Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Jun 2024
Closing Date17 Jul 2024
Tender Amount₹ 49,50,000
Costs
EMD
₹ 99,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_662291_1Bid Award Id
ViewTender No
8963/B/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item No 2 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and as directed.
110
-
-
All as per item serial No 2 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.complete all as specified and as directed.
90
-
-
All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.complete all as specified and as directed.
110
-
-
Materials and Labour forPoint wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Conduit conclead with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and as directed.
150
-
-
All as per item No 7 here-in-before but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables complete all as specified and as directed.
3
-
-
All as per item No 7 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and as directed.
60
-
-
All as per item serial No 7 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.complete all as specified and as directed.
50
-
-
All as per item No 7 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.complete all as specified and as directed.
60
-
-
All as per item No 7 here-in-before but wiring with 4 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 4 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.complete all as specified and as directed.
10
-
-
Supply and fixing switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
540
-
-
Supply and fixing Bell push switch, flush type, 5 Amps 230 volt complete all as specified and as directed.
23
-
-
Supply and fixing socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
110
-
-
Supply and fixing switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
110
-
-
Supply and fixing switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
110
-
-
Supply and fixing ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
450
-
-
Supply and fixing lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and as directed.
40
-
-
Supply and fixing stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
50
-
-
Supply and fixing Ding Dong AC. 230 volts,single pole complete all as directed.
20
-
-
Supply and fixing Bell, AC, 230 volts, single pole complete all as specified and as directed.
20
-
-
S& F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 V complete all as specified and as directed.
13
-
-
Materials and Labour forfor wiring with 2 runs of 1.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 run of 1.5 Sqmm cable and 1 run of 1.5 Sqmm cable along with conduit altogether shall be measured as one unit.
1900
-
-
Materials and Labour forfor wiring with 2 runs of 2.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.
200
-
-
Materials and Labour forfor Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.
200
-
-
Materials and Labour forfor Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.
490
-
-
Supply and fixing in repairs batten type LED light fitting 1x 20W, 220V,AC decorative type with internal SPD upto 4kV and overload voltage protection upto 440V including flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
700
-
-
Supply and fixing in repairs wall mounted decorative luminaire in design mesh suitable for 10W LED lamp B22 base ,including lamp of 10watt .Complete as directed as specified complete all as specified and as directed.
40
-
-
S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and as directed.
50
-
-
Materials and Labour for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I.
83
-
-
Taking down ceiling fans 1400mm /1200mm sweep ,sealing cable end ,dismantling blade & removing the same and refixing on same location or other location of any type/make and size carefully from fan hook, and transporting from any location in side army area to MES E/M store yard and back after repairing complete all as specified and directed.
250
-
-
M & L for painting of ceiling/exhaust fan complete with blades ,in situ with synthetic enamel paint by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed.
200
-
-
Rewinding Ceiling fan by cutting the existing copper winding of ceiling fan 1200/1400 MM capacity and make any type with super enamelled copper wire of suitable size incl all insulating materials varnishing and neating complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and directed.
120
-
-
Rewinding Ceiling fan by cutting the existing copper winding of ceiling fan Heavy Duty old model 1200/1400 MM capacity and make any type with super enamelled copper wire of suitable size incl all insulating materials varnishing and neating complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed.
40
-
-
Supply and fixing in repairs fan bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as directed.Make : NBC/SKF/SBBI)
160
-
-
Supply only rubber reels incl shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and directed
10
-
-
Supply only down rod made of 15mm dia GI pipe heavy duty 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and directed.
10
-
-
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and directed.
20
-
-
Taking down exhaust fan of size 200mm to 400mm sweep of any make and refixing on same location or other location carefully from site & transporting from any location inside Army area to MES E/M store yard for stripping of fan washing thoroughly of bearing/bush by petrol, washing fan blade body etc thoroughly provision of new greasing replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same incl provn of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of EIC complete all as directed.
Note :- (i) Defective/unserviceable parts replaced will be paid separately in respective item of Sch 'A' as Supply only. (ii) The cost of taking down unserviceable parts included in this item.
60
-
-
Rewinding the armature for 200mm to 400mm sweep exhaust fan any make with super enamelled copper wire of suitable size with and including all insulating materials varnishing complete all as specified and directed.
50
-
-
Supply and fixing in repairs ball bearing of size suitable for exhaust/wall fan upto 400 mm sweep complete all as specified and as directed. (Make : NBC/SKF/SBBI)
20
-
-
Supply and fixing in repairs for capacitor ISI marked 230/240/250 volts AC 4 MFD suitable for exhaust fan incl condenser spacer and soldering of condenser wire to fan wire and fixing complete all as specified and as directed.
30
-
-
Supply and fixing in repair of unsv switch piano, flush type single pole one way 5 Amps 230 voltcomplete all as specified and as directed.
