Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date9 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 65,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 34,17,820.80 inserted by the MES in Schedule ‘A’ Part-II.

1

-

-

... More
INTERNAL WATER SUPPLY (Sch 'A' PART-III)

-

-

-

... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 22,77,103.59 inserted by the MES in Schedule ‘A’ Part-III.

1

-

-

... More
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,24,76,529.83 inserted by the MES in Schedule ‘A’ Part-IV.

1

-

-

... More
ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V)

-

-

-

... More
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,39,81,282.79 inserted by the MES in Schedule ‘A’ Part-V.

1

-

-

... More
SEWAGE DISPOSAL (Sch 'A' PART-VI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 16,49,512.42 inserted by the MES in Schedule ‘A’ Part-VI.

1

-

-

... More
AREA DRAINAGE (Sch 'A' Part-VII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 37,38,620.80 inserted by the MES in Schedule ‘A’ Part-VII.

1

-

-

... More
EXTERNAL WATER SUPPLY (Sch 'A' Part-VIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,77,736.13 inserted by the MES in Schedule ‘A’ Part-VIII.

1

-

-

... More
EXTERNAL ELECTRIFICATION (Sch 'A' PART-IX)

-

-

-

... More
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 97,35,389.64 inserted by the MES in Schedule ‘A’ Part-IX.

1

-

-

... More
FIRE FIGHTING (Sch 'A' Part-X)

-

-

-

... More
Lump sum price worked out by the Contractor for “(FIRE FIGHTING)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 24,05,902.40 inserted by the MES in Schedule ‘A’ Part-X.

1

-

-

... More
STP (Sch 'A' Part-XI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(STP)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 10,33,667.83 inserted by the MES in Schedule ‘A’ Part-XI.

1

-

-

... More
LIGHTNING PROTECTION & DG SET (Sch 'A' Part-XII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION AND DG SET) ” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,72,300.00 inserted by the MES in Schedule ‘A’ Part-XII.

1

-

-

... More
LIFT (Sch 'A' Part-XIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 70,23,321.44 inserted by the MES in Schedule ‘A’ Part-XIII.

1

-

-

... More
BOREWELL (Sch 'A' Part-XIV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(BOREWELL)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,57,494.91 inserted by the MES in Schedule ‘A’ Part-XIV.

1

-

-

... More
COOLING APPLIANCES (Sch 'A' Part-XV)

-

-

-

... More
Lump sum price worked out by the Contractor for “(COOLING APPLIANCES)” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 16,85,248.33 inserted by the MES in Schedule ‘A’ Part-XV.

1

-

-

... More
CHAIN LINK FENCING (Sch 'A' Part-XVI)

-

-

-

... More
Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING)” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,68,565.91 inserted by the MES in Schedule ‘A’ Part-XVI.

1

-

-

... More
HOT WATER SUPPLY (Sch 'A' Part-XVII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(HOT WATER SUPPLY)” as listed in Schedule ‘A’ Part-XVII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,01,376.12 inserted by the MES in Schedule ‘A’ Part-XVII.

1

-

-

... More
DEMOLITION AND DISMANTLING (Sch 'A' Part-XVIII)

-

-

-

... More
Lump sum price worked out by the Contractor for “(DEMOLITION AND DISMANTLING)” as listed in Schedule ‘A’ Part-XVIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,29,594.90 inserted by the MES in Schedule ‘A’ Part-XVIII.

1

-

-

... More
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XIX)

-

-

-

... More
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT Grubbing up tree trunk including cutting of trunk portion protruding over ground, of dia exc 300cm, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed.

6

-

-

... More
INTERNAL WATER SUPPLY S & F 15 mm bore, chromium plated, fancy type wall mixer for mixing Hot & Cold water screwed down for iron/PP-R pipe including telephonic shower with CP flexible pipe and fixed complete all as specified and as directed.

8

-

-

... More
S & F 15 mm bore, chromium plated, soap dish and fixed to plugs with CP brass screwed complete all as specified and as directed.

150

-

-

... More
S & F chromium plated, health faucet shower with CP flexible pipe of 15mm bore (ABS body) with 1m long easy flex tube in Crom finished complete all as specified and as directed.

38

-

-

... More
S & F chromium plated, cap hanger (hook) having 4 nos hook fixed to plate, scewed to wall complete all as specified and as directed.

96

-

-

... More
INTERNAL ELECTRIFICATION S & F modular type 3/5 pin socket outlet incl plug top 16A controlled by switch 16A including sheet metal enclosure suitable for Geyser point complete all as specified and directed.

7

-

-

... More
S & F Modular type TV socket Co-axial outlet 1 Module in the modular MS / flush metal GI Box and cover plate including concealed 25mm PVC conduit in wall/ceiling/fixed to roof , connections etc complete all as specified and directed

16

-

-

... More
S & F Modular type RJ-11 telephone socket outlet in the modular MS/GI sheet box and cover plate including concealed 25 mm PVC conduit in wall/ceiling/fixed to roof , connections etc complete all as specified and directed

36

-

-

... More
S & F 3-star (EEL) LED lamp 5W capable to output 525 lm , 6500K suitable base B22 with lamp holder B22 type complete all as specified and directed.

451

-

-

... More
S & F LED Bollard (Garden light) of capacity 9W , 5700K with opal acrylic diffuser and IP66 protection complete including connecting up with three core twisted flexible copper conductor cable complete all as specified and directed.

10

-

-

... More
S & F LED Post Top (Gate light) of capacity 25W , 5700K made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP65 protection including connecting up with three core twisted flexible copper conductor cable complete all as specified and directed.

4

-

-

... More
S & F Decorative wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED Lamp B22 base with LED lamp of 9W, 950 lm, 6500K including connecting up with three core twisted flexible copper conductor cable with complete all as specified and directed.

14

-

-

... More
S & F TPN DB 4 way (Vertical type) , double door, metallic distribution board, conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO /MCCB as incomer and SP/TPN MCBs as outgoing, reversible metal door, 125 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.

3

-

-

... More
S & F SPN DB with sheet metal enclosure 240 volts, 6 way, double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and directed.

1

-

-

... More
S & F MCCB 63 Amp, 4 pole , 16 KA, 415V Thermal & fixed magnetic adjustable with SS enclosure complete all as specified and directed.

3

-

-

... More
S & F MCB SP of 240 Volts, AC, 50 Hz of capacity 63 Amps 10 KA, 'C' curve complete all as specified and directed.

9

-

-

... More
SEWAGE DISPOSAL Supply, install and testing of LLDPE septic tank conventional type designe with top cover suitable for 10 users (approx size 2000 litre) with and including necessary excavation and earthworks, 150mm thick PCC 1:4:8 type D2 for beding, haunching and packing, making pipeline for inlet/outlet/vent pipe, returning filling and removing of surplus soil at a distance not less than 50m from site complete all as specified and directed.

