system of including taking down existing unservicable detectors as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed

2

-

-

... More
Supply and fixing in repair of electronically addressable intelligent resettable type Manual Call Point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed:- a)Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key. d) Ingress Protection IP-24 & Material-ABS for existing L & T Electrical & Automation(schrack-seconet) fire alarm system.

2

-

-

... More
Dismantling of steel tubular pole of any size from bottom by demolition of concrete of any description and size complete all as directed

1

-

-

... More
Supply and fixing swaged & welded MS steel tubular poles, overall length 9.00 metre long, respective O/D 114.3 mm x 88.9 mm x 76.1 mm, wall thickness 3.65 mm x 3.25 mm x 3.25 mm, sectional 5.00 mtr x 2.00 mtr x 2.00 mtr as per 410-SP-25(IS: 2713-1980) single swan neck complete with cast iron base plate, final taper plug, pole cap, bolts/nuts, screws/washes, painting with two coats of black bituminous paint through out internally and externally upto planting depth and two coasts of black and yellow alternate strips 30 cm each upto 1.2 mtr from the ground level. The remaining external position shall be painted with two coat of aluminium paint and one coat of cement based paint on PCC copping of pole including numbering of pole with black syenthic paint/ Stricker including dismantling/removing of old damaged rusted steel tubular/PCC Poles of any description and taking asides including all electrical connection, demolition of existing PCC foundation and making good to disturbed surface complete all as specified and as directed by Engr-in-Charge. (Note:- Earth work, PCC work, shall be measured and paid separately.)

1

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final and Conclusive

128.04

-

-

... More
All as per item No 37.00 here in before but Excavation in trenches exc. 1.5m wide and n. exe 3 mtr depth ,complete all as specified and directed

0.2

-

-

... More
Returning filling in any type of soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.

56.42

-

-

... More
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.

71.62

-

-

... More
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through upto 100 mm bore, galvanised steel tubing,complete all as specified and directed.

10

-

-

... More
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).

41.62

-

-

... More
Taking down/out unserviceable or serviceable LT UG Cables of nominal Cross Sectional Area 95 sqmm 3.5 core and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed.

130

-

-

... More
All as per Item No. 43.00 here in before but nominal Cross-Sectional Area 50 Sqmm 3.5 Core.

100

-

-

... More
All as per Item No. 43.00 here in before but nominal Cross-Sectional Area 35 Sqmm 3.5 Core.

100

-

-

... More
All as per Item No. 43.00 here in before but nominal Cross-Sectional Area 25 Sqmm 4 Core.

150

-

-

... More
All as per Item No. 43.00 here in before but nominal Cross-Sectional Area 16 Sqmm 4 Core. (NOTE for Item No.43 to 47 : Earth Work shall be Measured and Paid for separately under relevant Items).

150

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.

130

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.

100

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.

100

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.

150

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.

150

-

-

... More
S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.

2.8

-

-

... More
Re-laying only old Brick in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 37.00 here-in-before), complete all as directed.

2

-

-

... More
Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches / Walls/Poles complete all as specified and as directed.

36

-

-

... More
Material and labour for 32 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.

12

-

-

... More
Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.

12

-

-

... More
Material and labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.

12

-

-

... More
Supply and Fix in repairs moulded case circuit breakers (MCCBs) for distribution network, Thermal Magnetic trip, conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 kA breaking capacity Ics =100% Icu,415V, AC, 50Hz, with adjustable Over Load setting 0.8 - 1.0 and adjustable Short Circuit setting including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs moulded case circuit breakers (MCCBs) for distribution network, Thermal Magnetic trip, conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 100 Amps and 25 kA breaking capacity Ics =100% Icu,415V, AC, 50Hz, with adjustable Over Load setting 0.8 - 1.0 and adjustable Short Circuit setting including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

1

-

-

... More
Supply and Fix in repairs moulded case circuit breakers (MCCBs) for distribution network, Thermal Magnetic trip, conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 16 kA breaking capacity Ics =100% Icu,415V, AC, 50Hz, with adjustable Over Load setting 0.8 - 1.0 and adjustable Short Circuit setting including all accessories like spreader terminals and seprator etc, making all fixing arrangement in existing location, connecting incoming and outgoing cables complete all as specified and directed.

2

-

-

... More
Materials and Labour for plain cement concrete (1:3:6) Type C-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.

0.5

-

-

... More
Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.

0.5

-

-

... More
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 25 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.

30

-

-

... More
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 40 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.

30

-

-

... More
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 50 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.

30

-

-

... More
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 80 mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paid separately under relevent item.

18

-

-

... More
Material and labour for laying of GI tubing 25 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.

30

-

-

... More
Material and labour for laying of GI tubing 40 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.

