Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Oct 2024
Closing Date6 Nov 2024
Tender Amount₹ 43,60,000
Costs
EMD
₹ 87,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679834_1Bid Award Id
ViewTender No
8445/BOR/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
183.47
-
-
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
15402
-
-
M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
9
-
-
M&L for PCC as in foundation or any other works type C1 (1:3:6) (20mm graded aggregate) all as specified and directed. Note : Any form work required for PCC works are deemed to be included in this rate.
5
-
-
M&L for taking out of old/ unsv cable of any sizes or types for replacement with new one complete all as specified & directed.
2265
-
-
M&L of UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area incl lugs of size 240 sq mm 3.5 core complete all as directed.
Note : i) Necessary excavation, returning and filling shall be measured separately ii) Rate quoted shall be inclusive oif making electrical connection at both end with AL lugs, cable gland and suitable gland and suitable gland as required at site.
iii) On ground Factory test for the quantity more than 100 RM to be carried out by Engineer-in-Charge, JE E/M and the contractor at manufacturer's godown / factory / testing lab situated at OEM's premises in front of OEM's technician / lab engineer and results shall be recorded duly signed by all concerned and the technician / lab engineer. Necessary arrangements for testing shall be made by the contractor. The material shall only be incorporated after getting satisfactory results and the rates quoted is deemed to be included for the above and no extra claim shall be admissible on this account. The test reports with satisfactory results duly signed shall be forwarded alongwith RAR failing which no payment shall be admissible against this item. Thickness of insulation and cables shall be ensured as per IS code by Engr-in-Charge using vernier calipers.
35
-
-
All as per Serial item no.9.00 here-in-above but size 185 sqmm 3.5 core complete all as directed.
150
-
-
All as per Serial item no.9.00 here-in-above but size 150 sqmm 3.5 core complete all as directed.
110
-
-
All as per Serial item no.9.00 here-in-above but size 95 sqmm 3.5 core complete all as directed.
510
-
-
All as per Serial item no.9.00 here-in-above but size 70 sqmm 3.5 core complete all as directed.
60
-
-
All as per Serial item no.9.00 here-in-above but size 25 sqmm 3.5 core complete all as directed.
750
-
-
All as per Serial item no.9.00 here-in-above but size 16 sqmm 4 core complete all as directed.
650
-
-
All as per Serial item no.9.00 here-in-above but size 10 sqmm 2 core complete all as directed.
160
-
-
M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed.
124
-
-
M&L for tubes 80 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed.
30
-
-
All as per Serial item no.18.00 here-in-above but bore size 50 mm complete all as directed.
100
-
-
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 25 - 50 sqmm complete all as specified and directed.
10
-
-
All as per Serial item no. 20.00 here-in-above but size 70-150 sqmm all as specified and directed.
l
6
-
-
All as per Serial item no.20.00 here-in-above but size 185-300 sqmm all as specified and directed.
8
-
-
M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and directed.
4
-
-
All as per Serial item no. 23.00 here-in-above but size 185-240 sqmm all as specified and directed.
2
-
-
Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work should be done by reputed company/ Channel partner like Indo Asian/BCH/L&T/Havells) outdoor type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location : Near Building No - P17
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos BUS BAR:-
(d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 300 Amps capacity, including connection etc complete =01 Set
INCOMING:- (e) Moulded case circuit breaker 160-200 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No
-
-
-
OUTGOING:-
(f) Moulded case circuit breaker 80-100 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No (g) Moulded case circuit breaker 50-63 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 02 No
(h) Moulded case circuit breaker 32-40 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 05 No Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work should be done by reputed company/Channel partner like IndoAsian / BCH / L&T / Havells / Hensel) outdoor type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location :-Near Building P23
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos (d) LCD multifunction meter, Make-ABB/Siemens/Legrand/Schneider-01 No.
