Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 99,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_655156_1Bid Award Id
ViewTender No
8613/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF TPS WAITING AREA NEAR BLDG NO T-53 ASC, SPECIAL REPAIR TO BLDG NO. OWT-597 OWT-598, PROVN OF BATHING POINT AND WASHING POINT FOR OR EME AND PROVN OF 05 X AC FOR METRO EDGE ROUTER AT LIKABALI MIL STN UNDER GE 872 EWS
BOQ Items
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
57.9
-
-
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed.
18
-
-
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
6.3
-
-
M & L for plain Cement Concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in post, walls, retaining walls, ballast walls and the likes any thickness, above top of footings including attached pilasters and buttreses complete all as specified and directed.
3.7
-
-
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified and directed.
1.65
-
-
M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
42.6
-
-
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.
14.5
-
-
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
58
-
-
M & L Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
(Note : Reinforcement will be measured & paid seperately)
1
-
-
M & L for Reinforced Cement Concrete M-25 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
7.1
-
-
S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
480
-
-
S & F high strength Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
240
-
-
M & L for 40 mm thick, Cement Concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) Damp proof course to horizontal or vertical surfaces including necessary form work mixed with and including water proofing compound as per manufacturer's instructions complete all as specified and directed.
6
-
-
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed.
4250
-
-
S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed.
265
-
-
S & F Mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long complete all as specified and directed.
15
-
-
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
340
-
-
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
26
-
-
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
70
-
-
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
120
-
-
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
10
-
-
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
120
-
-
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
70
-
-
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
215
-
-
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
115.8
-
-
M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
13.85
-
-
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
835
-
-
M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
245
-
-
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
305
-
-
M & L for Machine cut kota stone slab flooring 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing over and including 15 mm thick, screed bed in cement mortar 1:6 complete all as specified and directed.
200
-
-
M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed.
47.1
-
-
Spreading and levelling in layers n.exc 25 cm thick and well ramming including watering complete all as specified and directed.
5.3
-
-
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
45
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish complete all as specified and directed.
60
-
-
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, and set & jointed in neat cement slurry and 3mm wide joints shall be maintained with spacers which is to be filled with epoxy grout using masking tape and the masking tape is to removed after filling the epoxy grout including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
105
-
-
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, and set & jointed in neat cement slurry and 3mm wide joints shall be maintained with spacers which is to be filled with epoxy grout using masking tape and the masking tape is to removed after filling the epoxy grout including 10 mm thick bedding in cement mortor 1:4 complete all as specified and directed.
185
-
-
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish complete all as directed by the Engr-in-Charge
0.45
-
-
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed.
80
-
-
Demolition of brick work or stone / boulder masonry/ precast concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish complete all as directed by the Engr-in-Charge.
4
-
-
M & L for Providing Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls in width and setting in mortar 1:6 complete all as specified and directed.
125
-
-
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed
25
-
-
M & L for Preparation of old treated surfaces of asbestos/plastered of ceiling over 10 cm girth or width not otherwise described after complete removal of existing treatment and painting with two coats of synthetic enamel paint over a coat of alkali resistant primer complete all as specified and directed.
268
-
-
S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
4.1
-
-
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
200
-
-
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
17
-
-
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed.
25
-
-
S & F 75 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
51
-
-
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
34
-
-
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
34
-
-
S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed.
14
-
-
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
14
-
-
S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
15
-
-
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
4
-
-
S & F in repair 15 mm bore, angular stop valve, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
4
-
-
S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
14
-
-
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
35
-
-
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
30
-
-
Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 59 above)
5
-
-
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
20
-
-
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
41
-
-
Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 62 above)
4
-
-
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
2
-
-
S & F in repairs, 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
2
-
-
S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
2
-
-
Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
30
-
-
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
20
-
-
S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
10
-
-
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
36
-
-
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
4
-
-
S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
6
-
-
S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
4
-
-
S & F 75 mm bore, PVC (SWR) vent cowl complete all as specified and directed.
17
-
-
Surface dressing n.exc 15 cm deep as in soft/loose soil complete all as specified and directed.
70
-
-
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
7
-
-
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
2
-
-
M & L for Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
2.5
-
-
M & L for Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
1.5
-
-
M & L for 75 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
45
-
-
S & F Vitreous China White Wash Hand Basin of Size 450x300mm, with Pedastal, Flat Back, oval type including Brass Chromium plated Waste Fitting 32mm bore (dia) and PVC Waste Pipe 32mm bore (dia) of Low or High density, a Pair of Cast Iron Brackets or Erecting Stand duly Painted, Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 but excluding Taps, Chain, Plug & Porocelain Stopper complete all as specified and as directed.
