Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Sep 2024
Closing Date19 Oct 2024
Tender Amount₹ 51,00,000
Costs
EMD
₹ 1,01,500Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674708_1Bid Award Id
ViewTender No
8812/NAR/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed by Engineer-in-charge at site.
4
-
-
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-charge at site.
400
-
-
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar, complete all as specified and as directed by Engineer-in-charge at site.
73
-
-
M&L for factory made, rubber moulded, vibratory Machine pressed precast cement concrete coloured, interlocking paver block, any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and no pigment laid over and including 30 mm thick sand for base, complete, all as specified and as directed by Engineer-in-charge at site.
290
-
-
M&L for rubber moulded chequered cement concrete coloured tiles of size 30cm X 30cm X 25 mm thick with grey cement and pigment set jointed and pointed in neat cement slurry, laid over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 as in floors complete, all as specified and as directed by Engineer-in-charge at site.
250
-
-
M&L 20-25 mm thick machine cut kota stone slab flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing, laid over and including 20 mm thick cement screed in CM 1:6, complete all as specified and as directed by Engineer-in-charge at site.
150
-
-
All as per BOQ item No 9.00 above but on vertical surface, including rubbing and hand polishing to achieve mirror finish, laid over and including 15 mm thick rendering in CM 1:4 with wire marking to receive tile over it, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
M&L for 20mm thick granite (of any type as approved by Engineer-in-charge), work in cooking platform, in toilets for fixing wash hand basin, counter slab (table rubbed and polished), in steps, jambs, pillars, window cills and like, fixed in cement mortar 1:4 including pointing in white cement 1:2 using granite / marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement screed in CM 1:6, complete all as specified and as directed by Engineer-in-charge at site.
6
-
-
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 10 mm thick rendering in CM 1:3 finished even and fair with wire markings to receive granite over it, complete all as specified and as directed by Engineer-in-charge at site.
4
-
-
Demolition of old defective cement concrete (un-reinforced), in ground floors and pavings n. exc 15cm thickness (below or above ground lever) and removing the debris away from site, complete all as specified and as directed by Engineer-in-charge at site.
25
-
-
M&L for 75mm thick cement concrete type C2, 1:3:6 (40mm graded stone aggregate) as in path, plinth protection, finished even and smooth, complete all as specified and as directed by Engineer-in-charge at site.
80
-
-
M & L cement concrete type E2, 1:5:10 (using 40 mm graded aggregate) as in foundations, filling and mass concrete, sub-base complete, all as specified and as directed by Engineer-in-charge at site.
3
-
-
M&L 100mm thick cement concrete, type B-2, 1:2:4 (using (40 mm graded aggregates) as in flooring, finished even and fair (without using extra cement), including necessary use and waste of formwork / screed strips and to divide the area in panels, including finishing exposed edges fair or rounding or chamfering of exposed edges complete, all as specified and as directed by Engineer-in-charge at site.
120
-
-
M & L 50mm thick cement concrete, type B1, 1:2:4 (20 mm graded aggregates) as in sub floors, finished even and smooth using extra cement, including necessary use and waste of formwork / screed strips and to divide the area in panels, including finishing exposed edges fair or rounding or chamfering of exposed edges complete, all as specified and as directed by Engineer-in-charge at site.
80
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge at site.
515
-
-
M&L for Non Skid joint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4, complete all as specified and as directed by Engineer-in-charge at site.
200
-
-
M&L for Non Skid joint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4, complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
M&L for Glazed ceramic coloured tiles, 7 to 8mm thick, area of tile exceeding 0.11 and n.exc 0.18 Sqm, in vertical surface such as skirting, dados, risers to steps, etc., set and jointed in neat cement slurry and pointed in white or colour cement to match colour of tile, laid over and including 10mm thick rendering as backing coat in CM 1:3 with wire markings to receive tile over it, complete all as specified and as directed by Engineer-in-charge at site.
20
-
-
M&L for Non Skid joint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4, complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
M&L for Non Skid joint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in vertical surface such as skirting, dados, risers to steps, etc., set and jointed in neat cement slurry and pointed in white or colour cement to match colour of tile, laid over and including 10mm thick rendering as backing coat in CM 1:3 with wire markings to receive tile over it, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
M&L for dark shade vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tile, laid over and including 15mm thick screed bed in CM 1:4, complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
M&L for dark shade vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in vertical surface such as skirting, dados, risers to steps, etc., set and jointed in neat cement slurry and pointed in white or colour cement to match colour of tile, laid over and including 10mm thick rendering as backing coat in CM 1:3 with wire markings to receive tile over it, complete all as specified and as directed by Engineer-in-charge at site.
