Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date31 Aug 2024
Closing DateCancelled
Tender Amount₹ 44,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F for 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with L type or J type or cranked hook bolts in lieu of acrews complete all as specified and as directed

10

-

-

... More
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.

50

-

-

... More
S&F for aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of distemper oil emulsion complete all as specified and as directed. Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd.

50

-

-

... More
Taking down chowkats or frame exceeding 1.5 Sqm and not exceeding 4.00 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.

25

-

-

... More
Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.

55

-

-

... More
Refixing shutters of any description exceeding 1.0 sqm but not exceeding 2.0 sqm each in the same opening complete as directed.

15

-

-

... More
Refixing shutters of any description not exceeding 1.0 sqm each in the same opening complete all as specified and as directed.

15

-

-

... More
S&F pressed steel frames for doors of size 105x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.

40

-

-

... More
S&F pressed steel frames for doors of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.

70

-

-

... More
S&F for well seasoned second class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints including treating the timber libarally brushed at least twice with oil or kerosene based solusion of chlorophyrifos 20EC 1.0 % (by weight) concentration complete all as specified and as directed.

1.2

-

-

... More
S&F for mild steel small articles using flat iron of size 25x3mm thick such as band, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290 (Gde E-165) complete all as specified and as directed.

45

-

-

... More
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde (E-165) complete all as specified and as directed.

250

-

-

... More
S&F 35 mm thick factory made second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.

45

-

-

... More
S&F 35 mm thick, second class hard wood, glazed and skeleton shutters with open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitered beads for securing glass, etc, sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a), complete all as specified and as directed.

25

-

-

... More
S&F for 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded for windows, ventilators etc. are provided with stiles and rails as specified in SSR Part I Section 8 clause 8.24 (b) complete all as specified and as directed.

15

-

-

... More
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.

65

-

-

... More
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed by Engr-in-Charge.

15

-

-

... More
S&F for 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.

145

-

-

... More
S&F for 75mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.

40

-

-

... More
S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.

60

-

-

... More
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.

130

-

-

... More
S&F 150 mm long, aluminium handles, cast type, anodised complete all as specified and as directed.

80

-

-

... More
S&F 100 mm long, aluminium handles, cast type, anodised complete all as specified and as directed.

90

-

-

... More
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.

20

-

-

... More
S&F in repair steel windows with side double hung shutters including projecting /box type hinges with steel handle, and steel peg stay complete with glazing bars, devotailed or welded complete all as specified and as directed.

15

-

-

... More
S&F in repair steel windows with side double hung shutters including projecting /box type hinges with steel handles and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and as directed.

25

-

-

... More
S&F in repair steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and as directed.

15

-

-

... More
M&L for anodised aluminium frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc including powder coating of minimum 50 micron thickness complete all as specified

50

-

-

... More
S&F for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as specified and as directed.

80

-

-

... More
S&F for 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.

15

-

-

... More
S&F in repair 12mm thick prelaminated particle board, interior grade, both side with decorative choice lamination fixed with screws to timber frame works as in shutter of cup board and other similar work complete all as specified and as directed.

15

-

-

... More
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer including necessary scaffolding complete all as specified and as directed.

230

-

-

... More
S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with wooden bit or stainless steel wire staples as required complete all as specified and as directed.

15

-

-

... More
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with MS fillets and stainless steel wire staples complete all as specified and as directed

15

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel frames, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.

25

-

-

... More
S&F 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.

25

-

-

... More
S&F in repair mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.

10

-

-

... More
S&F in repairs curtain rails, Harrison rail, anodised, aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed.

85

-

-

... More
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as directed.

22

-

-

... More
M&L for non-skid, coloured ceramic tiles, 7 to 8 mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over and including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.

60

-

-

... More
M&L for coloured glazed ceramic tiles in vertical surface as in skirting, dado and risers to steps etc, of size 450X 300X 7 mm thick over and including 10mm thick rendering as backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, complete all as specified and directed.

125

-

-

... More
M&L for prepolished chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc, including 20 mm thick screed bed or bedding in cement mortar (1:4) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.

25

-

-

... More
M&L for granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.

10

-

-

... More
Taking up or down 15mm bore existing steel tubing and connections including cleaning for refixing or removal from site complete all as specified and as directed.