30

-

-

... More
Material and labour for laying of GI tubing 50 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.

30

-

-

... More
Material and labour for laying of GI tubing 80 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.

18

-

-

... More
Material and labour for fixing GM globe/gate valve 25 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.

2

-

-

... More
Material and labour for fixing GM globe/gate valve 40 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.

2

-

-

... More
Material and labour for fixing GM globe/gate valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.

2

-

-

... More
Cutting chase for pass through cable protection pipe ,etc.in existing plain cement concrete pavement/ hardstanding/aprons etc. and making good, cutting in plain cement concrete (1:3:6) Type C1(using 20 mm graded aggregate),exceeding 20 cm but not exc 50 cm girth, complete all as specified and directed.

10

-

-

... More
Demolition of cement Concrete (unreinforced) of any description and in any position complete all as specified and directed.

1

-

-

... More
Supply and Fix in repair,Modular Switch, one way,6 Amps,1 Module, complete all as specified and directed.

20

-

-

... More
Supply and Fix in repair,Modular Switch,one way,16 Amps,1 Module, complete all as specified and directed.

20

-

-

... More
Supply and Fix in repair,Modular Socket, 6 Amps, 2/3 Pin, 2 Module, complete all as specified and directed.

20

-

-

... More
Supply and Fix in repair,Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed.

20

-

-

... More
Supply and Fix in repair,Modular Fan step regulator, 120W - 2 module,on the existing hylam laminated sheet etc as required complete all as specified and directed by Engr- in - Charge..

10

-

-

... More
Supply and Fix in repair, LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed.

20

-

-

... More
S&F LED 20 Watt tube light fitting (T8 type) , single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 105 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 housing with aluminium, life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete. . Note : Make of batten and LED tube lamp should be of same make.

30

-

-

... More
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4000, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.

10

-

-

... More
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4200, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L70 and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Wipro/Orient electric

40

-

-

... More
S & F LED street lights nominal power 70 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 8400, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L70 and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Wipro/Orient electric

50

-

-

... More
S & F LED flood lights nominal power 150 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L 70 and IK 10 Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 10 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services and copy of the same shall be submitted along with RAR/FB. . Make Wipro/Orient electric

18

-

-

... More
Supply and Fix in repairs, LED post top light fittings, 40 Watts,CCT 5700°K, Power Factor 95%, AC input voltage 120V-277V,surge protection 5 KV, with aluminium alloy power coated housing and aluminium bright anodised housing, opal polycarbonate diffuser and degree of protection IP-65, complete all as specified and directed. [Cat No.LPTO-40-CDL of Make 'Crompton Greaves' or equivalent Model of Make 'Wipro'/'Philips'/'GE']

2

-

-

... More
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 1.50 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 1.50 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.

50

-

-

... More
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 2.50 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 2.50 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.

50

-

-

... More
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.

50

-

-

... More
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.

50

-

-

... More
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with including taking down existing unserviceable DB complete all as specified and directed. .Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.

2

-

-

... More
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with including taking down existing unserviceable DB complete all as specified and directed. .Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.

4

-

-

... More
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.

28

-

-

... More
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 6A to 32 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.

6

-

-

... More
Supply, installation,testing and commissioning of Street Light Panel (Outdoor Type) 3 Phase, 415 Volt 6 KW, Digital timer, power contactor rating 32 Amp TP, including MCB TPN suitable size complete all as specified and direcetd. [Cat No IHXTS03060 of Make'Havells'or equivalent Model of Make Indo Asian/C&S Electric] Note:- The panel shall be fitted on MS angle iron frame of ISA 50x50x5mm at a height of 0.5 Metres above GL including PCC foundation (1:2:4) Type B1 for legs of the frame including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and including treating grouted portion of legs embedded in concrete with coal tar paint or as per OEM recommendation and cost of the same deemed to be included in quoated rates.

1

-

-

... More
Comprehensive servicing for Split Type Air Conditioner (both indoor and outdoor ) of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for split AC etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. MAKE LG/Carrier/Samsung/Amtrex/Videcon /Hitachi/Blue star (i)S&F spare parts will be measured and paid separately under relevant item. (ii) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Air Conditioners including maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) TEZPUR officials or their representatives, The OEM's authorised service representative or OEM certified agencies or approved will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any

10

-

-

... More
M&L for rewinding/ repairing of blower fan motor of AC of capacity 1.5/2 TR Split AC by disconnecting the electrical connection of burnt out electric outdoor motor and dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed.

5

-

-

... More
Supply only Condenser coil copper assembly complete suitable for Split type AC 1.5 /2.0 TR as per OEMs specifications, including taking down of defective coil complete.

5

-

-

... More
Supply Only evaporator coil assembly complete suitable for 1.5 / 2 Split type AC as per OEM's specifications including taking down of defective coil complete.