20
-
-
M&L for Coloured / Printed Glazed ceramic coloured tiles, 7 to 8mm thick, area of tile exceeding 0.11 and n.exc 0.18 Sqm, in vertical surface such as skirting, dados, risers to steps, etc., set and jointed in neat cement slurry and pointed in white or colour cement to match colour of tile, laid over and including 10mm thick rendering as backing coat in CM 1:3 with wire markings to receive tile over it, complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
Taking up or down steel tubing and connections, bore of pipes 15 mm and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
60
-
-
Taking up or down steel tubing and connections, bore of pipes 20 mm and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
Taking up or down steel tubing and connections, bore of pipes 25 mm and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S&F galvanised iron tubing, with screwed socket joints, medium grade, with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required, cutting through walls, floors, etc. and their making good and fixed complete to wall and ceilings or laid in floors, suitable for bore of pipes 15 mm, complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
S&F galvanised iron tubing, with screwed socket joints, medium grade, with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required, cutting through walls, floors, etc. and their making good and fixed complete to wall and ceilings or laid in floors, suitable for bore of pipes 20 mm, complete all as specified and as directed by Engineer-in-charge at site.
90
-
-
S&F galvanised iron tubing, with screwed socket joints, medium grade, with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required, cutting through walls, floors, etc. and their making good and fixed complete to wall and ceilings or laid in floors, suitable for bore of pipes 25 mm, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
M&L for Refixing old steel tubing, obtained from BOQ ITEM No 27.00 above, in new or old position (Walls, ceiling, floors, trenches etc.), with screwed socket joints, with all NEW tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required, cutting through walls, floors, etc. and their making good and fixed complete to wall and ceilings or laid in floors, suitable for bore of pipes 15 mm, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
M&L for Refixing old steel tubing, obtained from BOQ ITEM No 28.00 above, in new or old position (Walls, ceiling, floors, trenches etc.), with screwed socket joints, with all NEW tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required, cutting through walls, floors, etc. and their making good and fixed complete to wall and ceilings or laid in floors, suitable for bore of pipes 20 mm, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S&F IN REPAIRS, Vitreous China Wash Hand Basin, size 550 X 400 mm (Flat Back or Angle Back type) including cutting for and pinning in ends of brackets; with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed; including PVC connections of length 600mm and 15mm dia size with PTMT nuts; and a pair of angle iron brackets duly painted / erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3, complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F IN REPAIRS, Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and as directed by Engineer-in-charge at site.
20
-
-
S&F IN REPAIRS, Angular stop valves / stop valve, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, suitable for bore of pipe 15 mm, complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F IN REPAIRS, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 Ltrs including taking down old unservicable tank of any description and in any position and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
4
-
-
S&F IN REPAIRS, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltrs including taking down old unservicable tank of any description and in any position and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
12
-
-
S&F IN REPAIRS, PVC waste pipe, 32mm dia, 60 cm long for WHB / urinal, complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
S&F IN REPAIRS, PVC connections of length 450mm, 15 mm size with PTMT nuts complete all as specified and as directed by Engineer-in-charge at site.
35
-
-
S & F IN REPAIRS, wall mixer with and including over head shower with 115 mm long bend pipe on upper side, connecting legs and wall flanges complete all as specified and as directed by Engineer-in-charge at site.
3
-
-
S&F Ball Valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe and fixed, (Minimum weight 210gms) suitable for bore of pipe 20mm, complete all as specified and as directed by Engineer-in-charge at site.
16
-
-
S&F IN REPAIRS, Ball Valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe and fixed, (Minimum weight 210gms) suitable for bore of pipe 20mm, complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F IN REPAIRS, Ball Valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe and fixed, (Minimum weight 455gms) suitable for bore of pipe 25mm, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S & F IN REPAIRS, 600mm x 450mm, bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F IN REPAIRS, PVC valveless, syphonic action type flushing cistern, 10 Ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets, and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and as directed by Engineer-in-charge at site.
14
-
-
S&F IN REPAIRS, grating doom 100 mm dia of PTMT, (Minimum weight 25 gms), complete all as specified and as directed by Engineer-in-charge at site.
20
-
-
S&F IN REPAIRS, bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, suitable for 75 / 110 mm Internal dia of pipe complete, all as specified and as directed by Engineer-in-charge at site.