1

-

-

... More
M&L for construction of Sokage wells excavation in any type of soil, foundation in PCC (1:3:6) walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM 1:4, 15mm thick rendering in CM 1:4, RCC cover slab in M25 cover, interconnecting pipes of RCC with proper haunching, benching in cement concrete 1:2:4 type B1, completed filled with bricks bats, size of well 1.0m internal dia and 1.50 m effective depth complete all as specified and directed.

1

-

-

... More
LIGHTNING PROTECTION Supply and fix Lightning conductor advance early streamer emission technology stainless steel body 1 mtr length complete all as specified and directed.

4

-

-

... More
OBSTRUCTION LIGHT Supply and fix Aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete including standard fixing arrangements all as specified and directed.

4

-

-

... More
S&F PVC sheathed copper conductor cable of size 3 core 2.5 sqmm multi stranded conductor laid in ground/fixed to wall roof etc with suitable calmps spacers bolts nuts etc complete all as specified and directed.

100

-

-

... More
Supply and fix Astronomical time switches 250 V single Phase of 40 Amp rating with 32A TP contactor fitted inside steel enclosure max load 6KW complete all as specified and directed.

4

-

-

... More
EXTERNAL WATER SUPPLY Supply, jointing and laying in trenches in standard lenght, centrifugally cast (spun) ductile iron (Dl) pressure pipes, S/S type, 200 mm dia with inside cement mortar lining and black bitumen external coating, nominal daimeter, class K-7 classification, confirming to IS-8329 (ISI marked), including push on and rubber gasket joints and jointing including testing complete all as specified and directed.

300

-

-

... More
Supply, jointing and laying in trenches in standard lenght, centrifugally cast (spun) ductile iron (Dl) pressure pipes, S/S type, 100 mm dia with inside cement mortar lining and black bitumen external coating, nominal daimeter, class K-7 classification, confirming to IS-8329 (ISI marked), including push on and rubber gasket joints and jointing including testing complete all as specified and directed.

1500

-

-

... More
Supply and fix automatic air release valve 50 mm dia suitable for domestic water with gun metal stop valve complete all as specified and directed.

2

-

-

... More
Supply and fix automatic air release valve 80 mm dia suitable for domestic water with gun metal stop valve complete all as specified and directed.

2

-

-

... More
M&L for construction of valve pit of internal size 120 cm x 120 cm x 100 cm with one brick thick brick masonary wall in cement mortar (1:4) PCC foundation 15 cm thick (1:4:8) type D-2 with 15 cm offsets, PCC copping 5 cm thick (1:2:4) type B-1, plastering 15 mm thick in cement mortar (1:4), 40x40x6mm angle iron frame and 3mm thick MS sheet cover with locking arrangement including painting to steel surfaces wtih two coats of synthetic arrangement including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation and earth work complete all as specified and directed.

3

-

-

... More
M&L for construction of valve pit of internal size 90 cm x 90 cm x 60 cm with one brick thick brick masonary wall in cement mortar (1:4) PCC foundation 15 cm thick (1:4:8) type D-2 with 15 cm offsets, PCC copping 5 cm thick (1:2:4) type B-1, plastering 15 mm thick in cement mortar (1:4), 40x40x6mm angle iron frame and 3mm thick MS sheet cover with locking arrangement including painting to steel surfaces wtih two coats of synthetic arrangement including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation and earth work complete all as specified and directed.

9

-

-

... More
M&L for DI fittings for DI pipe flange/ spigot and socket of size 80 mm to 350 mm bore such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars caps and plugs complete all as specified and directed.

700

-

-

... More
EXTERNAL ELECTRIFICATION Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 400 Amp indoor type complete all as specified and directed.

1

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box ( Main LT panel 01 ) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 2000 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (Main Sub Station Panel S/S Panel to be located at proposed substation Bldg No. 07 ) Item Contined as Ser No. 19.32

1

-

-

... More
INCOMING : a) ACB 1000 Amps 4 pole 50 Hz manual draw out type with microprocessor release - 01 No OUTGOING : (a) MCCB 4 Pole 250 Amps, 415 Volt, 50 Hz, thermal magnetic adjustable rupturing capacity 36 KA -01 Nos (b) MCCB 4 Pole 125 Amps, 415 Volt, 50 Hz, thermal magnetic adjustable rupturing capacity 35 KA -02 Nos (c) MCCB 4 Pole 100 Amps, 415 Volt, 50 Hz, thermal magnetic adjustable rupturing capacity 35 KA -04 Nos (d) MCCB 4 Pole 25 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -01 Nos (e) Multifunctional meter (KWH, V,A,PF,KVA,KVAR, and Maximum demand KW)-01 Nos (f) LED indication lamp RYB-03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box (Panel 8) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 200 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 8 for Officers Mess, Loc Near Bldg No 05) Item Contined as Ser No. 19.34

1

-

-

... More
INCOMING : (a) MCCB 100 Amps 4 pole 50 Hz thermal magnetic adjustable rupturing capacity 25 KA - 01 No OUTGOING : (a) MCCB 4 Pole 32 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -03 Nos (b) MCCB 4 Pole 25 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -01 Nos (c) MCCB 4 Pole 16 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -01 Nos (d) Multifunctional meter (KWH, V,A,PF,KVA,KVAR, and Maximum demand KW)-01 Nos (e) LED indication lamp RYB - 03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box (LT Panel 2) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 200 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 2 For Water Supply Pump House) Item Contined as Ser No. 19.36

1

-

-

... More
INCOMING : (a) MCCB 100 Amps 4 pole 50 Hz thermal magnetic adjustable rupturing capacity 35 KA - 01 No OUTGOING : (a) MCCB 4 Pole 32 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -02 Nos (b) MCCB 4 Pole 25 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -01 Nos (c) MCCB 4 Pole 20 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -01 Nos (d) MCCB 4 Pole 16 Amps, 415 Volt, 50 Hz, Fixed thermal and fixed magnetic, rupturing capacity 10 KA -02 Nos (e) DOL Starter 7.5 HP - 03 Nos (f)DOL Starter 12.5 HP-03 Nos (g) Fully automatic Submersible Sterter -15 HP - 01 No (h) Dosing motor Starter -03 Nos (j) Multifunctional meter (KWH, V,A,PF,KVA,KVAR, and Maximum demand KW)-01 Nos (k) LED indication lamp RYB - 03 Nos (l) LED indication lamp RYB - 03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box (Panel 7) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 200 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 7 for Adm Bldg) Item Contined as Ser No. 19.38