5

-

-

... More
Supply,installation,testing and commissioning of sealed compressor including charging of refrigerant gas, leak testing complete as per OEM recommendation .,suitable for outdoor unit of Split type AC of 1.5 Ton capapicy as per OEM's specifications including taking down carefully existing unserviceable compressor, complete all as specified and directed.

3

-

-

... More
Supply Only, running capacitor 36/45 Mfd 440V AC 50 Hz for outdoor unit of Split type AC of 1.5/2.0 Ton capapicy as per OEM's specifications.

5

-

-

... More
Supply Only,Fan motor capacitor 4 / 6 Mfd 440V AC 50 Hz for outdoor unit of Split type AC of 1.5/2.0 Ton capapicy as per OEM's specifications.

5

-

-

... More
Supply only Air filter suitable for split /window type AC,1.5 TR capacity as per OEM's specifications.

5

-

-

... More
Supply only, Start Relay for compressor of Window/Split type AC of 1.5/2.0 Ton capapicy as per OEM's specifications.

5

-

-

... More
Supply Only, thermostat of Window/Split type AC of 1.5/2.0 Ton capacity as per OEM's specifications.

4

-

-

... More
Supply and Fix in repair, fan motor for out door unit of 1.5 TR/ 2 Ton capacity as per OEM's specifications.

4

-

-

... More
Supply and Fix in repair,Copper pipe 5 /8" including connected fittings complete with insulation as per OEM's specifications for inter connection of indoor and outdoor units of split type AC complete .

15

-

-

... More
Supply and Fix in repair,Copper pipe 3 /8" including connected fittings complete with insulation as per OEM's specifications for interconnection of indoor and outdoor units of split type AC complete .

15

-

-

... More
Supply & Charging R-22 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge. (Contractor shall be check leakage in the system before filling of gas).

15

-

-

... More
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtr below ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction of inspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately(Note : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with 4 x Bags of bentonite clay of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986. (vii) The cost of Copper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.

8

-

-

... More
Materials and Labour for maintenance free chemical earthing system using 04 (four) spike 17.2mm dia, 3000mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Under Writers laboratories (UL) 467-2007 or latest with 250mm long copper strips of size 50X3 mm, exothermally welded on top of electrode complete including augering (boring) 100-125mm dia hole as required for electrode in any type of soil and back filling with Earth Enhancing Chemical back filled compound as per IEEE 80 2000 Clause 14.5(c), conforming to IEC 62561-7, min quantity of compound used 40Kg ), i.e. total qty 160 Kg per electrode or more quantity of BFC if required to achive less than one ohms). The remaining portion of earth pit to be filled with agriculture soil / black cotton soil free from stones etc to be bring from out side defence land , conforming to IEEE/BS standrads including pit cover light weight made out of high quality polymer with lid made of HDG steel, including nessary testings and commissioning, complete all as specified and as directed. Notes:- (i) The work of earthing shall be carried out by authorised trained rep of OEM. (ii) The acceptable earth resistance at earth busbar/ test point shall be as per users requirement as desired by Engr-in-Charge but it should be below 01 Ohm. At certain locations, it may not be possible to achieve desired earth resistance with one electrode / pit due to higher soil resistivity,in such cases, provision of loop earthing consisting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. (iii) The procedure mentioned here-in-before for one earth pit shall be repeated for other earth pits. (iv) Additional earth electrode pits and loop conductor shall be measured and paid seperately . (v) The quoted rate shall also be included the following elements: (a) Complete earthwork including drilling holes for electrode.(b) Earhing electrode-01(One) No Only (c) Backfilling carbon based ground enhancing compound (GEC). (d) Pit cover light weight made out of high quality polymer with lid made of HDG steel. (e) Soil suitable for agricultural purpose required for each pit. (f) Copper strip as earthing lead of size 50mmx3mm, 250 mm long only, beyond 250mm, other size will be measured and paid for separately under respective item(s) in this BOQ. (g) All Labour and T&P required including testing of earth network.

8

-

-

... More
Supply and fixing copper strip of size 20 x 3.15 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator, 4 BM, heavy duty ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates)

287

-

-

... More
Taking down old ceiling fan/Exhaust fans/Wall mounting fans/ Cabin Fan of any capacity/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carry out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with lubricant as per OEMs specification, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position , replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. complete all as specified and directed. NOTE: (i) Rewinding and replacement of defective parts, Painting etc shall be measured and paid seperately.

25

-

-

... More
M&L for Rewinding of ceiling fan of sweep 1200/1400 mm any make any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specification, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.

20

-

-

... More
M&L for Rewinding of Exhaust fan/Wall Fan/Cabin Fan any sweep , make and any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs specification, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.