130
-
-
S&F PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
S&F PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and as directed by Engineer-in-charge at site.
5
-
-
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S&F IN REPAIRS, vitreous china urinal, half stall type (flat back), of size 635mm x 395mm x 420mm, white, with grating and union for discharge pipe (excluding flushing cistern) but including 32mm dia PTMT coupling and waste pipe, providing and fixing plugs, bedding urinal against wall in CM 1:2, complete all as specified and as directed by Engineer-in-charge at site.
8
-
-
S&F IN REPAIRS, vitreous china urinal, bowl type, of size 465mm x55mm x 265 mm, white, with grating and union for discharge pipe (excluding flushing cistern) but including 32mm dia PTMT coupling and waste pipe, providing and fixing plugs, bedding urinal against wall in CM 1:2, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S & F IN REPAIRS, Urinal spreader of PTMT, any colour, suitable for fixing to 15 mm dia pipe (Minimum weight 60gms), complete all as specified and as directed by Engineer-in-charge at site.
18
-
-
S&F, IN REPAIRS, vitreous china wash down water closet of "Orissa" pattern size 580 x 440 mm white with integral foot rests including removing filled lean concrete from sunken portion and putting of lean concrete after treatment of sunken slab, connection to trap, flushing cistern and to flushing pipe etc. complete and making good to floor, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S&F IN REPAIRS, vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap white, including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor, complete all as specified and as directed by Engineer-in-charge at site.
4
-
-
S&F IN REPAIRS, plastic water closet seat cover, white, closed pattern with flat bottom & cover and aluminium anodised hinging device and fixed to WC pan, complete all as specified and as directed by Engineer-in-charge at site.
4
-
-
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge at site.
14
-
-
M&L for brick work with sub class "B" bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engineer-in-charge at site.
13
-
-
M&L for Brick work with subclass 'B' bricks, straight or curved on plan, exceeding 6 m mean radius, built in Cement Mortar 1:6, BUT USING BRICKS OBTAINED FROM BOQ ITEM NO 63 ABOVE, complete all as specified and as directed by Engineer-in-charge at site.
1
-
-
Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed by Engineer-in-charge at site.
380
-
-
M&L for 15mm thick rendering on other than fair faces of brick wall in CM 1:6 finished even and smooth with out using extra cement complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
M&L for rendering 15mm thick (external) in CM 1:4, mixed with WPC @3% by the weight of cement, on fair faces of brick / concrete surfaces, finished even and smooth without using exta cement, complete all as specified and as directed by Engineer-in-charge at site. NOTE:- WPC shall be measured and paid seperately.
200
-
-
M&L for 5mm thick rendering on fair faces of concrete surfaces of ceiling, in CM 1:3, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge at site.
80
-
-
M&L for preparing new plastered surfaces of walls and applying two coats of weather coat exterior Paint over a coat of primer with approved tint as per manufacturer's instructions, complete all as specified and as directed by Engineer-in-charge at site.
170
-
-
M&L for preparing of newly plastered wall surface and applying two coats of cement base paint over a coat of cement wash complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
M&L for preparation of new plastered surfaces , applying white cement based wall care putty on the surfaces with minimum 1 mm uniform thickness making surface absolutely smooth by grinding with sand paper and applying two coats of oil emulsion distemper over a coat chalk whiting of approved shade on old surface of wall complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge at site.
80
-
-
M&L for preparing of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of white wash on old surfaces of wall complete all as specified and as directed by Engineer-in-charge at site.
300
-
-
M&L for preparation of old distempered surfaces of wall including cornices etc. by washing, rubbing down, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and stopping of distempered surfaces and applying one coat of oil emulsion distemper of approved shade complete all as specified and as directed by Engineer-in-charge at site.
1500
-
-
M&L for complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down and applying a layer 1 mm thick wall care putty for making the surface even & smooth etc. complete all as specified and as directed by Engineer-in-charge at site.
200
-
-
M&L for preparing old decorated plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coats of exterior emulsion paint (Apex/Weather coat) white or tinted as approved complete all as specified and as directed by Engineer-in-charge at site.
2000
-
-
M&L for preparation of old painted surfaces of wood and wood based materials by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and as directed by Engineer-in-charge at site.
120
-
-
M&L for preparation of old painted surface of steel and iron by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and as directed by Engineer-in-charge at site.