4
-
-
S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
4
-
-
S & F 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed.
4
-
-
S & F 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
4
-
-
S & F 125 mm size, shower rose, brass chromium plated, swival type, complete all as specified and directed.
4
-
-
S & F 15 mm bore, angular stop cock, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
4
-
-
S & F 15 mm bore, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
2
-
-
S & F 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
4
-
-
S & F Soap dish, Vitreous china white, approximate size 160mm x 160mm x 90mm, embedded in walls/fixed to plugs with chromium plated brass screws complete all as specified and directed.
4
-
-
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position as specified in SSR Part I and directed.
1
-
-
S & F 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
1
-
-
S & F 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
3
-
-
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
40
-
-
S & F 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
4
-
-
S & F Towel Rack 600mm long with Lower Hangers, Chromium plated including Chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed. (Make: Jaquar Cat No. ACN1181S or equivelant of make as per list of manufacturer's)
10
-
-
S & F Mild steel screw bolts of 16 to 20 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n.exc 30cm long complete all as specified and directed.
10
-
-
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
21
-
-
Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
2
-
-
M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
68
-
-
All as per item No. 100 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
2
-
-
All as per item No. 100 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
14
-
-
All as per item No. 100 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
14
-
-
S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
70
-
-
S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
17
-
-
S & F LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
8
-
-
S & F LED Bulb, 7 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
23
-
-
S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havell's cat part No. DHDNSHODAW04 or equivalent make as per List of Manufacturer's)
2
-
-
S & F MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)
3
-
-
S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
16
-
-
S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed.
2
-
-
S & F Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
14
-
-
S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.
14
-
-
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
47
-
-
S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
17
-
-
S & F 2x2 recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
14
-
-
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casin capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.
(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin capping shall be measured as one length)
237
-
-
S & F energy efficient, low noise, ceiling fan, 1200 sweep, BEE 5 Star Rated with BLDC motor, copper wound conforming to IS-374-2019, ISI marked, suitable for operation on single phase, 240 Volts AC, 50 Hz of approved colour including fan regulator, electronic type, down rod, canopies, 3 Nos blades, shackles, safety rope, hanging clamp, bushes and having power factor 0.94, service value 6.5, power consumption less than 35 Watts, air delivery 215cmm, THD less than 5% with speed control by electronic regulator including connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years onsite replacement manufacturer's warranty)
10
-
-
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)
2
-
-
S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
1
-
-
Supply and laying cable PVC insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of size 25 Sqmm 2 core including taking out old one complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
130
-
-
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
1
-
-
S & F sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240V, C-curve, Double pole complete all as specified and as directed.
5
-
-
Supply, install, testing & Commissioning, Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built ioniser and plasma filter for better indoor quality with minimum 3 Star Rating and EER 3.2 of capacity 2 TR complete with all connecting pipes and fixing accessories such as bracket etc complete all as specified and directed.
5
-
-
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed.
5
-
-
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.
(Note: Thickness after punning down shall be measured for payment)
18.7
-
-
Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed.
1610
-
-
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, LT electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor conforming to IS-7098 (Part-I) 1988 of size 16 Sqmm 2 core including connecting by using suitable size of aluminium thimbles, connectors, cable glands, bolts, nuts etc complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
287
-
-
S & F 40 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors as in protection pipe complete all as specified and directed.
18
-
-
Supply, Install, Commissioning and testing LT cubical type feeder pillar box, CPRI approved factory made, outdoor type, of size 0.6m (L) x 0.3m (W) x 0.5mm (H) made out of 3.15mm thick CRCA sheet, with angle iron 20x20x3mm frame work, totally enclosed with canopy, Dust and vermin proof, weather proof with double hinge door shutter in front and back with necessary locking arragnement, mounted on stand of height 0.6m from ground level made of MS angle iron of size 25x25x3mm grouted in PCC1:2:4, Type B-1 foundation of suitable size with 415 Volts, 3 pahse, 4 wire, AC 50 Cycles per second having copper bus bar of capacity 200 Amps (TPN) with colour sleeve (02 Nos) insulated with suitable size of PVC copper conductor thimbles, glands for connections mounted on porcelain insulator complete all as specified and directed.
1
-
-