1

-

-

... More
INCOMING : (a) MCCB 100 Amps 4 pole 50 Hz adjustable thermal and fixed magnetic rupturing capacity 35 KA - 01 No OUTGOING : (a) MCCB 4 Pole 40 Amps, 415 Volt, 50 Hz, adjustable thermal & Fixed magnetic, rupturing capacity 25 KA -03 Nos (b) MCCB 4 Pole 16 Amps, 415 Volt, 50 Hz, Fixed thermal and fixed magnetic, rupturing capacity 10 KA -02 Nos (c) Time switch 20 Amp with contactor - 03 Nos (d) Multifunctional meter (KWH, V,A,PF,KVA,KVAR, and Maximum demand KW)-01 Nos (e) LED indication lamp RYB-03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box (Panel 6) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 100 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 6 for JCO mess Club) Item Contined as Ser No. 19.40

1

-

-

... More
INCOMING : (a) MCCB 25 Amps 4 pole 50 Hz adjustable thermal and fixed magnetic rupturing capacity 25KA - 01 No OUTGOING : (a) MCCB 4 Pole 16 Amps, 415 Volt, 50 Hz, Fixed thermal and fixed magnetic, rupturing capacity 10 KA -03 Nos (b) Time switch 20 Amp with contactor - 02 Nos (c) Multifunctional meter (KWH, V, A, PF, KVA, KVAR, and Maximum demand KW)-01 Nos (d) LED indication lamp RYB - 03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box (Panel 4) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 500 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 4 for HAV and OR`s Single living accn, G+3 Bldg) Item Contined as Ser No. 19.42

1

-

-

... More
INCOMING : (a) MCCB 250 Amps 4 pole 50 Hz thermal magnetic adjustable rupturing capacity 36 KA - 01 No OUTGOING : (a) MCCB 4 Pole 32 Amps, 415 Volt, 50 Hz, adjustable thermal and fixed magnetic rupturing capacity 25 KA -8 Nos (b) Multifunctional meter (KWH, V, A, PF, KVA, KVAR and Maximum demand KW)-01 Nos (c) LED indication lamp RYB-03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box (Panel 5) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 200 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 5 after existing 30 KVA DG set AMF for lift, fire pump and perimeter lights) Item Contined as Ser No. 19.44

1

-

-

... More
INCOMING : (a) MCCB 4 Pole 100 Amps, 415 Volt, 50 Hz, thermal magnetic adjustable rupturing capacity 35 KA -01 Nos OUTGOING : (a) MCCB 4 Pole 16 Amps, 415 Volt, 50 Hz, fixed thermal and fixed magnetic rupturing capacity 10 KA -10 Nos (b) Time switch 20 Amp with contactor - 05 Nos (c) Multifunctional meter (KWH, V, A, PF, KVA, KVAR and Maximum demand KW)-01 Nos (d) LED indication lamp RYB-03 Nos

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder pillar box ( Panel 3 ) outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, CPRI type tested factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 100 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accommodate the following items including supply and fix following items complete all as specified and directed :- (LT Panel No 3 for Dinning/Cook/Kitchen) Item Contined as Ser No. 19.46

1

-

-

... More
INCOMING : (a) MCCB 125 Amps 4 pole 50 Hz adjustable thermal and fixed magnetic rupturing capacity 36 KA - 01 No OUTGOING : (a) MCCB 4 Pole 32 Amps, 415 Volt, 50 Hz, adjustable thermal and fixed magnetic rupturing capacity 25 KA -02 Nos (b) MCCB 4 Pole 16 Amps, 415 Volt, 50 Hz, adjustable thermal and fixed magnetic rupturing capacity 25 KA -04 Nos (c) Multifunctional meter (KWH, V, A, PF, KVA, KVAR and Maximum demand KW)-01 Nos (d) LED indication lamp RYB-03 Nos

-

-

-

... More
Supply & installation, testing and commissioning of Galvanized steel High mast lighting system of 16 meter in two section, 3 mm section thickness, top dia 150 mm, bottom dia 360 mm, capable to withstand wind pressure upto 180 KMPH, orientation symmetric with non flame proof winch motor, movable lantern carriage double drum winch with 6mm 316 grade SS hoisting ropes of 7/19 construction , trailing cable -01 per high mast ( 5 core 2.5 sqmm), lighting finial , anchore plate & template, foundation bolts, double washers nuts, LED aviation light - 01 set, lightning arrester- 01 Nos with 02 Nos GI plate earthing , Feeder panel - 01 No with 02 Nos GI plate earthing, power supply cable from LT feeder pillar box to High mast and its accessories plug and socket, wiring cable fo fixture , flexible conduit , copper lug , PVC tape cable tie etc . System is suitable for loading 08 nos 80 to 150w LED lights incl suitable RCC foundation as recommended by OEM complete all as specified and directed.

3

-

-

... More
Supply and fix Cone LED bollard 08 Watts complete for garden lighting complete all as specified and as directed.

26

-

-

... More
M&L for street light bracket made out of 32 mm dia GI pipe light grade 1.2 mtr long cut to size and to shape, fixing to steel tubular swaged LT poles with flat iron clamps of size 40X6mm 02 sets incl nuts, bolts and washers incl two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.

80

-

-

... More
S&F LT/HT cable path indicators of oval shaped size 200mmX150mmX6mm thick made out of moulded cast iron and embrosing LT/HT UG cable and fixed on MS angle iron 25X25X5mm thick 40 cm in length with two nos nuts , bolts and washers, including two coats of synthetic enameled paint over a coat of Zinc coat primer on exposed surface,angle iron to be fixed into the ground incl necessary earth work and foundation with PCC 1:3:6 type C1 complete all as specified and directed.

250

-

-

... More
Supply and fix junction box made out of polycarbonate with IP 55/1P 66 protection of suitable size including - 04 Nos cable terminal, 02. Nos polycarbonate cable gland, 01 Nos DIN rail and 01 No. MCB SP. 10 KA 6 Amps incl 01 pair of clamp made out of MS flat 25 X 3 mm, nuts bolts and washers incl painting of clamps and nuts, bolts and washers with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.

90

-

-

... More
M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 100 mm bore dia for passing of UG cable complete all as specified and directed. NOTE: GI Pipe will be measured and paid separately.