100
-
-
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of Cement Base Paint white or tinted of approved shade complete all as specified and as directed by Engineer-in-charge at site.
1000
-
-
Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m each and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
Taking down old defective chowkhats with shutter (without taking off shutters from the frame) exc 1.5 sqm but n.exc 4 sq.m each and removing away from site, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
Taking down old defective shutters of any description (wooden or aluminium) n. exc 1.0 sq.m each and refixing the same wooden or aluminium door shutters in the same opening after taking down, easing and adjusting including refixing builders hardware, glass etc as required and renewal of unserviceable builders hardware, glass, screws complete, complete all as specified and as directed by Engineer-in-charge at site. NOTE:- Cost for new builders hardware, glass, screws against unserviceable builders hardware, glass, screws is included in the rate quoted for this item.
10
-
-
Taking down old defective shutters of any description (wooden or aluminium) exc 1.0 sq.m but n. exc 2.0 sq.m each and refixing the same wooden or aluminium door shutters in the same opening after taking down, easing and adjusting including refixing builders hardware, glass etc as required and renewal of unserviceable builders hardware, glass, screws, complete all as specified and as directed by Engineer-in-charge at site.
NOTE:- Cost for new builders hardware, glass, screws against unserviceable builders hardware, glass, screws is included in the rate quoted for this item.
15
-
-
S&F 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed by Engineer-in-charge at site.
0.5
-
-
S&F pressed steel frames for doors of size 125mm x 60mm with one or more rebates, including necessary fixing lugs, hinges, lock strike plate, complete all as specified and as directed by Engineer-in-charge at site.
NOTE:- Filling hollow of frame with plain cement concrete and/or with cement mortar shall be measured and paid separately.
60
-
-
S&F pressed steel frames for doors of size 105mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and as directed by Engineer-in-charge at site.
NOTE:- Filling hollow of frame with plain cement concrete and/or with cement mortar shall be measured and paid separately.
100
-
-
M&L for Plain Cement Concrete M-15 (Nominal Mix) using 12.5 mm graded stone aggegate as in filling of hollow portion of pressed steel frames complete all as specified and as directed by Engineer-in-charge at site.
1.2
-
-
S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with with and including 5mm thick teakwood lipping all round, complete all as specified and as directed by Engineer-in-charge at site.
60
-
-
M & L for providing, cement concrete type C1, 1:3:6 (using 20 mm graded aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, bed blocks, kerbs not provided for in Item 04028 of SSR Part II 2020, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork complete all as specified and as directed by Engineer-in-charge at site.
0.5
-
-
M&L mild steel work as in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, hooks (stay) heavy for large gates, hooks and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-charge at site.
2
-
-
S&F 35mm thick, 2nd class hard wood, Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed by Engineer-in-charge at site.
40
-
-
S&F 35mm thick, 2nd class hard wood, Glazed and skeleton window shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b)sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-charge at site.
80
-
-
S&F IN REPAIRS, steel windows, with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
S&F IN REPAIRS, steel ventilator with top hung shutter with or without glazing bar, including hinges, fixing lugs, steel peg stay, complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
S&F IN REPAIRS, steel ventilator with top hung shutter with or without glazing bar, including hinges, fixing lugs, steel peg stay, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification complete all as specified and as directed by Engineer-in-charge at site.
50
-
-
S/F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engineer-in-charge at site.
15
-
-
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators and partition, with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer-in-charge at site.
40
-
-
M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainlesssteel screws, all complete as per architectural drawings and all as specified and as directed by Engineer-in-charge at site.
90
-
-
M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and all as specified and as directed by Engineer-in-charge at site. NOTE:- Fittings shall be measured and paid separately under respective items in this BOQ.
85
-
-
M&L for preparation of new or previously untreated surfaces of wood and wood based materials of any description not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primer, complete, all as specified and as directed by Engineer-in-charge at site.
150
-
-
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat red oxide zinc chrome primer, complete, all as specified and as directed by Engineer-in-charge at site.
150
-
-
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or beads when fixed in joinery, complete all as specified and as directed by Engineer-in-charge at site.
60
-
-
S&F IN REPAIRS, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or beads when fixed in joinery, complete all as specified and as directed by Engineer-in-charge at site.