65

-

-

... More
Taking up or down 20mm bore existing steel tubing and connections including cleaning for refixing or removal from site complete all as specified and as directed.

40

-

-

... More
Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed.

50

-

-

... More
Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed.

25

-

-

... More
Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete obtained from item above respectively as directed.

15

-

-

... More
Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete obtained from item above respectively as directed.

15

-

-

... More
S&F in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor using concrete (1:2:4) type B0 and to match with existing specifications complete all as specified and as directed.

5

-

-

... More
S&F in repairs vitreous china Semi pedestal pattern (Anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces to match with existing complete all as specified and as directed.

5

-

-

... More
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe including PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete (1:4:8) type D2 and to match with existing specifications complete all as specified and as directed.

5

-

-

... More
S&F in repairs vitreous china wash basin, size 550 x 400mm, white, flat back, including 32mm bore PVC (HDPE) waste pipe 450mm long, 32mm bore CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.

5

-

-

... More
S&F in repairs, PVC low level flushing cistern, 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe and flush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed

15

-

-

... More
M&L for 100mm dia PVC grating doom PTMT (minimum weight 25 gms) complete all as specified and as directed.

20

-

-

... More
S&F in repairs, 15mm dia, bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.

20

-

-

... More
S&F in repair 15 mm bore, stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.

15

-

-

... More
S&F in repair 15 mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.

10

-

-

... More
S&F in repair 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.

25

-

-

... More
S&F in repair 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on PVC frame including key hole plates for hanging and fixed to wall with chromium plated cup washers and screws complete all as specified and as directed.

10

-

-

... More
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.

30

-

-

... More
S&F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms) complete all as specified and as directed. .

55

-

-

... More
Disconnecting water storage/service tank (RCC/PVC tank) exc 250 Litre but not exc 500 Litre capacity, cleaning and removing all scales Dirt, etc from Tank and mouths of circulating and wash out pipes of Tank with bleaching power. Re-hoisting in same position and re-connecting, including Re-writing with synthetic enamel paint DATE OF CLEANING and DUE ON complete all as specified and as directed.

30

-

-

... More
Dismantling water storage tank exc 250 & n.exc 500 ltr capacity and removing from site, complete all as specified and as directed.

5

-

-

... More
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight - 210 gms) complete all as specified and as directed.

5

-

-

... More
S&F in repairs 20mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and as directed.

5

-

-

... More
S&F in repairs 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.

30

-

-

... More
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick screed bed in cement mortar 1:4 finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm Note :- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.

200

-

-

... More
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.

25

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and directed.

8

-

-

... More
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.

133

-

-

... More
S&F in repairs 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.

18

-

-

... More
Dismantling of 100mm bore, cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed.

85

-

-

... More
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.

35

-

-

... More
S&F for 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.

60

-

-

... More
S&F for 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.

40

-

-

... More
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.

15

-

-

... More
S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.

8

-

-

... More
S&F for 110 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and as directed.

20

-

-

... More
S&F for 75 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and as directed.

8

-

-

... More
S&F for 110 mm bore, PVC (SWR) vent cowl fixed with solvent cement complete all as specified and as directed.

8

-

-

... More
S&F in repairs flexible (coil shaped) PVC waste pipe for sink and wash hand basin 32/40mm dia, length not less than 70 cm, connected to PVC waste coupling/fittings complete all as specified and as directed.

80

-

-

... More
S&F in repairs PTMT(half or full threaded) waste coupling 32mm for sink (min weight 32mm - 45gms / 40mm- 60gms) complete all as specified and as directed.

30

-

-

... More
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and as directed.

1500

-

-

... More
M&L for preparation of old old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.

750

-

-

... More
M&L for preparing old plastered or unplastered surfaces of walls by washing, rubbing down and scraping of existing distempering/ painted surfaces etc and applying one coat of distemper oil emulsion complete all as specified and as directed.

2500

-

-

... More
M&L for preparing old decorated surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of primer including 2mm thick wall care putty complete all as specified and as directed.

500

-

-

... More
M&L for preparation old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and gresase spots and applying two coat of cement base paint (white or tinted) including necessary scaffolding complete all as specified and as directed

2250

-

-

... More
M&L for preparation of newly plastered surfaces or previously undecorated surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.