80

-

-

... More
DG SET Supply, installation, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set water cooled for power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, 62.5 KVA (50 KW or next nearest higher capacity) at 0.8 power factor complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy complied with CPCB Norms etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genset including OEM in built fitted AMF panel with the following under-mentioned features complete all as specified and directed :- ( DG set for water supply Pump House) a) Alphanumeric LCD display with LED backlight b) Operator interface. c) Suitable to provide a record of most recent fault conditions & fault history. d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA, frequency etc. e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. f) Control including provn of service adjustment & calibration of DG control functions. (A) Genset shall have followings Specifications : Prime mover Rating : 62.5 KVA/50 KW No of Phase : 03 Power Factor: 0.8 (LAG) Item Contined as Ser No. 19.53 to 19.55

1

-

-

... More
(B) Engine Specification : Cooling : Water cooled Aspriation : Turbo Charged after cooled RPM : 1500 Governer : Mechanical (C) Alternator specifications : Voltage : 415 Volt RPM / Frequency : 1500 / 50 HZ Enclosure : IP 23 Voltage regulation (Max) : +/- 1 % Insulation class : H Class (D) Make of Engine : Cummins/ Kiloskar green/ Ashoka Leyland (E) Make of Alternator : Stamford/ Kirloskar. Make of Battery : Exide/AMCO. (F) Size/type/Number of battery : As per manufacturere (OEM) recommendations. (G) OEM manufacutured Inbuilt type AMF Panel with suitable size MCCB - 02 Nos ( DG incomming and Main Incomming), heavy duty 3 Pole contractor, Auto Manual switch, Digitial Amper Meter & Volt meter- 02 Sets (for DC battery current and AC for Mains), 3 Phase Indicators, CT`s, Suitable rating aluminium bus bar complete.

-

-

-

... More
Note:- (i) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates. (ii) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. (iii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipment’s, resistive load including POL shall be made available by the contractor. are to be included. (iv) The quoted rate shall be deemed to be inclusive of the PCC foundation required for placing the DG set and it should be as per the manufacturers recommendation. (v) Contractor shall submit the specification of DG set and take prior take approval from GE before procurement of DG set. (vi) Contractor shall produce the plateform drg form OEM and take approval of GE. (vii) Contractor shall produce all test certifacte and Purchase voucher before claming the payment. (viii) AMF panel shall be inbult type as per OEM specification.

-

-

-

... More
Supply, installation, testing, and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set water cooled for power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, 30 KVA (24 KW or next nearest higher capacity) at 0.8 power factor complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canopy complied with CPCB Norms etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genset including OEM in built fitted AMF panel with the following under-mentioned features complete all as specified and directed :-(DG Set for 70 KLD STP) a) Alphanumeric LCD display with LED backlight b) Operator interface. c) Suitable to provide a record of most recent fault conditions & fault history. d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA, frequency etc. e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. f) Control including provn of service adjustment & calibration of DG control functions. (A) Genset shall have followings Specifications : Prime mover Rating : 30 KVA/24 KW No of Phase : 03 Power Factor: 0.8 (LAG) Item Contined as Ser No. 19.56 to 19.58

1

-

-

... More
(B) Engine Specification : Cooling : Water cooled Aspiration : Turbo Charged after cooled RPM : 1500 Governor : Mechanical (C) Alternator specifications : Voltage : 415 Volt RPM / Frequency : 1500 / 50 HZ Enclosure : IP 23 Voltage regulation (Max) : +/- 1 % Insulation class : H Class (D) Make of Engine : Cummins/ Kiloskar green/ Ashoka Leyland (E) Make of Alternator : Stamford/ Kirloskar. Make of Battery : Exide/AMCO. (F) Size/type/Number of battery : As per manufacturer (OEM) recommendations. (G) OEM manufactured Inbuilt type AMF Panel with suitable size MCCB - 02 Nos ( DG incoming and Main Incoming), heavy duty 3 Pole contractor, Auto Manual switch, Digital Ampere Meter & Volt meter- 02 Sets (for DC battery current and AC for Mains), 3 Phase Indicators, CT`s, Suitable rating aluminium bus bar complete.

-

-

-

... More
Note:- (i) Anything missed out in the technical specifications but technically required for efficient working of DG Set is deemed to be included in the quoted rates. (ii) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. (iii) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer; all testing arrangements / equipment’s, resistive load including POL shall be made available by the contractor. are to be included. (iv) The quoted rate shall be deemed to be inclusive of the PCC foundation required for placing the DG set and it should be as per the manufacturers recommendation. (v) Contractor shall submit the specification of DG set and take prior take approval from GE before procurement of DG set. (vi) Contractor shall produce the platform drg form OEM and take approval of GE. (vii) Contractor shall produce all test certificate and Purchase voucher before clamming the payment. (viii) AMF panel shall be inbuilt type as per OEM specification.

-

-

-

... More
BOREWELL M&L for Drilling trial bore hole by reverse circulation method/direct rotary method in any type of soil, including rocks complete all as specified in IS 2800 for 250mm dia upto 180m depth complete all as specified and directed. Note : Contractor shall carry out log test during drilling of bore and report for the same to be submitted to GE.

180

-

-

... More
M & L for Enlargement and development from ground level to 60m depth of the same trial bore by drilling by reverse rotary circulation method / direct rotary method from dia 250mm to 675mm complete all as specified and directed. Note : Casing pipe, slotted pipe, pea gravel and fittings shall be measured and paid separately.

60

-

-

... More
M & L for Enlargement and development from depth exceeding 60m but not exceeding 180m of the same trial bore by drilling by reverse rotary circulation method / direct rotary method from dia 250mm to 525mm complete all as specified and directed. Note : (i) Casing pipe, slotted pipe, pea gravel and fittings shall be measured & paid separately. (ii) In case additional developing of trial bore is required due to site condition beyond 180mtrs, the same will be measured and paid for under this item.

120

-

-

... More
Supply, welding and lowering in position 200mm (internal bore) ERW MS casing pipe (Conferming IS:4270-2001) of wall thickness not less than 7 mm, pipe with plain ended collar welded in suitable lengths complete all as specified and directed. Note : Before lowering of MS casing pipe in bore, pipes to be jointed with one another at site by welding process. All necessary arragment of welding to done at site by contractor and cost for same to be included in unit rates. No extra charge will paid by department.

60

-

-

... More
Supply, welding and lowering in position 150mm (internal bore) ERW MS casing pipe (Conferming IS:4270-2001) of wall thickness not less than 7.00 mm , pipe with plain ended collar welded in suitable lengths complete all as specified and directed. Note : Before lowering of MS casing pipe in bore, pipes to be jointed with one another at site by welding process. All necessary arragment of welding to done at site by contractor and cost for same to be included in unit rates. No extra charge will paid by department.

84

-

-

... More
S&F MS reducing socket size 200 x 150 mm not less than 6mm thick complete all as specified and directed. Note :- All necessary welding arrangement to be done by the contractor for jointing reducer socket with MS casing pipe at site.