95
-
-
M&L for 18/19mm thick, Block boards grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in cup board shutters / shelves, partitions and pelmets etc, fixed with screw/nails including 4mm thick teak wood lipping complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
M & L for 12mm thick, Block boards grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work as in cup board shutters / shelves, partitions and pelmets etc, fixed with screw/nails including 4mm thick teak wood lipping complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames including taking out old wooden beads complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
M&L for 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 sq. m in each pan, complete all as specified and as directed by Engineer-in-charge at site.
120
-
-
M&L for 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 sq. m in each pan, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
M&L for 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge at site.
10
-
-
S&F IN REPAIRS, floor door stopper overall length of cover plate 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
S&F 300mm long MS sliding door bolts , plate type, stove enameled black , with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts ,four on bolt plate and two on staple plate, and fixed, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
S&F Mild steel butt hinges, cold rolled, medium weight, of size 100mm, and fixed complete all as specified and as directed by Engineer-in-charge at site.
80
-
-
S&F Mild steel pressed handles, oval type, stove enamelled black, and fixed, size of handle 150 mm complete all as specified and as directed by Engineer-in-charge at site.
80
-
-
S&F Mild steel barrel tower bolts stove enamelled black, with bright bolt and fixed, length of bolt 200 mm long complete all as specified and as directed by Engineer-in-charge at site.
60
-
-
S&F IN REPAIRS, 300mm long MS sliding door bolts , plate type, stove enameled black , with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts ,four on bolt plate and two on staple plate, and fixed, complete all as specified and as directed by Engineer-in-charge at site.
20
-
-
S&F IN REPAIRS, 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
S&F IN REPAIRS, Mild steel butt hinges, cold rolled, medium weight, of size 100mm, and fixed complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
S&F IN REPAIRS, Extruded aluminium alloy handles, fabricated type, anodised, size of handle 150 mm, complete all as specified and as directed by Engineer-in-charge at site.
25
-
-
S&F IN REPAIRS, Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 200 mm, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 150 mm, complete all as specified and as directed by Engineer-in-charge at site.
20
-
-
S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, of size 100mm complete all as specified and as directed by Engineer-in-charge at site.
40
-
-
S&F Extruded aluminium alloy handles, fabricated type, anodised, size of handle 100mm, complete all as specified and as directed by Engineer-in-charge at site.
30
-
-
Dismantling wall and ceiling boards or insulation boards or in cupboards, any thickness, any description, including cover fillets complete all as specified and as directed by Engineer-in-charge at site.
130
-
-
S&F IN REPAIRS, suspended false ceiling using E-gnd 2430 180 GSM (exposed ceiling suspension system) of gnd size 600 mm x 600 mm with main runner 32 mm x 24 mm and wall angle 24 mm x 24 mm using 4 mm thick Hihg pressure steam crude Everest Non asbestor fiber cement plain board (E board classic) in & including a grn of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin form the roof with adjustment clip providing positions for light fixture air conditioning diffuser and ducts sprinkler smoke cetectores etc. the main runners to be secured to structura soffts by hanger @ 1220 mm maximum centre to centre the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjucent wall flush fitting 1220 mm cross tee to be inter locked between main runners @ 610 mm centre to centre so as to form 600 mm x 600 mm grid complete all as specified and as directed by Engineer -in-charge at site.
100
-
-
S&F IN REPAIRS, 4 mm thick, Non Asbestos, Fiber Cement plain Board, fixed in ceiling, complete all as specified and as directed by Engineer -in-charge at site.
30
-
-
S&F IN REPAIRS, Waste coupling of PTMT (half or full threaded), (Minimum weight 45gms), suitable for bore dia of pipe 32mm, complete all as specified and as directed by Engineer -in-charge at site.
10
-
-
S&F IN REPAIRS, Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engineer -in-charge at site.
8
-
-
S&F IN REPAIRS, aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and as directed by Engineer -in-charge at site.
Make:- Sandhu / Samrat)
8
-
-
S&F IN REPAIRS, double action floor spring hydraulically regulated made up of aluminium alloy sheet foundation box with stainless steel cover fixed to Aluminium doors complete all as specified and as directed by Engineer -in-charge at site. Make:- Sandhu/Samrat
6
-
-
S&F IN REPAIRS, Aluminium Lock, 4 Lever, 100mm long fixed to Aluminum doors complete all as specified and as directed by Engineer -in-charge at site. Make:- Godrej / Link
4
-
-
M&L for repairs to aluminium doors or windows, not exceeding 3.0 Sqm each, including necessary replacement or provision of required jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, locking arrangement, pintle hinges etc., complete all as specified and as directed by Engineer -in-charge at site.
27
-
-