BUS BAR:-
(e) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 150 Amps capacity, including connection etc complete =01 Set
INCOMING:- (f) Moulded case circuit breaker 80-100 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No
-
-
-
OUTGOING:-
(g) Moulded case circuit breaker 50-63 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 02 No
(h) Moulded case circuit breaker 32-40 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 03 No Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work should be done by reputed company/ Channel partner like Indo Asian/BCH/L&T/Havells/Hensel) outdoor type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location : Near Building P13
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos BUS BAR:-
(d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 300 Amps capacity, including connection etc complete =01 Set
INCOMING:- (e) Moulded case circuit breaker 160-200 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No
-
-
-
OUTGOING:-
(f) Moulded case circuit breaker 80-100 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 03 No (g) Moulded case circuit breaker 50-63 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No
(h) Moulded case circuit breaker 32-40 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work shoud be done by reputed company/ Channel partner like Indo Asian/BCH/L&T/Havells/Hensel) outdoor type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location : Near Building No - T19
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos BUS BAR:-
(d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 200 Amps capacity, including connection etc complete =01 Set
INCOMING:- (e) Moulded case circuit breaker 100-125 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No
-
-
-
OUTGOING:- (f) Moulded case circuit breaker 80-100 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01No (g).Moulded case circuit breaker 40-50 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 04 No Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT Outdoor cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work shoud be done by reputed company/ Channel partner like IndoAsian BCH / L&T / Havells / Hensel) made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location : Near Building No - P6
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos BUS BAR:-
(d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 150 Amps capacity, including connection etc complete =01 Set
INCOMING:- (e) Moulded case circuit breaker 80-100 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01No
-
-
-
OUTGOING:- (f) Moulded case circuit breaker 40-50 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 05 No (4 Nos Working & 1 No Standby) Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT Outdoor cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work shoud be done by reputed company/ Channel partner like Indo Asian / BCH / L&T/ Havells / Hensel) made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location : Near Building No - P2
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos BUS BAR:-
(d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 400 Amps capacity, including connection etc complete =01 Set
INCOMING:- (e) Moulded case circuit breaker 200-250 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01No
-
-
-
OUTGOING:- (f) Moulded case circuit breaker 80-100 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 06 No (5 Nos Working & 1 No Standby) (g) Moulded case circuit breaker 63-80 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 02 No Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT Outdoor cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work shoud be done by reputed company/Channel partner like Indo Asian / BCH / L&T / Havells / Hensel) made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Location : Near Building No - P29
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos (d) LCD multifunction meter, Make-ABB/Siemens/Legrand/Schneider/L&T-01 No.
BUS BAR:-
(e) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 600 Amps capacity, including connection etc complete =01 Set
INCOMING:- (f) Moulded case circuit breaker 320-400 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01No
-
-
-
OUTGOING:- (g) Moulded case circuit breaker 63-80 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 07 No (6 Nos Working & 1 No Standby) (h) Moulded case circuit breaker 125-160 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No. Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
Supply, install, testing, commissioning LT Outdoor cubicle type distribution panel of suitable size, IP-65 type (metal fabrication and complete assembly work shoud be done by reputed company/ Channel partner like Indo Asian / BCH / L&T / Havells Hensel) made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- Locatin : Near Building No - T1
1
-
-
INDICATING DEVICES:-
(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No
(c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos BUS BAR:-
(d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 250 Amps capacity, including connection etc complete =01 Set
INCOMING:- (e) Moulded case circuit breaker 125-160 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01No
-
-
-
OUTGOING:- (f) Moulded case circuit breaker 63-80 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 02 No (g) Moulded case circuit breaker 32-40 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No. Note- i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.
-
-
-
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth strip 32x6mm size by means of bolls, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering, perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150mm thick all around each plate, test point made out of 40x8mm flat iron galvanised with fixing arrangement, funnel wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate -3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
16
-
-
M & L Galvanised iron strip 32 x 6mm buried in ground all as specified and directed by Engr-in-charge.
80
-
-
M & L for dismantling of ACSR or AAC conductors of any sizes or types etc. complete, setting aside for taking credit and replacement with new cable complete all as specified & directed.
5
-
-
M & L for dismantling of cross arms of M.S.Channels or angle sections etc. complete and depositing to MES store yard for reuse the serviceable steel sections complete all as specified and directed by Engr-in-Charge.
2
-
-
M & L for taking out of old unsv cable of any sizes or types for replacement with new one complete all as specified & directed.
600
-
-
M & L for dismantling of insulators of any type and sizes and depositing to MES store yard for reuse the serviceable insulators complete all as specified and directed by Engr-in-Charge.
390
-
-