1

-

-

... More
M & L for performing yield test for the bore well by continuously pumping for 16 hrs to determine safe pumping yield complete all as specified and directed. Note:- (1) Alignment (vertically) Test and Step down test shall be carried out in the bore well constructed and result submitted to GE.

1

-

-

... More
Supply, lowering wire cage type stainer LCG confirming to IS - 8110, 150 mm dia of slots 0.75 mm thickness, 4.95 mm wall thickness 7 mm and welde4de with MS pipe and heavy duty collar and welded centre guide MS flat iron 20X6 mm complete all as specified and directed.

36

-

-

... More
Supplying and placing pea gravel packing (gravel size 3mm to 8mm) through out annular space of the tube well assembly complete all as specified and directed.

22

-

-

... More
S&F Top cap for (350mm) bore with 8mm thick MS plate for tube well complete all as specified and directed.

1

-

-

... More
Developing tube well with contractor's own compressor of suitable capacity under his own arrangement with required plants & equipments, tools & sockets till sand/mud free water for potable quality is obtained minimum upto 72hrs & after developing, tesitng of yield incl draw down test, vertically test & required performance test complete all as specified and directed.

72

-

-

... More
Supply, lowering, testing and commissioning of 20 HP Submersible pump having brass impeller and sufficient stage to suit the discharge capacitiy 800 LPM & 30 m head with outer dia of pump shall not be more than 150 mm & directly coupled with water cooled AC 3 phase 50 HZ, 440 volts electric motor complete all as specified and directed. Note : (i) The submersible pump set should be guaranteed for all defects for 01 year. In case of burn out within one year the same shall be replaced with new motor complete all as specified and directed.(ii) Slection of pump discharge to be finilised base on yield test report of bore.Before procurement of pump contractor has to submit the specification of submersible pump and make and take approval of GE. However the head of pump should not be less than 30 m. HP of pump shall be calculated according to pump discharge and head.(iii) Submersible pump shall have brass impeller and sufficient stage to suit the required head of 30 mtrs and outer dia of pump shall not be more than 150mm.

1

-

-

... More
M&L for steel wire rope 10mm dia with clamps of suitable size securing the submersible pump motor complete all as specified and directed.

75

-

-

... More
Supply and fixing PVC insulated & PVC sheathed Submersible flate cable 6 Sqmm x 3 core copper conductor 1100 volt grade, ISI Marked, confirming to IS:694/2010 complete all as specified and directed.

120

-

-

... More
Supply, fixing, testing & commissioning submersible pump starter in sheet metal enclouser, type MU-G, fully automatic, Star Delta Starter suitable for 20 HP / 15KW Submersible Pump set, 3P, 415 V, 50 Hz, with max relay range 28-42 Amp, Dry run protection, with over load, single phase and phase reversal protection with on / off switch, indicator and Voltage & Amp indication complete including fixing of starter at location as directed by Enginner- In -charge including making all necessary connections of cable from source & submersible pump complete all as specified and directed.

1

-

-

... More
Supplying welding and lowering bail plug having not less than 3.00 mtrs long and (250mm) bore dia MS ERW pipe having wall thickness 6 mm including 2 coats of black bituminous paint over a coat of red zinc oxide primer complete all as specified and directed.

1

-

-

... More
COOLING APPLIANCES Supply and fix Refrigerator of capacity 310 Ltrs electric driven (single phase), BEE 3 star rated complete all as specified and directed.

7

-

-

... More
S&F 1.5 KVA Electronic type Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V to 280V with output voltage stabilized at 230 V with accuracy of ± 2.0%, current carrying capacity suitable for water cooler/refrigerator/Deep freezer complete all as specified and directed.

38

-

-

... More
FIRE FIGHTING Supply and fix hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe, nozzle, coupling etc of MS sheet of Thickness 2.0 mm complete all as specified and directed.

32

-

-

... More
Supply and fix automatic air release valve 100mm dia suitable for domestic water with 100 mm gun metal stop valve complete all as specified and directed.

8

-

-

... More
Factory made and CPRI tested outdoor type wall mounted on wall brackets. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-65 class protection and fabricated out of 3 mm CRCA sheet duly powder coated after nine tank process. The panel shall be front openable type adequate space all around cessories such as LT switchgear and metering instruments including internal wiring in the panel with FRLS non flamable insulated multi stranded/ solid copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories complete all as specified and directed. Panel shall be mounted on 40x40x6mm angle iron frame and painted with fire red colour. Item Contined as Ser No. 19.80

2

-

-

... More
(i) INCOMING (a) MCCB 415 Volts, 40 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 16 kA 1 Nos. (b) Digital multi function meter (V,A,Hz,Pf) with and including resin cast CTs - 01 Set. (c) Phase indicating lamp(set of 3). (II) OUTGOING (a) MCCB 415 Volts, 32 Amp, rating 4 Pole, (Service Breaking Capacity 10 kA)- 03 Nos.(01 stand by) (b) Star delta starter suitable upto 15 Hp fire pump set-02 No (as per pump capcity) (b) Internal wiring of panel with stranded copper cable of suitable size (c) LED indicating lamp(Set of three)-01 Set (d) All standard relays and contactors to make the motor and pump operational in auto, manual and test mode to meet the pressure of 3.5 Kg per cm2 at terrace level. An auxulary switch to start the motor from desired location to test the motor and pressure from ground floor shaft. Control cables from Pressure switch to control panel, From control panel to Auxilary switch (FRLS armoured) and power cable from control panel to motor. Note: Scope of work also includes un foreseen items such as laying / passing of cable through walls/ floors/ pipes over/ beneath the surface, drilling holes core cutting etc are deemed to be included in unit quoted rate.

-

-

-

... More
Supply and fix Fire Extinguisher Dry chemical powder (ABC) type light weight stored pressure type, 6 kg capacity complete all as specified and directed.

20

-

-

... More
Supply and fix Fire Extinguisher water type light weight store pressure type 9 Ltr cap complete all as specified and directed.

16

-

-

... More
Supply and fix Fire Extinguisher mechanical foam type light weight stored pressure type 9 ltr cap complete all as specified and directed.

4

-

-

... More
Supply and fix Fire Extinguisher CO2 type (light weight squeezed grip type) 4.5 Kg cap complete all as specified and directed.

4

-

-

... More
Supply and fix Fire Extinguisher wet chemical based stored pressure type 6 Ltrs cap complete all as specified and directed.

2

-

-

... More
Supply and fix Fire Extinguisher mechanical foam AR AFFF based 9 Ltrs cap complete all as specified and directed.

3

-

-

... More
Supply and fix Fire Extinguisher clean agent type 6 Ltrs cap complete all as specified and directed.