400

-

-

... More
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as per manufacturer's instruction complete all as specified and as directed.

250

-

-

... More
M&L for preparation of old wooden surfaces of any description, exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete as specified and as directed.

350

-

-

... More
M&L for preparation of old wooden surfaces of any description, not exceeding 10 cm width or girth and applying one coat of synthetic enamel paint when unconnected with other painting or when painted in different tint complete as specified and as directed.

45

-

-

... More
M&L for preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.

30

-

-

... More
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100 mm thickness of concrete slab complete all as specified and as directed.

3

-

-

... More
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.

16.75

-

-

... More
M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.

6

-

-

... More
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.

100

-

-

... More
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed

400

-

-

... More
M&L for rendering 15 mm thick on fair faces of external surface of wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar (1:4) using water proofing compound in top layer (water proofing compound measured as separately) and finished even and smooth without using extra cement complete all as specified and directed.

400

-

-

... More
Supply only Liquid water proofing compound complete all as specified and as directed.

4

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, pipeline etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.

150

-

-

... More
Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in hard/dense soil complete all as specified and as directed.

97

-

-

... More
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.

53

-

-

... More
Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 100/110 mm bore pipe complete all as specified and as directed by Engineer-in-Charge .

3

-

-

... More
Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 150/160mm bore pipe, complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 200/225mm bore pipe complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 150/160mm dia complete all as specified and as directed by the Engineer-in-Charge

40

-

-

... More
M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.

40

-

-

... More
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed .

40

-

-

... More
Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 200/225mm dia complete all as specified and as directed by the Engineer-in-Charge

30

-

-

... More
M&L for salt glazed stone ware drain pipes 200 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.

30

-

-

... More
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore SGSW/RCC drain pipes complete all as specified and as directed .

30

-

-

... More
Attending of complaint by covering the following items of work :- (a) Cleaning and clearing of blocked IWCs and EWCs to sewage line upto 1st manholes by rodding or any other suitable method and taking out the muck, mud and other debris from WCs and the sewage line cleaning with fresh water & removing the debris upto a distance exceeding 200M and not exceeding 250M and covering the same with a layer of soil not less than 15cm thick complete all as specified and as directed by Engr-in-Charge. (b) Cleaning and clearing of blocked chocked floor trap in kitchen and bathrooms including gully trap, the waste water line connection etc by rodding or by any other suitable method and taking out the debris to a distance exceeding 200m & not exceeding 250m and covering the same with a layer of soil not less than 15cm thick and drain out the floors taps, gully traps waste pipe and soil pipe with fresh water etc complete all as specified and as directed. Note:-(i) Adequate number of workmen shall be deployed as and when complain received for immediate execution. If any complaint not attend by the contractor within a day then a sum of Rs. 50.00 will be recovered against per complain per day from the contractor. (ii) Rate quoted above shall be deemed to including the cost of adequate T&P, equipment, safety devices etc (iii) Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.

450

-

-

... More
Taking out liquid/solid content from manhole/ sump/ septic tank of any size any depth by super succer machine or high pressure pump, cleaning throughly including disposal of liquid/solid content out of the Cantt Area and covering with a layer of soil not less than 15cm thick complete all as specified and as directed.

230

-

-

... More
Cleaned blocked drain pipes (SGSW/hume pipe) up to 150mm bore by rodding from manholes and well flusing with water after cleaning the same all as directed and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around slope all complete as required and directed.

200

-

-

... More
All as per item No 118 here-in-before but exc 150mm and n.exc 250mm bore pipes.

100

-

-

... More
All as per item No 118 here-in-before but exc 250mm and n.exc 450mm bore pipes.

30

-

-

... More
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.

231

-

-

... More
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.

150

-

-

... More
All as per item No 122 above but for one 3 pin socket outlet, 5 Amps on Independent board.

25

-

-

... More
All as per item No 122 above but for one 5 Amps, 3 pin socket outlet on the same board with other switches.

30

-

-

... More
All as per item No 122 above but for one light point controlled by two way switch.

5

-

-

... More
All as per item No 122 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board complete all as specfied and as directed.