5

-

-

... More
Materials and labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.

10

-

-

... More
Materials and labour for painting of Pedestal fans/Exhaust Fan/Wall Fan/Cabin Fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.

5

-

-

... More
Materials and Labour for painting of pedestal fans of any size/sweep complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.,complete all as specified and as directed.

10

-

-

... More
Supply Only,Gun Metal Bushing/Sleeve Bearing of suitable for shaft size.

5

-

-

... More
Supply Only,Capacitors for electric fan motors, 2.5 mfd, 440 V conforming to IS:1709 (Cat No. QHPCWC5002X5 of Make Havells or equivalent Model of Make UNIVERSAL/EPCOS)

10

-

-

... More
Supply Only,Capacitors for electric fan motors,4 mfd, 440 V conforming to IS: 1709 (Cat No. QHPCWC5003X1 of Make Havells or equivalent Model of Make UNIVERSAL/EPCOS)

4

-

-

... More
Supply Only,Chrome Steel Ball Bearing,size 6201 for fan as per OEMs specifications. (Make: TATA/NBC/SKF)

2

-

-

... More
Supply only, chrome steel ball bearings, size 6003 for fan as per OEMs specifications. (Make: TATA/NBC/SKF)

2

-

-

... More
Supply Only,Chrome Steel Ball Bearing,size 6202 for ceiling fan as per OEMs specifications. (Make: TATA/NBC/SKF)

1

-

-

... More
Supply Only,Chrome Steel Ball Bearing,size 6204 for ceiling fan as per OEMs specifications. (Make: TATA/NBC/SKF)

4

-

-

... More
Taking down carefully, existing defective storage type water heater (geyser) of Capacity 25/50 Litres of any Make for repairing, including replacement of defective spares as required including descaling of storage tanks internally, brazing of leakage if any in tanks and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning,complete all as specified and directed. NOTES:- (i) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately.

10

-

-

... More
Supply Only,Thermostat, stem type,adjustable upto 75 Degree Celcius, ISI Marked (IS 3017).

4

-

-

... More
Supply Only,Heating Element, 2000 Watts for geyser as per OEM's specifications.

5

-

-

... More
Supply Only,brass pressure relive valve suitable for geyser as per OEMs specifications.

3

-

-

... More
Supply Only,Glass Incandescent Electric Water Heater Indicator Lamp, in multi-color caps as per OEMs specifications..

5

-

-

... More
Supply Only,apparatus plate suitable for geyser as per OEMs specifications.

3

-

-

... More
Supply Only,glass wool for insulation purpose suitable for geyser as per OEMs specifications.

2

-

-

... More
Supply Only,brass non return valve,15 mm size suitable for geyser as per OEMs specifications.

2

-

-

... More
Supply Only,stainless steel storage tank suitable for 25 Litres capacity geyser as per OEMs specifications.

1

-

-

... More
Supply Only,stainless steel storage tank suitable for 50 Litres capacity geyser as per OEMs specifications.

1

-

-

... More
Supply Only,600 mm long,PVC Hot/Cold water connections,15mm size,with brass nuts .

2

-

-

... More
Materials and Labour for painting of storage type water heater (geyser) of Capacity 25 Litres complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.etc.,complete all as specified and as directed.

5

-

-

... More
Materials and Labour for painting of storage type water heater (geyser) of Capacity 50 Litres complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust etc. including writing MES No.etc.,complete all as specified and as directed.

5

-

-

... More
Supply and Fix in repair,gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe,15 mm bore, complete all as specified and directed.

2

-

-

... More
Material and labour for 40 mm dia galvanized iron tube medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including all fitting clamps, nut, bolt and washers ,including taking up or down existing steel tubing ,complete all as specified and directed.

90

-

-

... More
Supply and Fix in repair,PVC insulated and FR PVC round sheathed cable with copper conductor (flexible),nominal area of conductor 1.5 sq mm, 3 core, 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable,complete all as specified and directed.

150

-

-

... More
Supply and Fix in repair,PVC insulated and FR PVC round sheathed cable with copper conductor (flexible),nominal area of conductor 4.00 sq mm, 3 core, 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable,complete all as specified and directed.

50

-

-

... More
Supply and Fix in repairs,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed.

5

-

-

... More
S&F for Test Point junction box of suitable size with terminal block, IP 66 weather proof including four hexagonal anticorrisove screws for out door installation including provn of Test points as per IS specifications of shape and size 75x75x25 mm drilled and screwed incl 3 nos 8 mm dia 25 mm long hex head screw, made out of phospher bronze mounted and fixed on box with suitable grouting arrangements Suitable nut bolts, washers of various size as approved, complete duly fixed with ground/earth/roof conductor rigidly complete all as specified.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.