4

-

-

... More
STP & WTP Design, Supply, construction, installation, testing & commissioning of Package type Sewage Treatment Plant 70 KLD Capacity comprising of the following items complete all as specified and directed:- (i). Fine Bar Screen(Mesh) - 01 No MOC: MSEP/SS304 Fine Screen Mesh size 06mm Manual Type (ii) O & G Trap MOC: of Tank : Brick work / RCC Manual Type (iii) Grit removal Mechanism MOC:: MSEP Size : 250 lit (iv) Raw Collection Pump - 01 No (1W+1S) Type :Non clog sewage submersible Make: Lubi/ KDS pump/ Kirloskar/ Equivallent Head: 10m Flow : 3.5 m3/hr (v) Air Blower - 02 Nos (1W+1S) Type : Twin Lobe Root Type Both side oil cooling Suction at Top and Discharge at Bottom Capacity : 50 m3/hr Pressure : 0.4kg/cm2 Item Contined as Ser No. 19.88 to 19.93

1

-

-

... More
(vi) Air Piping - 01 Lot Non submerged piping: MS/GI/uPVC Submerged piping : uPVC Make of UPVC: Kishan/Astral/Supreme/Finolex Make of MS/GI : Standard available. (vii) Liquid Piping - 01 Lot Non submerged piping: uPVC - Sch - 40 Submerged piping : uPVC - Sch-40 Make : Waterflo/ Astral/ Supreme/ Kishan/ Equav (viii) Control Panel - 01 No Type of Panel : Automatic panel of micro controller base HMI Size :7 Housing: MS with powder coating with minimum 1.6mm sheet Cable Entry : Bottom Incoming Voltage & Amp should show in HMI Mode of operation ; Automatic/Manual All working + Standby equipment will be change over automatic in case trip on equipment as well as cascade in operation. Blowers with VFD with auto operation of DO meter. All Motor should show individual Amp in HMI. Real time data logger for fault checking. Fault indicator like Under load, Over load, reverse phase, Single phase preventer (ix) Secondary Tube Settler Type : Honey comb type MOC : PVC Length : 700 mm

-

-

-

... More
(x) Recirculation Arrangement : Recirculationcarried out through Blower air which is used for aeration for saving of power. (xi) Diffuser - 14 Nos Type :Tubular type MOC:Silicon Size: 63 mm dia X 600mm Make : CWC/Cheston (xii) MBBR Media - 7.35 m3 Type :Floating Media Surface Area : 190sqm/Cum Size: 63mm diaX10mm MOC : PP Make Yogeshwar Pastic (xiii) Filter Feed Pump - 02 Nos (1W+1S) Type : SS Centrifugal Pump Make : Lubi/ Kirloskar/ KDS Pump / Equav Head : 30 m Flow : 5 m3/hr (xiv) Pressure Sand Filter - 01 No MOC : FRP Design Pressure: 10Kg/cm2 Operation Presure : 4Kg/cm2. Capacity : 5m3/hr Make : Pentair

-

-

-

... More
(xv) Activated Carbon Filter - 01 No MOC : FRP Design Pressure : 10 Kg/cm2 Operation Pressure : 4 Kg/cm2 Capacity : 3.5 m3/hr Make : Pentair (xvi) Pressure Gauge - As per design Range : 0 - 7 / Kg Make : Brinda/ Vision/ La/ Equav Type : Bottom mounted (xvii) Level Sensor - 04 Nos Type : Float type level sensors (xviii) Pressure Transmitter - 03 Nos Range : 0-10kg Make : Boumer/ARTACK/Danfoss Type : Bottom mounted (xix) Dosing Pump- 02 Nos (1W+1S) Type : Metering Type Flow : 0-4 LPH Make : Verito/UKL/Acemic/Infinity (xx) Dosing Tank- 01 No Capacity : 70 KLD Make : Verito/UKL/Acemic/Infinity"

-

-

-

... More
(xxi) Centrigfuge - 01 No Capacity : 12 Kg per Batch MOC: PP Make : Maruti/ Infinity (xxii) SCADA for Operation - 01 No (xxi) Collection Tank- 01 No MOC : RCC Underground Tank Capacity : 30 KLD (Water Volume) (xxii) Removal Mechanism- 01 No MOC : MSEP Underground Tank Capacity : 250 Ltr (xxiii) AerationTank- 01 No Capacity : 24.50 KL MOC : MSEP (xxiv) Secondary Clarifier Capacity : 14.7 KL MOC : MSEM" (xxv) Intermediate Tank- 01 No Capacity : 10 KL MOC : LLDPE (Readymade Tank)

-

-

-

... More
(xxvi) Treated Water Tank- 01 No Capacity : 30 KL (Water volume) MOC : RCC (xxvii) Blower / Penal Room/ 16 m2 - 01 No (xxviii) Treated Water Pump - 02 Nos (1W+1S) Type : Centrifugal Pump Make : Lubi/Kirloskar Head : 30 m Flow : 5cum/Hr (xxix) Intermediate Sewage Collection Sump in M30 Mix of 50 KL cap top RCC roof slab with CI manhole cover with MS ladder ventilation shaft with top room all as specified and directed - 01 No (xxx) Non clog vertical submersible pump of cap 150 LPM at 25m head (3 HP) with chrome steel impeller and utter non clog to pass 40mm size particles including supply , installation with guide rail and lifting chain, cable, earthing including all electrical connection all as specified and directed - 03 Nos (2W+1S)

-

-

-

... More
M&L for construction of valve pit of size 0.6 x 0.6 x 0.6 m (internal diamention) one brick thick wall including MS sheet cover made of MS sheet 3 mm thick and 50 x 50 x 6 mm thick MS angle iron frame and locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed.

4

-

-

... More
Design, supply, construction, erection, testing and commissioning of water treatment of capacity 10000 GPH to bring down raw water parameters with in drinkable permissible limit comprising of oxidation chamber, ACF, MGF & pressure filter cum Iron removal plant, air compressor with back wash facility, alum mixture, dosing pump, tank and agitator, soda ash dosing pump, tank and agitator, pre and post chlorination dosing pump and tank & agitator complete including connecting all piping work with heavy duty MS pipe of suitable size for filters and CPVC pipe for alum, soda ash and pre and post chlorine plant with all fittings, sluice valves, check valves and non return valves (all butterfly type) , gate valves as required on site and as per OEM recommendation complete all as specified and directed. Note : (a) Design, supply, install, commissioning & testing of Oxidation chamber, closed type with catalytic media, under bed plate fitted with strainers, along with suitable capacity of electric driven air compressor with necessary connections with required size of compressed air line and control valves for compressed air – 01No." (b) Design, supply, install, commissioning & testing of Chemical Dosing system for sodium hypochlorite for Pre chlorination with Dozing Pump set (01 + 01 Stand by), FRP dozing tank with agitator – 01No (c) Design, supply, install, commissioning & testing of Chemical Dosing system for Soda Ash with Dozing Pump set (01 + 01 Stand by), FRP dozing tank with agitator – 01 No. (d) Design, supply, install, commissioning & testing of Chemical Dosing system for Alum with Dozing Pump set (01 + 01 Stand by), FRP dozing tank with agitator – 01 No. Item Contined as Ser No. 19.95 to 19.97