13

-

-

... More
S&F for switch piano, flush type single pole, 230 volts, 5 Amp one way bearing ISI marked complete all as specified and as directed.

180

-

-

... More
S&F for switch piano, flush type single pole, 230 volts, 5 Amp two way bearing ISI marked complete all as specified and as directed.

10

-

-

... More
S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, 240V bearing ISI marked complete all as specified and as directed.

30

-

-

... More
S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.

25

-

-

... More
S&F for switch socket combination, 5 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.

13

-

-

... More
S&F for bell push, flush type, 5 Amps 230 Volts, bearing ISI marked complete all as specified and as directed.

8

-

-

... More
S&F for call bell, AC, 230 volts, single pole complete all as specified and as directed.

8

-

-

... More
S&F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.

120

-

-

... More
S&F for stepped type (five steps), electronic fan regulator, flush type (socket type) complete all as specified and as directed.

30

-

-

... More
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.

30

-

-

... More
S&F for LED Lamp 9 Watt complete all as specified and as directed.

30

-

-

... More
S&F for 18 Watt surface and wall mounting type LED batten with white acrylic cover sleek design & high efficiency complete all as specified and as directed.

60

-

-

... More
S&F LED building security light fitting 35 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including all necessary items for installation complete all as specified and as directed.

15

-

-

... More
S&F for 10 Watt, LED energy saving new generation bulk head luminaire with opal diffuser including lamp, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.

15

-

-

... More
Taking down unserviceable sub-main wiring up to 10 sqmm with rigid steel conduits/PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.

50

-

-

... More
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.

50

-

-

... More
S&F in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral, 8 way, 240 Volts suitable for housing MCBs complete all as specified and as directed.

10

-

-

... More
S&F MCB, 'C' Series, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.

10

-

-

... More
S&F MCB, Single pole and neutral , 240 Volts, 6 to 32 Amps, 'C' series, 10KA capacity breaking capacity complete all as specified and directed,

60

-

-

... More
S&F in repairs switch piano, flush type, 5 Amps, single pole, one way, bearing ISI marked 240 Volts complete all as specified and as directed.

50

-

-

... More
S&F in repair socket outlet, 2 in 1, 3 pin , 5 Amps, flush type bearing ISI marked complete all as specified and as directed.

30

-

-

... More
S&F in repair switch socket combination 2 in 1, 5 pin, 5 Amps, flush type, bearing ISI marked 240 volts complete all as specified and as directed.

10

-

-

... More
S&F in repair switch socket combination 2 in 1, 6 pin, 5/16 Amps, flush type, bearing ISI marked 240 volts complete all as specified and as directed.

10

-

-

... More
S&F in repairs bell push, flush type, 5 Amps 230 Volts bearing ISI marked complete all as specified and as directed.

5

-

-

... More
S&F in repairs ceiling rose, 3 phase, PVC polycarbonate, isolated body (with PVC box) bearing ISI marked complete all as specified and as directed.

10

-

-

... More
S&F in repair Stepped type(five steps), electronic fan regulator, 220 volts, flush type complete all as specified and as directed.

10

-

-

... More
S&F in repair 18 Watt surface and wall mounting type LED batten with white acrylic cover sleek design & high efficiency complete all as specified and as directed.

60

-

-

... More
S&F in repair lamp holder, PVC/Polycarbonate type insulated body with back plate in existing location suitable for batten fittings complete all as specified and as directed.

20

-

-

... More
S&F in repair LED Lamp 9 Watt complete all as specified and as directed.

50

-

-

... More
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed.

7

-

-

... More
M&L for earthing with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing including taking down old unserviceable complete all as specified and as directed.

1

-

-

... More
Trimming of tree branches around the overhead conductor, polesand stay (not less than 3 meter ) to clear the approch of overhead lines incl removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including clearing of creepers climbed on poles and angles, channels and disposed off from site beyond 50m and upto a total 250m complete all as specified and as directed. Note : Span 30 to 50 meter shall be measured as one unit.

5

-

-

... More
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.

31.83

-

-

... More
Laying only old common burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables including taking down old unserviceable complete all as specified and directed.

700

-

-

... More
Supply and laying common burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables including taking down old unserviceable complete all as specified and directed.

