Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Jan 2025
Closing Soon10 Feb 2025
Tender Amount₹ 52,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 63 KVA to 160 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified and directed.

18

-

-

... More
M&L for taking out old unserviceable defective LV bushings on site from outdoor/indoor type distribution transformers of 11/0.433 kV and 200 KVA to 500 kVA and Supply and fix porcelain bushing with heat resistant gasket complete all as specified and directed.

18

-

-

... More
Supply and fix in repairs brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV side 11000 volts grade for 63 KVA to 750 KVA capacity of outdoor/indoor type transformercomplete all as specified and directed.

10

-

-

... More
Supply and fix in repairs brass terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 63 KVA to 160 KVA capacity of outdoor/indoor type transformer complete all as specified and directed.

6

-

-

... More
Supply and fix in repairs brass terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for 200 KVA to 500 KVA capacity of outdoor/indoor type transformer, complete all as specified and directed

6

-

-

... More
M&L for servicing/overhauling, Calibration and decorbonising of 11 kV (panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 630 Amps, indoor type , taking shut down from MRS and disconnecting incoming & out going cables , control cables from VCB and replacement of un-serviceable spares, greasing of revolving assembly in VCB chamber, spring charging mechanism including decorbonising the VCB panel and check servicability all as specified and directed by Engr -in - charge. Note: - (i) : Spare parts/components required for replacement of above shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items. (iii) For item No. 10.00 to 29.00, fixing charge of these items are considered in item No. 9.00

15

-

-

... More
Supply only Feeder protection numerical relay with features of earth fault, phase fault, Over current and fault recording Facility complete all as specified and directed.

5

-

-

... More
Supply only Isolating contact 800A set of 12 Complete all as specified and as directed.

3

-

-

... More
Supply only Vacuum Interrupter Complete all as specified and as directed.

2

-

-

... More
Supply only Closing coil 110VDC Complete all as specified and as directed.

3

-

-

... More
Supply only Triping Coil 110DC Complete all as specified and as directed.

4

-

-

... More
Supply only Master trip relay all as specified and directed.

3

-

-

... More
Supply only digital VAF, PF meter with RS 485 port of accuracy Cl 1 including electical connection all as specified and directed.

3

-

-

... More
Supply only breaker control switches (Trip-neutral-clolse) of rating 25 A VCB Panel Complete all as specified and as directed.

5

-

-

... More
Supply only Indicator lamp 110V DC/240 V AC of colour : green/yellow/red/white/Amber/Blue Complete all as specified and as directed

25

-

-

... More
Supply only Breaker auxillary swtich 6 NO +6NC Complete all as specified and as directed.

3

-

-

... More
Supply only Closing coil box assembly Complete all as specified and as directed.

3

-

-

... More
Supply only Trip coil box Assembly Complete all as specified and as directed.

3

-

-

... More
Supply only Auxillary switch Drive Assembly Complete all as specified and as directed.

3

-

-

... More
Supply only Charging paw Complete all as specified and as directed.

3

-

-

... More
Supply only Buffer for spring all as specified and as directed.

6

-

-

... More
Supply only Epoxy insulator all as specified and as directed.

10

-

-

... More
Supply only Fix R Phase Bus Bar Spout Complete all as specified and as directed.

3

-

-

... More
Supply only Y Phase Bus Bar Spout Complete all as specified and as directed.

3

-

-

... More
Supply only Fix B Phase Bus Bar Spout Complete all as specified and as directed.

3

-

-

... More
Supply only Fix Circuit Spout Complete all as specified and as directed.

1

-

-

... More
Supply and fixing of 110V AC input and 30V DC Power pack source for 11 KV VCB Panel with inbuilt battery including all electrical connection and taking down old unsv one complete all as specified and directed.

2

-

-

... More
Supply only Spring Charging motor with gear assembly complete all as specified and as directed.

2

-

-

... More
Supply only Drive Beam for 11kV VCB complete all as specified and as directed

2

-

-

... More
Supply only Epoxy Body for 11kV VCB complete all as specified and as directed

2

-

-

... More
M& L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed including taking down unserviceable one complete all as specified and directed.

10

-

-

... More
M& L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed incl taking down unserviceable one complete all as specified and directed.

8

-

-

... More
M& L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed incl taking down unserviceable one complete all as specified and directed.

8

-

-

... More
M&L for detecting of fault in 11KV (E) HT cable of any size (within 1-3 km legth) , 3 core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced & Jointing kit shall be measured & paid separately.

4

-

-

... More
S & F gang operated air brake switch mechanically operated on insulator and steel frame, with operating mechanism worked from ground level, with 9 nos insulator tilting type for current rating 200 Amps,11000Volt including taking down old unserviceable one complete all as specified and directed.