1

-

-

... More
(e) Design, supply, install, commissioning & testing of Multi graded filter media. Filter shall be painted internally with food grade, non toxic epoxy paint and externally with two coats of epoxy paint over a coat of primer – 01 No. (f) Design supply, install, commissioning & testing of Iron Removal Filter with filter media. Filter shall be painted internally with food grade, non toxic epoxy paint and externally with two coats of epoxy paint over a coat of printer – 01 No. (g) Design, supply, install, commissioning & testing of Activated Carbon Filter with filter media. Filter shall be painted internally with food grade, non toxic epoxy paint and externally with two coats of epoxy paint over a coat of primer – 01 No. (h) Design, supply, install, commissioning & testing of Chemical Dosing system for sodium hypochlorite for Post chlorination with Dozing Pump set (01 No), FRP dozing tank with agitator – 01 No. (j) All inlet and out let GI pipe line of suitable size form clear water pump set up to treated water pump through water treatment plant with control valve before and after each branch of MGF, ACF and IRF as required – (01 set). (k) All inlet and out let GI pipe line of suitable size for back washing system inlet pipe line upto 50 RM with control valve from existing line and out let pipe line upto 50 RM from the MGF, ACF, IRF filters with control valves. (01 set).

-

-

-

... More
(l) All inlet and out let CPVC pipe line of suitable size for Dozing system of Pre chlorination, Soda Ash, Alum and Post chlorination inlet pipe line up 60 RM with control valves from existing line and out let pipe as per requirement from the Dozers with control valves. (01 Set). (m) Pressure gauges to monitor the head losses at in let and out let of MGF, ACF, IRF and oxidation chamber – 01 set. (n) Flow meter at inlet of oxidation chamber and inlet of MGF – 01 set. (o) On line digital type PH meter to be installed inlet of sedimentation tank, on line digital type PH meter and turbidity meter to be provided at outlet line of ACF. Chemical kits for measuring hardness, residual chlorine and iron - 01 Set.

-

-

-

... More
Supply and fix Monoblock pump set suitable for 415 V, 3 phase system having capacity 5 HP complete all as specified and directed.

2

-

-

... More
Supply and fix Monoblock pump set suitable for 415 V, 3 phase system having capacity 12.5 HP complete all as specified and directed.

2

-

-

... More
Supply and lay pipe ductile Iron, S/S / flanged pipe including specials, Class “K-9”, 100 mm (4”) dia complete all as specified and directed.

50

-

-

... More
Supply and fix automatic air release valve 100mm dia suitable for domestic water with 100 mm gun metal stop valve complete all as specified and directed.

4

-

-

... More
Supply of Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete all as specified and directed.

2

-

-

... More
Supply of PH test kit with coloured ample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) with necessary fitments and 100 ml testing solution in Rexene finished box complete all as specified and directed.

1

-

-

... More
Supply of Iron test kit complete all as specified and directed.

1

-

-

... More
Supply of Hardness test kit complete all as specified and directed.

1

-

-

... More
SOLAR POWER GENERATION SYSTEM Design, procure, erect install, test and commission including connecting to local utility grid; Grid connected solar photovoltaic plant of 50 KWp cap capacity (roof top) including solar photovoltaic Module, DC cabling, Module Mounting Structures, Combining Boxes, Lightning Protection of SPV modules and other accessories, string inverter, consisting of following main components complete all as specified and directed: -(SM Barrack - 04 Nos , CH & DH & Kitchen - 02 Nos) Poly Crystalline Silicon Solar Photovoltaic minimum of 335 Wp, not less than 60 KWp & 15 KWp respectively for 60 KWp & 15 KWp solar power plant capacity, having efficiency 16.28% min under standard conditions, form fill factor more than 0.74, plant performance ratio 75% , made of high transitivity glass front surface and it shall give high encapsulation gain ( transmittance above 90% and bending less than 0.3%). The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm2, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under Max Peak Power Pmax 335 W Voltage at Max Power :37.9V Current at Pmax: 8.85 A Short Circuit Current : 9.41 A Open Circuit Voltage: 46.27 V Module Efficiency: 16.28 % . (a) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed. (b) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 150 kmph on the surface of panel. Item Contined as Ser No. 20.06 to 20.11

6

-

-

... More
(c) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. (d) Each module shall have RFID tag encapsulated with solar cell bearing following details: Name of manufacture of SPV Module, Name of Manufacturer of solar cell and module) country of Origin ( both cell and module) Peak wattage, Im, Vm and fill factor of the module IV curve of module. (e) The temperature coefficient of the module shall not be more than 0.50% degree Celsius. (f) PV modules must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID. (g) It shall also be in conformity to latest minimum technical specification issued by MNRE from time to time. Modules should be of 48 cell configuration and should be of MNRE approved companies/agencies in category/ rating 'SA-1A' . (h) Provision of earting and earth strip/ cable etc for earth of solar Pv module/ array etc as per latest IS/MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (j) Both cell and SPV modules shall be made in India and must conform to DSR norms of MNRE (k) The minimum net annual generation shall be 1500 units per kilowatt.

-

-

-

... More
(l)DC Cables & AC Cables: Suitable size of XLPE insulated tinned copper cable of solar grade, 1100 volt and UV resistant for outdoor installations confirming to IEC 60227/15694 & 60502/ is 1554 (Pt& I&II) of minimum size 6 sq.mm All cables and connectors for use of installation shall be of solar grade which can withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years as voltage as per latest IEC/IS. All the cables/wires shall be provided with UV resistant printed ferrules for DC side .The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. The AC cables along with AC DB with necessary arrangement to Connect with the existing power supply to be done. The size of XLPE LT cable To be got approved by Engineer in charge. Suitable electronic smart meter To be fixed to measure generation of electricity. Cable batch no, drum no, IS code and size and make shall be mentioned on every one meter or as per OEM practice .The wiring of the module interconnection shall be in suitable size UPVC/HDPE pipe. The cost of interconnecting DC copper cable and earth work for trenches suitable to accommodate solar grade cables from SPV module upto inverters are included in the item.