2800

-

-

... More
Supply, fabricate and fixing of clamp made of GI strip of size not less than 32 x 6mm (Fe-290, Gde E-165) for support of cable protection pipe of existing size from existing steel/ RCC pole of any size by making hole to strip and fixed with suitable size of nut & bolt and washer complete all as specified and as directed.

50

-

-

... More
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT, 20 x 15 cm size including taking down of old one complete all as specified and as directed.

5

-

-

... More
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.

393

-

-

... More
Laying only old serviceable XLPE insulated, armoured, nominal cross sectional area of main conductor , stranded aluminium conductor, 1100 volt grade, any size, 2/3.5/4 core, to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.

50

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 6 Sqmm, 2 core, nominal cross sectional area of main conductor stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.

50

-

-

... More
All as per item No 166 here-in-above but nominal cross sectional area of conductor 10 Sqmm, 2 core

100

-

-

... More
All as per item No 166 here-in-above but nominal cross sectional area of conductor 16 Sqmm, 2 core

73

-

-

... More
All as per item No 166 here-in-above but nominal cross sectional area of conductor 25 Sqmm, 3 core

50

-

-

... More
All as per item No 166 here-in-above but nominal cross sectional area of conductor 35 Sqmm, 3 core

70

-

-

... More
M&L for stay assembly comprising of 7/8 SWG galvanised stay of standard wire of required length fixed to pole with and including galvanised flat iron clamps, bolts, nuts and washers etc including galvanised steel 14 mm dia, 400 mm long stay bow and GI stay plate of size 300 x 300 x 6 mm thick, thimble MS clamp made out of 50 x 6mm and loop insulators porcelain brown all as shown in EP No.1 of SSR part - I including all accessories and excavation, earth work and PCC work complete all as specified and as directed.

1

-

-

... More
Dismantling cross-arms of M.S. channel or angle sections etc. complete and stacking aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as specified and as directed.

0.3

-

-

... More
M&L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts, bolts & washers, welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one coat of aluminium paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed.

0.3

-

-

... More
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed.

11

-

-

... More
Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade complete all as specified and as directed.

5

-

-

... More
Supply and fixing shackle type, porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and bolt of 14mm dia, suitable for 1100 volts complete all as specified and as directed.

3

-

-

... More
Supply and fixing loop type porcelain vitreous white, brown or green insulator small size, with overall dimensions 65 x 90 mm, clearance of hole 16mm including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, complete all as specified and directed

3

-

-

... More
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in pole foundation, filling and mass concrete complete all as specified and as directed.

1

-

-

... More
M&L for plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in coping of pole including necessary form work for fair finish surfaces complete all as specified and as directed

0.5

-

-

... More
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed

1

-

-

... More
Supply, fixing and stringing of aluminium conductor steel reinforced (ACSR) conductor of size (a) Squireel 6/1 x 2.11, (b) Weasel 6/1 x 2.59, (c) Rabbit 6/1 x 3.25 as suitable conforming to IS - 398 part- 4 of 1994 including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape complete all as specified and as directed.

1

-

-

... More
Restringing of old aluminium conductor steel reinforced (ACSR) or AAAC conductor of 4 wire line ( 3 phase and neutral) and make on LT 9 m long poles alongwith earth wire, including replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including prunning of tree branches 2 mtr all around OH LT line by means of pulley, rope etc complete all as specified and as directed. Note : 04 Nos of ACSR or AAAC conductor shall be measured as one unit length.

50

-

-

... More
Restringing of old aluminium conductor steel reinforced (ACSR) or AAAC conductor of 2 wire line (single phase and neutral) and make on LT 9 m long poles alongwith earth wire, including replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including prunning of tree branches 2 mtr all around OH LT line by means of pulley, rope etc complete all as specified and as directed. Note : 02 Nos of ACSR or AAAC conductor shall be measured as one unit length.

50

-

-

... More
Dismantling existing unserviceable GI earth wire, cradles of any type obtained from service feeder or distributor span complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.

0.2

-

-

... More
M&L for Galvanised steel wire 3.15 or 4mm dia (hexagonal/ rectangular ) used for cradles guarding, earthing suitable for LT/HT overhead line etc complete all as specified and as directed.