325
-
-
Supply and fixing in repair of unsv switch flush type 15 Amp single pole one way.complete all as specified and as directed.
30
-
-
Supply and fixing in repair/ replacement of unsv socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
100
-
-
Supply and fixing in repair of unsv switch socket combination outlet 2-in-1, 5 Amp flush type complete all as directed.
250
-
-
Supply and fixing in repair/ replacement of unsvr switch socket combination multipurpose, 2 in 1, 3 pin, 5 & 15 Amp flush type complete all as directed.
200
-
-
Supply and fixing in repair/ replacement of unsv socket outlet 3 Pin 15 Amp 240 volts .complete all as specified and as directed.
40
-
-
Supply and fixing in repair of unsv ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
30
-
-
Supply and fixing in repair of unsv lamp holder insulated PVC/Polycarbonate/bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and as directed.
30
-
-
Supply and fixing in repair of unsv stepped type electronic fan regulator, flush type complete all as specified and as directed.
60
-
-
Supply and fixing in repair of unsv fan capcitor 2.5 Mfd suitable for 1200/1400mm sweep ceiling fan complete all as specified and as directed.
500
-
-
Supply and fixing in repair for factory made, sheet steel distribution boards, TPN, 4 Way, double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-0 using 12.5 mm graded stone aggregate complete all as specified and as directed.
20
-
-
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 8 way with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-0 using 12.5 mm graded stone aggregate complete all as specified and as directed.
20
-
-
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 4 way with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-0 using 12.5 mm graded stone aggregate complete all as specified and as directed.
5
-
-
Supply fix in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-0 using 12.5 mm graded stone aggregate.complete all as specified and as directed.
10
-
-
Supply and fixing in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA complete all as specified and as directed.
210
-
-
Supply and fixing in repair MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed.
25
-
-
Supply and fixing in repair MCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and as directed.
20
-
-
Supply and fixing in repair for MCCBs 415 V, 16 KA, four pole, 63 Amps complete all as specified and as directed.
5
-
-
Supply and fixing in repair for MCCBs 415 V, 16 KA, four pole, 100 Amps complete all as specified and as directed.
5
-
-
Supply and fix in repair modular fan regulator,120 W, 2 module.complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular switch 1 way 6 amp, 1 module complete all as specified and as directed.
30
-
-
Supply and fixing in repair modular switch 1 way 16 amp, 1 module.complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular switch 2 way 6 amp, 1 module complete all as specified and as directed.
5
-
-
Supply and fixing in repair modular socket, 6 Amp 2/3 pin combined, 2 module complete all as specified and as directed.
30
-
-
Supply and fixing in repair modular socket, 16 Amp 2/3 pin combined, 2 module complete all as specified and as directed.
20
-
-
Supply and fixing in repair modular Bell push 6A, 1 module complete all as specified and as directed.
15
-
-
Supply and fixing in repair modular white cover plate with frame, 1 module complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular white cover plate with frame, 2 module complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular white cover plate with frame, 3 module complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular white cover plate with frame, 4 module complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular white cover plate with frame, 6 module complete all as specified and as directed.
10
-
-
Supply and fixing in repair modular white cover plate with frame, 8 module complete all as specified and as directed.
10
-
-
Supply and fixing in repair metal flush box 1/2 module for modular switches complete all as specified and as directed.
10
-
-
Supply and fixing in repair metal flush box 3 module for modular switches complete all as specified and as directed.
10
-
-
Supply and fixing in repair metal flush box 4 module for modular switches complete all as specified and as directed.
10
-
-
Supply and fixing in repair metal flush box 6 module for modular switches complete all as specified and as directed.
10
-
-
Supply and fixing in repair metal flush box 8 module for modular switches complete all as specified and as directed.
10
-
-
Dressing of pre-wired casing caping/PVC conduit by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit ,screws etc) complete all as specified and directed.
50
-
-
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
10
-
-
Supply and fixing in repairs 18 watt LED recessed/surface mounted luminaire with high brightness LED for glare-free homogenous illumination suitable for Armstrong/grid ceiling and fixture size in mm (LxWxH) 295x295x70 complete all as specified and as directed.
10
-
-
Supply and fixing in repair LED building security light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI70 ,PF 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose complete all as specified and as directed.
155
-
-
Materials and Labour for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
155
-
-
Supply and fixing in repair LED 40/45 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and as directed.
2
-
-
Supply and fixing in repair LED surface/recess mounted round downlighter 12 W with pressure die-cast sink and PC difuser in chrome finish diffuser with integrated driver, complete all as specified and as directed.
2
-
-
Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of pre-connected MCBs by changing screw of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box after completion supply power complete all as specified and as directed.
2
-
-
S & F in repair PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep for mounting switches.complete all as specified and as directed.
125
-
-
Materials and Labour forEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
20
-
-