-

-

-

... More
(m)Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanisized iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts,mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fastners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with stadpro report and submitted for the approval of the acepting officer. Cost of all equipments, copper strip up to earth test point and copper earthing etc are included in this item. The cost of sufficient earthing for lightning protection is included in this item and no extra payment will be made to the contractor on this account.

-

-

-

... More
(n)String Inverter: Procure, fixing, testing and commissioning of 10 KW , 50+3 Hz (min) 3 phase 460 volt, THD 3%, at nominal power inverter suitable to convert DC power of solar PV module/arry/ to AC for further feeding to grid confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 10 KW inverter are as under: Input (DC) DC V oltage Range: 575-850 V Max DC Voltage:1000 V Nominal Power : 10 kW Max output power : 10 kW Nominal AC current : as per standards Nominal output voltage: 460V Output Frequency : 50/60 Hz Harmonic Distortion current : 3% Efficiency : 98.3% Standby operation consumption (feed in) : 20 W

-

-

-

... More
Operating temperature up to 85 degree centigrade. The inverter shall have minimum IP 65 protection, ground fault monitoring, grid monitoring, protection against anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and temperature . The inverter shall adjust voltage and frequency levels to suit the grid . The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. Maximum Power Point Tracker(MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximum the energy drawn from the PV array. The inverter shall be suitable nos of protected inputs (as per design) and outgoing shall be protected by Surge protections (MOVs) .The inverter shall be provided with protection class I (IEC 62103) .The inverter should have MODBUS, PROFIBUS, ETHERNET comn ports .The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of the inverter component failure or from parameters beyond the inverters safe operating due to internal and/or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, ( SPD) & over current. Inverter should interfaces with Ethernet, RS485, irradiation and temperature sensor, Auxiliary equipment and power supply, external stop signal. Should have residual monitoring system.

-

-

-

... More
Design, procure, erect install, test and commission including connecting to local utility grid; Grid connected solar photovoltaic plant of 15 KWp cap capacity (roof top) including solar photovoltaic Module, DC cabling, Module Mounting Structures, Combining Boxes, Lightning Protection of SPV modules and other accessories, string inverter, consisting of following main components complete all as specified and directed: - Poly Crystalline Silicon Solar Photovoltaic minimum of 335 Wp, not less than 60 KWp & 15 KWp respectively for 60 KWp & 15 KWp solar power plant capacity, having efficiency 16.28% min under standard conditions, form fill factor more than 0.74, plant performance ratio 75% , made of high transitivity glass front surface and it shall give high encapsulation gain ( transmittance above 90% and bending less than 0.3%). The electrical parameters of SPV modules under standard test condition of irradiance 1000 W/sqm2, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under Max Peak Power Pmax 335 W Voltage at Max Power :37.9V Current at Pmax: 8.85 A Short Circuit Current : 9.41 A Open Circuit Voltage: 46.27 V Module Efficiency: 16.28 % . (a) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed. (b) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 150 kmph on the surface of panel. Item Contined as Ser No. 20.12 to 20.17

6

-

-

... More
(c) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. (d) Each module shall have RFID tag encapsulated with solar cell bearing following details: Name of manufacture of SPV Module, Name of Manufacturer of solar cell and module) country of Origin ( both cell and module) Peak wattage, Im, Vm and fill factor of the module IV curve of module. (e) The temperature coefficient of the module shall not be more than 0.50% degree Celsius. (f) PV modules must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID. (g) It shall also be in conformity to latest minimum technical specification issued by MNRE from time to time. Modules should be of 48 cell configuration and should be of MNRE approved companies/agencies in category/ rating 'SA-1A' . (h) Provision of earting and earth strip/ cable etc for earth of solar Pv module/ array etc as per latest IS/MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (j) Both cell and SPV modules shall be made in India and must conform to DSR norms of MNRE (k) The minimum net annual generation shall be 1500 units per kilowatt.

-

-

-

... More
(l)DC Cables & AC Cables: Suitable size of XLPE insulated tinned copper cable of solar grade, 1100 volt and UV resistant for outdoor installations confirming to IEC 60227/15694 & 60502/ is 1554 (Pt& I&II) of minimum size 6 sq.mm All cables and connectors for use of installation shall be of solar grade which can withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years as voltage as per latest IEC/IS. All the cables/wires shall be provided with UV resistant printed ferrules for DC side .The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. The AC cables along with AC DB with necessary arrangement to Connect with the existing power supply to be done. The size of XLPE LT cable To be got approved by Engineer in charge. Suitable electronic smart meter To be fixed to measure generation of electricity. Cable batch no, drum no, IS code and size and make shall be mentioned on every one meter or as per OEM practice .The wiring of the module interconnection shall be in suitable size UPVC/HDPE pipe. The cost of interconnecting DC copper cable and earth work for trenches suitable to accommodate solar grade cables from SPV module upto inverters are included in the item.

-

-

-

... More
(m)Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanisized iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts,mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fastners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with stadpro report and submitted for the approval of the accepting officer. Cost of all equipments, copper strip up to earth test point and copper earthing etc are included in this item. The cost of sufficient earthing for lightning protection is included in this item and no extra payment will be made to the contractor on this account.

-

-

-

... More
(n)String Inverter: Procure, fixing, testing and commissioning of 10 KW , 50+3 Hz (min) 3 phase 460 volt, THD 3%, at nominal power inverter suitable to convert DC power of solar PV module/arry/ to AC for further feeding to grid confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 10 KW inverter are as under: Input (DC) DC V oltage Range: 575-850 V Max DC Voltage:1000 V Nominal Power : 10 kW Max output power : 10 kW Nominal AC current : as per standards Nominal output voltage: 460V Output Frequency : 50/60 Hz Harmonic Distortion current : 3% Efficiency : 98.3% Standby operation consumption (feed in) : 20 W

-

-

-

... More
Operating temperature up to 85 degree centigrade. The inverter shall have minimum IP 65 protection, ground fault monitoring, grid monitoring, protection against anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and temperature . The inverter shall adjust voltage and frequency levels to suit the grid . The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. Maximum Power Point Tracker(MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximum the energy drawn from the PV array. The inverter shall be suitable nos of protected inputs (as per design) and outgoing shall be protected by Surge protections (MOVs) .The inverter shall be provided with protection class I (IEC 62103) .The inverter should have MODBUS, PROFIBUS, ETHERNET comn ports .The inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of the inverter component failure or from parameters beyond the inverters safe operating due to internal and/or external causes. Inverter shall have protection arrangement against ground leakage faults, over voltage, ( SPD) & over current. Inverter should interfaces with Ethernet, RS485, irradiation and temperature sensor, Auxiliary equipment and power supply, external stop signal. Should have residual monitoring system.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.