10

-

-

... More
S&F Expulsion type drop out fuse with all accessories fixed on HT pole rating 200Amps Amps suitable for 11kV, 3 pole with two Nos insulator per pole including dismantling old unserviceable one complete all as specified and directed.

10

-

-

... More
Supply and fix lightning arrester, expulsion type complete with all fitting distibution class ,discharge capacity 65 Kilo Amp 11000 Volts rating including dismantling old unserviceable lightning arrester complete all as specified and directed.

5

-

-

... More
Supply and fix in repair single phase indoor type current transformer suitable for 11 kV, 50Hz, having effectively earthed neutral system, single core single ratio dry type epoxy resin cast,copper wound primary type,of CT Ratio 100-50/5-5A with rated burden 10VA and accuracy class 1 or better and conforming to IS 2705 (part-I & II) amended upto date with Short Circuit Rating 13.1 kA for 1.0 seconds all as specified and directed.

2

-

-

... More
Supply and fix in repair drawout type three phase indoor type potential transformer with sheet enclosure suitable for 11 kV/110 V, 50Hz, dry type epoxy resin cast type,with rated burden 200VA/Phase and accuracy class 1 or better and conforming to IS 2705 (part-I & II) amended upto date all as specified and directed Engr-in- charge.

2

-

-

... More
Taking out saturated silica gel from existing breather and Supply and replace silica gel in breather of transformers complete all as specified and directed.

20

-

-

... More
Supply and fix in repair silica gel breather 250gm capacity made up of aluminium Top,transparent centre portion made of polycarbonate, filled with silica gel suitable for transformer of capacity 100 KVA to 250 KVA complete all as specified and directed.

10

-

-

... More
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable, etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.

121.5

-

-

... More
Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick for any type of soil all as specified and directed.

93.6

-

-

... More
Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point complete all as specified and directed.

27.9

-

-

... More
Supply and spread clean dry river sand in cable trenches as in cable cushioning complete all as specified and directed.

24.3

-

-

... More
Supply and laying un-reinforced precast concrete cable cover class HV type-1 of flat size 300mmx180mmx40 mm complete in trenches complete all as specified and directed.

1670

-

-

... More
Supply, laying, connecting and testing XLPE HT UG insulated (Earthed) cable laid in trenches/or fixed on pole etc. with screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 95 Sqmm, 3 Core conforming to IS-7098 (Part-II)-1985 laid in trenches/wall/ducts/poles complete all as specified and directed. Notes: (i) Excavation & earth work will be measured and paid separately.

400

-

-

... More
M&L for GI pipe light grade 80mm bore dia with all fittings to be laid in trenches or in floors, complete including taking down rusted one all as speciffied and directed.

20

-

-

... More
M& L for Isolating 11KV HT overhead supply from the substation and earth complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from substation or taking down from 2/4 pole structure ,lifting arrangements, transporting to authorized service centre/work shop for repair and back to the installation after repair including installing, commissioning and testing of the capacity upto 63 KVA complete all as specified and directed.

1

-

-

... More
All as per Serial item No 52.00 above but of 100KVA to 200KVA complete all as specified and directed

2

-

-

... More
All as per Serial item No 52.00 above but of 250KVA to 400KVA complete all as specified and directed

1

-

-

... More
All as per Serial item No 52.00 above but of 500KVA to 750KVA complete all as specified and directed NOTE for ITEM NO. 52.00 to 55.00:- Necessary T&P should be arranged by the contractor. The rate of T&P is included in above quoted rate

1

-

-

... More
Draining out the complete transformer oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer, disconnecting and taking out complete core assembly and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils limbs, refixing of core, core assy,tap changer assy,HT/LT winding connection, terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil including improvement of insulation resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of engr-in-Charge upto 63KVA complete all as specified and directed

1

-

-

... More
All as per Serial item No 56.00 above but of 100KVA to 200KVA

2

-

-

... More
All as per Serial item No 56.00 above but of 250KVA to 400KVA

1

-

-

... More
All as per Serial item No 56.00 above but of 500KVA to 750KVA

1

-

-

... More
Supply only primary (LV side) copper winding coils of existing type size and gauge and in weight complete including wrapping with paper insulation for transformer of 50 kVA to 750 kVA complete all as specified and directed

250

-

-

... More
Supply only primary (HV side) copper winding coils of existing type size and gauge and in weight complete including wrapping with paper insulation for transformer of 63KVA to 750 kVA complete all as specified and directed

220

-

-

... More
Reconditioning of LT coil of copper wound transformer by tuning the old paper insulation straightening the entire LT strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed

120

-

-

... More
Supply and fixing in replacement new off load tap changer assembly complete, making connection and testing complete of the transformer of 50KVA to 200KVA capacity complete all as specified and directed

2

-

-

... More
All as per serial item No 63.00 above but of 250KVA to 400KVA complete all as specified and directed

2

-

-

... More
All as per serial item No 63.00 above but of 500KVA to 750KVA complete all as specified and directed

2

-

-

... More
M&L for replacement brown Rubberized cork sheet gasket of 06mm thick for transformer tank complete all as specified and directed

5

-

-

... More
M&L for Earthing complete with galvanised iron earth plate electrode 600 x 600 x 3mm thick, burried directly in ground vertically to deplth not less than 2.25 metres below ground level with top edge of the plate at a depth of not less than 1.5 metres below the ground level, connected to copper strip of 20 x 3 mm earth lead by means of by means of bolts and nuts, check nuts and washers made of brass, earth strip protected by and including GI pipe 40 mm bore (light grade) and connected to main test point as directed and including concrete pit using PCC (1:3:6) Type C1, precast RCC (1:1:5:3) Type A1 cover slab of size 40 x 40 x 5 cm reinforced with 8 mm dia MS bar @ 150 mm C/C both ways with one handle for lifting, made out of 8 mm dia MS bar embedded in pre-cast cover slab, funnel, wire mesh, 20mm bore galvanised or steel pipe (Light grade) for waterring, charcoal and salt in alternate layers including necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of SRR part I including testing on completion all as specified and directed.

7

-

-

... More
M&L in repair for air break isolating switch 3 insulator for each phase (isolator for 33KV) vertical double stack central rotating type with earth blade hot dip galvanised complete with operating rod and handle complete all as specified and directed.

3

-

-

... More
S & F in repair pre-molded elbow boots for transformer bushing made of non-tracking EPDM rubber suitable of 12kV and 95sqmm 3 core cable complete all as specified and directed.

6

-

-

... More
Supply, install, testing and commissioning of HSV 36 KV single phase outdoor type oil cooled dead tank type CT ration 100-50/5-5 Amp accuracy class 0.5-1 for metering equipment of burden 15 VA as per IS 2705 including connection CT terminal to control panel through control cable and taking down unserviceable one complete all as specifiec and directed.

3

-

-

... More
Supply, install, testing and commissioning of HSV 36 KV single phase outdoor type oil cooled dead tank type PT ratio 33KV/√3 :/110/√3, accuracry class 0.5-1 burden 15 VA as per IS :3156 including connection PT terminal to control panel through control cable and taking down unserviceable one complete all as specified and directed.

3

-

-

... More
M&L for painting of steel tubular HT poles including cross arms, clamps, back plates etc. in situ with one under coat and one finishing coat of aluminium paint after cleaning /preparation of surfaces including making white and black stripes 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No, Substation No, etc. complete all as specified and directed.

20

-

-

... More
M&L for Inspection, testing, servicing and overhauling of Factory Made 11 KV, 630 Amps, SF6 Insulated, Motorized, Outdoor RMU Consisting of any nos Incoming and any nos Outgoing Feeders. Testing comprising of the following all as directed by Eng-in- charge :-Notes: (b) Repair/servicing of spring loaded operating mechanism. (c) Repair/servicing of spring charging motor. (d) Checking, repairing & servicing of gearbox, auxiliary switches, spring, limit switch etc complete. (e) Checking & repairing electrical and mechanical operations (f) Lubrication all moving parts with petroleum jelly & cleaning all bushing insulators with CTC (g) Tightening of all mechanical connections of mechanism (h) Proper Tightening all LV connection of VCB and cable chamber & allied connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, details all as per existing etc. (iii) Major spares will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement.

2

-

-

... More
Supply and fix including dismantling taking out unserviceable existing relay CSDPR-V2-200, CSPR-V5 from RMU of suitable model complete all as specified and directed.

1

-

-

... More
Supply and fix including dismantling taking out unserviceable RM6 Operating Handle Big Size from RMU of suitable make complete all as specified and directed.

1

-

-

... More
M&L for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including complete including one coat of white wash for base foundation of capacity 63 KVA to 750 KVA incoor / outsoor type transformers complete all as specified and directed.

16

-

-

... More
Brick Masonry Foundation / Platform as per IE Rules and of size not less than 2.00 X 2.00 X 1,80m made of brick work using Fly Ash bricks built in Cement Mortar 1:6, over PCC Concrete Bed of 10mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled, 100mm thick PCC 1:2:4 Coping, Type B1, using 20mmgraded stone aggregate over top of the Platform / Foundation, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including necessary earthwork excavation, return filling, removal surplus soil complete all as specified and as directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.