0.2

-

-

... More
S&F for PVC/fiber separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 2 conductor, in span without damaging the over head line including taking down old separator complete all as specified and as directed .

8

-

-

... More
S&F for PVC/fiber separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 4 conductor, in span without damaging the over head line including taking down old separator complete all as specified and as directed .

5

-

-

... More
Boring of holes horizontal for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.

6

-

-

... More
M&L for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors complete all as specified and as directed.

6

-

-

... More
Dismantling /uprooting of LT/HT unserviceable pre-stressed concrete /steel poles of any size and shape and including taking out dismantled portion of poles embedded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed. Note:- Earth work for taking out poles shall be measured and paid separately under relevant item of this Schedule.

1

-

-

... More
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as specified and as directed. Note : excavation and earth work, PCC filling shall be measured and paid separately.

1

-

-

... More
Dismantling of lightning arresters any type/size for any capacity complete all as specified & directed.

1

-

-

... More
M&L for LT lighting arresters for outdoor, use, non-linear resistor type, horn gap and choking coil, maximum working pressure 1100 volts complete all as specified and as directed.

1

-

-

... More
S&F for service connection cable, 1100 volts grade, heavy duty, cable PVC insulated, aluminium conductor, stranded of size 6 Sqmm x 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed.

140

-

-

... More
S&F for service connection cable, 1100 volts grade, heavy duty, cable PVC insulated, aluminium conductor, stranded of size 10 Sqmm x 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed.

100

-

-

... More
S&F in replacement of cast iron cable route indicator with embrossing mark as LT cable, circular type 75mm dia duly fixed with suitable size of MS flat iron member to be embedded in PCC (1:3:6) type C1 block size 150 x150x 150mm complete all as specified and as directed.

5

-

-

... More
Supply and fixing in repair LED street light fitting 35/40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

3

-

-

... More
Supply and fixing in repair street light bracket made out of GI pipe (light grade) 40 mm dia 1.5 mtr long bent to required shape as directed and fixed to pole complete with and including two Nos. of M.S. flat 25mm x 4 mm clamps with necessary bolts, nuts and washers of suitable size complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Taking down existing old/ undserviceable MCCBs of any description from LT panel board complete all as specified and as directed.

7

-

-

... More
S&F for MCCB, 415 V, AC, 36 KA breaking capacity, 4 pole of rating 160 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.

1

-

-

... More
S&F for MCCB, 415 V, AC, 16 KA breaking capacity, 4 pole of rating 125 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.

2

-

-

... More
S&F for MCCB, 415 V, AC, 16 KA breaking capacity, 4 pole of rating 100 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.

2

-

-

... More
S&F for MCCB, 415 V, AC, 16 KA breaking capacity, 4 pole of rating 63 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.

2

-

-

... More
S&F resin type straight throught LT 1100 Volt cable joint kit of size 150-185 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.

2

-

-

... More
M&L for preparation of old painted surface and removing dust and other deposited material by scraping from LT PSC/steel tubular poles of upto 11.00 metre long, cross arms brackets and applying two coats of aluminium paint to all steel surfaces, including MS clamps, cable protection pipe, bracket fitted with street light fittings etc and one coat of cement based paint to PSC pole including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed. Note :(a) Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer. (b) Pole number should be wrriten on each pole with preparation date.

10

-

-

... More
Supply installation, commissioning and testing including providing all necessary electrical connection, LT Panel, outdoor type CPRI approved factory made out of 3.15 mm thick MS sheet of size 1.00mx 1.00 mx 0.50 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 Nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate, street light panel of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc including taking down Old unserviceable box complete all as directed by the Engr-in-Charge and comprising of the following accessories :- Incoming: (a) MCCB, 4 Pole, 125 Amps, 415 Volt, 36 KA I/C, with thermal and magnetic release. (b) Phase indicator lamp- Set of 3 (c) Aluminium bus bar 4 strip of 200 Amps (d) Internal connection strip from MCB/MCCB to Bus bar and Busbar to MCB/MCCB etc. Outgoing: (a) MCCB, 4 pole, 100 Amps, 415 Volt, 36KA- 01 No. (b) MCB, TPN, 32 A, 240 Volt, 18 KA - 05 Nos

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.